M. Tanemura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
M. Tanemura has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- F. Okuyama
Department of Environmental Technology, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555, Japan
5 shared publications D. Nicolaescu
Nanoelectronics Research Institute, AIST, Umezono 1-1-1, Tsukuba, Ibaraki 305-8568, Japan
4 shared publications- Valeriu Filip
University of Bucharest
4 shared publications B. N. Dev
Institute of Physics, Sachivalaya Marg, Bhubaneswar 751005, India
1 shared publication- Bibhudutta Rout
Department of Physics University of North Texas Denton Texas USA
1 shared publication H. Sugie
Department of Electrical and Computer Engineering, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya 466-8555, Japan
1 shared publication
Latest Publications
- 1 May 2004
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Vol. 22 (3) , 1234-1239
Analytical model for electron field emission from capped carbon nanotubes
This article presents a model of electron field emission from quantum states arising from the tight confinement of quasi-free electrons on a nanotube hemispherical cap. The model outlines the possibility of inhomogeneous electron field emission for very thin carbon nanotubes at high emission levels and the appearance of peculiar ring-shaped field emission images. The conclusions qualitatively agree with existing experimental evidence, therefore supporting the hypothesis that part of the electrons on the cap of the emitter may behave as quasi-free in a high emission level/high-temperature regime.
- 1 May 2004
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Vol. 22 (3) , 1234-1239
Analytical model for electron field emission from capped carbon nanotubes
This article presents a model of electron field emission from quantum states arising from the tight confinement of quasi-free electrons on a nanotube hemispherical cap. The model outlines the possibility of inhomogeneous electron field emission for very thin carbon nanotubes at high emission levels and the appearance of peculiar ring-shaped field emission images. The conclusions qualitatively agree with existing experimental evidence, therefore supporting the hypothesis that part of the electrons on the cap of the emitter may behave as quasi-free in a high emission level/high-temperature regime.
- 1 July 2003
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Vol. 21 (4) , 1692-1699
Sequential tunneling model of field emission through dielectric deposits on nanotips
A model of sequential (incoherent) tunneling for the electron field emission was built up in order to explain some peculiarities of the electronic emission from relatively thick dielectric layers covering nanometer-range tips, particularly carbon nanotubes. The emission current as a function of applied voltage, dielectric layer thickness, polarizability, and temperature was computed. Various experimentally detected trends were thereby modeled, leading to the conclusion that incoherent tunneling might be a competitive mechanism for electron field emission from dielectric layers on the tips of nanometer-sized cathodes.
- 1 July 2003
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Vol. 21 (4) , 1692-1699
Sequential tunneling model of field emission through dielectric deposits on nanotips
A model of sequential (incoherent) tunneling for the electron field emission was built up in order to explain some peculiarities of the electronic emission from relatively thick dielectric layers covering nanometer-range tips, particularly carbon nanotubes. The emission current as a function of applied voltage, dielectric layer thickness, polarizability, and temperature was computed. Various experimentally detected trends were thereby modeled, leading to the conclusion that incoherent tunneling might be a competitive mechanism for electron field emission from dielectric layers on the tips of nanometer-sized cathodes.
- 1 January 2003
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Vol. 21 (1) , 382-390
Influence of the electronic structure on the field electron emission from carbon nanotubes
The classical statistical-tunneling approach for the electron field emission is applied for carbon nanotubes. Detailed computations for differential emission currents reveal very close peak shapes for the armchair and zigzag geometries, thus suggesting there is very little influence of the form of the electronic energy dispersion relations on the bulk field emission currents. For carbon nanotubes of practical width, an approximate semianalytical procedure is developed to compute the differential and total emission currents for virtually any type of dispersion relations. After validation for the armchair and zigzag geometries, this procedure may be further simplified into the frame of a fictitious confined two-dimensional free electron model. Some conclusions are drawn from the comparison of the computed field emission currents (through the simplified procedure) with present experimental data and a fully analytical expression for the total bulk field emission current is obtained for practical use.
- 1 January 2003
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Vol. 21 (1) , 382-390
Influence of the electronic structure on the field electron emission from carbon nanotubes
The classical statistical-tunneling approach for the electron field emission is applied for carbon nanotubes. Detailed computations for differential emission currents reveal very close peak shapes for the armchair and zigzag geometries, thus suggesting there is very little influence of the form of the electronic energy dispersion relations on the bulk field emission currents. For carbon nanotubes of practical width, an approximate semianalytical procedure is developed to compute the differential and total emission currents for virtually any type of dispersion relations. After validation for the armchair and zigzag geometries, this procedure may be further simplified into the frame of a fictitious confined two-dimensional free electron model. Some conclusions are drawn from the comparison of the computed field emission currents (through the simplified procedure) with present experimental data and a fully analytical expression for the total bulk field emission current is obtained for practical use.
- 1 January 2002
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Vol. 20 (1) , 122-127
Field electron emission from carbon nanotubes grown by plasma-enhanced chemical vapor deposition
Densely distributed, aligned carbon nanotubes were grown on Co-covered W wires by dc-plasma-enhanced chemical vapor deposition with a mixture of acetylene and ammonia as precursors. Each nanotube was capped with a Co carbide particle. The diameter of the nanotubes ranged from 20 to 130 nm, and their average length was about 5 μm. Their field emission characteristics, measured in a modified ultra-high vacuum scanning electron microscope, were analyzed by a statistical field emission model developed for aligned carbon nanotube film cathodes. An indirect method was thus established to obtain the average electrical parameters of the film using only a limited amount of experimental data.
- 1 January 2002
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Vol. 20 (1) , 122-127
Field electron emission from carbon nanotubes grown by plasma-enhanced chemical vapor deposition
Densely distributed, aligned carbon nanotubes were grown on Co-covered W wires by dc-plasma-enhanced chemical vapor deposition with a mixture of acetylene and ammonia as precursors. Each nanotube was capped with a Co carbide particle. The diameter of the nanotubes ranged from 20 to 130 nm, and their average length was about 5 μm. Their field emission characteristics, measured in a modified ultra-high vacuum scanning electron microscope, were analyzed by a statistical field emission model developed for aligned carbon nanotube film cathodes. An indirect method was thus established to obtain the average electrical parameters of the film using only a limited amount of experimental data.
- 15 February 2001
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 13 (2) , 83-87
Redistribution of Ni implanted into InP
The redistribution of Ni in InP is studied by annealing samples of InP implanted with 0.9 MeV Ni at 60o angle of ion incidence with respect to target surface normal as a function of dose (8.5×1012−4.5×1015 cm−2). Ni profiles are measured by secondary ion mass spectrometry (SIMS) and implantation induced damage by Rutherford backscattering spectrometry in channeling (RBS/C) condition. The highest dose sample is characterised by remarkable Ni accumulation near the surface (at ∼ ) that has not been observed earlier along with two other distinct accumulation zones at Rnp+ and after annealing at 650 °C for 30 min. Here, Rnp is the normal component of the projected range for oblique angle bombardment.
- 15 February 2001
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 13 (2) , 83-87
Redistribution of Ni implanted into InP
The redistribution of Ni in InP is studied by annealing samples of InP implanted with 0.9 MeV Ni at 60o angle of ion incidence with respect to target surface normal as a function of dose (8.5×1012−4.5×1015 cm−2). Ni profiles are measured by secondary ion mass spectrometry (SIMS) and implantation induced damage by Rutherford backscattering spectrometry in channeling (RBS/C) condition. The highest dose sample is characterised by remarkable Ni accumulation near the surface (at ∼ ) that has not been observed earlier along with two other distinct accumulation zones at Rnp+ and after annealing at 650 °C for 30 min. Here, Rnp is the normal component of the projected range for oblique angle bombardment.