Shabnam Agarwal
Research Subjects
Research Interests
Shabnam Agarwal has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Garry Thomas Allison
Research Office, Curtin University, Perth, Western Australia, Australia
3 shared publications Kevin P. Singer
The Centre for Musculoskeletal Studies, The University of Western Australia, Perth, Western Australia
3 shared publicationsAjay Agarwal
Calcutta Medical Research Institute, Kolkata, India
1 shared publication
Latest Publications
- 1 January 2006
- Published by Taylor & Francis in Disability and Rehabilitation
- Vol. 28 (22) , 1405-1411
Reliability and validity of the Hindi version of the Neck Pain and Disability Scale in cervical radiculopathy patients
Purpose. To assess the reliability and validity of the Neck Pain and Disability Scale (NPAD) translated into Hindi. Method. Following a pilot study to ascertain uncertainties with existing terminology in the NPAD scale, a cervical radiculopathy patient cohort (n = 63) was assessed with the translated NPAD. Reliability was assessed by regression analysis for test-retest and by item-factor and factor-total score correlations. Face validity was compared in a cross-sectional design study with an asymptomatic group (n = 38). Convergent and divergent validity were investigated by correlating the NPAD scores with the Numerical Pain Rating Scale (NPRS) for neck and arm pain, and 10 cm long VAS Activity and VAS Depression scales. Results. ICC values for test-retest NPAD total and factor scores were >0.92 and R2 values >0.912. Pearson product moment correlation of item vs. factor scores varied from 0.17 – 0.91 and for factor vs. total scores 0.72 – 0.91. Differences in NPAD scores between the patient and the asymptomatic group were significant (t = 30.90, p < 0.05). Convergent validity was explained when Factor 2 (minus item 20) was correlated (r = 0.67) with NPRS maximum value scores. Divergent validity was illustrated by low correlation with VAS Activity (r = 0.15) and negative correlation with VAS Depression (r = −0.80) scores. Conclusion. Based on the results of this study, the Hindi version of the NPAD is a reliable and valid instrument for the assessment of pain and disability in cervical radiculopathy patients.
- 1 January 2006
- Published by Taylor & Francis in Disability and Rehabilitation
- Vol. 28 (22) , 1405-1411
Reliability and validity of the Hindi version of the Neck Pain and Disability Scale in cervical radiculopathy patients
Purpose. To assess the reliability and validity of the Neck Pain and Disability Scale (NPAD) translated into Hindi. Method. Following a pilot study to ascertain uncertainties with existing terminology in the NPAD scale, a cervical radiculopathy patient cohort (n = 63) was assessed with the translated NPAD. Reliability was assessed by regression analysis for test-retest and by item-factor and factor-total score correlations. Face validity was compared in a cross-sectional design study with an asymptomatic group (n = 38). Convergent and divergent validity were investigated by correlating the NPAD scores with the Numerical Pain Rating Scale (NPRS) for neck and arm pain, and 10 cm long VAS Activity and VAS Depression scales. Results. ICC values for test-retest NPAD total and factor scores were >0.92 and R2 values >0.912. Pearson product moment correlation of item vs. factor scores varied from 0.17 – 0.91 and for factor vs. total scores 0.72 – 0.91. Differences in NPAD scores between the patient and the asymptomatic group were significant (t = 30.90, p < 0.05). Convergent validity was explained when Factor 2 (minus item 20) was correlated (r = 0.67) with NPRS maximum value scores. Divergent validity was illustrated by low correlation with VAS Activity (r = 0.15) and negative correlation with VAS Depression (r = −0.80) scores. Conclusion. Based on the results of this study, the Hindi version of the NPAD is a reliable and valid instrument for the assessment of pain and disability in cervical radiculopathy patients.
- 1 October 2005
- Published by National University of Health Sciences in Journal of Manipulative and Physiological Therapeutics
- Vol. 28 (8) , 604-609
Validation of the Spin-T Goniometer, a Cervical Range of Motion Device
To test the validity of the Spin-T goniometer for the assessment of cervical range of movement. A linear regression analysis for paired neck movements using first a foam head model and then human subjects was performed to quantify the differences between the measurements obtained from the MotionStar, a movement-tracking device, and the Spin-T. A within-subject repeated measures design using simultaneous data acquisition was completed. The coefficient of determination (R2) for all planes of cervical range of motion for both model and human data sets was higher than 0.99. The regression equations for the model data showed no significant (P > .05) intercept for flexion-extension and lateral rotation. Human data showed statistically significant intercept for flexion-extension (mean, -0.52 degrees) and lateral flexion (mean, 0.81 degrees) at P < .05. This study quantifies the difference between the MotionStar and the Spin-T goniometer and documents the systematic error between the measures. Where the error reached statistical significance, the magnitude of the error was very small (< 1.5 degrees). The results of this study suggest that the Spin-T goniometer may be used as a valid measuring instrument for cervical range of movement.
- 1 October 2005
- Published by National University of Health Sciences in Journal of Manipulative and Physiological Therapeutics
- Vol. 28 (8) , 604-609
Validation of the Spin-T Goniometer, a Cervical Range of Motion Device
To test the validity of the Spin-T goniometer for the assessment of cervical range of movement. A linear regression analysis for paired neck movements using first a foam head model and then human subjects was performed to quantify the differences between the measurements obtained from the MotionStar, a movement-tracking device, and the Spin-T. A within-subject repeated measures design using simultaneous data acquisition was completed. The coefficient of determination (R2) for all planes of cervical range of motion for both model and human data sets was higher than 0.99. The regression equations for the model data showed no significant (P > .05) intercept for flexion-extension and lateral rotation. Human data showed statistically significant intercept for flexion-extension (mean, -0.52 degrees) and lateral flexion (mean, 0.81 degrees) at P < .05. This study quantifies the difference between the MotionStar and the Spin-T goniometer and documents the systematic error between the measures. Where the error reached statistical significance, the magnitude of the error was very small (< 1.5 degrees). The results of this study suggest that the Spin-T goniometer may be used as a valid measuring instrument for cervical range of movement.
- 1 September 2005
- Published by National University of Health Sciences in Journal of Manipulative and Physiological Therapeutics
- Vol. 28 (7) , 487-492
Reliability of the Spin-T Cervical Goniometer in Measuring Cervical Range of Motion in an Asymptomatic Indian Population
To examine the intratester reliability of the Spin-T goniometer, a cervical range of motion device, in a normal Indian population. Subjects comprised 30 healthy adults with mean age of 34 years (range, 18-65 years). The subjects were stabilized in the sitting position and the Spin-T goniometer mounted on the head of the subject. The study design was a within-subject repeated intratester reliability trial conducted for cervical range of motion in 6 directions of movement. Three measurements were taken in each direction (flexion, extension lateral flexion, and lateral rotation) per participant. Reliability coefficients, intraclass correlation coefficients, and 95% confidence interval were derived from repeated-measures analysis of variance (ANOVA). Where differences in ANOVA were detected, a paired t test was conducted and the typical error values and coefficient of variance were calculated. All repeated measures showed high intraclass correlation coefficients (all >0.96, P < .01). The ANOVA detected no differences between trials for all movements except rotation. The typical error values for the rotation trials did not exceed 2.5 degrees and the coefficient of variance did not exceed 4%, which is clinically acceptable considering the normally variable cervical range of movement. In this study, the Spin-T goniometer proved to be a reliable measuring instrument for cervical range of movement in an Indian population. The use of a laser pointer fixed to the instrument ensured a consistent neutral start position.
- 1 September 2005
- Published by National University of Health Sciences in Journal of Manipulative and Physiological Therapeutics
- Vol. 28 (7) , 487-492
Reliability of the Spin-T Cervical Goniometer in Measuring Cervical Range of Motion in an Asymptomatic Indian Population
To examine the intratester reliability of the Spin-T goniometer, a cervical range of motion device, in a normal Indian population. Subjects comprised 30 healthy adults with mean age of 34 years (range, 18-65 years). The subjects were stabilized in the sitting position and the Spin-T goniometer mounted on the head of the subject. The study design was a within-subject repeated intratester reliability trial conducted for cervical range of motion in 6 directions of movement. Three measurements were taken in each direction (flexion, extension lateral flexion, and lateral rotation) per participant. Reliability coefficients, intraclass correlation coefficients, and 95% confidence interval were derived from repeated-measures analysis of variance (ANOVA). Where differences in ANOVA were detected, a paired t test was conducted and the typical error values and coefficient of variance were calculated. All repeated measures showed high intraclass correlation coefficients (all >0.96, P < .01). The ANOVA detected no differences between trials for all movements except rotation. The typical error values for the rotation trials did not exceed 2.5 degrees and the coefficient of variance did not exceed 4%, which is clinically acceptable considering the normally variable cervical range of movement. In this study, the Spin-T goniometer proved to be a reliable measuring instrument for cervical range of movement in an Indian population. The use of a laser pointer fixed to the instrument ensured a consistent neutral start position.