SDSerdar Doğruel

Serdar Doğruel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Serdar Doğruel has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Degradation and ecotoxicity of favipiravir and oseltamivir in the presence of microplastics during ozonation and catalytic ozonation of synthetic municipal wastewater effluents

    by Serdar Dogruel, Nasim Chavoshi, Nilay Bilgin‐Saritas, Alireza Khataee, Emel Topuz, Elif Pehlivanoglu

    Background: Favipiravir (FAV) and oseltamivir (OSE) are antiviral agents developed against influenza and they were repurposed against SARS‐CoV‐2 during the COVID‐19 pandemic. This study evaluated the potential of ozonation and catalytic ozonation as tertiary treatment approaches for removing FAV and OSE from municipal wastewaters, both in the presence and absence of microplastics (MPs), while comparing the ecotoxicity of untreated and treated secondary effluents to predict the ecotoxicological effects of these technologies during municipal wastewater treatment.Results: At an initial antiviral concentration of 50 μg L−1, ozonation at pH 7 with a specific ozone dose of 0.6 mg O3 (mg DOC)−1 yielded FAV and OSE removals of 84 and 64%, respectively, while the presence of catalyst or MPs decreased the degradation rate by 30–40%. Raising the pH to 10 had minimal impact on FAV abatement, but improved OSE reduction by 21%. Acute toxicity tests using Vibrio fischeri demonstrated that simultaneous ozonation of the analytes led to the accumulation of transformation products (TPs) of FAV and OSE, with their combined effect almost equal to that of the original compounds. Reproduction toxicity tests indicated that TPs of antiviral drugs generated during ozonation were less toxic to Enchytraeus crypticus than the parent chemicals.Conclusion: Ozonation proved to be a viable option for upgrading existing wastewater treatment facilities, serving as a complementary treatment to minimize the release of antivirals from municipal secondary effluents and reduce their inhibitory effect on earthworm reproduction, thereby enhancing the reuse potential of treated wastewater for irrigation. © 2025 The Author(s). Journal of Chemical Technology and Biotechnology published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry (SCI).


  • Open Access

    Analysis of particle size distribution of organic carbon for landfill leachate—implications for sustainable treatment

    by Serdar Doğruel, Beste Kaya, Dilşad Soylu, Emine Çokgör, Aydın Baran, Seval Sözen, Derin Orhon

    BACKGROUND: Landfill leachate has a complex composition requiring experimental support to formulate a sustainable treatment strategy. This study utilized the particle size distribution (PSD) of the chemical oxygen demand (COD) content to assess the profile of biodegradable and inert COD fractions; it also emphasized the functions and benefits of ultrafiltration and nanofiltration modules coupled to an activated sludge process. The evaluation profited from the field data of a landfill site in Istanbul, where the leachate was actually treated in a membrane bioreactor (MBR) plant.RESULTS: COD and total nitrogen levels fluctuated between 10 100–31 200 mg L−1 and 1150–2800 mg L−1, respectively. PSD analysis for COD, conducted at two extremes, displayed similar results, where the majority of the COD was observed to accumulate at the low extremity of the particle size, 70–72% below 2 nm. Therefore, direct membrane filtration of leachate yielded low COD removals that were limited to 9% with ultrafiltration and to 31–35% with nanofiltration. COD fractionation indicated a ratio of 5% for the inert COD in leachate. The permeate COD of ultrafiltration in the existing plant was 2000 mg L−1, much higher than the inert fraction ratio, which was further reduced to 266 mg L−1 by nanofiltration.CONCLUSION: PSD analysis was an integral complement of respirometry for establishing the size‐biodegradation relationships of different COD fractions. It located the majority of soluble COD fractions below 0.55 nm, thus implying the necessity of a biological process. PSD also identified the generation of soluble residual metabolic products, indicating that residual COD escaping treatment would be equally significant to the removal potential of the biodegradable substrate. © 2023 The Authors. Journal of Chemical Technology and Biotechnology published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry (SCI).


  • Anatomy of chemically enhanced sewage settling by particle size distribution analysis

    by Seyda Duba, Seval Sözen, Serdar Dogruel, Tugba Olmez‐Hanci, Goksin Ozyildiz, Emine Cokgor, Derin Orhon

    BACKGROUND: This study investigated the anatomy of organic carbon (as chemical oxygen demand, COD) removal from sewage through chemically assisted settling, by means of particle size distribution (PSD) analysis: it showed which size fractions were affected, aside from the particulate COD. The experiments were conducted on the effluent of the existing preliminary treatment plant before deep‐sea discharge into the Bosphorus. FeCl3, alum and polyaluminum chloride (PAC) were used as coagulants at different doses. The performance of the coagulants on the effluent COD was interpreted with PSD.RESULTS: PAC at 25 mg L−1, selected as the optimum coagulant, reduced COD below soluble COD level, to around 145 mg L−1, with an overall efficiency of more than 70%. Although chemical settling was most effective on particulate COD at >450 nm, it also provided a COD removal of 28% in 220–450 nm of the colloidal range and 40% in 13–220 nm of the range, representing soluble hydrolysable COD. The lowest removal rate was observed in the soluble range, consisting of readily biodegradable (only 5%) and a part of the inert COD (<2 nm) identified as 12% – twice as high as ordinary domestic wastewaters, with only 1%.CONCLUSION: PSD and COD fractionation analyses were instrumental in depicting the potential of chemically enhanced settling to reduce COD in the soluble range, identifying the distribution of remaining COD fractions in different size intervals. The results also suggested a novel treatment process with additional membrane filtration, namely membrane chemical reactor, (MCR), reflecting a potential for replacing the conventional activated sludge process. © 2022 Society of Chemical Industry (SCI).


  • Particle size distribution of chemical oxygen demand in industrial effluents: impact on effective filtration size and modelling of membrane bioreactors

    by Serdar Doğruel, Derin Orhon

    This study reviews particle size distribution (PSD) analysis for industrial effluents. Evaluation of available experimental data indicated that the approach started with arbitrary selection of size distribution. Following a pioneering study on pulp and paper effluent, sequential filtration and ultrafiltration has established itself as a prescribed methodology complementing respirometric assessment of chemical oxygen demand (COD) fractionation based on biodegradation characteristics. Results indicated that most industrial effluents exhibited a COD distribution where soluble fractions accounted for the majority of the total COD, with significant implications for the understanding of membrane bioreactor (MBR) systems. Observations on the accumulation of soluble COD in the reactor to levels much higher than the permeate COD paved the way to define an experimental PSD methodology for assessing the effective filtration size for the membrane module. This novel parameter considered in the light of reported PSD analyses showed that a portion of what was conventionally considered soluble COD would be retained by the size barrier of the membrane and recycled back to the reactor. Thus, MBR systems require a new mathematical model structure that would include a modified COD fractionation, account for the retained COD fractions as additional model components and utilize related mass balance relationships in order to yield an accurate mechanistic description of microbial reactions taking place in the system. © 2021 Society of Chemical Industry (SCI).


  • Particle size distribution as a major characteristic of domestic wastewater: implications for the modeling and design of membrane bioreactors

    by Serdar Doğruel, Derin Orhon

    This study reviews the evolution of the concept and the methodology of particle size distribution (PSD) analysis for sewage. Evaluation of experimental data indicated that the analytical approach started with an empirical identification of soluble, colloidal and supra‐colloidal organic matter. Then, it evolved into a sequential filtration and ultrafiltration methodology, yielding results useful enough to be an integral complement of respirometric chemical oxygen demand (COD) fractionation based on biodegradation characteristics. Default values could be defined for the distribution of COD fractions in terms of both size and biodegradation characteristics, which practically showed similar profiles, suggesting that PSD of COD could be directly used for model evaluation and design of activated sludge configurations. Size distribution of COD in sewage should be regarded as a prerequisite for activated sludge systems with a membrane module, mainly to assess the fate of COD fractions that would be entrapped and recycled back to the reactor by membrane filtration. © 2020 Society of Chemical Industry


  • Effect of ultrasonic and microwave disintegration on physico-chemical and biodegradation characteristics of waste-activated sludge

    by Serdar Doğruel, Aslı Sedem Özgen

    The purpose of this study was to investigate the effect of ultrasonic and microwave disintegration on physico-chemical and biodegradability properties of waste-activated sludge (WAS) from a municipal wastewater treatment plant. Another aim was to carry out particle size distribution (PSD) analysis as an integral component of sludge characterization to highlight the transformation mechanisms involved in pretreatment processes and better understand the biodegradation patterns of sonicated and irradiated WAS liquids examined by means of respirometric measurements. Various combinations of sonication and microwave irradiation parameters were applied to optimize operating conditions. The optimum ultrasonic density was determined as 1.5 W/mL, and energy dosages lower than 30,000 kJ/kg TS resulted in a fairly linear increase in the soluble chemical oxygen demand (SCOD) release. An irradiation time of 10 min and a temperature of 175°C were selected as the optimum microwave pretreatment conditions for sludge liquefaction. The most apparent impact of ultrasonication on the PSD of COD was the shifting of the peak at the particulate fraction (>1600 nm) toward the lowest size range (<2 nm). Microwave heating at the selected experimental conditions and ultrasonic pretreatment at 30,000 kJ/kg TS exhibited comparable size distribution and biodegradation characteristics to those of domestic sewage.


  • Open Access

    Biodegradation characteristics of high strength municipal wastewater supported by particle size distribution

    by Serdar Dogruel

    The objective of this study was to evaluate the biodegradability related chemical oxygen demand (COD) fractionation of selected streams from a municipal wastewater treatment plant (MWWTP). The MWWTP under investigation consisted of an activated sludge process which was fed with domestic sewage and pretreated tannery effluents. Another aim was to use particle size distribution (PSD) analysis as a supportive tool for interpreting the effect of primary settling and biological treatment processes on the partitioning of COD fractions over different size categories. The results of conventional characterization and respirometric analyses revealed the strong character of the primary settling tank influent. The high level of soluble inert COD underlined the necessity of an additional treatment step, since the application of biological treatment alone was not adequate to meet the discharge standards. Primary settling removed 35% of the particulate COD, which corresponded to 70% of the initial total COD content, and exhibited only marginal COD removal (2%) in the soluble and colloidal size ranges. Biological treatment almost completely eliminated the particulate COD portion, translating into 60% contribution within 77% overall COD removal; where the COD decrease in the colloidal range amounted to a reduction efficiency of 12% on an overall basis. PSD-based COD fractionation proved to be a useful tool for evaluating the effect of primary settling and applied biological treatment process. PSD also complemented the results of respirometric analyses and provided supporting information for the interpretation of biodegradation characteristics by yielding the size distribution of major COD fractions.


  • Potential of ultrafiltration for organic matter removal in the polymer industry effluent based on particle size distribution analysis

    by Serdar Doğruel, Emine Ubay Çokgör, Orhan Ince, Seval Sözen, Derin Orhon

    The purpose of the study was the experimental evaluation of ultrafiltration as a potential innovative technology for the removal of organic matter of around 15,000 mg chemical oxygen demand (COD) per liter in the polymer industry wastewater. Particle size distribution (PSD) analysis served as the major experimental instrument along with conventional chemical settling. Biodegradation characteristics of the remaining COD after ultrafiltration were determined by model interpretation of the corresponding oxygen uptake rate (OUR) profile. The study first involved a detailed characterization of the polymer wastewater including PSD analysis of the COD content. Chemical treatability was investigated using lime alone and with ferric chloride as coagulants followed with a PSD assessment of the chemically settled effluent. Modeling of the OUR profile generated by the ultrafiltration effluent defined related biodegradation kinetics and provided information on the overall COD removal potential. PSD analysis indicated that more than 70 % of the total COD accumulated in the 220- to 450-nm size range. It indicated that ultrafiltration was potentially capable of removing more than 90 % of the COD with an effluent lower than 1,500 mg COD/L. Chemical settling with 750 mg/L of FeCl3 dosing at a pH of 7.0 provided a similar performance. The ultrafiltration effluent included mainly hydrolysable COD and proved to be biodegradable, with the process kinetics compatible with domestic sewage. PSD evaluation proved to be a valuable scientific instrument for underlining the merit of ultrafiltration as the appropriate innovative technology for polymer wastewater, removing the major portion of the COD in a way that is suitable for recovery and reuse and producing a totally biodegradable effluent.