Michael J. Weaver
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michael J. Weaver has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Edward Kenneth Rodriguez
Carl J. Shapiro Department of Orthopaedic Surgery, Musculoskeletal Translational Innovation Initiative, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, USA
2 shared publications George W. Chaus
Frontrange Orthoaedics and Spine, Longmont, USA
2 shared publicationsMark S. Vrahas
Cedars-Sinai Medical Center, Los Angeles, USA
2 shared publications- Mark S. Vrahas
Brigham and Women’s Hospital and Massachusetts General Hospital
2 shared publications Mitchel B. Harris
Harvard Medical School, Department of Orthopedic Surgery, Brigham and Women's Hospital, Boston, MA; and
2 shared publications- Mitchel Byron Harris
Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts
2 shared publications
Latest Publications
- 24 May 2025
- Published by Springer Nature
- p. 355-365
Pelvic Ring Fractures
- Open Access
- 13 August 2022
- Published by MDPI AG in Geriatrics
- Vol. 7 (4) , 84
Comparative Outcomes and Surgical Timing for Operative Fragility Hip Fracture Patients during the COVID-19 Pandemic: A Retrospective Cohort Study
The COVID-19 pandemic had wide-reaching effects on healthcare delivery, including care for hip fractures, a common injury among older adults. This study characterized factors related to surgical timing and outcomes, length-of-stay, and discharge disposition among patients treated for operative hip fractures during the first wave of the COVID-19 pandemic, compared to historical controls. A retrospective, observational cohort study was conducted from 16 March–20 May 2020 with a consecutive series of 64 operative fragility hip fracture patients at three tertiary academic medical centers. Historical controls were matched based on sex, surgical procedure, age, and comorbidities. Primary outcomes included 30-day mortality and time-to-surgery. Secondary outcomes included 30-day postoperative complications, length-of-stay, discharge disposition, and time to obtain a COVID-19 test result. There was no difference in 30-day mortality, complication rates, length-of-stay, anesthesia type, or time-to-surgery, despite a mean time to obtain a final preoperative COVID-19 test result of 17.6 h in the study group. Notably, 23.8% of patients were discharged to home during the COVID-19 pandemic, compared to 4.8% among controls (p = 0.003). On average, patients received surgical care within 48 h of arrival during the COVID-19 pandemic. More patients were discharged to home rather than a facility with no change in complications, suggesting an opportunity for increased discharge to home.
- 13 August 2022
- Published by MDPI AG in Geriatrics
- Vol. 7 (4) , 84
Open AccessComparative Outcomes and Surgical Timing for Operative Fragility Hip Fracture Patients during the COVID-19 Pandemic: A Retrospective Cohort Study
The COVID-19 pandemic had wide-reaching effects on healthcare delivery, including care for hip fractures, a common injury among older adults. This study characterized factors related to surgical timing and outcomes, length-of-stay, and discharge disposition among patients treated for operative hip fractures during the first wave of the COVID-19 pandemic, compared to historical controls. A retrospective, observational cohort study was conducted from 16 March–20 May 2020 with a consecutive series of 64 operative fragility hip fracture patients at three tertiary academic medical centers. Historical controls were matched based on sex, surgical procedure, age, and comorbidities. Primary outcomes included 30-day mortality and time-to-surgery. Secondary outcomes included 30-day postoperative complications, length-of-stay, discharge disposition, and time to obtain a COVID-19 test result. There was no difference in 30-day mortality, complication rates, length-of-stay, anesthesia type, or time-to-surgery, despite a mean time to obtain a final preoperative COVID-19 test result of 17.6 h in the study group. Notably, 23.8% of patients were discharged to home during the COVID-19 pandemic, compared to 4.8% among controls (p = 0.003). On average, patients received surgical care within 48 h of arrival during the COVID-19 pandemic. More patients were discharged to home rather than a facility with no change in complications, suggesting an opportunity for increased discharge to home.
- Open Access
- 4 June 2021
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 22 (1) , 1-9
The effect of surgeon-controlled variables on construct stiffness in lateral locked plating of distal femoral fractures
Background: Nonunion following treatment of supracondylar femur fractures with lateral locked plates (LLP) has been reported to be as high as 21 %. Implant related and surgeon-controlled variables have been postulated to contribute to nonunion by modulating fracture-fixation construct stiffness. The purpose of this study is to evaluate the effect of surgeon-controlled factors on stiffness when treating supracondylar femur fractures with LLPs: Does plate length affect construct stiffness given the same plate material, fracture working length and type of screws? Does screw type (bicortical locking versus bicortical nonlocking or unicortical locking) and number of screws affect construct stiffness given the same material, fracture working length, and plate length? Does fracture working length affect construct stiffness given the same plate material, length and type of screws? Does plate material (titanium versus stainless steel) affect construct stiffness given the same fracture working length, plate length, type and number of screws? Methods: Mechanical study of simulated supracondylar femur fractures treated with LLPs of varying lengths, screw types, fractureworking lenghts, and plate/screw material. Overall construct stiffness was evaluated using an Instron hydraulic testing apparatus. Results: Stiffness was 15 % higher comparing 13-hole to the 5-hole plates (995 N/mm849N vs. /mm, p = 0.003). The use of bicortical nonlocking screws decreased overall construct stiffness by 18 % compared to bicortical locking screws (808 N/mm vs. 995 N/mm, p = 0.0001). The type of screw (unicortical locking vs. bicortical locking) and the number of screws in the diaphysis (3 vs. 10) did not appear to significantly influence construct stiffness (p = 0.76, p = 0.24). Similarly, fracture working length (5.4 cm vs. 9.4 cm, p = 0.24), and implant type (titanium vs. stainless steel, p = 0.12) did also not appear to effect stiffness. Discussion: Using shorter plates and using bicortical nonlocking screws (vs. bicortical locking screws) reduced overall construct stiffness. Using more screws, using unicortical locking screws, increasing fracture working length and varying plate material (titanium vs. stainless steel) does not appear to significantly alter construct stiffness. Surgeons can adjust plate length and screw types to affect overall fracture-fixation construct stiffness; however, the optimal stiffness to promote healing remains unknown.
- 4 June 2021
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 22 (1) , 1-9
Open AccessThe effect of surgeon-controlled variables on construct stiffness in lateral locked plating of distal femoral fractures
Background: Nonunion following treatment of supracondylar femur fractures with lateral locked plates (LLP) has been reported to be as high as 21 %. Implant related and surgeon-controlled variables have been postulated to contribute to nonunion by modulating fracture-fixation construct stiffness. The purpose of this study is to evaluate the effect of surgeon-controlled factors on stiffness when treating supracondylar femur fractures with LLPs: Does plate length affect construct stiffness given the same plate material, fracture working length and type of screws? Does screw type (bicortical locking versus bicortical nonlocking or unicortical locking) and number of screws affect construct stiffness given the same material, fracture working length, and plate length? Does fracture working length affect construct stiffness given the same plate material, length and type of screws? Does plate material (titanium versus stainless steel) affect construct stiffness given the same fracture working length, plate length, type and number of screws? Methods: Mechanical study of simulated supracondylar femur fractures treated with LLPs of varying lengths, screw types, fractureworking lenghts, and plate/screw material. Overall construct stiffness was evaluated using an Instron hydraulic testing apparatus. Results: Stiffness was 15 % higher comparing 13-hole to the 5-hole plates (995 N/mm849N vs. /mm, p = 0.003). The use of bicortical nonlocking screws decreased overall construct stiffness by 18 % compared to bicortical locking screws (808 N/mm vs. 995 N/mm, p = 0.0001). The type of screw (unicortical locking vs. bicortical locking) and the number of screws in the diaphysis (3 vs. 10) did not appear to significantly influence construct stiffness (p = 0.76, p = 0.24). Similarly, fracture working length (5.4 cm vs. 9.4 cm, p = 0.24), and implant type (titanium vs. stainless steel, p = 0.12) did also not appear to effect stiffness. Discussion: Using shorter plates and using bicortical nonlocking screws (vs. bicortical locking screws) reduced overall construct stiffness. Using more screws, using unicortical locking screws, increasing fracture working length and varying plate material (titanium vs. stainless steel) does not appear to significantly alter construct stiffness. Surgeons can adjust plate length and screw types to affect overall fracture-fixation construct stiffness; however, the optimal stiffness to promote healing remains unknown.
- Open Access
- 1 August 2020
- Published by Elsevier in Trauma & Case Reports
- Vol. 28, 100323
Orthopedic telemedicine encounter during the COVID-19 pandemic: A cautionary tale
- 1 August 2020
- Published by Elsevier in Trauma & Case Reports
- Vol. 28, 100323
Open AccessOrthopedic telemedicine encounter during the COVID-19 pandemic: A cautionary tale
- 3 May 2018
- Published by Springer Nature in Current Radiology Reports
- Vol. 6 (7) , 1-13
Hip Fractures: A Practical Approach to Diagnosis and Treatment
- 3 May 2018
- Published by Springer Nature in Current Radiology Reports
- Vol. 6 (7) , 1-13
Hip Fractures: A Practical Approach to Diagnosis and Treatment
- 19 December 2017
- Published by Springer Nature
- p. 111-123
Total Hip Arthroplasty and the Treatment of Hip Osteoarthritis
- 19 December 2017
- Published by Springer Nature
- p. 111-123
Total Hip Arthroplasty and the Treatment of Hip Osteoarthritis
- 1 December 2015
- Published by Elsevier in Operative Techniques in Orthopaedics
- Vol. 25 (4) , 262-269
Anterior Subcutaneous Internal Fixation of the Pelvis: Placement of the INFIX
- 1 December 2015
- Published by Elsevier in Operative Techniques in Orthopaedics
- Vol. 25 (4) , 262-269
Anterior Subcutaneous Internal Fixation of the Pelvis: Placement of the INFIX
- 1 November 2015
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 29 (11) , 494-499
Does Health Reform Change Femoral Neck Fracture Care? A Natural Experiment in the State of Massachusetts
To determine whether hospital processes and hospital quality associated with the care of femoral neck fractures were significantly altered by the implementation of healthcare reform in Massachusetts.Pre-post retrospective study.Massachusetts Statewide Inpatient Dataset (SID).Patients treated for femoral neck fracture (n = 23,485) in the periods prehealth (2003-06) and posthealth reform (2008-10).Differences in hospital processes for fracture care and quality measures were assessed for the periods before and after health reform.Differences in hospital processes for fracture care (type of surgical intervention, length of stay, and discharge disposition) and quality metrics [mortality, complications, re-operation, and failure to rescue (FTR)] in the periods before and after health reform were assessed using regression techniques to adjust for differences in case mix and the type of surgical intervention.There were no significant differences in the type of surgical intervention performed prereform and postreform (P = 0.27). After adjustment for case mix and surgical intervention, length of stay was significantly reduced {regression coefficient -0.07 [95% confidence interval (CI), -0.09 to -0.06]} as were the odds of FTR [odds ratio 0.73 (95% CI, 0.59-0.92)]. Discharges to skilled nursing facilities significantly increased in the postreform period [relative risk ratio 1.15 (95% CI, 1.03-1.30)]. Findings associated with FTR were driven by changes in the detection of surveillance sensitive complications.Health reform in Massachusetts led to no clinically meaningful differences in hospital processes for femoral neck fracture care. Although some differences in quality measures were noted, these cannot necessarily be attributed to health care reform.Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 November 2015
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 29 (11) , 494-499
Does Health Reform Change Femoral Neck Fracture Care? A Natural Experiment in the State of Massachusetts
To determine whether hospital processes and hospital quality associated with the care of femoral neck fractures were significantly altered by the implementation of healthcare reform in Massachusetts.Pre-post retrospective study.Massachusetts Statewide Inpatient Dataset (SID).Patients treated for femoral neck fracture (n = 23,485) in the periods prehealth (2003-06) and posthealth reform (2008-10).Differences in hospital processes for fracture care and quality measures were assessed for the periods before and after health reform.Differences in hospital processes for fracture care (type of surgical intervention, length of stay, and discharge disposition) and quality metrics [mortality, complications, re-operation, and failure to rescue (FTR)] in the periods before and after health reform were assessed using regression techniques to adjust for differences in case mix and the type of surgical intervention.There were no significant differences in the type of surgical intervention performed prereform and postreform (P = 0.27). After adjustment for case mix and surgical intervention, length of stay was significantly reduced {regression coefficient -0.07 [95% confidence interval (CI), -0.09 to -0.06]} as were the odds of FTR [odds ratio 0.73 (95% CI, 0.59-0.92)]. Discharges to skilled nursing facilities significantly increased in the postreform period [relative risk ratio 1.15 (95% CI, 1.03-1.30)]. Findings associated with FTR were driven by changes in the detection of surveillance sensitive complications.Health reform in Massachusetts led to no clinically meaningful differences in hospital processes for femoral neck fracture care. Although some differences in quality measures were noted, these cannot necessarily be attributed to health care reform.Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 12 August 2015
- Published by Springer Nature
- p. 1210-1216
Pelvis Fractures