Sylvie Charbonnier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sylvie Charbonnier has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Alexis Lebranchu
Valemo S.A.S, F-33323 Bègles, France
2 shared publications - Aurélie Campagne
Affiliations: Univ Grenoble Alpes, Laboratoire de Psychologie et Neurocognition (LPNC), Grenoble, France, Centre national de Recherche Scientifique, LPNC, Grenoble, France
2 shared publications - Christelle Godin
CEA-Leti Minatec Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 09, France
2 shared publications - Christophe Bérenguer
Université Grenoble Alpes, CNRS, Grenoble INP, GIPSA-lab, 38000 Grenoble, France
2 shared publications - Frederic Prevost
Valemo S.A.S, F-33323 Bègles, France
2 shared publications - Gaël Vila
Univ Lyon, INSA Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, France
2 shared publications
Latest Publications
- Open Access
Real-Time Quality Index to Control Data Loss in Real-Life Cardiac Monitoring Applications
Wearable cardiac sensors pave the way for advanced cardiac monitoring applications based on heart rate variability (HRV). In real-life settings, heart rate (HR) measurements are subject to motion artifacts that may lead to frequent data loss (missing samples in the HR signal), especially for commercial devices based on photoplethysmography (PPG). The current study had two main goals: (i) to provide a white-box quality index that estimates the amount of missing samples in any piece of HR signal; and (ii) to quantify the impact of data loss on feature extraction in a PPG-based HR signal. This was done by comparing real-life recordings from commercial sensors featuring both PPG (Empatica E4) and ECG (Zephyr BioHarness 3). After an outlier rejection process, our quality index was used to isolate portions of ECG-based HR signals that could be used as benchmark, to validate the output of Empatica E4 at the signal level and at the feature level. Our results showed high accuracy in estimating the mean HR (median error: 3.2%), poor accuracy for short-term HRV features (e.g., median error: 64% for high-frequency power), and mild accuracy for longer-term HRV features (e.g., median error: 25% for low-frequency power). These levels of errors could be reduced by using our quality index to identify time windows with few or no data loss (median errors: 0.0%, 27%, and 6.4% respectively, when no sample was missing). This quality index should be useful in future work to extract reliable cardiac features in real-life measurements, or to conduct a field validation study on wearable cardiac sensors.
Open AccessReal-Time Quality Index to Control Data Loss in Real-Life Cardiac Monitoring Applications
Wearable cardiac sensors pave the way for advanced cardiac monitoring applications based on heart rate variability (HRV). In real-life settings, heart rate (HR) measurements are subject to motion artifacts that may lead to frequent data loss (missing samples in the HR signal), especially for commercial devices based on photoplethysmography (PPG). The current study had two main goals: (i) to provide a white-box quality index that estimates the amount of missing samples in any piece of HR signal; and (ii) to quantify the impact of data loss on feature extraction in a PPG-based HR signal. This was done by comparing real-life recordings from commercial sensors featuring both PPG (Empatica E4) and ECG (Zephyr BioHarness 3). After an outlier rejection process, our quality index was used to isolate portions of ECG-based HR signals that could be used as benchmark, to validate the output of Empatica E4 at the signal level and at the feature level. Our results showed high accuracy in estimating the mean HR (median error: 3.2%), poor accuracy for short-term HRV features (e.g., median error: 64% for high-frequency power), and mild accuracy for longer-term HRV features (e.g., median error: 25% for low-frequency power). These levels of errors could be reduced by using our quality index to identify time windows with few or no data loss (median errors: 0.0%, 27%, and 6.4% respectively, when no sample was missing). This quality index should be useful in future work to extract reliable cardiac features in real-life measurements, or to conduct a field validation study on wearable cardiac sensors.
- Open Access
- 26 April 2019
- Published by MDPI AG in Future Internet
- Vol. 11 (5) , 102
Real-Time Monitoring of Passenger’s Psychological Stress
This article addresses the question of passengers’ experience through different transport modes. It presents the main results of a pilot study, for which stress levels experienced by a traveller were assessed and predicted over two long journeys. Accelerometer measures and several physiological signals (electrodermal activity, blood volume pulse and skin temperature) were recorded using a smart wristband while travelling from Grenoble to Bilbao. Based on user’s feedback, three events of high stress and one period of moderate activity with low stress were identified offline. Over these periods, feature extraction and machine learning were performed from the collected sensor data to build a personalized regressive model, with user’s stress levels as output. A smartphone application has been developed on its basis, in order to record and visualize a timely estimated stress level using traveler’s physiological signals. This setting was put on test during another travel from Grenoble to Brussels, where the same user’s stress levels were predicted in real time by the smartphone application. The number of correctly classified stress-less time windows ranged from 92.6% to 100%, depending on participant’s level of activity. By design, this study represents a first step for real-life, ambulatory monitoring of passenger’s stress while travelling.
- 26 April 2019
- Published by MDPI AG in Future Internet
- Vol. 11 (5) , 102
Open AccessReal-Time Monitoring of Passenger’s Psychological Stress
This article addresses the question of passengers’ experience through different transport modes. It presents the main results of a pilot study, for which stress levels experienced by a traveller were assessed and predicted over two long journeys. Accelerometer measures and several physiological signals (electrodermal activity, blood volume pulse and skin temperature) were recorded using a smart wristband while travelling from Grenoble to Bilbao. Based on user’s feedback, three events of high stress and one period of moderate activity with low stress were identified offline. Over these periods, feature extraction and machine learning were performed from the collected sensor data to build a personalized regressive model, with user’s stress levels as output. A smartphone application has been developed on its basis, in order to record and visualize a timely estimated stress level using traveler’s physiological signals. This setting was put on test during another travel from Grenoble to Brussels, where the same user’s stress levels were predicted in real time by the smartphone application. The number of correctly classified stress-less time windows ranged from 92.6% to 100%, depending on participant’s level of activity. By design, this study represents a first step for real-life, ambulatory monitoring of passenger’s stress while travelling.
- Open Access
- 1 April 2019
- Published by Elsevier in ISA Transactions
- Vol. 87, 272-281
A combined mono- and multi-turbine approach for fault indicator synthesis and wind turbine monitoring using SCADA data
- 1 April 2019
- Published by Elsevier in ISA Transactions
- Vol. 87, 272-281
Open AccessA combined mono- and multi-turbine approach for fault indicator synthesis and wind turbine monitoring using SCADA data
- Open Access
- 30 June 2018
- Published by PHM Society in Phm Society European Conference
- Vol. 4 (1)
Simulation of wind turbine faulty production profiles and performance assessment of fault monitoring methods
Wind turbines being one of the fastest growing sources of renewable energy have garnered significant scientific interest for the monitoring and fault analysis using SCADA data. Various monitoring approaches using power curves, i.e. industry wide characteristic curves expressing produced power as a function of wind speed, have been proposed in the literature. However, an objective comparison of the performance of these methods is difficult. The difficulty comes from (i) the variability in operational and environmental conditions taken into account; (ii) the nature, size and type of data-sets used and (iii) the type and signatures of faults considered for validation. To solve this problem, an approach with a twofold contribution is proposed in this work: 1) an original procedure to generate realistic and controlled simulations of 10 minutes SCADA data, simulating situations when the wind turbine is operating in normal or faulty conditions, is presented; 2) a framework for objective performance assessment of the fault detection methods, based on the proposed controlled and standardized simulation scheme is presented. Objective performance evaluation metrics, such as detection probability and false alarm rates are computed and represented as characteristic Receiver Operating Curves (ROC). The proposed simulation approach is shown to provide a useful global framework for objective performance analysis. A number of realistically simulated and controlled data streams are used to compare and discuss the performances of two fault detection methods referenced in the literature.
- 30 June 2018
- Published by PHM Society in Phm Society European Conference
- Vol. 4 (1)
Open AccessSimulation of wind turbine faulty production profiles and performance assessment of fault monitoring methods
Wind turbines being one of the fastest growing sources of renewable energy have garnered significant scientific interest for the monitoring and fault analysis using SCADA data. Various monitoring approaches using power curves, i.e. industry wide characteristic curves expressing produced power as a function of wind speed, have been proposed in the literature. However, an objective comparison of the performance of these methods is difficult. The difficulty comes from (i) the variability in operational and environmental conditions taken into account; (ii) the nature, size and type of data-sets used and (iii) the type and signatures of faults considered for validation. To solve this problem, an approach with a twofold contribution is proposed in this work: 1) an original procedure to generate realistic and controlled simulations of 10 minutes SCADA data, simulating situations when the wind turbine is operating in normal or faulty conditions, is presented; 2) a framework for objective performance assessment of the fault detection methods, based on the proposed controlled and standardized simulation scheme is presented. Objective performance evaluation metrics, such as detection probability and false alarm rates are computed and represented as characteristic Receiver Operating Curves (ROC). The proposed simulation approach is shown to provide a useful global framework for objective performance analysis. A number of realistically simulated and controlled data streams are used to compare and discuss the performances of two fault detection methods referenced in the literature.
- 1 November 2014
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 117 (2) , 247-256
Feature extraction of the first difference of EMG time series for EMG pattern recognition
- 1 November 2014
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 117 (2) , 247-256
Feature extraction of the first difference of EMG time series for EMG pattern recognition
- 1 January 2014
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 47 (3) , 2963-2968
Detection of mental fatigue using an active BCI inspired signal processing chain
- 1 January 2014
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 47 (3) , 2963-2968
Detection of mental fatigue using an active BCI inspired signal processing chain
- 1 January 2012
- Published by Springer Nature
- p. 281-290
Vehicle Re-Identification With Several Magnetic Sensors
- 1 January 2012
- Published by Springer Nature
- p. 281-290
Vehicle Re-Identification With Several Magnetic Sensors
- 2 November 2011
- Published by Springer Nature in Machine Vision and Applications
- Vol. 23 (6) , 1195-1208
Using retina modelling to characterize blinking: comparison between EOG and video analysis
- 2 November 2011
- Published by Springer Nature in Machine Vision and Applications
- Vol. 23 (6) , 1195-1208
Using retina modelling to characterize blinking: comparison between EOG and video analysis
- 1 June 2011
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 41 (6) , 380-389
Self-evaluated automatic classifier as a decision-support tool for sleep/wake staging
- 1 June 2011
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 41 (6) , 380-389
Self-evaluated automatic classifier as a decision-support tool for sleep/wake staging