Aaron So
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Aaron So has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
Ting-Yim Lee
Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, ON, Canada
7 shared publicationsJiang Hsieh
Department of Molecular Imaging & Computed Tomography, GE Healthcare, Waukesha WI
6 shared publicationsAli Islam
Department of Radiology, St. Joseph's Healthcare London, London, ON, Canada; and
3 shared publicationsGerald Wisenberg
Department of Cardiology, London Health Sciences Centre, London, ON, Canada
3 shared publicationsPatrick Teefy
Department of Cardiology, London Health Sciences Centre, London, ON, Canada
3 shared publicationsYasuhiro Imai
CT Engineering, GE Healthcare, Waukesha, Wisconsin 53188
3 shared publications
Latest Publications
- Open Access
- 14 April 2022
- Published by MDPI AG in Tomography
- Vol. 8  (2) , 1129-1140
Effect of Cardiac Phase on Cardiac Output Index Derived from Dynamic CT Myocardial Perfusion Imaging
Purpose: The aortic time-enhancement curve obtained from dynamic CT myocardial perfusion imaging can be used to derive the cardiac output (CO) index based on the indicator dilution principle. The objective of this study was to investigate the effect of cardiac phase at which CT myocardial perfusion imaging is triggered on the CO index measurement with this approach. Methods: Electrocardiogram (ECG) gated myocardial perfusion imaging was performed on farm pigs with consecutive cardiac axial scans using a large-coverage CT scanner (Revolution, GE Healthcare) after intravenous contrast administration. Multiple sets of dynamic contrast-enhanced (DCE) cardiac images were reconstructed retrospectively from 30% to 80% R-R intervals with a 5% phase increment. The time-enhancement curve sampled from above the aortic orifice in each DCE image set was fitted with a modified gamma variate function (MGVF). The fitted curve was then normalized to the baseline data point unaffected by the streak artifact emanating from the contrast solution in the right heart chamber. The Stewart–Hamilton equation was used to calculate the CO index based on the integral of the fitted normalized aortic curve, and the results were compared among different cardiac phases. Results: The aortic time-enhancement curves sampled at different cardiac phases were different from each other, especially in the baseline portion of the curve where the effect of streak artifact was prominent. After properly normalizing and denoising with a MGVF, the integrals of the aortic curve were minimally different among cardiac phases (0.228 ± 0.001 Hounsfield Unit × second). The corresponding mean CO index was 4.031 ± 0.028 L/min. There were no statistical differences in either the integral of the aortic curve or CO index among different cardiac phases (p > 0.05 for all phases).
- 14 April 2022
- Published by MDPI AG in Tomography
- Vol. 8  (2) , 1129-1140
Open AccessEffect of Cardiac Phase on Cardiac Output Index Derived from Dynamic CT Myocardial Perfusion Imaging
Purpose: The aortic time-enhancement curve obtained from dynamic CT myocardial perfusion imaging can be used to derive the cardiac output (CO) index based on the indicator dilution principle. The objective of this study was to investigate the effect of cardiac phase at which CT myocardial perfusion imaging is triggered on the CO index measurement with this approach. Methods: Electrocardiogram (ECG) gated myocardial perfusion imaging was performed on farm pigs with consecutive cardiac axial scans using a large-coverage CT scanner (Revolution, GE Healthcare) after intravenous contrast administration. Multiple sets of dynamic contrast-enhanced (DCE) cardiac images were reconstructed retrospectively from 30% to 80% R-R intervals with a 5% phase increment. The time-enhancement curve sampled from above the aortic orifice in each DCE image set was fitted with a modified gamma variate function (MGVF). The fitted curve was then normalized to the baseline data point unaffected by the streak artifact emanating from the contrast solution in the right heart chamber. The Stewart–Hamilton equation was used to calculate the CO index based on the integral of the fitted normalized aortic curve, and the results were compared among different cardiac phases. Results: The aortic time-enhancement curves sampled at different cardiac phases were different from each other, especially in the baseline portion of the curve where the effect of streak artifact was prominent. After properly normalizing and denoising with a MGVF, the integrals of the aortic curve were minimally different among cardiac phases (0.228 ± 0.001 Hounsfield Unit × second). The corresponding mean CO index was 4.031 ± 0.028 L/min. There were no statistical differences in either the integral of the aortic curve or CO index among different cardiac phases (p > 0.05 for all phases).
- Open Access
- 3 June 2021
- Published by MDPI AG in Diagnostics
- Vol. 11  (6) , 1027
Thoracic Aortic Calcification and Pre-Clinical Hypertension by New 2017 ACC/AHA Hypertension Guidelines
The recently revised 2017 American College of Cardiology/American Heart Association (ACC/AHA) hypertension (HTN) guidelines employ a lower blood pressure threshold to define HTN, aiming for earlier prevention of HTN-related cardiovascular diseases (CVD). Thoracic aortic calcification (TAC), a new surrogate marker of aging and aortic medial layer degeneration, and different stages of HTN, according to the 2017 ACC/AHA HTN guidelines, remain unknown. We classified 3022 consecutive asymptomatic individuals enrolled into four HTN categories using the revised 2017 ACC/AHA guidelines: normal blood pressure (NBP), elevated blood pressure (EBP), and stage 1 (S1) and stage 2 (S2) HTN. The coronary artery calcification score and TAC metrics (total Agaston TAC score, total plaque volume (mm3), and mean density (Hounsfield units, HU)) were measured using multi-detector computed tomography. Compared to NBP, a graded and significant increase in the TAC metrics was observed starting from EBP and S1 and S2 HTN, using the new 2017 ACC/AHA guidelines (NBP as reference; all trends: p < 0.001). These differences remained consistent after being fully adjusted. Older age (>50 years), S1 and S2 HTN, prevalent diabetes, and chronic kidney disease (2) are all independently contributing factors to higher TAC risk using multivariate stepwise logistic regressions (all p ≤ 0.001). The optimal cutoff values of systolic blood pressure, diastolic blood pressure, and pulse pressure were 121, 74, and 45 mmHg, respectively, for the presence of TAC after excluding subjects with known CVD and ongoing HTN medication treatment. Our data showed that the presence of TAC starts at a stage of elevated blood pressure not categorized as HTN from the updated 2017 ACC/AHA hypertension guidelines.
- 3 June 2021
- Published by MDPI AG in Diagnostics
- Vol. 11  (6) , 1027
Open AccessThoracic Aortic Calcification and Pre-Clinical Hypertension by New 2017 ACC/AHA Hypertension Guidelines
The recently revised 2017 American College of Cardiology/American Heart Association (ACC/AHA) hypertension (HTN) guidelines employ a lower blood pressure threshold to define HTN, aiming for earlier prevention of HTN-related cardiovascular diseases (CVD). Thoracic aortic calcification (TAC), a new surrogate marker of aging and aortic medial layer degeneration, and different stages of HTN, according to the 2017 ACC/AHA HTN guidelines, remain unknown. We classified 3022 consecutive asymptomatic individuals enrolled into four HTN categories using the revised 2017 ACC/AHA guidelines: normal blood pressure (NBP), elevated blood pressure (EBP), and stage 1 (S1) and stage 2 (S2) HTN. The coronary artery calcification score and TAC metrics (total Agaston TAC score, total plaque volume (mm3), and mean density (Hounsfield units, HU)) were measured using multi-detector computed tomography. Compared to NBP, a graded and significant increase in the TAC metrics was observed starting from EBP and S1 and S2 HTN, using the new 2017 ACC/AHA guidelines (NBP as reference; all trends: p < 0.001). These differences remained consistent after being fully adjusted. Older age (>50 years), S1 and S2 HTN, prevalent diabetes, and chronic kidney disease (2) are all independently contributing factors to higher TAC risk using multivariate stepwise logistic regressions (all p ≤ 0.001). The optimal cutoff values of systolic blood pressure, diastolic blood pressure, and pulse pressure were 121, 74, and 45 mmHg, respectively, for the presence of TAC after excluding subjects with known CVD and ongoing HTN medication treatment. Our data showed that the presence of TAC starts at a stage of elevated blood pressure not categorized as HTN from the updated 2017 ACC/AHA hypertension guidelines.
- Top Cited PapersOpen Access
- 1 January 2021
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 22  (1) , 86-96
Spectral Computed Tomography: Fundamental Principles and Recent Developments
So A, et al. Korean J Radiol. 2021 Jan;22(1):86-96. https://doi.org/10.3348/kjr.2020.0144
- 1 January 2021
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 22  (1) , 86-96
Top Cited PapersOpen AccessSpectral Computed Tomography: Fundamental Principles and Recent Developments
So A, et al. Korean J Radiol. 2021 Jan;22(1):86-96. https://doi.org/10.3348/kjr.2020.0144
- Open Access
- 1 September 2019
- Published by MDPI AG in Tomography
- Vol. 5  (3) , 300-307
Cubic-Spline Interpolation for Sparse-View CT Image Reconstruction With Filtered Backprojection in Dynamic Myocardial Perfusion Imaging
We investigated a projection interpolation method for reconstructing dynamic contrast-enhanced (DCE) heart images from undersampled x-ray projections with filtered backprojecton (FBP). This method may facilitate the application of sparse-view dynamic acquisition for ultralow-dose quantitative computed tomography (CT) myocardial perfusion (MP) imaging. We conducted CT perfusion studies on 5 pigs with a standard full-view acquisition protocol (984 projections). We reconstructed DCE heart images with FBP from all and a quarter of the measured projections evenly distributed over 360°. We interpolated the sparse-view (quarter) projections to a full-view setting using a cubic-spline interpolation method before applying FBP to reconstruct the DCE heart images (synthesized full-view). To generate MP maps, we used 3 sets of DCE heart images, and compared mean MP values and biases among the 3 protocols. Compared with synthesized full-view DCE images, sparse-view DCE images were more affected by streak artifacts arising from projection undersampling. Relative to the full-view protocol, mean bias in MP measurement associated with the sparse-view protocol was 10.0 mL/min/100 g (95%CI: −8.9 to 28.9), which was >3 times higher than that associated with the synthesized full-view protocol (3.3 mL/min/100 g, 95% CI: −6.7 to 13.2). The cubic-spline-view interpolation method improved MP measurement from DCE heart images reconstructed from only a quarter of the full projection set. This method can be used with the industry-standard FBP algorithm to reconstruct DCE images of the heart, and it can reduce the radiation dose of a whole-heart quantitative CT MP study to <2 mSv (at 8-cm coverage).
- 1 September 2019
- Published by MDPI AG in Tomography
- Vol. 5  (3) , 300-307
Open AccessCubic-Spline Interpolation for Sparse-View CT Image Reconstruction With Filtered Backprojection in Dynamic Myocardial Perfusion Imaging
We investigated a projection interpolation method for reconstructing dynamic contrast-enhanced (DCE) heart images from undersampled x-ray projections with filtered backprojecton (FBP). This method may facilitate the application of sparse-view dynamic acquisition for ultralow-dose quantitative computed tomography (CT) myocardial perfusion (MP) imaging. We conducted CT perfusion studies on 5 pigs with a standard full-view acquisition protocol (984 projections). We reconstructed DCE heart images with FBP from all and a quarter of the measured projections evenly distributed over 360°. We interpolated the sparse-view (quarter) projections to a full-view setting using a cubic-spline interpolation method before applying FBP to reconstruct the DCE heart images (synthesized full-view). To generate MP maps, we used 3 sets of DCE heart images, and compared mean MP values and biases among the 3 protocols. Compared with synthesized full-view DCE images, sparse-view DCE images were more affected by streak artifacts arising from projection undersampling. Relative to the full-view protocol, mean bias in MP measurement associated with the sparse-view protocol was 10.0 mL/min/100 g (95%CI: −8.9 to 28.9), which was >3 times higher than that associated with the synthesized full-view protocol (3.3 mL/min/100 g, 95% CI: −6.7 to 13.2). The cubic-spline-view interpolation method improved MP measurement from DCE heart images reconstructed from only a quarter of the full projection set. This method can be used with the industry-standard FBP algorithm to reconstruct DCE images of the heart, and it can reduce the radiation dose of a whole-heart quantitative CT MP study to <2 mSv (at 8-cm coverage).
- 26 April 2018
- Published by Elsevier in International Journal of Cardiology
- Vol. 266, 15-23
Functional CT assessment of extravascular contrast distribution volume and myocardial perfusion in acute myocardial infarction
- 26 April 2018
- Published by Elsevier in International Journal of Cardiology
- Vol. 266, 15-23
Functional CT assessment of extravascular contrast distribution volume and myocardial perfusion in acute myocardial infarction
- 1 March 2018
- Published by Elsevier in International Journal of Cardiology
- Vol. 254, 272-281
Ultra-low dose quantitative CT myocardial perfusion imaging with sparse-view dynamic acquisition and image reconstruction: A feasibility study
- 1 March 2018
- Published by Elsevier in International Journal of Cardiology
- Vol. 254, 272-281
Ultra-low dose quantitative CT myocardial perfusion imaging with sparse-view dynamic acquisition and image reconstruction: A feasibility study
- Open Access
- 1 December 2017
- Published by MDPI AG in Tomography
- Vol. 3  (4) , 175-179
Ultra-Low-Dose Sparse-View Quantitative CT Liver Perfusion Imaging
Radiation dose of computed tomography liver perfusion imaging can be reduced by collecting fewer x-ray projections in each gantry rotation, but the resulting aliasing artifacts could affect the hepatic perfusion measurement. We investigated the effect of projection undersampling on the assessment of hepatic arterial blood flow (HABF) in hepatocellular carcinoma (HCC) when dynamic contrast-enhanced (DCE) liver images were reconstructed with filtered backprojection (FBP) and compressed sensing (CS). DCE liver images of a patient with HCC acquired with a 64-row CT scanner were reconstructed from all the measured projections (984-view) with the standard FBP and from one-third (328-view) and one-fourth (246-view) of all available projections with FBP and CS. Each of the 5 sets of DCE liver images was analyzed with a model-based deconvolution algorithm from which HABF maps were generated and compared. Mean HABF in the tumor and normal tissue measured by the 328-view CS and FBP protocols was within 5% differences from that assessed by the reference full-view FBP protocol. In addition, the tumor size measured by using the 328-view CS and FBP average images was identical to that determined by using the full-view FBP average image. By contrast, both the 246-view CS and FBP protocols exhibited larger differences (>20%) in anatomical and functional assessments compared with the full-view FBP protocol. The preliminary results suggested that computed tomography perfusion imaging in HCC could be performed with 3 times less projection measurement than the current full-view protocol (67% reduction in radiation dose) when either FBP or CS was used for image reconstruction.
- 1 December 2017
- Published by MDPI AG in Tomography
- Vol. 3  (4) , 175-179
Open AccessUltra-Low-Dose Sparse-View Quantitative CT Liver Perfusion Imaging
Radiation dose of computed tomography liver perfusion imaging can be reduced by collecting fewer x-ray projections in each gantry rotation, but the resulting aliasing artifacts could affect the hepatic perfusion measurement. We investigated the effect of projection undersampling on the assessment of hepatic arterial blood flow (HABF) in hepatocellular carcinoma (HCC) when dynamic contrast-enhanced (DCE) liver images were reconstructed with filtered backprojection (FBP) and compressed sensing (CS). DCE liver images of a patient with HCC acquired with a 64-row CT scanner were reconstructed from all the measured projections (984-view) with the standard FBP and from one-third (328-view) and one-fourth (246-view) of all available projections with FBP and CS. Each of the 5 sets of DCE liver images was analyzed with a model-based deconvolution algorithm from which HABF maps were generated and compared. Mean HABF in the tumor and normal tissue measured by the 328-view CS and FBP protocols was within 5% differences from that assessed by the reference full-view FBP protocol. In addition, the tumor size measured by using the 328-view CS and FBP average images was identical to that determined by using the full-view FBP average image. By contrast, both the 246-view CS and FBP protocols exhibited larger differences (>20%) in anatomical and functional assessments compared with the full-view FBP protocol. The preliminary results suggested that computed tomography perfusion imaging in HCC could be performed with 3 times less projection measurement than the current full-view protocol (67% reduction in radiation dose) when either FBP or CS was used for image reconstruction.
- 28 July 2016
- Published by Wiley in Medical Physics
- Vol. 43  (8Part1) , 4821-4832
Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging
Purpose: The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative reconstruction (ASiR-V) to correct for image noise arising from low tube voltage potential/tube current dynamic scanning, and image reconstruction algorithms to tackle beam-hardening, cone-beam, and partial-scan effects. Methods: Phantom studies were performed to investigate the effectiveness of image noise and artifact reduction with a GE Healthcare Revolution CT system for three acquisition protocols used in quantitative CT MP imaging: 100, 120, and 140 kVp/25 mAs. The heart chambers of an anthropomorphic chest phantom were filled with iodinated contrast solution at different concentrations (contrast levels) to simulate the circulation of contrast through the heart in quantitative CT MP imaging. To evaluate beam-hardening correction, the phantom was scanned at each contrast level to measure the changes in CT number (in Hounsfield unit or HU) in the water-filled region surrounding the heart chambers with respect to baseline. To evaluate cone-beam artifact correction, differences in mean water HU between the central and peripheral slices were compared. Partial-scan artifact correction was evaluated from the fluctuation of mean water HU in successive partial scans. To evaluate image noise reduction, a small hollow region adjacent to the heart chambers was filled with diluted contrast, and contrast-to-noise ratio in the region before and after noise correction with ASiR-V was compared. The quality of MP maps acquired with the CT system was also evaluated in porcine CT MP studies. Myocardial infarct was induced in a farm pig from a transient occlusion of the distal left anterior descending (LAD) artery with a catheter-based interventional procedure. MP maps were generated from the dynamic contrast-enhanced (DCE) heart images taken at baseline and three weeks after the ischemic insult. Results: Their results showed that the phantom and animal images acquired with the CT platform were minimally affected by image noise and artifacts. For the beam-hardening phantom study, changes in water HU in the wall surrounding the heart chambers greatly reduced from >±30 to ≤ ± 5 HU at all kVp settings except one region at 100 kVp (7 HU). For the cone-beam phantom study, differences in mean water HU from the central slice were less than 5 HU at two peripheral slices with each 4 cm away from the central slice. These findings were reproducible in the pig DCE images at two peripheral slices that were 6 cm away from the central slice. For the partial-scan phantom study, standard deviations of the mean water HU in 10 successive partial scans were less than 5 HU at the central slice. Similar observations were made in the pig DCE images at two peripheral slices with each 6 cm away from the central slice. For the image noise phantom study, CNRs in the ASiR-V images were statistically higher (p < 0.05) than the non-ASiR-V images at all kVp settings. MP maps generated from the porcine DCE images were in excellent quality, with the ischemia in the LAD territory clearly seen in the three orthogonal views. Conclusions: The study demonstrates that this CT system can provide accurate and reproducible CT numbers during cardiac gated acquisitions across a wide axial field of view. This CT number fidelity will enable this imaging tool to assess contrast enhancement, potentially providing valuable added information beyond anatomic evaluation of coronary stenoses. Furthermore, their results collectively suggested that the 100 kVp/25 mAs protocol run on this CT system provides sufficient image accuracy at a low radiation dose (<3 mSv) for whole-heart quantitative CT MP imaging.
- 28 July 2016
- Published by Wiley in Medical Physics
- Vol. 43  (8Part1) , 4821-4832
Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging
Purpose: The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative reconstruction (ASiR-V) to correct for image noise arising from low tube voltage potential/tube current dynamic scanning, and image reconstruction algorithms to tackle beam-hardening, cone-beam, and partial-scan effects. Methods: Phantom studies were performed to investigate the effectiveness of image noise and artifact reduction with a GE Healthcare Revolution CT system for three acquisition protocols used in quantitative CT MP imaging: 100, 120, and 140 kVp/25 mAs. The heart chambers of an anthropomorphic chest phantom were filled with iodinated contrast solution at different concentrations (contrast levels) to simulate the circulation of contrast through the heart in quantitative CT MP imaging. To evaluate beam-hardening correction, the phantom was scanned at each contrast level to measure the changes in CT number (in Hounsfield unit or HU) in the water-filled region surrounding the heart chambers with respect to baseline. To evaluate cone-beam artifact correction, differences in mean water HU between the central and peripheral slices were compared. Partial-scan artifact correction was evaluated from the fluctuation of mean water HU in successive partial scans. To evaluate image noise reduction, a small hollow region adjacent to the heart chambers was filled with diluted contrast, and contrast-to-noise ratio in the region before and after noise correction with ASiR-V was compared. The quality of MP maps acquired with the CT system was also evaluated in porcine CT MP studies. Myocardial infarct was induced in a farm pig from a transient occlusion of the distal left anterior descending (LAD) artery with a catheter-based interventional procedure. MP maps were generated from the dynamic contrast-enhanced (DCE) heart images taken at baseline and three weeks after the ischemic insult. Results: Their results showed that the phantom and animal images acquired with the CT platform were minimally affected by image noise and artifacts. For the beam-hardening phantom study, changes in water HU in the wall surrounding the heart chambers greatly reduced from >±30 to ≤ ± 5 HU at all kVp settings except one region at 100 kVp (7 HU). For the cone-beam phantom study, differences in mean water HU from the central slice were less than 5 HU at two peripheral slices with each 4 cm away from the central slice. These findings were reproducible in the pig DCE images at two peripheral slices that were 6 cm away from the central slice. For the partial-scan phantom study, standard deviations of the mean water HU in 10 successive partial scans were less than 5 HU at the central slice. Similar observations were made in the pig DCE images at two peripheral slices with each 6 cm away from the central slice. For the image noise phantom study, CNRs in the ASiR-V images were statistically higher (p < 0.05) than the non-ASiR-V images at all kVp settings. MP maps generated from the porcine DCE images were in excellent quality, with the ischemia in the LAD territory clearly seen in the three orthogonal views. Conclusions: The study demonstrates that this CT system can provide accurate and reproducible CT numbers during cardiac gated acquisitions across a wide axial field of view. This CT number fidelity will enable this imaging tool to assess contrast enhancement, potentially providing valuable added information beyond anatomic evaluation of coronary stenoses. Furthermore, their results collectively suggested that the 100 kVp/25 mAs protocol run on this CT system provides sufficient image accuracy at a low radiation dose (<3 mSv) for whole-heart quantitative CT MP imaging.