Gabriel Thomas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gabriel Thomas has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Flores-Tapia
Electrical and Computer Engineering Department, University of Manitoba, Winnipeg, Manitoba, R3T 5V6 Canada. phone: (204) 474-6893, fax: (204) 261-4639
6 shared publications - Stephen Pistorius
University of Manitoba
5 shared publications - Abas Sabouni
University of Manitoba
2 shared publications - Ali Ashtari
Electrical and Computer Engineering Department, University of Manitoba, Winnipeg, Manitoba, R3T 5V6 Canada. phone: (204) 474-6893, fax: (204) 261-4639
2 shared publications Annamalai Manickavasagan
1 shared publication- Annamalai Manickavasagan
School of Engineering, University of Guelph, Guelph, Canada
1 shared publication
Latest Publications
- 1 January 2015
- Published by EJournal Publishing in Journal of Medical and Bioengineering
- Vol. 4 (1)
Back Propagation Neural Network (BPNN) to Detect Surface Crack on Dates Using RGB Images
- 1 January 2015
- Published by EJournal Publishing in Journal of Medical and Bioengineering
- Vol. 4 (1)
Back Propagation Neural Network (BPNN) to Detect Surface Crack on Dates Using RGB Images
- 16 May 2014
- Published by Springer Nature
- p. 191-204
Radio Frequency Imaging
- 24 February 2012
- Published by Springer Nature
- p. 135-145
Ultrasound Background Cancellation Based on Time-Varying Synthesis
- 24 February 2012
- Published by Springer Nature
- p. 135-145
Ultrasound Background Cancellation Based on Time-Varying Synthesis
- 10 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrical Insulation Magazine
- Vol. 26 (3) , 24-34
Synthetic aperture ultrasound imaging of XLPE insulation of underground power cables
Radar meets ultrasound; this article covers a new approach to testing underground power cable insulation in a nondestructive fashion. The possibilities and future potential of the combined use of two different imaging technologies are discussed.
- 10 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrical Insulation Magazine
- Vol. 26 (3) , 24-34
Synthetic aperture ultrasound imaging of XLPE insulation of underground power cables
Radar meets ultrasound; this article covers a new approach to testing underground power cable insulation in a nondestructive fashion. The possibilities and future potential of the combined use of two different imaging technologies are discussed.
- 22 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 54 (2) , 234-243
Heart Sound Cancellation Based on Multiscale Products and Linear Prediction
This paper presents a novel method for Heart Sound (HS) cancellation from Lung Sound (LS) records. The method uses the multiscale product of the wavelet coefficients of the original signal to detect HS-included segments. Once the HS segments are identified, the method removes them from the wavelet coefficients at every level and estimates the created gaps by using a set of linear prediction filters. It is shown that if the segment to be predicted is stationary, a final record with no audible artifacts such as clicks can be reconstructed using this approach. The results were promising for HS removal from LS records and showed no hampering of the main components of the LS. The results were confirmed both qualitatively by listening to the reconstructed signal and quantitatively by spectral analysis
- 22 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 54 (2) , 234-243
Heart Sound Cancellation Based on Multiscale Products and Linear Prediction
This paper presents a novel method for Heart Sound (HS) cancellation from Lung Sound (LS) records. The method uses the multiscale product of the wavelet coefficients of the original signal to detect HS-included segments. Once the HS segments are identified, the method removes them from the wavelet coefficients at every level and estimates the created gaps by using a set of linear prediction filters. It is shown that if the segment to be predicted is stationary, a final record with no audible artifacts such as clicks can be reconstructed using this approach. The results were promising for HS removal from LS records and showed no hampering of the main components of the LS. The results were confirmed both qualitatively by listening to the reconstructed signal and quantitatively by spectral analysis
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 2542-2545
3D Breast Microwave Imaging Based on Wavefront Reconstruction
Currently, breast cancer is the leading cause of cancer death in women between the ages of 15 and 54, and the second cause of cancer death in women 55 to 74. In recent years, Breast Microwave Imagery (BMI) has shown its potential as a promising breast cancer detection technique. This imaging technology is based on the electrical characteristic differences that exist between normal and malignant breast tissues at the microwave frequency range. A novel reconstruction approach for the formation of 3D BMI models is proposed in this paper. This technique uses the phase differences introduced during the collection of target responses in order to determine the correct spatial location of the different scatterers that constitute the final image. The proposed method yielded promising results when applied to simulated data
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 2542-2545
3D Breast Microwave Imaging Based on Wavefront Reconstruction
Currently, breast cancer is the leading cause of cancer death in women between the ages of 15 and 54, and the second cause of cancer death in women 55 to 74. In recent years, Breast Microwave Imagery (BMI) has shown its potential as a promising breast cancer detection technique. This imaging technology is based on the electrical characteristic differences that exist between normal and malignant breast tissues at the microwave frequency range. A novel reconstruction approach for the formation of 3D BMI models is proposed in this paper. This technique uses the phase differences introduced during the collection of target responses in order to determine the correct spatial location of the different scatterers that constitute the final image. The proposed method yielded promising results when applied to simulated data
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 4273-4276
Hybrid Microwave Tomography Technique for Breast Cancer Imaging
This paper addresses a two-dimensional inverse scattering method with a combination of tomography and radar methods for breast cancer detection. In order to rapidly construct high resolution images displaying the location, size, permittivity and conductivity of malignant tumors inside the body, the collected reflection from the scattered fields present in the scan area is segmented and their associated dielectric property maps are calculated. The dielectric profiles are obtained by using a technique that combines frequency domain finite difference time domain (FD)2TD analysis with genetic algorithm (GA) optimization. The applications of the proposed method can vary from medical imaging to nondestructive testing of materials and structures. The proposed technique yielded promising results when applied to simulated data
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 4273-4276
Hybrid Microwave Tomography Technique for Breast Cancer Imaging
This paper addresses a two-dimensional inverse scattering method with a combination of tomography and radar methods for breast cancer detection. In order to rapidly construct high resolution images displaying the location, size, permittivity and conductivity of malignant tumors inside the body, the collected reflection from the scattered fields present in the scan area is segmented and their associated dielectric property maps are calculated. The dielectric profiles are obtained by using a technique that combines frequency domain finite difference time domain (FD)2TD analysis with genetic algorithm (GA) optimization. The applications of the proposed method can vary from medical imaging to nondestructive testing of materials and structures. The proposed technique yielded promising results when applied to simulated data
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 4273-4276
Hybrid Microwave Tomography Technique for Breast Cancer Imaging
This paper addresses a two-dimensional inverse scattering method with a combination of tomography and radar methods for breast cancer detection. In order to rapidly construct high resolution images displaying the location, size, permittivity and conductivity of malignant tumors inside the body, the collected reflection from the scattered fields present in the scan area is segmented and their associated dielectric property maps are calculated. The dielectric profiles are obtained by using a technique that combines frequency domain finite difference time domain (FD)2TD analysis with genetic algorithm (GA) optimization. The applications of the proposed method can vary from medical imaging to nondestructive testing of materials and structures. The proposed technique yielded promising results when applied to simulated data
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 4273-4276
Hybrid Microwave Tomography Technique for Breast Cancer Imaging
This paper addresses a two-dimensional inverse scattering method with a combination of tomography and radar methods for breast cancer detection. In order to rapidly construct high resolution images displaying the location, size, permittivity and conductivity of malignant tumors inside the body, the collected reflection from the scattered fields present in the scan area is segmented and their associated dielectric property maps are calculated. The dielectric profiles are obtained by using a technique that combines frequency domain finite difference time domain (FD)2TD analysis with genetic algorithm (GA) optimization. The applications of the proposed method can vary from medical imaging to nondestructive testing of materials and structures. The proposed technique yielded promising results when applied to simulated data
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 2542-2545
3D Breast Microwave Imaging Based on Wavefront Reconstruction
Currently, breast cancer is the leading cause of cancer death in women between the ages of 15 and 54, and the second cause of cancer death in women 55 to 74. In recent years, Breast Microwave Imagery (BMI) has shown its potential as a promising breast cancer detection technique. This imaging technology is based on the electrical characteristic differences that exist between normal and malignant breast tissues at the microwave frequency range. A novel reconstruction approach for the formation of 3D BMI models is proposed in this paper. This technique uses the phase differences introduced during the collection of target responses in order to determine the correct spatial location of the different scatterers that constitute the final image. The proposed method yielded promising results when applied to simulated data
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 2542-2545
3D Breast Microwave Imaging Based on Wavefront Reconstruction
Currently, breast cancer is the leading cause of cancer death in women between the ages of 15 and 54, and the second cause of cancer death in women 55 to 74. In recent years, Breast Microwave Imagery (BMI) has shown its potential as a promising breast cancer detection technique. This imaging technology is based on the electrical characteristic differences that exist between normal and malignant breast tissues at the microwave frequency range. A novel reconstruction approach for the formation of 3D BMI models is proposed in this paper. This technique uses the phase differences introduced during the collection of target responses in order to determine the correct spatial location of the different scatterers that constitute the final image. The proposed method yielded promising results when applied to simulated data
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (08407789) , 1952-1955
Blind Image Restoration using the Cepstrum Method
Much research has been conducted on blind image restoration using the cepstrum method for degradations caused by out-of-focus and motion blurring due to the camera's focus settings and/or camera's motion that lead to a uniformly blurred image. The restoration of an image with a still background and a moving object is seldom addressed in the literature. This paper presents a method that extracts the blurred object from the background first, and then estimates the parameters of the PSF using the cepstrum method. Final restoration is achieved by using a classical Wiener filter. Experimental results show that the proposed method is able to achieve satisfactory restored images
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (08407789) , 1952-1955
Blind Image Restoration using the Cepstrum Method
Much research has been conducted on blind image restoration using the cepstrum method for degradations caused by out-of-focus and motion blurring due to the camera's focus settings and/or camera's motion that lead to a uniformly blurred image. The restoration of an image with a still background and a moving object is seldom addressed in the literature. This paper presents a method that extracts the blurred object from the background first, and then estimates the parameters of the PSF using the cepstrum method. Final restoration is achieved by using a classical Wiener filter. Experimental results show that the proposed method is able to achieve satisfactory restored images