Catarina Nunes Matias
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Catarina Nunes Matias has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Analiza Monica Silva
Exercise and Health Laboratory, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, Cruz-Quebrada, Portugal
4 shared publications - Diana Aguiar Santos
Exercise and Health Laboratory, CIPER, Faculdade de Motricidade Humana, Universidade de Lisboa, Portugal
4 shared publications - Luis Bettencourt Sardinha
Exercise and Health Laboratory, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, 1499-002 Lisbon, Portugal
4 shared publications - Cristina Paula Monteiro
Interdisciplinary Center for the Study of Human Performance (CIPER), Faculdade de Motricidade Humana, Universidade de Lisboa, 1495-761 Cruz-Quebrada, Portugal
2 shared publications - Maria José Laires
A Physiology and Biochemistry of Exercise Laboratory, Interdisciplinary Center for Human Performance Study (CIPER), Faculdade de Motricidade Humana, Universidade Lisboa, Estrada da Costa, 1499-002 Cruz-Quebrada, Portugal
2 shared publications David A Fields
Department of Pediatrics - Children’s Hospital Foundation, University of Oklahoma Health Science Center, Oklahoma, USA
1 shared publication
Latest Publications
- 1 January 2018
- Published by Coimbra University Press in Annals of Research in Sport and Physical Activity
- No. ex2018,p. 201-202
Training influences the acute immune response to a maximal swimming test
- 1 January 2018
- Published by Coimbra University Press in Annals of Research in Sport and Physical Activity
- No. ex2018,p. 201-202
Training influences the acute immune response to a maximal swimming test
- 14 June 2012
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 30 (12) , 1225-1233
Is bioelectrical impedance spectroscopy accurate in estimating changes in fat-free mass in judo athletes?
Bioelectrical impedance spectroscopy (BIS) provides an affordable and practical assessment of fat-free mass (FFM). However, little information is available on the assessment of changes in fat-free mass in top-level athletes using BIS. The aim of this study was to examine the accuracy of BIS in tracking changes in fat-free mass of elite male judo athletes from a period of weight stability to just before competition, using the four-compartment model (4C model) as reference method. In total, 27 elite male judo athletes (age 22.2 ± 2.8 years) were evaluated. Measures of body volume assessed by air displacement plethysmography, bone mineral content by dual-energy X-ray absorptiometry, and total-body water assessed with deuterium dilution were used in a 4C model. Fat-free mass was also assessed by BIS (FFMBIS). Changes in FFMBIS were not significantly different from measured by the reference method (P = 0.000). Furthermore, the r 2 was 0.62 and the standard error of the estimate was 1.03 kg. The limits of agreement ranged from −3.36 to 2.59 kg with no bias observed. These findings demonstrate the viability of BIS as a valid tool for tracking fat-free mass in elite male judo athletes. However, based on the wide limits of agreement observed, BIS is less valid at an individual level for tracking fat-free mass in these athletes.
- 14 June 2012
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 30 (12) , 1225-1233
Is bioelectrical impedance spectroscopy accurate in estimating changes in fat-free mass in judo athletes?
Bioelectrical impedance spectroscopy (BIS) provides an affordable and practical assessment of fat-free mass (FFM). However, little information is available on the assessment of changes in fat-free mass in top-level athletes using BIS. The aim of this study was to examine the accuracy of BIS in tracking changes in fat-free mass of elite male judo athletes from a period of weight stability to just before competition, using the four-compartment model (4C model) as reference method. In total, 27 elite male judo athletes (age 22.2 ± 2.8 years) were evaluated. Measures of body volume assessed by air displacement plethysmography, bone mineral content by dual-energy X-ray absorptiometry, and total-body water assessed with deuterium dilution were used in a 4C model. Fat-free mass was also assessed by BIS (FFMBIS). Changes in FFMBIS were not significantly different from measured by the reference method (P = 0.000). Furthermore, the r 2 was 0.62 and the standard error of the estimate was 1.03 kg. The limits of agreement ranged from −3.36 to 2.59 kg with no bias observed. These findings demonstrate the viability of BIS as a valid tool for tracking fat-free mass in elite male judo athletes. However, based on the wide limits of agreement observed, BIS is less valid at an individual level for tracking fat-free mass in these athletes.
- Open Access
- 4 August 2011
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Cineantropometria & Desempenho Humano
- Vol. 13 (4) , 243-249
Fatores Determinantes na aptidão cardiorrespiratória em Portugueses de diferentes etnias. DOI: 10.5007/1980-0037.2011v13n4p243
Cardiorespiratory fitness is an important health indicator in young people. The aim of this study was to investigate the effects of age, gender, body adiposity, and ethnicity on cardiorespiratory fitness in a sample of Portuguese adolescents. The sample consisted of 266 adolescents aged 12-18 years [112 boys (80 Caucasians and 32 African-Portuguese, AP) and 154 girls (109 Caucasians and 45 AP)]. Percent body fat was estimated with a hand-to-hand bioelectrical impedance device (BF300, OMROM). Cardiorespiratory fitness was assessed by a shuttle run test (Fitnessgram battery). Multiple regression models were used for statistical analysis. The results showed that girls presented lower maximal oxygen consumption and higher percent body fat than boys. Cardiorespiratory fitness was lower in Caucasian than in AP girls. Multiple regression analysis showed that percent body fat, age and the interaction of age with being Caucasian and age with female gender were significant determinants that were negatively associated with cardiorespiratory fitness. The results suggest that maximal oxygen consumption is lower in adolescents with higher adiposity and in older adolescents. The findings highlight the importance of promoting physical fitness in schools across ages, especially in older adolescents, adjusting for determinant factors such as gender and ethnicity
- 4 August 2011
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Cineantropometria & Desempenho Humano
- Vol. 13 (4) , 243-249
Open AccessFatores Determinantes na aptidão cardiorrespiratória em Portugueses de diferentes etnias. DOI: 10.5007/1980-0037.2011v13n4p243
Cardiorespiratory fitness is an important health indicator in young people. The aim of this study was to investigate the effects of age, gender, body adiposity, and ethnicity on cardiorespiratory fitness in a sample of Portuguese adolescents. The sample consisted of 266 adolescents aged 12-18 years [112 boys (80 Caucasians and 32 African-Portuguese, AP) and 154 girls (109 Caucasians and 45 AP)]. Percent body fat was estimated with a hand-to-hand bioelectrical impedance device (BF300, OMROM). Cardiorespiratory fitness was assessed by a shuttle run test (Fitnessgram battery). Multiple regression models were used for statistical analysis. The results showed that girls presented lower maximal oxygen consumption and higher percent body fat than boys. Cardiorespiratory fitness was lower in Caucasian than in AP girls. Multiple regression analysis showed that percent body fat, age and the interaction of age with being Caucasian and age with female gender were significant determinants that were negatively associated with cardiorespiratory fitness. The results suggest that maximal oxygen consumption is lower in adolescents with higher adiposity and in older adolescents. The findings highlight the importance of promoting physical fitness in schools across ages, especially in older adolescents, adjusting for determinant factors such as gender and ethnicity
- Open Access
- 22 March 2010
- Published by Springer Nature in Nutrition & Metabolism
- Vol. 7 (1) , 22
Accuracy of DXA in estimating body composition changes in elite athletes using a four compartment model as the reference method
Background: Dual-energy x-ray absorptiometry (DXA) provides an affordable and practical assessment of multiple whole body and regional body composition. However, little information is available on the assessment of changes in body composition in top-level athletes using DXA. The present study aimed to assess the accuracy of DXA in tracking body composition changes (relative fat mass [%FM], absolute fat mass [FM], and fat-free mass [FFM]) of elite male judo athletes from a period of weight stability to prior to a competition, compared to a four compartment model (4C model), as the criterion method.Methods: A total of 27 elite male judo athletes (age, 22.2 ± 2.8 yrs) athletes were evaluated. Measures of body volume by air displacement plethysmography, bone mineral content assessed by DXA, and total-body water assessed by deuterium dilution were used in a 4C model. Statistical analyses included examination of the coefficient of determinant (r2), standard error of estimation (SEE), slope, intercept, and agreement between models.Results: At a group level analysis, changes in %FM, FM, and FFM estimates by DXA were not significantly different from those by the 4C model. Though the regression between DXA and the 4C model did not differ from the line of identity DXA %FM, FM, and FFM changes only explained 29%, 36%, and 38% of the 4C reference values, respectively. Individual results showed that the 95% limits of agreement were -3.7 to 5.3 for %FM, -2.6 to 3.7 for FM, and -3.7 to 2.7 for FFM. The relation between the difference and the mean of the methods indicated a significant trend for %FM and FM changes with DXA overestimating at the lower ends and underestimating at the upper ends of FM changes.Conclusions: Our data indicate that both at group and individual levels DXA did not present an expected accuracy in tracking changes in adiposity in elite male judo athletes.
- 22 March 2010
- Published by Springer Nature in Nutrition & Metabolism
- Vol. 7 (1) , 22
Open AccessAccuracy of DXA in estimating body composition changes in elite athletes using a four compartment model as the reference method
Background: Dual-energy x-ray absorptiometry (DXA) provides an affordable and practical assessment of multiple whole body and regional body composition. However, little information is available on the assessment of changes in body composition in top-level athletes using DXA. The present study aimed to assess the accuracy of DXA in tracking body composition changes (relative fat mass [%FM], absolute fat mass [FM], and fat-free mass [FFM]) of elite male judo athletes from a period of weight stability to prior to a competition, compared to a four compartment model (4C model), as the criterion method.Methods: A total of 27 elite male judo athletes (age, 22.2 ± 2.8 yrs) athletes were evaluated. Measures of body volume by air displacement plethysmography, bone mineral content assessed by DXA, and total-body water assessed by deuterium dilution were used in a 4C model. Statistical analyses included examination of the coefficient of determinant (r2), standard error of estimation (SEE), slope, intercept, and agreement between models.Results: At a group level analysis, changes in %FM, FM, and FFM estimates by DXA were not significantly different from those by the 4C model. Though the regression between DXA and the 4C model did not differ from the line of identity DXA %FM, FM, and FFM changes only explained 29%, 36%, and 38% of the 4C reference values, respectively. Individual results showed that the 95% limits of agreement were -3.7 to 5.3 for %FM, -2.6 to 3.7 for FM, and -3.7 to 2.7 for FFM. The relation between the difference and the mean of the methods indicated a significant trend for %FM and FM changes with DXA overestimating at the lower ends and underestimating at the upper ends of FM changes.Conclusions: Our data indicate that both at group and individual levels DXA did not present an expected accuracy in tracking changes in adiposity in elite male judo athletes.