A. Seidman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
A. Seidman has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Pier Giorgio Rancoita
INFN, Milano-Bicocca, Milano, Italy
5 shared publications N. Croitoru
4 shared publicationsA. Penzo
3 shared publicationsC. Furetta
3 shared publicationsC. Leroy
3 shared publicationsE. Borchi
3 shared publications
Latest Publications
- 6 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 87-89 vol.1
Integrated micro SAW resonator using longitudinal perturbations
A micro SAW (surface acoustic wave) resonator has been developed which is suitable for integrated acoustics applications because it overcomes size limitations associated with conventional resonators. Analytical expressions are presented for incident and reflected fields in a periodically perturbed acoustic waveguide resonator, based on a corrugated waveguide of a given length in a grating configuration. Based on these calculations, two kinds of devices were developed and tested: (1) a corrugated waveguide filter and (2) microresonator structured. In addition experimental results are presented on microresonator devices on conventional YZLiNbO/sub 3/. A guided micro-resonator enables one to reduce the transducers' size since its energy should be focused to a narrow waveguide. This size reduction along with focusing by an acoustic lens confines the incident acoustic waves to the waveguides and enables integration of several elements on one crystal surface. This virtual insulation avoids crosstalk distortions between unwanted signals.
- 6 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 87-89 vol.1
Integrated micro SAW resonator using longitudinal perturbations
A micro SAW (surface acoustic wave) resonator has been developed which is suitable for integrated acoustics applications because it overcomes size limitations associated with conventional resonators. Analytical expressions are presented for incident and reflected fields in a periodically perturbed acoustic waveguide resonator, based on a corrugated waveguide of a given length in a grating configuration. Based on these calculations, two kinds of devices were developed and tested: (1) a corrugated waveguide filter and (2) microresonator structured. In addition experimental results are presented on microresonator devices on conventional YZLiNbO/sub 3/. A guided micro-resonator enables one to reduce the transducers' size since its energy should be focused to a narrow waveguide. This size reduction along with focusing by an acoustic lens confines the incident acoustic waves to the waveguides and enables integration of several elements on one crystal surface. This virtual insulation avoids crosstalk distortions between unwanted signals.
- Open Access
- 1 August 1996
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 378 (3) , 427-431
Test system for an optical readout chain of a silicon microstrip detector
- 1 August 1996
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 378 (3) , 427-431
Open AccessTest system for an optical readout chain of a silicon microstrip detector
- 1 April 1991
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 38 (2) , 403-407
Evidence for compensation and study of lateral shower development in Si/U hadron calorimeters
- 1 April 1991
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 38 (2) , 403-407
Evidence for compensation and study of lateral shower development in Si/U hadron calorimeters
- 1 June 1990
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 67 (11) , 6675-6681
Novel types of surface acoustic wave microreflectors: Performance analysis and simulations
- 1 June 1990
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 67 (11) , 6675-6681
Novel types of surface acoustic wave microreflectors: Performance analysis and simulations
- 1 June 1990
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 37 (3) , 1186-1190
The compensation condition in hadron calorimeters by the filtering effect
- 1 June 1990
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 37 (3) , 1186-1190
The compensation condition in hadron calorimeters by the filtering effect
- 1 August 1989
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 66 (3) , 1428-1434
Distributed feedback guided surface acoustic wave microresonator
Surface acoustic wave resonators have been used in a number of applications: high-Q frequency filtering, very accurate frequency sources, etc. A major disadvantage of conventional resonators is their large dimensions, which makes them inadequate for integrated acoustics applications. In order to overcome these size limitations a new type of microresonator was designed, developed, and tested. In this paper, theoretical calculations and measurements on two kinds of such devices (a corrugated waveguide filter and a microresonator structure) are presented and their possible applications are discussed.
- 1 August 1989
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 66 (3) , 1428-1434
Distributed feedback guided surface acoustic wave microresonator
Surface acoustic wave resonators have been used in a number of applications: high-Q frequency filtering, very accurate frequency sources, etc. A major disadvantage of conventional resonators is their large dimensions, which makes them inadequate for integrated acoustics applications. In order to overcome these size limitations a new type of microresonator was designed, developed, and tested. In this paper, theoretical calculations and measurements on two kinds of such devices (a corrugated waveguide filter and a microresonator structure) are presented and their possible applications are discussed.
- 1 February 1989
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 36 (1) , 331-333
Compensation condition in Si/U hadronic calorimeter
- 1 February 1989
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 36 (1) , 331-333
Compensation condition in Si/U hadronic calorimeter
- 1 April 1988
- Published by IOP Publishing in Physica Scripta
- Vol. 37 (4) , 555-558
Secondary electron emission of Zno sputtered films
- 1 April 1988
- Published by IOP Publishing in Physica Scripta
- Vol. 37 (4) , 555-558
Secondary electron emission of Zno sputtered films
- 1 January 1985
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 57 (1) , 102-104
Physical properties of SnOx films
SnOx films with different values of x were deposited by rf sputtering. Secondary emission yield δ, physical density γ, and electrical resistivity ρ of the films were investigated. Higher values of δ than those of bulk SnO and SnO2 were found. From the experiment it results that δ, γ, and ρ increase with the increase of x. The crossover energy Ec, the primary electron energy for δ=1, decreases with x. Analysis of the experimental data and theory leads to the conclusion that the main factor which determines the maximum secondary electron emission yield δm is the ratio between the escape probability and the work function.
- 1 January 1985
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 57 (1) , 102-104
Physical properties of SnOx films
SnOx films with different values of x were deposited by rf sputtering. Secondary emission yield δ, physical density γ, and electrical resistivity ρ of the films were investigated. Higher values of δ than those of bulk SnO and SnO2 were found. From the experiment it results that δ, γ, and ρ increase with the increase of x. The crossover energy Ec, the primary electron energy for δ=1, decreases with x. Analysis of the experimental data and theory leads to the conclusion that the main factor which determines the maximum secondary electron emission yield δm is the ratio between the escape probability and the work function.
- 1 January 1985
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 32 (1) , 723-726
Undepleted Silicon Detectors
Large-size silicon detectors employing relatively low resistivity material can be used in electrcmagnetic calorimetry. They can operate in strong magnetic fields, under geometric constraints and with microstrip detectors a high resolution can be achieved. Low noise large capacitance oriented electronics was developed to enable good signal-to-noise ratio for single relativistic particles traversing large area detectors. In undepleted silicon detectors, the charge migration from the field-free region has been investigated by comparing the expected peak position (from the depleted layer only) of the energy-loss of relativistic electrons with the measured one. Furthermore, the undepleted detectors have been employed in a prototype of Si/W electromagnetic colorimeter. The sensitive layer was found to be systematically larger than the depleted one.
- 1 January 1985
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 32 (1) , 723-726
Undepleted Silicon Detectors
Large-size silicon detectors employing relatively low resistivity material can be used in electrcmagnetic calorimetry. They can operate in strong magnetic fields, under geometric constraints and with microstrip detectors a high resolution can be achieved. Low noise large capacitance oriented electronics was developed to enable good signal-to-noise ratio for single relativistic particles traversing large area detectors. In undepleted silicon detectors, the charge migration from the field-free region has been investigated by comparing the expected peak position (from the depleted layer only) of the energy-loss of relativistic electrons with the measured one. Furthermore, the undepleted detectors have been employed in a prototype of Si/W electromagnetic colorimeter. The sensitive layer was found to be systematically larger than the depleted one.