Uttam Saha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Uttam Saha has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Leticia Sonon
Agricultural and Environmental Services Laboratories, University of Georgia Cooperative Extension, Athens, Georgia, USA
4 shared publications- Pamela R. Turner
Department of Financial Planning, Housing and Consumer Economics, College of Family and Consumer Sciences, The University of Georgia, 224 Hoke Smith Annex, Athens, GA 30602, USA
3 shared publications Derek Cooper
2 shared publications- Derek Cooper
Green Labs Program, University of Colorado Anschutz Medical Campus, 1945 North Wheeling Street, Aurora, CO 80045, USA
2 shared publications - Kushajveer Singh
Agricultural and Environmental Services Laboratories, College of Agricultural and Environmental Sciences, The University of Georgia, 2300-2400 College Station Road, Athens, GA 30602, USA
2 shared publications - Rebecca Cantrell
Department of Financial Planning, Housing and Consumer Economics, College of Family and Consumer Sciences, The University of Georgia, 224 Hoke Smith Annex, Athens, GA 30602, USA
2 shared publications
Latest Publications
- Open Access
- 1 April 2026
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 23 (4) , 450
Indoor Air Radon Testing Rate and Its Relationships with Various Socioeconomic and Public Health Factors in Georgia, USA
Radon (222Rn86), the second leading cause of lung cancer, is common in indoor air. However, radon testing is generally low throughout the US. In this study, we utilized 134,496 short-term indoor air radon test results from Georgia, USA. We investigated the association of the radon testing rate with a total of 104 different independent variables belonging to seven categories: (1) Demographic and Neighborhood Characteristics; (2) Housing Characteristics; (3) Literacy and Numeracy; (4) Employment and Economy; (5) Selected Social Factors; (6) Access to Computer/Internet; and (7) Status of Healthcare, Health, Well-being, and Lifestyle. We used Bivariate Correlation, Multivariate Ordinary Least Squares (OLS) Regression, and Factor Analysis, followed by factor score-based OLS regression. Significant negative associations of the testing rates were observed with population diversity, residential segregation, urban population density, younger population, housing age, household size, low literacy, unemployment, childcare cost burden, poverty, obesity, and the frequency of mentally and physically unhealthy days. In contrast, testing rates were positively associated with older population, home value, owner-occupied homes, higher literacy, higher institutional education, income, prevalence of social association, and life expectancy. The findings provide valuable insights for identifying the communities where socio-culturally relevant outreach activities would increase testing rates and minimize the public health consequences of environmental radon.
- 1 April 2026
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 23 (4) , 450
Open AccessIndoor Air Radon Testing Rate and Its Relationships with Various Socioeconomic and Public Health Factors in Georgia, USA
Radon (222Rn86), the second leading cause of lung cancer, is common in indoor air. However, radon testing is generally low throughout the US. In this study, we utilized 134,496 short-term indoor air radon test results from Georgia, USA. We investigated the association of the radon testing rate with a total of 104 different independent variables belonging to seven categories: (1) Demographic and Neighborhood Characteristics; (2) Housing Characteristics; (3) Literacy and Numeracy; (4) Employment and Economy; (5) Selected Social Factors; (6) Access to Computer/Internet; and (7) Status of Healthcare, Health, Well-being, and Lifestyle. We used Bivariate Correlation, Multivariate Ordinary Least Squares (OLS) Regression, and Factor Analysis, followed by factor score-based OLS regression. Significant negative associations of the testing rates were observed with population diversity, residential segregation, urban population density, younger population, housing age, household size, low literacy, unemployment, childcare cost burden, poverty, obesity, and the frequency of mentally and physically unhealthy days. In contrast, testing rates were positively associated with older population, home value, owner-occupied homes, higher literacy, higher institutional education, income, prevalence of social association, and life expectancy. The findings provide valuable insights for identifying the communities where socio-culturally relevant outreach activities would increase testing rates and minimize the public health consequences of environmental radon.
- Open Access
- 9 March 2026
- Published by MDPI AG in Preprints.org
Indoor Air Radon Testing Rate and Its Relationships with Various Socio-Economic and Public Health Factors in Georgia, USA
Radon (222Rn86), the second leading cause of lung cancer, is common in indoor air. However, radon testing is generally low throughout the US. In this study, we utilized 134,496 short-term indoor air radon test results from Georgia, USA. We investigated the association of the radon testing rate with a total of 104 different independent variables belonging to 7 categories: 1) Demographic and Neighborhood Characteristics; 2) Housing Characteristics; 3) Literacy and Numeracy; 4) Employment and Economy; 5) Selected Social Factors; 6) Access to Computer/Internet; and 7) Status of Healthcare, Health, Well-being, and Life-Style. We used Bivariate Correlation, Multivariate Ordinary Least Squares (OLS) Regression, and Factor Analysis followed by Factor-Score-based OLS regression. Significant negative associations of the testing rates were observed with population diversity, residential segregation, urban population density, younger population, housing age, household size, low-literacy, unemployment, childcare cost burden, poverty, obesity, and frequency of mental- and physical-unhealthy days. In contrast, testing rates were positively associated with older population, home value, owner-occupied homes, higher literacy, higher institutional education, income, prevalence of social association, and life expectancy. Findings provide valuable insights for identifying the communities where socio-culturally relevant outreach activities would increase testing rates and minimize public health consequences of environmental radon.
- 9 March 2026
- Published by MDPI AG in Preprints.org
Open AccessIndoor Air Radon Testing Rate and Its Relationships with Various Socio-Economic and Public Health Factors in Georgia, USA
Radon (222Rn86), the second leading cause of lung cancer, is common in indoor air. However, radon testing is generally low throughout the US. In this study, we utilized 134,496 short-term indoor air radon test results from Georgia, USA. We investigated the association of the radon testing rate with a total of 104 different independent variables belonging to 7 categories: 1) Demographic and Neighborhood Characteristics; 2) Housing Characteristics; 3) Literacy and Numeracy; 4) Employment and Economy; 5) Selected Social Factors; 6) Access to Computer/Internet; and 7) Status of Healthcare, Health, Well-being, and Life-Style. We used Bivariate Correlation, Multivariate Ordinary Least Squares (OLS) Regression, and Factor Analysis followed by Factor-Score-based OLS regression. Significant negative associations of the testing rates were observed with population diversity, residential segregation, urban population density, younger population, housing age, household size, low-literacy, unemployment, childcare cost burden, poverty, obesity, and frequency of mental- and physical-unhealthy days. In contrast, testing rates were positively associated with older population, home value, owner-occupied homes, higher literacy, higher institutional education, income, prevalence of social association, and life expectancy. Findings provide valuable insights for identifying the communities where socio-culturally relevant outreach activities would increase testing rates and minimize public health consequences of environmental radon.
- Open Access
- 6 December 2025
- Published by Elsevier in Indoor Environments
- Vol. 2 (4)
An analysis of the impact of geology on indoor air radon concentration
- 6 December 2025
- Published by Elsevier in Indoor Environments
- Vol. 2 (4)
Open AccessAn analysis of the impact of geology on indoor air radon concentration
- Open Access
- 4 September 2023
- Published by European Radon Association in Journal of the European Radon Association
Long-term evaluation of a reusable radon-in-water proficiency test
A proficiency test is an integral part of any analytical procedure; however, there is no known proficiency test in place for radon-in-water analysis. This led us to conduct a long-term study. Successful preparation of a reusable radon (222Rn)-in-water standard containing a ‘radium (226Ra)-loaded filter paper (the source)’ sandwiched between polyethylene sheeting has been reported. As the source ‘226Ra-loaded filter paper’ is sandwiched between polyethylene sheets, the surrounding water (which is sampled and analyzed) in the bottle remains free of 226Ra. With this type of standards, a previous study reported that at full ingrowth (>30 days), 86% of the 222Rn produced by the source was emanated into the water and remained stable thereafter, and the remaining 14% was retarded by the polyethylene sheeting. We periodically measured radon-in-water in two such standard samples allowing a 40- to 50-day ingrowth interval for more than 6 years (2016–2022). In each measurement, we prepared in duplicate the cocktails in four different ways (in Mineral-oil vs. Optifluor in combination with two different ways of ‘pipetting or sample drawing’ and dispensing into the scintillation vials) and measured the radon-in-water using two different Liquid Scintillation Counting (LSC) assays: full-spectrum (0–2,000 keV) versus Region of Interest (ROI) for radon (ROI, 130–700 keV). A substantial number of repeated results unequivocally show that the reusable standards maintained its characteristics satisfactorily for a 6-year long period. Duplicate measurements were precise in almost all cases. We consistently observed significant differences in measured radon concentration between the two different LSC assays and between the two different scintillation fluids, but not between the two sample drawing methods. With full-spectrum assay (0–2,000 keV), both Mineral-oil and Optifluor grossly underestimated the actual radon concentration, and with ROI assay (130–700 keV), Mineral-oil overestimated the radon concentration; therefore, these should be avoided. Preparing the cocktails with Optifluor and measuring by ROI assay (130–700 keV) was the only method that consistently produced results within the acceptance window (±25% of the known), suggesting that a certain way of preparing and measuring the water samples could yield more accurate results for radon. Thus, our findings demonstrate that a proficiency test for radon-in-water using these reusable 226Ra-free radon-in-water standards is a valid and valuable option, and it should be a part of radon-in-water analysis by the laboratories.
- 4 September 2023
- Published by European Radon Association in Journal of the European Radon Association
Open AccessLong-term evaluation of a reusable radon-in-water proficiency test
A proficiency test is an integral part of any analytical procedure; however, there is no known proficiency test in place for radon-in-water analysis. This led us to conduct a long-term study. Successful preparation of a reusable radon (222Rn)-in-water standard containing a ‘radium (226Ra)-loaded filter paper (the source)’ sandwiched between polyethylene sheeting has been reported. As the source ‘226Ra-loaded filter paper’ is sandwiched between polyethylene sheets, the surrounding water (which is sampled and analyzed) in the bottle remains free of 226Ra. With this type of standards, a previous study reported that at full ingrowth (>30 days), 86% of the 222Rn produced by the source was emanated into the water and remained stable thereafter, and the remaining 14% was retarded by the polyethylene sheeting. We periodically measured radon-in-water in two such standard samples allowing a 40- to 50-day ingrowth interval for more than 6 years (2016–2022). In each measurement, we prepared in duplicate the cocktails in four different ways (in Mineral-oil vs. Optifluor in combination with two different ways of ‘pipetting or sample drawing’ and dispensing into the scintillation vials) and measured the radon-in-water using two different Liquid Scintillation Counting (LSC) assays: full-spectrum (0–2,000 keV) versus Region of Interest (ROI) for radon (ROI, 130–700 keV). A substantial number of repeated results unequivocally show that the reusable standards maintained its characteristics satisfactorily for a 6-year long period. Duplicate measurements were precise in almost all cases. We consistently observed significant differences in measured radon concentration between the two different LSC assays and between the two different scintillation fluids, but not between the two sample drawing methods. With full-spectrum assay (0–2,000 keV), both Mineral-oil and Optifluor grossly underestimated the actual radon concentration, and with ROI assay (130–700 keV), Mineral-oil overestimated the radon concentration; therefore, these should be avoided. Preparing the cocktails with Optifluor and measuring by ROI assay (130–700 keV) was the only method that consistently produced results within the acceptance window (±25% of the known), suggesting that a certain way of preparing and measuring the water samples could yield more accurate results for radon. Thus, our findings demonstrate that a proficiency test for radon-in-water using these reusable 226Ra-free radon-in-water standards is a valid and valuable option, and it should be a part of radon-in-water analysis by the laboratories.
- 15 March 2018
- Published by Wiley in Journal of the Science of Food and Agriculture
- Vol. 98 (11) , 4253-4267
Near‐infrared spectroscopic models for analysis of winter pea (Pisum sativum L.) quality constituents
BACKGROUND: Winter pea (Pisum sativum L.) grows well in a wide geographic region, both as a forage and cover crop. Understanding the quality constituents of this crop is important for both end uses; however, analysis of quality constituents by conventional wet chemistry methods is laborious, slow and costly. Near infrared reflectance spectroscopy (NIRS) is a precise, accurate, rapid and cheap alternative to using wet chemistry for estimating quality constituents. We developed and validated NIRS calibration models for constituent analysis of this crop.RESULTS: Of the 11 constituent models developed, nine constituents including moisture, dry‐matter, total‐nitrogen, crude protein, acid detergent fiber, neutral detergent fiber, AD‐lignin, cellulose and non‐fibrous carbohydrate had low standard errors and a high coefficient of determination (R2 = 0.88–0.98; 1 – VR, which is the coefficient of determination during cross‐validation = 0.77–0.92) for both calibration and cross‐validation, indicating their potential for quantitative predictability. The calibration models for ash (R2 = 0.65; 1 – VR = 0.46) and hemicellulose (R2 = 0.75; 1 – VR = 0.50) also appeared to be adequate for qualitative screening. Predictions of an independent validation set yielded reliable agreement between the NIRS predicted values and the reference values with low standard error of prediction (SEP), low bias, high coefficient of determination (r2 = 0.82‐0.95), high ratios of performance to deviation (RPD = SD/SEP; 2.30–3.85) and high ratios of performance to interquartile distance (RPIQ = IQ/SEP; 2.57–7.59) for all 11 constituents.CONCLUSION: Precise, accurate and rapid analysis of winter pea for major forage and cover crop quality constituents can be performed at a low cost using the NIRS calibration models developed. © 2018 Society of Chemical Industry
- 15 March 2018
- Published by Wiley in Journal of the Science of Food and Agriculture
- Vol. 98 (11) , 4253-4267
Near‐infrared spectroscopic models for analysis of winter pea (Pisum sativum L.) quality constituents
BACKGROUND: Winter pea (Pisum sativum L.) grows well in a wide geographic region, both as a forage and cover crop. Understanding the quality constituents of this crop is important for both end uses; however, analysis of quality constituents by conventional wet chemistry methods is laborious, slow and costly. Near infrared reflectance spectroscopy (NIRS) is a precise, accurate, rapid and cheap alternative to using wet chemistry for estimating quality constituents. We developed and validated NIRS calibration models for constituent analysis of this crop.RESULTS: Of the 11 constituent models developed, nine constituents including moisture, dry‐matter, total‐nitrogen, crude protein, acid detergent fiber, neutral detergent fiber, AD‐lignin, cellulose and non‐fibrous carbohydrate had low standard errors and a high coefficient of determination (R2 = 0.88–0.98; 1 – VR, which is the coefficient of determination during cross‐validation = 0.77–0.92) for both calibration and cross‐validation, indicating their potential for quantitative predictability. The calibration models for ash (R2 = 0.65; 1 – VR = 0.46) and hemicellulose (R2 = 0.75; 1 – VR = 0.50) also appeared to be adequate for qualitative screening. Predictions of an independent validation set yielded reliable agreement between the NIRS predicted values and the reference values with low standard error of prediction (SEP), low bias, high coefficient of determination (r2 = 0.82‐0.95), high ratios of performance to deviation (RPD = SD/SEP; 2.30–3.85) and high ratios of performance to interquartile distance (RPIQ = IQ/SEP; 2.57–7.59) for all 11 constituents.CONCLUSION: Precise, accurate and rapid analysis of winter pea for major forage and cover crop quality constituents can be performed at a low cost using the NIRS calibration models developed. © 2018 Society of Chemical Industry
- 2 January 2018
- Published by Taylor & Francis in Communications in Soil Science and Plant Analysis
- Vol. 49 (1) , 63-75
A Comparison of Diffusion-Conductimetric and Distillation-Titration Methods in Analyzing Ammonium- and Nitrate-Nitrogen in the KCl-Extracts of Georgia Soils
Soil mineral (or inorganic) nitrogen (SMN), which primarily exists as exchangeable and soluble ammonium (NH4+) and the nitrate (NO3−) ions, represents readily available nitrogen for plant growth. Over the years a 2M potassium chloride (KCl) solution has become the extraction solution of choice for extracting SMN. In the research and service laboratories, either distillation-titration method (DTM) or colorimetric method (CM) is virtually the standard to measure NH4+- and NO3−-N in the 2M KCl soil extracts. However, being a time-consuming and labor intensive method, DTM generally has a very low throughput. Likewise, CM is affected by interferences from pH variation, color, turbidity, presence of organic species, and some other constituents in the extracts. In contrast, diffusion conductivity method (DCM) is a less expensive and high throughput one, which is also relatively free from common interferences. In this study, we, therefore, compared the extraction efficiency of various KCl concentrations and performance of diffusion conductivity method (DCM) with DTM in measuring NH4+-N and NO3−-N in KCl extracts of 32 agricultural soils of Georgia. A 0.2M KCl solution extracted statistically similar amounts of NH4+-N and NO3−-N as did 2M KCl, suggesting that a 10-fold dilute KCl solution than the standard 2M KCl might be good enough to extract and estimate the most of SMN. For the analyses of NH4+- and NO3−-N in the KCl extracts, the DCM produced results statistically similar to those produced by DTM. The deviation between the results given by DCM and DTM was no more than ±10%. Thus, DCM appears to be an attractive alternative to the labor intensive and time-consuming DTM for measuring NH4+- and NO3−-N in the KCl extract of soils in the research and service laboratories.
- 2 January 2018
- Published by Taylor & Francis in Communications in Soil Science and Plant Analysis
- Vol. 49 (1) , 63-75
A Comparison of Diffusion-Conductimetric and Distillation-Titration Methods in Analyzing Ammonium- and Nitrate-Nitrogen in the KCl-Extracts of Georgia Soils
Soil mineral (or inorganic) nitrogen (SMN), which primarily exists as exchangeable and soluble ammonium (NH4+) and the nitrate (NO3−) ions, represents readily available nitrogen for plant growth. Over the years a 2M potassium chloride (KCl) solution has become the extraction solution of choice for extracting SMN. In the research and service laboratories, either distillation-titration method (DTM) or colorimetric method (CM) is virtually the standard to measure NH4+- and NO3−-N in the 2M KCl soil extracts. However, being a time-consuming and labor intensive method, DTM generally has a very low throughput. Likewise, CM is affected by interferences from pH variation, color, turbidity, presence of organic species, and some other constituents in the extracts. In contrast, diffusion conductivity method (DCM) is a less expensive and high throughput one, which is also relatively free from common interferences. In this study, we, therefore, compared the extraction efficiency of various KCl concentrations and performance of diffusion conductivity method (DCM) with DTM in measuring NH4+-N and NO3−-N in KCl extracts of 32 agricultural soils of Georgia. A 0.2M KCl solution extracted statistically similar amounts of NH4+-N and NO3−-N as did 2M KCl, suggesting that a 10-fold dilute KCl solution than the standard 2M KCl might be good enough to extract and estimate the most of SMN. For the analyses of NH4+- and NO3−-N in the KCl extracts, the DCM produced results statistically similar to those produced by DTM. The deviation between the results given by DCM and DTM was no more than ±10%. Thus, DCM appears to be an attractive alternative to the labor intensive and time-consuming DTM for measuring NH4+- and NO3−-N in the KCl extract of soils in the research and service laboratories.
- 12 October 2017
- Published by Wiley in Journal of the Science of Food and Agriculture
- Vol. 98 (5) , 1821-1831
Analysis of moisture, oil, and fatty acid composition of olives by near‐infrared spectroscopy: development and validation calibration models
BACKGROUND: Olive is a new, expanding crop in Georgia. Its oil content steadily increases with maturity, but eventually plateaus at the maximum when the olives should be promptly harvested, avoiding overripening and quality degradation. This requires frequent testing. However, olive quality analysis by wet chemistry is laborious, slow and costly, whereas near‐infrared reflectance spectroscopy (NIRS), being precise, accurate, rapid and cheap, could be suitable. We developed and validated NIRS calibration models for moisture, fresh‐matter‐oil (oil‐FMO), dry‐matter‐oil (oil‐DMO) and major fatty acid composition analyses.RESULTS: Of the12 models developed, seven constituents – moisture, oil‐FMO, oil‐DMO, and palmitic, palmitoleic, oleic and linoleic acids (representing 88–97% of the total fatty acids) had low standard errors and high coefficients of determination (R2 = 0.81–0.98; 1 − VR = 0.74–0.86) for both calibration and cross‐validation. For these seven constituents, predictions of an independent validation set yielded excellent agreement between the NIRS predicted values and the reference values with low standard error of prediction (SEP), low bias, high coefficient of determination (r2 = 0.80–0.93) and high ratios of performance to deviation (RPD = SD/SEP; 2.21–3.85).CONCLUSION: Precise, accurate and rapid analysis of fresh olives for moisture, oil and major fatty acid composition can be done at a low cost using NIRS, meeting the analytical needs of the industry. © 2017 Society of Chemical Industry
- 12 October 2017
- Published by Wiley in Journal of the Science of Food and Agriculture
- Vol. 98 (5) , 1821-1831
Analysis of moisture, oil, and fatty acid composition of olives by near‐infrared spectroscopy: development and validation calibration models
BACKGROUND: Olive is a new, expanding crop in Georgia. Its oil content steadily increases with maturity, but eventually plateaus at the maximum when the olives should be promptly harvested, avoiding overripening and quality degradation. This requires frequent testing. However, olive quality analysis by wet chemistry is laborious, slow and costly, whereas near‐infrared reflectance spectroscopy (NIRS), being precise, accurate, rapid and cheap, could be suitable. We developed and validated NIRS calibration models for moisture, fresh‐matter‐oil (oil‐FMO), dry‐matter‐oil (oil‐DMO) and major fatty acid composition analyses.RESULTS: Of the12 models developed, seven constituents – moisture, oil‐FMO, oil‐DMO, and palmitic, palmitoleic, oleic and linoleic acids (representing 88–97% of the total fatty acids) had low standard errors and high coefficients of determination (R2 = 0.81–0.98; 1 − VR = 0.74–0.86) for both calibration and cross‐validation. For these seven constituents, predictions of an independent validation set yielded excellent agreement between the NIRS predicted values and the reference values with low standard error of prediction (SEP), low bias, high coefficient of determination (r2 = 0.80–0.93) and high ratios of performance to deviation (RPD = SD/SEP; 2.21–3.85).CONCLUSION: Precise, accurate and rapid analysis of fresh olives for moisture, oil and major fatty acid composition can be done at a low cost using NIRS, meeting the analytical needs of the industry. © 2017 Society of Chemical Industry
- 18 July 2017
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 25 (4) , 242-255
Prediction of calorific values, moisture, ash, carbon, nitrogen, and sulfur content of pine tree biomass using near infrared spectroscopy
Loblolly ( Pinus taeda) and slash ( Pinus elliottii) pine tree biomass are significant renewable energy resources for bioenergy industries in the Southeastern United States. There is a great need for evaluation of their properties (relevant to production and evaluation-screening for bioenergy extraction) by rapid but accurate analytical methods like near infrared reflectance (NIR) spectroscopy. However, no attempts have been made so far to develop useful NIR spectroscopic calibration models for analyzing biomass of these two species. In this study, acceptable NIR spectroscopic calibration models were developed for: gross calorific value, GCV ( n = 181; R2 = 0.83; ratio of standard error of cross-validation to deviation, RSCD = 2.32; ratio of standard error of cross-validation to inter-quartile distance, RSCIQ = 2.68); net calorific value, NCV ( n = 184; R2 = 0.83; RSCD = 2.31; RSCIQ = 2.69); ash-free calorific value, AFCV ( n = 184; R2 = 0.83; RSCD = 2.24; RSCIQ = 2.49); moisture ( n = 181; R2 = 0.85; RSCD = 2.54; RSCIQ = 2.30); ash ( n = 180; R2 = 0.86; RSCD = 2.65; RSCIQ = 2.62); total carbon, C ( n = 101; R2 = 0.95; RSCD = 3.01; RSCIQ = 5.66); total nitrogen, N ( n = 87; R2 = 0.95; RSCD = 4.24; RSCIQ = 4.76); and total sulfur, S ( n = 83; R2 = 0.97; RSCD = 4.17; RSCIQ = 3.05) contents of these biomasses though the calibration models for NCV and AFCV are indirect calibration. Prediction of the independent validation sets yielded good agreement between the NIR spectroscopic predicted values and the laboratory reference values for each of: GCV ( n = 92; r2 = 0.89; ratio of performance to deviation; RPD = 3.01; ratio of performance to inter-quartile distance, RPIQ = 3.16); NCV ( n = 91; r2 = 0.83; RPD = 2.43; RPIQ = 3.06); AFCV ( n = 91; r2 = 0.80; RPD = 2.25; RPIQ = 2.83); moisture ( n = 92; r2 = 0.82; RPD = 2.38; RPIQ = 2.40); ash ( n = 89; r2 = 0.81; RPD = 2.30; RPIQ = 2.66); C ( n = 43; r2 = 0.90; RPD = 3.14; RPIQ = 3.23); N ( n = 44; r2 = 0.95; RPD = 4.33; RPIQ = 5.96); and S ( n = 42; r2 = 0.93; RPD = 3.67; RPIQ = 3.24) contents, indicating that all eight calibration models had good quantitative information. The standard errors of prediction for all models were less than twice the corresponding standard error of laboratory. Therefore, precise, accurate, and rapid analysis of calorific values and C, N, S contents of these biomasses can be done using these novel NIR spectroscopic calibration models developed.
- 18 July 2017
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 25 (4) , 242-255
Prediction of calorific values, moisture, ash, carbon, nitrogen, and sulfur content of pine tree biomass using near infrared spectroscopy
Loblolly ( Pinus taeda) and slash ( Pinus elliottii) pine tree biomass are significant renewable energy resources for bioenergy industries in the Southeastern United States. There is a great need for evaluation of their properties (relevant to production and evaluation-screening for bioenergy extraction) by rapid but accurate analytical methods like near infrared reflectance (NIR) spectroscopy. However, no attempts have been made so far to develop useful NIR spectroscopic calibration models for analyzing biomass of these two species. In this study, acceptable NIR spectroscopic calibration models were developed for: gross calorific value, GCV ( n = 181; R2 = 0.83; ratio of standard error of cross-validation to deviation, RSCD = 2.32; ratio of standard error of cross-validation to inter-quartile distance, RSCIQ = 2.68); net calorific value, NCV ( n = 184; R2 = 0.83; RSCD = 2.31; RSCIQ = 2.69); ash-free calorific value, AFCV ( n = 184; R2 = 0.83; RSCD = 2.24; RSCIQ = 2.49); moisture ( n = 181; R2 = 0.85; RSCD = 2.54; RSCIQ = 2.30); ash ( n = 180; R2 = 0.86; RSCD = 2.65; RSCIQ = 2.62); total carbon, C ( n = 101; R2 = 0.95; RSCD = 3.01; RSCIQ = 5.66); total nitrogen, N ( n = 87; R2 = 0.95; RSCD = 4.24; RSCIQ = 4.76); and total sulfur, S ( n = 83; R2 = 0.97; RSCD = 4.17; RSCIQ = 3.05) contents of these biomasses though the calibration models for NCV and AFCV are indirect calibration. Prediction of the independent validation sets yielded good agreement between the NIR spectroscopic predicted values and the laboratory reference values for each of: GCV ( n = 92; r2 = 0.89; ratio of performance to deviation; RPD = 3.01; ratio of performance to inter-quartile distance, RPIQ = 3.16); NCV ( n = 91; r2 = 0.83; RPD = 2.43; RPIQ = 3.06); AFCV ( n = 91; r2 = 0.80; RPD = 2.25; RPIQ = 2.83); moisture ( n = 92; r2 = 0.82; RPD = 2.38; RPIQ = 2.40); ash ( n = 89; r2 = 0.81; RPD = 2.30; RPIQ = 2.66); C ( n = 43; r2 = 0.90; RPD = 3.14; RPIQ = 3.23); N ( n = 44; r2 = 0.95; RPD = 4.33; RPIQ = 5.96); and S ( n = 42; r2 = 0.93; RPD = 3.67; RPIQ = 3.24) contents, indicating that all eight calibration models had good quantitative information. The standard errors of prediction for all models were less than twice the corresponding standard error of laboratory. Therefore, precise, accurate, and rapid analysis of calorific values and C, N, S contents of these biomasses can be done using these novel NIR spectroscopic calibration models developed.
- Open Access
- 17 June 2016
- Published by Science Publishing Group in International Journal of Applied Agricultural Sciences
- Vol. 2 (4) , 69-74
The Effect of Drought on Lignin Content and Digestibility of Tifton-85 and Coastal Bermudagrass ( Cynodon dactylon L.) Hays Produced in Georgia
Digestibility of “Tifton 85” Bermudagrass has been noted to be higher than most other Bermudagrass cultivars. However, the superior digestibility of Tifton-85 has not been verified based on samples from producers, nor is it known how water availability might affect this comparison. Recent past weather conditions in Georgia allowed this comparison. Much of Georgia was in severe drought in 2007 and 2008. In contrast, there was less/no drought in 2006 and 2009. In each of these years, producers submitted a substantial number of Tifton-85 and Coastal forage samples to our laboratory for lignin and “Digestible Neutral Detergent Fiber (dNDF48)” analyses. Over all years, Tifton-85 had lower lignin content than coastal. However, Tifton-85 had significantly lower lignin content only in drought free 2006 and 2009, whereas the lignin content of Coastal was unaffected by drought in 2007 and 2008. The lignin of Tifton-85 increased during these two drought years. Despite this, the dNDF48 for Tifton-85 was significantly higher than coastal in all four years, suggesting that drought had hardly any effect on the digestibility of Tifton-85. Apparently, the type of lignin in Tifton-85 is different from that in coastal. Higher dNDF48 for Tifton-85 has been attributed to its lower concentrations of ether-linked ferulic acid than in Coastal. Decreased ether bonding in lignin results in higher digestion.
- 17 June 2016
- Published by Science Publishing Group in International Journal of Applied Agricultural Sciences
- Vol. 2 (4) , 69-74
Open AccessThe Effect of Drought on Lignin Content and Digestibility of Tifton-85 and Coastal Bermudagrass ( Cynodon dactylon L.) Hays Produced in Georgia
Digestibility of “Tifton 85” Bermudagrass has been noted to be higher than most other Bermudagrass cultivars. However, the superior digestibility of Tifton-85 has not been verified based on samples from producers, nor is it known how water availability might affect this comparison. Recent past weather conditions in Georgia allowed this comparison. Much of Georgia was in severe drought in 2007 and 2008. In contrast, there was less/no drought in 2006 and 2009. In each of these years, producers submitted a substantial number of Tifton-85 and Coastal forage samples to our laboratory for lignin and “Digestible Neutral Detergent Fiber (dNDF48)” analyses. Over all years, Tifton-85 had lower lignin content than coastal. However, Tifton-85 had significantly lower lignin content only in drought free 2006 and 2009, whereas the lignin content of Coastal was unaffected by drought in 2007 and 2008. The lignin of Tifton-85 increased during these two drought years. Despite this, the dNDF48 for Tifton-85 was significantly higher than coastal in all four years, suggesting that drought had hardly any effect on the digestibility of Tifton-85. Apparently, the type of lignin in Tifton-85 is different from that in coastal. Higher dNDF48 for Tifton-85 has been attributed to its lower concentrations of ether-linked ferulic acid than in Coastal. Decreased ether bonding in lignin results in higher digestion.
- 16 July 2012
- Published by Taylor & Francis in Communications in Soil Science and Plant Analysis
- Vol. 43 (18) , 2323-2341
Comparison of Conductimetric and Colorimetric Methods with Distillation–Titration Method of Analyzing Ammonium Nitrogen in Total Kjeldahl Digests
The distillation–titration method (DTM) is a standard procedure used by most laboratories to measure ammonium-nitrogen (NH4-N) in the total Kjeldahl N (TKN) digests of various kinds of agricultural and environmental samples. These samples may have TKN contents ranging from less than 100 ppb to as high as percentage levels. However, the DTM procedure generally leads to a very low throughput because it is labor intensive and time-consuming. At the current practical quantitation limit (PQL) of 300 ppb established at the Feed and Environmental (FEW) Laboratory, University of Georgia, the DTM procedure is less applicable to low TKN surface water samples. In this study, we therefore compared the performance of diffusion conductivity method (DCM) and colorimetric method (CM) with DTM in measuring NH4-N in the TKN digests of 29 different samples representing surface waters, lagoons, manures, poultry litters, and environmental wastes. Acceptable accuracy and precision were achieved for various QC samples by all three methods. For widely different sample matrices and TKN contents, the NH4-N in the TKN digests measured by DCM and CM both agreed well with that measured by DTM. However, the linear working range of CM is limited within 0.2 to 5.0 ppm, whereas DCM is linear at a wider range of 0.01 to 2000 ppm. With DCM, the PQL of TKN is at 13 ppb, much less than the 300 ppb in DTM and 520 ppb in CM. Both DCM and CM require increasing the pH of the working TKN digest to a highly alkaline range. To meet such pH requirement, the minimum dilution need for DCM is twofold, where as that CM is fourfold. Because of greater mandatory dilution requirement coupled with a greater PQL, CM may often fail to measure NH4-N in the working TKN digest of some low TKN surface water samples. On the other hand, with some environmental waste samples containing TKN at percentage level, CM would require multistep dilution of the digests prior to measurement, thus allowing dilution-related error as well as requiring additional labor. In contrast, DCM can measure both low TKN surface waters and high TKN environmental wastes without any major limitations. Moreover, DCM may work well without any adjustment of sample background in the calibration standards. Thus DCM appears to be an attractive alternative to the labor-intensive and time-consuming DTM for measuring NH4-N in the TKN digests of various kinds of agricultural and environmental samples in the analytical services laboratories.
- 16 July 2012
- Published by Taylor & Francis in Communications in Soil Science and Plant Analysis
- Vol. 43 (18) , 2323-2341
Comparison of Conductimetric and Colorimetric Methods with Distillation–Titration Method of Analyzing Ammonium Nitrogen in Total Kjeldahl Digests
The distillation–titration method (DTM) is a standard procedure used by most laboratories to measure ammonium-nitrogen (NH4-N) in the total Kjeldahl N (TKN) digests of various kinds of agricultural and environmental samples. These samples may have TKN contents ranging from less than 100 ppb to as high as percentage levels. However, the DTM procedure generally leads to a very low throughput because it is labor intensive and time-consuming. At the current practical quantitation limit (PQL) of 300 ppb established at the Feed and Environmental (FEW) Laboratory, University of Georgia, the DTM procedure is less applicable to low TKN surface water samples. In this study, we therefore compared the performance of diffusion conductivity method (DCM) and colorimetric method (CM) with DTM in measuring NH4-N in the TKN digests of 29 different samples representing surface waters, lagoons, manures, poultry litters, and environmental wastes. Acceptable accuracy and precision were achieved for various QC samples by all three methods. For widely different sample matrices and TKN contents, the NH4-N in the TKN digests measured by DCM and CM both agreed well with that measured by DTM. However, the linear working range of CM is limited within 0.2 to 5.0 ppm, whereas DCM is linear at a wider range of 0.01 to 2000 ppm. With DCM, the PQL of TKN is at 13 ppb, much less than the 300 ppb in DTM and 520 ppb in CM. Both DCM and CM require increasing the pH of the working TKN digest to a highly alkaline range. To meet such pH requirement, the minimum dilution need for DCM is twofold, where as that CM is fourfold. Because of greater mandatory dilution requirement coupled with a greater PQL, CM may often fail to measure NH4-N in the working TKN digest of some low TKN surface water samples. On the other hand, with some environmental waste samples containing TKN at percentage level, CM would require multistep dilution of the digests prior to measurement, thus allowing dilution-related error as well as requiring additional labor. In contrast, DCM can measure both low TKN surface waters and high TKN environmental wastes without any major limitations. Moreover, DCM may work well without any adjustment of sample background in the calibration standards. Thus DCM appears to be an attractive alternative to the labor-intensive and time-consuming DTM for measuring NH4-N in the TKN digests of various kinds of agricultural and environmental samples in the analytical services laboratories.