Alfonso Fernández Timón
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alfonso Fernández Timón has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Miguel Jurado Vargas
Departamento de Física, Universidad de Extremadura, 06071 Badajoz, Spain
14 shared publications - Alejandro Martín Sánchez
Department of Physics, University of Extremadura, Badajoz, Spain
5 shared publications M. Jurado Vargas
3 shared publicationsA.B. Ruano Sánchez
1 shared publicationC. Peña Morante
1 shared publicationC.J Bland
Department of Physics and Astronomy, University of Calgary, Calgary, Alberta, Canada T2N 1N4
1 shared publication
Latest Publications
- 17 March 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 233
Influence of the low-energy backscattering spectrum on the calibration of thin alpha-particle sources
- 17 March 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 233
Influence of the low-energy backscattering spectrum on the calibration of thin alpha-particle sources
- 1 April 2022
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 196
α-SpecTrim: A new application designed for reproducing alpha-particle spectra
- 1 April 2022
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 196
α-SpecTrim: A new application designed for reproducing alpha-particle spectra
- 1 May 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 135, 78-82
ALPHACAL: A new user-friendly tool for the calibration of alpha-particle sources
- 1 May 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 135, 78-82
ALPHACAL: A new user-friendly tool for the calibration of alpha-particle sources
- Open Access
- 1 September 2015
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 60 (3) , 651-655
Application of the new Monte Carlo code AlfaMC to the calibration of alpha-particle sources
Measurements of α-particle sources require corrections to the counting rate due to scattering and self-absorption in the source and the backing material. In this study, we describe a simple procedure to estimate these corrections using the new Monte Carlo code AlfaMC to consider the effects of scattering and self-absorption conjointly, and so to determine the activity of α emitters. The procedure proposed was applied to 235UO2 sources deposited on highly polished platinum backings. In general, the dependence of the efficiency with source thickness was in good agreement with a simple model considering a linear and a hyperbolic behavior for thin and thick sources, respectively, although significant deviations from this model were found for very thin sources. For these very thin sources, the Monte Carlo simulation revealed to be as a required method in the primary calibration of α-particle sources. The efficiency results obtained by simulation with AlfaMC were in agreement with available efficiency data.
- 1 September 2015
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 60 (3) , 651-655
Open AccessApplication of the new Monte Carlo code AlfaMC to the calibration of alpha-particle sources
Measurements of α-particle sources require corrections to the counting rate due to scattering and self-absorption in the source and the backing material. In this study, we describe a simple procedure to estimate these corrections using the new Monte Carlo code AlfaMC to consider the effects of scattering and self-absorption conjointly, and so to determine the activity of α emitters. The procedure proposed was applied to 235UO2 sources deposited on highly polished platinum backings. In general, the dependence of the efficiency with source thickness was in good agreement with a simple model considering a linear and a hyperbolic behavior for thin and thick sources, respectively, although significant deviations from this model were found for very thin sources. For these very thin sources, the Monte Carlo simulation revealed to be as a required method in the primary calibration of α-particle sources. The efficiency results obtained by simulation with AlfaMC were in agreement with available efficiency data.
- 14 February 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 305 (2) , 479-485
A comparison between the codes SRIM and AlfaMC in the Monte Carlo simulation of alpha-particle backscattering
- 14 February 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 305 (2) , 479-485
A comparison between the codes SRIM and AlfaMC in the Monte Carlo simulation of alpha-particle backscattering
- 1 January 2015
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 106, 199-203
Study of backscattering in alpha-particle sources with the new code AlfaMC
- 1 January 2015
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 106, 199-203
Study of backscattering in alpha-particle sources with the new code AlfaMC
- 8 June 2014
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 302 (1) , 297-302
Application of alpha particle transport to the modelization of efficiency curves in proportional counters
- 8 June 2014
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 302 (1) , 297-302
Application of alpha particle transport to the modelization of efficiency curves in proportional counters
- 1 December 2013
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 82, 376-381
Influence of source composition and particle energy on the determination of gross alpha activity
- 1 December 2013
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 82, 376-381
Influence of source composition and particle energy on the determination of gross alpha activity
- 1 November 2011
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 292 (2) , 571-577
Alpha-particle energy distributions from thin sources measured with small solid angles
- 1 November 2011
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 292 (2) , 571-577
Alpha-particle energy distributions from thin sources measured with small solid angles