Zhen Bu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhen Bu has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Shinsuke Kato
7 shared publications- Shinsuke Kato
Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan
6 shared publications Takeo Takahashi
5 shared publicationsHong Huang
Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguroku, Tokyo 153-8505, Japan
4 shared publicationsYoshihiro Ishida
Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguroku, Tokyo 153-8505, Japan
4 shared publications- Keisuke Nakao
The University of Tokyo
2 shared publications
Latest Publications
- Top Cited Papers
- 1 June 2020
- Published by Elsevier in Sustainable Cities and Society
- Vol. 57
Prediction of energy consumption in hotel buildings via support vector machines
- 1 June 2020
- Published by Elsevier in Sustainable Cities and Society
- Vol. 57
Top Cited PapersPrediction of energy consumption in hotel buildings via support vector machines
- Open Access
- 1 January 2017
- Published by Elsevier in Procedia Engineering
- Vol. 205, 3130-3137
Discussion on heating strategies in winter of residential buildings in Shanghai aiming at ultra-low energy target
- 1 January 2017
- Published by Elsevier in Procedia Engineering
- Vol. 205, 3130-3137
Open AccessDiscussion on heating strategies in winter of residential buildings in Shanghai aiming at ultra-low energy target
- 1 December 2011
- Published by Elsevier in Building and Environment
- Vol. 46 (12) , 2490-2499
Wind tunnel investigation on influence of fluctuating wind direction on cross natural ventilation
- 1 December 2011
- Published by Elsevier in Building and Environment
- Vol. 46 (12) , 2490-2499
Wind tunnel investigation on influence of fluctuating wind direction on cross natural ventilation
- 22 November 2011
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 383-390, 5344-5349
Wind-Driven Natural Ventilation in an Areaway-Attached Basement with a Single-Sided Opening for Residential Purposes
This paper discusses the sustainability of the areaway-attached basement concept with the attentions focused on wind-driven single-sided natural ventilation. First, numerical simulations were performed on an areaway-attached basement with a single-sided opening. Two CFD approaches: Reynolds averaged Navier-Stokes (RANS) and large-eddy simulation (LES) were used and compared with the previous experimental results of effective ventilation rate. A good agreement between the measurement and LES model was found and RANS model tends to underestimate the ventilation rates. Furthermore, Based on LES with the inflow turbulent fluctuations, the mean airflow patterns within and around the areaway-attached basement was investigated for different wind incidence angles to examine the influences of wind direction on ventilation performances.
- 22 November 2011
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 383-390, 5344-5349
Wind-Driven Natural Ventilation in an Areaway-Attached Basement with a Single-Sided Opening for Residential Purposes
This paper discusses the sustainability of the areaway-attached basement concept with the attentions focused on wind-driven single-sided natural ventilation. First, numerical simulations were performed on an areaway-attached basement with a single-sided opening. Two CFD approaches: Reynolds averaged Navier-Stokes (RANS) and large-eddy simulation (LES) were used and compared with the previous experimental results of effective ventilation rate. A good agreement between the measurement and LES model was found and RANS model tends to underestimate the ventilation rates. Furthermore, Based on LES with the inflow turbulent fluctuations, the mean airflow patterns within and around the areaway-attached basement was investigated for different wind incidence angles to examine the influences of wind direction on ventilation performances.
- 21 November 2011
- Published by Springer Nature
- p. 151-193
New Criteria for Assessing the Local Wind Environment at the Pedestrian Level and the Applications
- 21 November 2011
- Published by Springer Nature
- p. 151-193
New Criteria for Assessing the Local Wind Environment at the Pedestrian Level and the Applications
- 3 October 2011
- Published by Taylor & Francis in HVAC&R Research
- Vol. 17 (5) , 847-859
Probability analysis of wind-driven natural ventilation potential in areaway-attached basements
- 3 October 2011
- Published by Taylor & Francis in HVAC&R Research
- Vol. 17 (5) , 847-859
Probability analysis of wind-driven natural ventilation potential in areaway-attached basements
- 1 June 2011
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 10 (1) , 19-30
Investigation of Ventilation Effectiveness for Wind-Driven Single-Sided Ventilated Buildings Located in an Urban Environment
This study employed large-eddy simulation (LES) to investigate wind-driven single-sided natural ventilation for an idealized building model located in an urban environment. Two ventilation cases, single-sided ventilation with an opening on the windward wall and with an opening on the leeward wall, were considered. The airflow rates through the single opening were calculated based on the mean flow fields and the transient flow fields, respectively. The comparisons showed that using only the information from the mean flow fields under-predicted the airflow rate and indicated the important role of fluctuating flow in the case of wind-driven single-sided ventilation. Using the homogeneous emission method, we further calculated the effective ventilation rates in the target indoor space and fairly good agreements were found in comparison with the measurements. The relationship between the airflow rate through the opening and the effective ventilation rate in the indoor space was studied by defining the ventilation efficiency for single-sided ventilation. This was 31.7% and 37.5% in the windward and leeward cases respectively, indicating a short-circuiting of fresh air at the opening. Based on a further analysis of the time-series data from LES, it was found that the variations of the airflow rate were significant while the variations of the effective ventilation rate were small.
- 1 June 2011
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 10 (1) , 19-30
Investigation of Ventilation Effectiveness for Wind-Driven Single-Sided Ventilated Buildings Located in an Urban Environment
This study employed large-eddy simulation (LES) to investigate wind-driven single-sided natural ventilation for an idealized building model located in an urban environment. Two ventilation cases, single-sided ventilation with an opening on the windward wall and with an opening on the leeward wall, were considered. The airflow rates through the single opening were calculated based on the mean flow fields and the transient flow fields, respectively. The comparisons showed that using only the information from the mean flow fields under-predicted the airflow rate and indicated the important role of fluctuating flow in the case of wind-driven single-sided ventilation. Using the homogeneous emission method, we further calculated the effective ventilation rates in the target indoor space and fairly good agreements were found in comparison with the measurements. The relationship between the airflow rate through the opening and the effective ventilation rate in the indoor space was studied by defining the ventilation efficiency for single-sided ventilation. This was 31.7% and 37.5% in the windward and leeward cases respectively, indicating a short-circuiting of fresh air at the opening. Based on a further analysis of the time-series data from LES, it was found that the variations of the airflow rate were significant while the variations of the effective ventilation rate were small.
- 1 April 2011
- Published by Elsevier in Building and Environment
- Vol. 46 (4) , 911-921
Wind-induced ventilation performances and airflow characteristics in an areaway-attached basement with a single-sided opening
- 1 April 2011
- Published by Elsevier in Building and Environment
- Vol. 46 (4) , 911-921
Wind-induced ventilation performances and airflow characteristics in an areaway-attached basement with a single-sided opening
- 1 March 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Experimental Investigation of Wind-Driven Natural Ventilation in an Areaway-Attached Basement: Wind Tunnel Measurements of Wind Pressures
This paper presents an experimental investigation of the wind-induced single-sided natural ventilation for an areaway attached basement. The experimental data in terms of wind pressure coefficients (Cp) were measured on both the external surfaces of the areaway space and internal surfaces of the basement space for the detached building pattern and the multi building pattern. Several parameters, including the presence of the above-ground building, wind incidence angle, areaway configurations, surrounding sheltering expressed by building coverage ratio, were studied. The power spectrum analysis was further performed to study the pressure characteristics at different sampling point positions. The results revealed the influences of the investigated parameters and can provide fundamental data for future ventilation investigations.
- 1 March 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Experimental Investigation of Wind-Driven Natural Ventilation in an Areaway-Attached Basement: Wind Tunnel Measurements of Wind Pressures
This paper presents an experimental investigation of the wind-induced single-sided natural ventilation for an areaway attached basement. The experimental data in terms of wind pressure coefficients (Cp) were measured on both the external surfaces of the areaway space and internal surfaces of the basement space for the detached building pattern and the multi building pattern. Several parameters, including the presence of the above-ground building, wind incidence angle, areaway configurations, surrounding sheltering expressed by building coverage ratio, were studied. The power spectrum analysis was further performed to study the pressure characteristics at different sampling point positions. The results revealed the influences of the investigated parameters and can provide fundamental data for future ventilation investigations.
- 1 February 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1510-1514
Evaluation of Local Wind Environment in a Dense Building Block Based on Exceedance Probability Analysis Method
This paper is devoted to study wind environment in a dense urban areas from the ventilation perspective. In order to take the stochastic characteristics of city wind into consideration, the exceedance probability analysis method was applied using air change rate as the index. The air change rate in the target domain was first obtained using CFD simulation for 16 wind directions and each building pattern. The CFD results demonstrated that airflow fields in the target domain were complicated and the air change rates depends greatly on wind direction. However, there is no direct correlation between street width and air change rate. The exceedance probability distributions were further calculated using the wind statistical data in Tokyo and used to analysis the influences of model orientation and street width. The results indicated that both factors affects the ventilation performance in the target domain significantly. The proposed evaluating approach is useful and effective for the urban ventilation design.
- 1 February 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1510-1514
Evaluation of Local Wind Environment in a Dense Building Block Based on Exceedance Probability Analysis Method
This paper is devoted to study wind environment in a dense urban areas from the ventilation perspective. In order to take the stochastic characteristics of city wind into consideration, the exceedance probability analysis method was applied using air change rate as the index. The air change rate in the target domain was first obtained using CFD simulation for 16 wind directions and each building pattern. The CFD results demonstrated that airflow fields in the target domain were complicated and the air change rates depends greatly on wind direction. However, there is no direct correlation between street width and air change rate. The exceedance probability distributions were further calculated using the wind statistical data in Tokyo and used to analysis the influences of model orientation and street width. The results indicated that both factors affects the ventilation performance in the target domain significantly. The proposed evaluating approach is useful and effective for the urban ventilation design.