H. Sugita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
H. Sugita has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
K. Shinozaki
Japan Aerospace Exploration Agency (Japan)
3 shared publicationsT. Nakagawa
Japan Aerospace Exploration Agency (Japan)
3 shared publications- Caroline A. Kilbourne
NASA / Goddard Space Flight Center
2 shared publications - Dan McCammon
Department of Physics, University of Wisconsin-Madison, Madison, WI, USA
2 shared publications J. W. Den Herder
SRON National Institute for Space Research (Netherlands)
2 shared publicationsK. Kanao
Sumitomo Heavy Industries, Ltd. (Japan)
2 shared publications
Latest Publications
- 16 July 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7731, 77314G
Conceptual design of a cryogenic system for the next-generation infrared space telescope SPICA
The conceptual design of the Space Infrared Telescope for Cosmology and Astrophysics (SPICA) has been studied as a pre-project of the Japan Aerospace Exploration Agency (JAXA) in collaboration with ESA to be launched in 2018. The SPICA is transferred into a halo orbit around the second Lagrangian point in the Sun-Earth system, where radiant cooling is available effectively. The SPICA has a large IR telescope 3 m in diameter, which is cooled without cryogen to below 6 K by the radiant and mechanical cooling system. Therefore, the SPICA mission will cover mid- and far-IR astronomy with high sensitivity and spatial resolution during a long period of over 5 years for goal. Most heat radiation from the sun and spacecraft is blocked by the Sun Shield and thermal radiation shields covered with Multi-Layer Insulator (MLI) to limit heat radiation to the Scientific Instrument Assembly (SIA). The SIA, which is composed of the primary mirrors and optical benches equipped with Focal Plane Instruments (FPIs), is refrigerated to below 6 K by two sets of 4K-class Joule-Thomson (JT) cooler with a cooling power of 40 mW at 4.5 K. The Far-IR detector is refrigerated to 1.7 K by two sets of 1K-class JT coolers with a cooling power of 10 mW at 1.7 K. Improvements for the higher reliability and sufficient cooling performance are required in the development of SPICA mechanical cryocoolers. Thermal analysis indicates that the SPICA cryogenic system works effectively to limit the total heat load on the SIA to 41.2 mW. This paper describes the conceptual design of the SPICA cryogenic system, which was established with thermal feasibility for nominal operation mode.
- 16 July 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7731, 77314G
Conceptual design of a cryogenic system for the next-generation infrared space telescope SPICA
The conceptual design of the Space Infrared Telescope for Cosmology and Astrophysics (SPICA) has been studied as a pre-project of the Japan Aerospace Exploration Agency (JAXA) in collaboration with ESA to be launched in 2018. The SPICA is transferred into a halo orbit around the second Lagrangian point in the Sun-Earth system, where radiant cooling is available effectively. The SPICA has a large IR telescope 3 m in diameter, which is cooled without cryogen to below 6 K by the radiant and mechanical cooling system. Therefore, the SPICA mission will cover mid- and far-IR astronomy with high sensitivity and spatial resolution during a long period of over 5 years for goal. Most heat radiation from the sun and spacecraft is blocked by the Sun Shield and thermal radiation shields covered with Multi-Layer Insulator (MLI) to limit heat radiation to the Scientific Instrument Assembly (SIA). The SIA, which is composed of the primary mirrors and optical benches equipped with Focal Plane Instruments (FPIs), is refrigerated to below 6 K by two sets of 4K-class Joule-Thomson (JT) cooler with a cooling power of 40 mW at 4.5 K. The Far-IR detector is refrigerated to 1.7 K by two sets of 1K-class JT coolers with a cooling power of 10 mW at 1.7 K. Improvements for the higher reliability and sufficient cooling performance are required in the development of SPICA mechanical cryocoolers. Thermal analysis indicates that the SPICA cryogenic system works effectively to limit the total heat load on the SIA to 41.2 mW. This paper describes the conceptual design of the SPICA cryogenic system, which was established with thermal feasibility for nominal operation mode.
- 12 July 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7011, 70113R
Design of the two-stage series adiabatic demagnetization refrigerator for the NeXT and Spectrum-RG missions
The SXS (Soft X-ray Spectrometer) onboard the coming Japanese X-ray satellite NeXT (New Exploration Xray Telescope) and the SXC (Spectrum-RG X-ray Calorimeter) in Spectrum-RG mission are microcalorimeter array spectrometers which will achieve high spectral resolution of ~ 6 eV in 0.3-10.0 keV energy band. These spectrometers are well-suited to address key problems in high-energy astrophysics. To achieve these high spectral sensitivities, these detectors require to be operated under 50 mK by using very efficient cooling systems including adiabatic demagnetization refrigerator (ADR). For both missions, we propose a two-stage series ADR as a cooling system below 1 K, in which two units of ADR consists of magnetic cooling material, a superconducting magnet, and a heat switch are operated step by step. Three designs of the ADR are proposed for SXS/SXC. In all three designs, ADR can attain the required hold time of 23 hours at 50 mK and cooling power of 0.4μW with a low magnetic fields (1.5/1.5 Tesla or 2.0/3.0 Tesla) in a small configuration (180 mmφ× 319 mm in length). We also fabricated a new portable refrigerator for a technology investigation of two-stage ADR. Two units of ADR have been installed at the bottom of liquid He tank. By using this dewar, important technologies such as an operation of two-stage cooling cycle, tight temperature control less than 1 μK (in rms) stability, a magnetic shielding, saltpills, and gas-gap heat switches are evaluated.
- 12 July 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7011, 70113R
Design of the two-stage series adiabatic demagnetization refrigerator for the NeXT and Spectrum-RG missions
The SXS (Soft X-ray Spectrometer) onboard the coming Japanese X-ray satellite NeXT (New Exploration Xray Telescope) and the SXC (Spectrum-RG X-ray Calorimeter) in Spectrum-RG mission are microcalorimeter array spectrometers which will achieve high spectral resolution of ~ 6 eV in 0.3-10.0 keV energy band. These spectrometers are well-suited to address key problems in high-energy astrophysics. To achieve these high spectral sensitivities, these detectors require to be operated under 50 mK by using very efficient cooling systems including adiabatic demagnetization refrigerator (ADR). For both missions, we propose a two-stage series ADR as a cooling system below 1 K, in which two units of ADR consists of magnetic cooling material, a superconducting magnet, and a heat switch are operated step by step. Three designs of the ADR are proposed for SXS/SXC. In all three designs, ADR can attain the required hold time of 23 hours at 50 mK and cooling power of 0.4μW with a low magnetic fields (1.5/1.5 Tesla or 2.0/3.0 Tesla) in a small configuration (180 mmφ× 319 mm in length). We also fabricated a new portable refrigerator for a technology investigation of two-stage ADR. Two units of ADR have been installed at the bottom of liquid He tank. By using this dewar, important technologies such as an operation of two-stage cooling cycle, tight temperature control less than 1 μK (in rms) stability, a magnetic shielding, saltpills, and gas-gap heat switches are evaluated.
- 12 July 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7011, 70110K
The Spektr-RG x-ray calorimeter
Spatially resolved X-ray spectroscopy with high spectral resolution allows the study of astrophysical processes in extended sources with unprecedented sensitivity. This includes the measurement of abundances, temperatures, densities, ionisation stages as well as turbulence and velocity structures in these sources. An X-ray calorimeter is planned for the Russian mission Spektr Röntgen-Gamma (SRG), to be launched in 2011. During the first half year (pointed phase) it will study the dynamics and composition of of the hot gas in massive clusters of galaxies and in supernova remnants (SNR). During the survey phase it will produce the first all sky maps of line-rich spectra of the interstellar medium (ISM). Spectral analysis will be feasible for typically every 5° x 5° region on the sky. Considering the very short time-scale for the development of this instrument it consists of a combination of well developed systems. For the optics an extra eROSITA mirror, also part of the Spektr-RG payload, will be used. The detector will be based on spare parts of the detector flown on Suzaku combined with a rebuild of the electronics and the cooler will be based on the design for the Japanese mission NeXT. In this paper we will present the science and give an overview of the instrument.
- 12 July 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7011, 70110K
The Spektr-RG x-ray calorimeter
Spatially resolved X-ray spectroscopy with high spectral resolution allows the study of astrophysical processes in extended sources with unprecedented sensitivity. This includes the measurement of abundances, temperatures, densities, ionisation stages as well as turbulence and velocity structures in these sources. An X-ray calorimeter is planned for the Russian mission Spektr Röntgen-Gamma (SRG), to be launched in 2011. During the first half year (pointed phase) it will study the dynamics and composition of of the hot gas in massive clusters of galaxies and in supernova remnants (SNR). During the survey phase it will produce the first all sky maps of line-rich spectra of the interstellar medium (ISM). Spectral analysis will be feasible for typically every 5° x 5° region on the sky. Considering the very short time-scale for the development of this instrument it consists of a combination of well developed systems. For the optics an extra eROSITA mirror, also part of the Spektr-RG payload, will be used. The detector will be based on spare parts of the detector flown on Suzaku combined with a rebuild of the electronics and the cooler will be based on the design for the Japanese mission NeXT. In this paper we will present the science and give an overview of the instrument.
- 1 September 1994
- Vol. 63 (5) , 181-5
[Recurrent dislocation of the elbow].
A case of a recurrent dislocation of the elbow joint in a 13-year-old female is described. The patient sustained a medial epicondylar fracture of the humerus and consulted us four months later. There was no deformity but marked lateral instability of the elbow was recognized. It could be fully flexed and hyperextended ca 20 degrees. The elbow joint could be easily dislocated by pronation of the hyperextended elbow. Roentgenogram demonstrated an apparent non-union of the medial epicondylar fracture. The fragment was repositioned so that the medial collateral ligament became taut. There was no recurrence of the dislocation ten months postoperatively.
- 1 September 1994
- Vol. 63 (5) , 181-5
[Recurrent dislocation of the elbow].
A case of a recurrent dislocation of the elbow joint in a 13-year-old female is described. The patient sustained a medial epicondylar fracture of the humerus and consulted us four months later. There was no deformity but marked lateral instability of the elbow was recognized. It could be fully flexed and hyperextended ca 20 degrees. The elbow joint could be easily dislocated by pronation of the hyperextended elbow. Roentgenogram demonstrated an apparent non-union of the medial epicondylar fracture. The fragment was repositioned so that the medial collateral ligament became taut. There was no recurrence of the dislocation ten months postoperatively.