Dinesh Narayana Naik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dinesh Narayana Naik has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Mitsuo Takeda
Institut für Technische Optik, Universität Stuttgart, Pfaffenwaldring 9, 70569 Stuttgart, Germany
4 shared publicationsGiancarlo Pedrini
Institut für Technische Optik, Universität Stuttgart, Pfaffenwaldring 9, 70569 Stuttgart, Germany
3 shared publicationsWolfgang Osten
Institut für Technische Optik, Universität Stuttgart, Pfaffenwaldring 9, 70569 Stuttgart, Germany
3 shared publicationsRakesh Kumar Singh
Department of Physics, Indian Institute of Space Science and Technology, Thiruvananthapuram, Kerala 695547, India
2 shared publicationsYoko Miyamoto
Department of Engineering Science, The University of Electro-Communications, 1-5-1, Chofugaoka, Chofu,Tokyo 182-8585, Japan
2 shared publications- Giancarlo Pedrini
Univ. Stuttgart (Germany)
1 shared publication
Latest Publications
- 21 March 2014
- Published by Optica Publishing Group in Optics Letters
- Vol. 39 (7) , 1857-1860
Spectrally resolved incoherent holography: 3D spatial and spectral imaging using a Mach–Zehnder radial-shearing interferometer
Spatial and spectral information holds the key for characterizing incoherently illuminated or self-luminous objects, as well as for imaging fluorescence. We propose spectrally resolved incoherent holography using a multifunctional Mach–Zehnder interferometer that can introduce both a radial shear and a variable time delay between the interfering optical fields and permits the measurement of both spatial and temporal coherence functions, from which a 3D spatial and spectral image of the object is reconstructed. We propose and demonstrate the accurate 3D imaging of the object spectra by in situ calibration.
- 21 March 2014
- Published by Optica Publishing Group in Optics Letters
- Vol. 39 (7) , 1857-1860
Spectrally resolved incoherent holography: 3D spatial and spectral imaging using a Mach–Zehnder radial-shearing interferometer
Spatial and spectral information holds the key for characterizing incoherently illuminated or self-luminous objects, as well as for imaging fluorescence. We propose spectrally resolved incoherent holography using a multifunctional Mach–Zehnder interferometer that can introduce both a radial shear and a variable time delay between the interfering optical fields and permits the measurement of both spatial and temporal coherence functions, from which a 3D spatial and spectral image of the object is reconstructed. We propose and demonstrate the accurate 3D imaging of the object spectra by in situ calibration.
- 1 January 2014
- Published by Springer Nature
- p. 715-718
Recording of 3D Spatial and Spectral Information of Self-luminous Objects Using a Mach-Zehnder Radial Shearing Interferometer
- 1 January 2014
- Published by Springer Nature
- p. 715-718
Recording of 3D Spatial and Spectral Information of Self-luminous Objects Using a Mach-Zehnder Radial Shearing Interferometer
- 3 May 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8776, 87760B
Digital holography for recording of incoherent-object hologram as complex spatial coherence function
We propose and demonstrate the recording of hologram of an incoherently illuminated object by using a Sagnac radial shearing interferometer, a Pockels cell and an 8 bit CCD camera. An approach based on statistical optics is used for understanding the concept of recording of an incoherent-object as complex spatial coherence function. The Sagnac radial shearing interferometer is used for the correlation of optical fields and the Pockels cell is used to shift the phase of the interfering fields. The fringe contrast and fringe phase that jointly represent the complex spatial coherence function are measured by applying a 5-step phase shifting algorithm while recording the interferograms. The results of recording and reconstruction of an object illuminated using a light emitting diode, Luxeon Star LXHL-MMID, having spectral width at half maximum of about 35nm at wavelength 530nm, are presented. Due to the implementation of the phase shift by using a Pockels cell, the system is mechanics free and has the potential for automated fast measurement which can be applied for the investigation of dynamic situations. Moreover, the interference of the optical field even with low temporal coherent light is achieved without using any interference filter and a reliable 3-D object reconstruction can be achieved even in an outdoor environment due to the inherent stability provided by the common path interferometer. By changing the shearing parameter, we can tailor the range of the measured coherence function depending on object under test. This could enable one to use it as coherence zooming microscope.
- 3 May 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8776, 87760B
Digital holography for recording of incoherent-object hologram as complex spatial coherence function
We propose and demonstrate the recording of hologram of an incoherently illuminated object by using a Sagnac radial shearing interferometer, a Pockels cell and an 8 bit CCD camera. An approach based on statistical optics is used for understanding the concept of recording of an incoherent-object as complex spatial coherence function. The Sagnac radial shearing interferometer is used for the correlation of optical fields and the Pockels cell is used to shift the phase of the interfering fields. The fringe contrast and fringe phase that jointly represent the complex spatial coherence function are measured by applying a 5-step phase shifting algorithm while recording the interferograms. The results of recording and reconstruction of an object illuminated using a light emitting diode, Luxeon Star LXHL-MMID, having spectral width at half maximum of about 35nm at wavelength 530nm, are presented. Due to the implementation of the phase shift by using a Pockels cell, the system is mechanics free and has the potential for automated fast measurement which can be applied for the investigation of dynamic situations. Moreover, the interference of the optical field even with low temporal coherent light is achieved without using any interference filter and a reliable 3-D object reconstruction can be achieved even in an outdoor environment due to the inherent stability provided by the common path interferometer. By changing the shearing parameter, we can tailor the range of the measured coherence function depending on object under test. This could enable one to use it as coherence zooming microscope.
- Open Access
- 11 February 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (4) , 3990-3995
Recording of incoherent-object hologram as complex spatial coherence function using Sagnac radial shearing interferometer and a Pockels cell
The ideas of incoherent holography were conceived after the invention of coherent-light holography and their concepts seems indirectly related to it. In this work, we adopt an approach based on statistical optics to describe the process of recording of an incoherent-object hologram as a complex spatial coherence function. A Sagnac radial shearing interferometer is used for the correlation of optical fields and a Pockels cell is used to phase shift the interfering fields with the objective to quantify and to retrieve the spatial coherence function.
- 11 February 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (4) , 3990-3995
Open AccessRecording of incoherent-object hologram as complex spatial coherence function using Sagnac radial shearing interferometer and a Pockels cell
The ideas of incoherent holography were conceived after the invention of coherent-light holography and their concepts seems indirectly related to it. In this work, we adopt an approach based on statistical optics to describe the process of recording of an incoherent-object hologram as a complex spatial coherence function. A Sagnac radial shearing interferometer is used for the correlation of optical fields and a Pockels cell is used to phase shift the interfering fields with the objective to quantify and to retrieve the spatial coherence function.
- 13 August 2012
- Published by Optica Publishing Group in Optics Express
- Vol. 20 (18) , 19658-19669
Coherence holography by achromatic 3-D field correlation of generic thermal light with an imaging Sagnac shearing interferometer
We propose a new technique for achromatic 3-D field correlation that makes use of the characteristics of both axial and lateral magnifications of imaging through a common-path Sagnac shearing interferometer. With this technique, we experimentally demonstrate, for the first time to our knowledge, 3-D image reconstruction of coherence holography with generic thermal light. By virtue of the achromatic axial shearing implemented by the difference in axial magnifications in imaging, the technique enables coherence holography to reconstruct a 3-D object with an axial depth beyond the short coherence length of the thermal light.
- 13 August 2012
- Published by Optica Publishing Group in Optics Express
- Vol. 20 (18) , 19658-19669
Coherence holography by achromatic 3-D field correlation of generic thermal light with an imaging Sagnac shearing interferometer
We propose a new technique for achromatic 3-D field correlation that makes use of the characteristics of both axial and lateral magnifications of imaging through a common-path Sagnac shearing interferometer. With this technique, we experimentally demonstrate, for the first time to our knowledge, 3-D image reconstruction of coherence holography with generic thermal light. By virtue of the achromatic axial shearing implemented by the difference in axial magnifications in imaging, the technique enables coherence holography to reconstruct a 3-D object with an axial depth beyond the short coherence length of the thermal light.
- 31 July 2012
- Published by Optica Publishing Group in Optics Letters
- Vol. 37 (15) , 3282-3284
Single-shot full-field interferometric polarimeter with an integrated calibration scheme
A simple interferometric polarimeter with an integrated calibration scheme is proposed for accurate and fast mapping of the state of polarization (SOP). Conventional single-shot polarimeters that detect the amplitude and phase of orthogonally polarized field components by interferometry using Fourier fringe analysis suffers from errors caused by the imperfect reference beam and ambiguity in the spatial carrier frequency in the fringe pattern. In the proposed system, the integrated calibration scheme eliminates those error sources and enables accurate measurement of SOP without prior knowledge of the reference beam and the spatial carrier frequency.
- 31 July 2012
- Published by Optica Publishing Group in Optics Letters
- Vol. 37 (15) , 3282-3284
Single-shot full-field interferometric polarimeter with an integrated calibration scheme
A simple interferometric polarimeter with an integrated calibration scheme is proposed for accurate and fast mapping of the state of polarization (SOP). Conventional single-shot polarimeters that detect the amplitude and phase of orthogonally polarized field components by interferometry using Fourier fringe analysis suffers from errors caused by the imperfect reference beam and ambiguity in the spatial carrier frequency in the fringe pattern. In the proposed system, the integrated calibration scheme eliminates those error sources and enables accurate measurement of SOP without prior knowledge of the reference beam and the spatial carrier frequency.