CWColin L. Y. Wong

Colin L. Y. Wong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Colin L. Y. Wong has a total of 2 co-authors. Here are the top co-authors by number of shared publications:

  • Jeffrey Ramkellawan

    Golder Associates Ltd., Burnaby, British Columbia, Canada

    1 shared publication
  • Rachel Wyles

    Golder Associates Ltd , #500–4260 Still Creek Drive, Burnaby, British Columbia V5C 6C6, Canada

    1 shared publication

Latest Publications

  • Analysis of the number of flux chamber samples and study area size on the accuracy of emission rate measurements

    by Colin L.Y. Wong

    Monte Carlo simulations were conducted on a set of flux chamber measurements at a landfill to estimate the relationship between the number of flux chamber samples and study area size on the emission rate measurement accuracy. The spatial variability of flux was addressed in the study by utilizing an existing flux chamber measurement data set that is one of the most dense flux chamber sampling arrays published to date for a landfill. At a probability of 95%, the Monte Carlo simulations indicated that achieving an accuracy within 10% with the flux chamber method is highly unlikely. An accuracy within 20% was achieved for small areas of less than about 0.2 hectares using 220 flux chamber measurements, but achieving this level of accuracy for area emission sources, of similar or greater variability, that are larger than this is highly unlikely. An accuracy within 30% was achieved up to the Full Area of about 0.4 hectares if more than approximately 120 samples were obtained. Even for an accuracy within 50%, at least 40 flux chamber measurements were needed for the Full Area of about 0.4 hectares. Available methods of estimating the number of samples required were compared to the Monte Carlo simulation results. The Monte Carlo simulations indicate that, in general, more samples are required than determined from an existing statistical method, which is a function of the mean and standard deviation of the population. Specifying the number of samples based on a regulatory method results in very poor accuracy. A modification to the statistical method for estimating the number of samples, or for estimating an accuracy for a given probability and number of samples, is proposed. Implications: The flux chamber method is the most widely used method of measuring fugitive emission rates from area sources. However, extrapolation of a set of individual flux chamber samples to a larger area results in area flux measurement values of unknown accuracy. Quantification of the accuracy of the extrapolation of a set of flux chamber measurements would be beneficial for understanding the confidence that can be placed on the measurement results. Guidance as to the appropriate number of flux chamber measurements to achieve a desired level of accuracy would benefit flux chamber method practitioners.


  • Calibration of a fugitive emission rate measurement of an area source

    by Colin L. Y. Wong, Jeffrey Ramkellawan

    A major challenge to measuring fugitive emission rates from large area sources, such as landfills or tailings ponds, has been the establishment of the accuracy of such methods, or of a particular measurement. When such measurements are carried out, they are invariably associated with a relatively high degree of uncertainty. The Airborne Matter Mapping (AMM) method is a new method of measuring fugitive emission rates that can be applied to large area sources. The method was applied to the measurement of methane emissions from a landfill to assess the potential accuracy of the method, and the measurement process was calibrated to increase confidence in the measured value. First, a measured rate of methane from a gas cylinder was released from near the center of the landfill and the AMM method was applied to measure the methane flow rate across a measurement surface. Then, the AMM method was performed a second time along the same measurement surface without the intentional release of methane. The difference of the flow rates across the measurement surface were then compared with the measured rate of methane released from the gas cylinder. The relatively small difference of –5.7% between the flow rates, relative to the methane release rate from the gas cylinder, provides confidence in the accuracy of this AMM method measurement. An adjustment to the AMM method analysis was made such that the difference between the flow rates was negligible, which resulted in a calibrated measurement of the methane emission rate from the landfill of 0.87 g/sec.


  • Mapping concentrations of airborne matter to quantify the fugitive emissions discharge rate from a landfill

    by Colin Wong, Rachel Wyles

    The concentrations of methane in an emission plume from a demolition waste landfill located on Shxwhá:y Village land in Chilliwack, British Columbia, Canada were mapped in cross-section and the methane emission discharge rate was quantified using the airborne matter mapping (AMM) method. Application of the AMM method involved the measurement of wind velocity at the site, mounting a GPS and a fast, high-resolution concentration measurement instrument on a helicopter and then travelling through the plume along a measurement path, with each sampling run at different elevations. The data were contoured to produce a map of concentrations in cross-section through the plume on a measurement surface. The methane concentration data were also projected with the wind flow direction onto a flux plane and, when the wind speed was applied and an adjustment made for the background concentrations, the net mass flow rate of methane across the measurement surface and the mass emission discharge rate from the fugitive emission source were calculated to be 2.3 g/s. However, a portion of the plume was not mapped.