Ali Reza Zarei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ali Reza Zarei has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Kobra Mardi
Faculty of Chemistry and Chemical Engineering, Malek Ashtar University of Technology, Tehran, Iran
8 shared publicationsMaryam Nedaei
Faculty of Chemical Engineering, School of Engineering, University of Tehran, Tehran, Iran
3 shared publications- Sohrab Ali Ghorbanian
School of Chemical Engineering, College of Engineering, University of Tehran, Tehran, Iran
3 shared publications Ali Moloudi
Faculty of Chemistry and Chemical Engineering, Malek Ashtar University of Technology, P.O. Box 15875-1774 Tehran, I.R. IRAN
2 shared publicationsFarideh Barghak
Malek Ashtar University of Technology Tehran
2 shared publications- Hadi Rezaei-Vahidian
Department of Chemistry, Space Transportation Research Institute, Iranian Space Research Center, Tehran, Iran
2 shared publications
Latest Publications
- 19 November 2025
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 237 (3) , 148
Simultaneous Monitoring of Military-Origin Pollutants in Environmental Water Samples Using UV–Vis Spectrophotometry Coupled with Multivariate Calibration Models
- 19 November 2025
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 237 (3) , 148
Simultaneous Monitoring of Military-Origin Pollutants in Environmental Water Samples Using UV–Vis Spectrophotometry Coupled with Multivariate Calibration Models
- 7 October 2022
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 77 (10) , 1247-1255
Development of Derivative Ratio Spectrophotometric Method for Simultaneous Determination of Copper β-resorcylate, Lead β-resorcylate, and Lead Oxide in Double base Propellants
A new and validated method was described for the resolution of a ternary mixture of copper β‑resorcylate (CuR2), lead β-resorcylate (PbR2), and lead oxide in double base (DB) solid propellants without prior separation steps in accordance with military guidelines. Two sets of reaction and determination conditions were developed. The first set was based on reaction of Cu(II) and Pb(II) with 4-(2-pyridylazo)resorcinol reagent in alkaline media and using derivative ratio spectrophotometry for the simultaneous determination of Cu(II) and Pb(II) by measuring the peak intensities at 539 and 543 nm, respectively. In the second set, with hydrolysis of CuR2 and PbR2 in acetic acid medium, the released resorcylic acid was determined via complex formation of resorcylic acid with Fe(III) and absorbance measurement at 526 nm. The amounts of CuR2 and total lead can be determined by derivative ratio spectrophotometry. So, according to the obtained data for resorcylic acid, CuR2, and total lead by derivative ratio spectrophotometry, the amounts of PbR2 and PbO were determined by applying stoichiometric equations. The proposed method was successfully applied for the determination of CuR2, PbR2, and PbO in DB propellants. The results of the method were statistically compared based on t- and F-tests with those obtained by inductively coupled plasma atomic emission spectrometry. The results showed that the proposed method offers an accurate and reliable approach for the determination of these compounds in DB propellants and can be suggested as a routine method in military quality control laboratories.
- 7 October 2022
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 77 (10) , 1247-1255
Development of Derivative Ratio Spectrophotometric Method for Simultaneous Determination of Copper β-resorcylate, Lead β-resorcylate, and Lead Oxide in Double base Propellants
A new and validated method was described for the resolution of a ternary mixture of copper β‑resorcylate (CuR2), lead β-resorcylate (PbR2), and lead oxide in double base (DB) solid propellants without prior separation steps in accordance with military guidelines. Two sets of reaction and determination conditions were developed. The first set was based on reaction of Cu(II) and Pb(II) with 4-(2-pyridylazo)resorcinol reagent in alkaline media and using derivative ratio spectrophotometry for the simultaneous determination of Cu(II) and Pb(II) by measuring the peak intensities at 539 and 543 nm, respectively. In the second set, with hydrolysis of CuR2 and PbR2 in acetic acid medium, the released resorcylic acid was determined via complex formation of resorcylic acid with Fe(III) and absorbance measurement at 526 nm. The amounts of CuR2 and total lead can be determined by derivative ratio spectrophotometry. So, according to the obtained data for resorcylic acid, CuR2, and total lead by derivative ratio spectrophotometry, the amounts of PbR2 and PbO were determined by applying stoichiometric equations. The proposed method was successfully applied for the determination of CuR2, PbR2, and PbO in DB propellants. The results of the method were statistically compared based on t- and F-tests with those obtained by inductively coupled plasma atomic emission spectrometry. The results showed that the proposed method offers an accurate and reliable approach for the determination of these compounds in DB propellants and can be suggested as a routine method in military quality control laboratories.
- 6 August 2022
- Published by Springer Nature in Analytical Sciences
- Vol. 38 (11) , 1417-1424
A simple and safe approach for simultaneous spectrophotometric determination of nitroglycerin and nitrocellulose in double base solid propellants
An accurate, simple and safe method was developed for simultaneous determination of nitroglycerine (NG) and nitrocellulose (NC) in double base solid propellants (DB propellants). The proposed method is based on alkaline hydrolysis of NG and NC, and followed by colored reaction of released nitrite ion with p-nitroaniline in the presence of diphenylamine in acidic media and produce azo dye. The absorbance of the azo dye was measured at 534 nm. Two sets of reaction conditions were developed. In the first set, at room temperature, only NG was hydrolyzed and calibration curve obtained. In the second set, at 60 ℃, NG and NC were hydrolyzed simultaneously. Based on obtained amount for the NG at room temperature, and total amount of NG and NC at 60 ℃, the amount of NC was determined by using stoichiometric equations. The calibration curve was linear over the concentration ranges of 0.2–5.0, 0.5–10 μg mL−1 for NG and NC, respectively. The proposed method was successfully applied for the determination of NG and NC in DB propellants with good recoveries ranged from 99 to 101%, and RSD less than 2.0%. The method statistically compared based on t- and F-tests with those obtained in according to military standard method (MIL-STD-286). The results showed that the proposed method offers an accuracy and reliable approach for the determination of these compounds in DB propellants, and can be suggested as a routine method in military quality control laboratories. Graphical abstract
- 6 August 2022
- Published by Springer Nature in Analytical Sciences
- Vol. 38 (11) , 1417-1424
A simple and safe approach for simultaneous spectrophotometric determination of nitroglycerin and nitrocellulose in double base solid propellants
An accurate, simple and safe method was developed for simultaneous determination of nitroglycerine (NG) and nitrocellulose (NC) in double base solid propellants (DB propellants). The proposed method is based on alkaline hydrolysis of NG and NC, and followed by colored reaction of released nitrite ion with p-nitroaniline in the presence of diphenylamine in acidic media and produce azo dye. The absorbance of the azo dye was measured at 534 nm. Two sets of reaction conditions were developed. In the first set, at room temperature, only NG was hydrolyzed and calibration curve obtained. In the second set, at 60 ℃, NG and NC were hydrolyzed simultaneously. Based on obtained amount for the NG at room temperature, and total amount of NG and NC at 60 ℃, the amount of NC was determined by using stoichiometric equations. The calibration curve was linear over the concentration ranges of 0.2–5.0, 0.5–10 μg mL−1 for NG and NC, respectively. The proposed method was successfully applied for the determination of NG and NC in DB propellants with good recoveries ranged from 99 to 101%, and RSD less than 2.0%. The method statistically compared based on t- and F-tests with those obtained in according to military standard method (MIL-STD-286). The results showed that the proposed method offers an accuracy and reliable approach for the determination of these compounds in DB propellants, and can be suggested as a routine method in military quality control laboratories. Graphical abstract
- 25 February 2022
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 19 (8) , 1-10
Development of spectrophotometric method for simultaneous determination of copper β-resorcylate, lead β-resorcylate and lead oxide in double base solid propellants using mean centering of ratio spectra technique
- 25 February 2022
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 19 (8) , 1-10
Development of spectrophotometric method for simultaneous determination of copper β-resorcylate, lead β-resorcylate and lead oxide in double base solid propellants using mean centering of ratio spectra technique
- 14 November 2021
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 76 (11) , 1296-1304
Green Sample Preparation Based on Directly Suspended Droplet Microextraction using Deep Eutectic Solvent for Ultra-Trace Quantification of Nitroaromatic Explosives by High Performance Liquid Chromatography
In the present study, a simple and efficient directly suspended-solidified floating organic droplet microextraction using deep eutectic solvent in combination with high performance liquid chromatography has been proposed for the extraction and ultra-trace quantification of nitroaromatic explosives. The predominant experimental factors such as type and amount of deep eutectic solvent, extraction time, salt concentration and temperature that affect the extraction efficiency of nitroaromatic explosives were considered and optimized. By performing the process in optimal conditions, the calibration curves were linear in the range of 0.6–200 µg/L for 2,4,6-trinitrotolouene (TNT), 0.5–200 µg/L for 2,4-dinitrotolouene (2,4-DNT) and 0.5–200 µg/L for 2,6-dinitrotolouene (2,6-DNT). The limits of detection were 0.19, 0.16 and 0.14 µg/L for TNT, 2,4-DNT and 2.6-DNT, respectively. The relative standard deviations were between 4.8–6.4% (n = 6). The proposed method was successfully applied to the analysis of soil and water samples. At the different spiking levels recovery values ranged between 89 to 102% for soil and water samples, which indicates the negligible effect of the matrix on the extraction process.
- 14 November 2021
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 76 (11) , 1296-1304
Green Sample Preparation Based on Directly Suspended Droplet Microextraction using Deep Eutectic Solvent for Ultra-Trace Quantification of Nitroaromatic Explosives by High Performance Liquid Chromatography
In the present study, a simple and efficient directly suspended-solidified floating organic droplet microextraction using deep eutectic solvent in combination with high performance liquid chromatography has been proposed for the extraction and ultra-trace quantification of nitroaromatic explosives. The predominant experimental factors such as type and amount of deep eutectic solvent, extraction time, salt concentration and temperature that affect the extraction efficiency of nitroaromatic explosives were considered and optimized. By performing the process in optimal conditions, the calibration curves were linear in the range of 0.6–200 µg/L for 2,4,6-trinitrotolouene (TNT), 0.5–200 µg/L for 2,4-dinitrotolouene (2,4-DNT) and 0.5–200 µg/L for 2,6-dinitrotolouene (2,6-DNT). The limits of detection were 0.19, 0.16 and 0.14 µg/L for TNT, 2,4-DNT and 2.6-DNT, respectively. The relative standard deviations were between 4.8–6.4% (n = 6). The proposed method was successfully applied to the analysis of soil and water samples. At the different spiking levels recovery values ranged between 89 to 102% for soil and water samples, which indicates the negligible effect of the matrix on the extraction process.
- 17 October 2021
- Published by Taylor & Francis in Journal of Energetic Materials
- Vol. 41 (3) , 365-377
A simple and selective approach for determination of titanium dioxide in double base solid propellants: methodology for method validation
In this work, we developed and validated a simple and selective method for the determination of titanium dioxide in double base solid (DB propellants). The method is based on complex formation of Ti(IV) with hydrogen peroxide in acidic media and monitoring absorbance of colored product by spectrophotometric technique at 407 nm. Under optimal conditions, at λmax = 407 nm, the linear range of determination of Ti(IV) was 5.0–100 µg mL−1 with detection limits of 3.0 µg mL−1. The validity of the method was evaluated by means of the data statistical analysis. For this purpose, the method was applied to the determination of titanium dioxide (TiO2) in DB propellants and the results were statistically compared with those obtained by the by ICP-AES method using t- and F-tests. There was no significant difference between the mean values and the precisions of the two methods at the 95% confidence level. The results showed that the proposed method offers an accurate and reliable approach for the determination of titanium dioxide in DB propellants, and can be suggested as a routine method in military quality control laboratories.
- 17 October 2021
- Published by Taylor & Francis in Journal of Energetic Materials
- Vol. 41 (3) , 365-377
A simple and selective approach for determination of titanium dioxide in double base solid propellants: methodology for method validation
In this work, we developed and validated a simple and selective method for the determination of titanium dioxide in double base solid (DB propellants). The method is based on complex formation of Ti(IV) with hydrogen peroxide in acidic media and monitoring absorbance of colored product by spectrophotometric technique at 407 nm. Under optimal conditions, at λmax = 407 nm, the linear range of determination of Ti(IV) was 5.0–100 µg mL−1 with detection limits of 3.0 µg mL−1. The validity of the method was evaluated by means of the data statistical analysis. For this purpose, the method was applied to the determination of titanium dioxide (TiO2) in DB propellants and the results were statistically compared with those obtained by the by ICP-AES method using t- and F-tests. There was no significant difference between the mean values and the precisions of the two methods at the 95% confidence level. The results showed that the proposed method offers an accurate and reliable approach for the determination of titanium dioxide in DB propellants, and can be suggested as a routine method in military quality control laboratories.
- Open Access
- 1 January 2021
- Vol. 40 (1) , 57-68
Highly Efficient Destruction of Perchlorate to Nontoxic Chloride Ion (Cl-) from Aqueous Solutions by Bimetallic Fe/Ni Nanoparticles
- 1 January 2021
- Vol. 40 (1) , 57-68
Open AccessHighly Efficient Destruction of Perchlorate to Nontoxic Chloride Ion (Cl-) from Aqueous Solutions by Bimetallic Fe/Ni Nanoparticles
- 6 January 2020
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 39 (4)
Photocatalytic degradation of nitro‐aromatic explosives using visible‐light‐activated WO3: Optimization and catalyst modification
Nitro‐aromatic explosives are hazardous, stable, and carcinogenic pollutants in industrial wastewaters. Photocatalytic degradation is one of the most efficient methods for the treatment of these types of pollutants. In this work, the degradation of p‐nitrophenol (PNP) as a typical nitro‐aromatic pollutant was studied using the synthesized catalyst WO3 under visible light irradiation. The synthesized catalyst was characterized using X‐ray diffraction, field‐emission scanning electron microscopy, and diffuse reflection spectroscopy. The effect of the operational parameters on the process efficiency, such as initial pH, initial concentration of PNP, catalyst dose, reaction temperature, calcination temperature (CT), and light source type, was studied. The effect of different morphologies of WO3 on the process efficiency was also evaluated. The results show that, under the optimum condition (pH = 11.5, catalyst dosage = 1000 μg/ml, and CT = 700°C) at T = 25°C and for initial PNP concentration of 20 μg/ml, the process can degrade and mineralize PNP by about 90% and 40.16%, respectively, after 240 min. Under the obtained optimum condition, mineralization of 2,4,6‐trinitrotoluene as a nitro‐aromatic explosive was evaluated, and 28% mineralization was observed after 240 min. The electrical energy consumption of the process was also assessed, and under the optimum condition, it was calculated as 602.3 and 94.0 kWh/m3 for the metal halide lamp and light‐emitting diode, respectively.
- 6 January 2020
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 39 (4)
Photocatalytic degradation of nitro‐aromatic explosives using visible‐light‐activated WO3: Optimization and catalyst modification
Nitro‐aromatic explosives are hazardous, stable, and carcinogenic pollutants in industrial wastewaters. Photocatalytic degradation is one of the most efficient methods for the treatment of these types of pollutants. In this work, the degradation of p‐nitrophenol (PNP) as a typical nitro‐aromatic pollutant was studied using the synthesized catalyst WO3 under visible light irradiation. The synthesized catalyst was characterized using X‐ray diffraction, field‐emission scanning electron microscopy, and diffuse reflection spectroscopy. The effect of the operational parameters on the process efficiency, such as initial pH, initial concentration of PNP, catalyst dose, reaction temperature, calcination temperature (CT), and light source type, was studied. The effect of different morphologies of WO3 on the process efficiency was also evaluated. The results show that, under the optimum condition (pH = 11.5, catalyst dosage = 1000 μg/ml, and CT = 700°C) at T = 25°C and for initial PNP concentration of 20 μg/ml, the process can degrade and mineralize PNP by about 90% and 40.16%, respectively, after 240 min. Under the obtained optimum condition, mineralization of 2,4,6‐trinitrotoluene as a nitro‐aromatic explosive was evaluated, and 28% mineralization was observed after 240 min. The electrical energy consumption of the process was also assessed, and under the optimum condition, it was calculated as 602.3 and 94.0 kWh/m3 for the metal halide lamp and light‐emitting diode, respectively.
- 1 September 2019
- Published by Elsevier in Journal of Chromatography A
- Vol. 1601, 35-44
Miniaturized matrix solid-phase dispersion based on deep eutectic solvent and carbon nitride associated with high-performance liquid chromatography: A new feasibility for extraction and determination of trace nitrotoluene pollutants in soil samples
- 1 September 2019
- Published by Elsevier in Journal of Chromatography A
- Vol. 1601, 35-44
Miniaturized matrix solid-phase dispersion based on deep eutectic solvent and carbon nitride associated with high-performance liquid chromatography: A new feasibility for extraction and determination of trace nitrotoluene pollutants in soil samples
- 18 June 2018
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 42 (15) , 12520-12529
Development of a new emulsification microextraction method based on solidification of settled organic drop: application of a novel ultra-hydrophobic tailor-made deep eutectic solvent
In this research, a new microextraction method based on the solidification of settled organic drop (SSOD) was developed by coupling a novel tailor-made ultra-hydrophobic deep eutectic solvent (DES) with effervescence assisted emulsification microextraction. The deep eutectic solvent of salol/DL-menthol (1 : 1) was used as an extraction solvent in this study. It has a low melting/freezing point, low viscosity, ultra-hydrophobicity and bio-compatibility. An effervescent tablet was prepared by mixing the DES and effervescence precursors. Generation of CO2 bubbles due to effervescence distributes the DES homogenously into an aqueous sample, which enhances the mass transfer for target analytes to extract into the fine DES droplets. After centrifugation of the cloudy solution at 20 °C, the settled solidified extractant was isolated from the aqueous solution simply by decanting the tube. Predominant experimental variables affecting the extraction efficiency of explosives were evaluated. This method was coupled with high performance liquid chromatography-ultra violet detection for the analysis of nitroaromatic compounds. Under the optimized conditions, the limits of detection achieved were in the range of 0.03–0.05 μg L−1. The enrichment factors were between 576 and 702 and the relative standard deviations were <10%. The analysis of eight nitroaromatic pollutants in water samples gave acceptable recoveries ranging from 89 to 105%.
- 18 June 2018
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 42 (15) , 12520-12529
Development of a new emulsification microextraction method based on solidification of settled organic drop: application of a novel ultra-hydrophobic tailor-made deep eutectic solvent
In this research, a new microextraction method based on the solidification of settled organic drop (SSOD) was developed by coupling a novel tailor-made ultra-hydrophobic deep eutectic solvent (DES) with effervescence assisted emulsification microextraction. The deep eutectic solvent of salol/DL-menthol (1 : 1) was used as an extraction solvent in this study. It has a low melting/freezing point, low viscosity, ultra-hydrophobicity and bio-compatibility. An effervescent tablet was prepared by mixing the DES and effervescence precursors. Generation of CO2 bubbles due to effervescence distributes the DES homogenously into an aqueous sample, which enhances the mass transfer for target analytes to extract into the fine DES droplets. After centrifugation of the cloudy solution at 20 °C, the settled solidified extractant was isolated from the aqueous solution simply by decanting the tube. Predominant experimental variables affecting the extraction efficiency of explosives were evaluated. This method was coupled with high performance liquid chromatography-ultra violet detection for the analysis of nitroaromatic compounds. Under the optimized conditions, the limits of detection achieved were in the range of 0.03–0.05 μg L−1. The enrichment factors were between 576 and 702 and the relative standard deviations were <10%. The analysis of eight nitroaromatic pollutants in water samples gave acceptable recoveries ranging from 89 to 105%.