NTNaomi Tanoue

Naomi Tanoue

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Naomi Tanoue has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Hideo Matsumura

    Department of Fixed Prosthodontics, Nihon University School of Dentistry

    6 shared publications
  • Mitsuru Atsuta

    Division of Fixed Prosthodontics and Oral Rehabilitation, Nagasaki University Graduate School of Biomedical Sciences

    6 shared publications
  • H. Matsumura

    Department of Fixed Prosthodontics, Nagasaki University School of Dentistry, Nagasaki, Japan

    4 shared publications
  • M. Atsuta

    Department of Fixed Prosthodontics, Nagasaki University School of Dentistry, Nagasaki, Japan

    4 shared publications
  • Y. Koishi

    Department of Fixed Prosthodontics, Nagasaki University School of Dentistry, Nagasaki, Japan

    3 shared publications
  • Atsushi Mikami

    Department of Fixed Prosthodontics, Nihon University School of Dentistry

    2 shared publications

Latest Publications

  • Open Access

    Effects of Monomer Composition and Original Filler Content on Filler Loading in the Resulting Centrifuged Composites

    by Naomi Tanoue, Atsushi Mikami, Mitsuru Atsuta, Hideo Matsumura

    This study examined the effects of monomer composition, original filler content, and application of centrifugal force on the resulting filler loading of composites. Either Bis-MPEPP or UDMA was mixed with TEGDMA at a molar ratio of 1: 1. Silane-treated silica (14-20 wt%) was added to each mixture. After the mixtures were centrifuged and light-polymerized, rate of increase was determined as the filler increment of 2.0-mm-high, disk-shaped sections of specimen when compared against the uncentrifuged filler content. Both the original filler loading and monomer composition influenced the filler content of the centrifuged composites. Fillers in Bis-MPEPP-based composites exhibited a higher rate of condensation after application of centrifugal force than did UDMA-based composites. The results were suggestive of underlying relationships among the composition, component stability, and post-polymerization properties of flowable composites.


  • Open Access

    Influence of Centrifugal Force on Filler Loading of Resin Composites

    by Naomi Tanoue, Atsushi Mikami, Hiroaki Yanagida, Mitsuru Atsuta, Rie Nomoto, Hideo Matsumura

    This study examined the influence of centrifugal force on the filler loading of composites using a light-polymerizing apparatus combined with a centrifuge. To assess uneven filler particle distribution resulting from specimen rotation, two low-viscosity composites (Palfique Estelite LV and Revolution Formula 2) were placed in test tubes, centrifuged, and subsequently light-polymerized with the apparatus. After each specimen was sliced into four disks (2-mm thickness), the inorganic filler content and Knoop hardness number (KHN) of each disk were determined. The results suggested that filler loading of composites could be increased by application of centrifugal force if the filler and monomer components were properly arranged.


  • Open Access

    Strategic Plan for Reshaping Using Fixed Prosthesis

    by Naomi Tanoue

    Fixed prosthodontics is the art and science of restoring defective or damaged teeth and/or replacing missing teeth. The primary objective of a restoration is to recover functional occlusion. Additionally, patients, regardless of their age and sex, have needs related to esthetic restoration. To please patients, the dentist must deliver an esthetic restoration that blends with the patient's natural teeth. These are some of the needs related to "basic research" in fixed prosthodontics. Either ceramic materials or resin composites are used for indirect esthetic restoration. In general, tooth-colored materials require incremental thicknesses to ensure adequate color and sufficient mechanical properties. However, the thick form of a prosthesis contradicts the concept of "minimal intervention". Patients though require restorations that meet their esthetic needs without any significant loss of tooth structure. The strategy for the "new (advanced) research" in fixed prosthodontics should be based on the two concepts of esthetics and minimal intervention. Although these two factors appear inconsistent, patients unquestionably require both to be provided with high quality care that will include both solutions in the context of a well-organized and sequenced comprehensive treatment plan. Consequently, in response to the growing popularity of esthetic dentistry, we dentists should develop a new dentistry field, one that introduces relevant new technologies along with newly developed materials.

    • 1 April 2005
      • Vol. 18  (2) , 82-6

    Application of a preliminary light-curing unit for enhanced bonding between a gold alloy and veneering materials.

    by Naomi Tanoue, Saiji Shimoe, Mitsuru Atsuta, Hideo Matsumura

    To evaluate the effectiveness of a preliminary light-curing unit when it was used in a procedure to bond veneering material to metal. Two light-activated composite materials (Artglass and Cesead II) were separately placed onto gold alloy disks (Pontol LFC), and polymerized using one of the following three methods: (1) exposure with a high-intensity laboratory light-curing unit (Hyper LII) for 90 seconds; (2) exposure with a preliminary light-curing unit (Targis Quick) for 20 seconds, followed by exposure with the high-intensity unit for 90 seconds; and (3) exposure with the preliminary unit for 90 seconds, followed by exposure with the high-intensity unit for 90 seconds. Shear bond strengths were determined and compared by analysis of variance and post-hoc multiple comparison intervals. The curing depths of the two materials polymerized with the two curing units were determined using a scraping technique described by the International Organization for Standardization (ISO) 4049 with the aim of evaluating the difference in curing performance between the two units. The group polymerized using the preliminary unit for 90 seconds showed statistically improved bond strengths over the group polymerized without the preliminary unit (P < 0.05) regardless of the materials. Regarding the Cesead II material, both groups polymerized using the preliminary unit also indicated significantly improved bond strength compared with the group polymerized with high-intensity only. Also, curing depth results revealed that the high-intensity unit demonstrated greater curing performance than the preliminary unit for both types of materials examined.


  • Open Access

    Color Stability of Acrylic Resin Adhesives with Different Initiation Modes

    by Naomi Tanoue, Yoshikazu Koishi, Hiroaki Yanagida, Mitsuru Atsuta, Kazuki Shimada, Hideo Matsumura

    The purpose of this study was to evaluate the color stability of two acrylic resin adhesives with different activation systems: a benzoyl peroxide (BPO)-amine redox system and a tri-n-butylborane (TBB) derivative system. The colorimetric values of the two resins in different shades (Clear and Ivory) were determined (n=5) 24 hours after polymerization as a baseline using the L* a* b* system of the Commission Internationale de l'Eclairage (CIE). The specimens were thereafter immersed in distilled water, and the color difference (ΔE*) values were calculated. After 24 weeks, the TBB-initiated material showed a significantly (p* values for the BPO-amine-initiated materials were 6.9 for Clear and 15.8 for Ivory, whereas those for the TBB-initiated materials were 1.3 and 1.8 respectively. Thus, it was concluded that the TBB-initiated material had superior color stability to that of the BPO-amine-initiated material.


  • Properties of dual‐curable luting composites polymerized with single and dual curing modes

    by N. Tanoue, Y. Koishi, M. Atsuta, H. Matsumura

    summary  The purpose of this study was to evaluate the influence of visible‐light exposure on water absorption, solubility and colour stability of dual‐curable luting composites. Using eight dual‐curable luting composites (2bond2, Bistite II, G‐Cera Cosmotech II, Imperva Dual, Linkmax, Lute‐It, Panavia Fluoro Cement and Variolink II), disk specimens were prepared by the following two methods: (i) dual‐cured specimens; exposed with visible‐light from a light‐curing unit, and (ii) chemical‐cured specimens; chemically polymerized without exposure. Five specimens were produced for each material and curing mode. Water absorption and solubility were determined according to standardized testing methods, and the data were compared using analysis of variance (anova) and contrasts. With regard to colour stability, the colour difference (ΔE*) values between 24 h and the other immersion periods (1, 2, 3, 4, 8, 12, 16, 20 and 24 weeks) were calculated and then analysed by repeated measure anova. The dual‐cured specimens exhibited significantly lower solubility values than the chemical‐cured specimens except for the Lute‐It material. The dual‐cured Linkmax material exhibited the lowest solubility (0·51 ± 0·01 μg mm−3) and the lowest ΔE* value after 24 weeks (2·64 ± 0·39). The dual‐curable luting composites should be light‐exposed after seating of restorations in order to reduce water absorption and solubility, and to improve colour stability.


  • Properties of a new photo‐activated composite polymerized with three different laboratory photo‐curing units

    by N. Tanoue, M. Atsuta, H. Matsumura

    summary This study determined the hardness, solubility and curing depth of a new photo‐activated composite polymerized with three different laboratory photo‐curing units for the purpose of evaluating the post‐curing properties of the material. A new photo‐activated composite material for both direct and indirect applications (DiamondCrownTM) was polymerized with three photo‐curing units equipped with the following light sources: (i) two halogen lamps (DiamondLite‐VLTM. Halogen Light Curing Booth); (ii) two metal halide lamps (Hyper LII) and (iii) two xenon stroboscopic tubes (UniXS II). Knoop hardness, water solubility and curing depth were determined for groups of five specimens according to standardized testing methods. All data were compared using analysis of variance (anova) and Scheffe's S intervals (P < 0·05). The Knoop hardness number (KHN) generated with the metal halide unit (63·3 ± 2·4 KHN) was statistically (P < 0·05) greater than those produced by the other two curing units. Water solubility values for both the halogen unit (2·5 ± 0·5 μg mm−3) and the metal halide unit (2·5 ± 0·5 μg mm−3) were significantly (P < 0·05) lower than for the xenon unit (3·8 ± 0·5 μg mm−3). Of the three photo‐curing units, the metal halide curing‐unit consistently exhibited the greatest depth of cure. The composite material appears to be reliable, although its post‐curing properties were found to be influenced by the type of curing unit.


  • Influence of visible‐light exposure on colour stability of current dual‐curable luting composites

    by Y. Koishi, N. Tanoue, M. Atsuta, H. Matsumura

    This study was conducted to evaluate influence of visible‐light exposure on colour stability of dual‐curable luting composite. Using six dual‐curable luting composites [Bistite II (BI), Clapearl DC (CL), Dicor Light Activated Cement (DI), G‐Cera Cosmotech II (GC), Lute‐It (LU) and Variolink II (VA), disk specimens were prepared with the following two methods: (i) dual‐cured specimens, exposure with visible‐light from a photo‐curing unit for 120 s and (ii) chemical‐cured specimens, chemically cured without exposure. Five specimens were produced for each material and curing mode. After 24 h, all specimens were immersed in distilled water at 37 °C for 24 weeks, during which colour accuracy was measured with a dental colorimeter. The colours characterized in the Commission Internationale d'Eclairage (CIE) L*a*b* colour space were first determined 24 h after preparation (baseline colour evaluation), and again after 1, 2, 3, 4, 8, 12, 16 and 24 weeks. The colour difference (ΔE*) values between 24 h and the other immersion periods were calculated, and then analysed by repeated measure analysis of variance (ANOVA). In addition, the ΔE* values after 24 weeks for dual‐cured specimens were compared with those for chemical‐cured specimens by one‐way ANOVA and by contrasts for each composite (P < 0·05). The ΔE* values were influenced by the material and curing mode as well as immersion period (P=0·0001). After 24 weeks the dual‐cured specimens showed significantly lower ΔE* values than the chemical‐cured specimens, except for the VA material. The CL material exhibited the least colour change (1·9 ± 0·2) among the dual‐cured specimens, and the VA material showed the least (4·5 ± 0·9) among the chemical‐cured specimens after 24 weeks. Dual‐curable luting composites should be polymerized with the dual modes to ensure colour stability.