  • Hydrologic Performance of Bioretention Storm-Water Control Measures

    by Allen P. Davis, Robert G. Traver, William F. Hunt, Ryan Lee, Robert A. Brown, Jennifer M. Olszewski

    The transportation and urban infrastructure relies heavily on impervious surfaces. Unmitigated rainfall runoff from impervious surfaces can lead to a myriad of environmental problems in downgradient areas. To address this issue, novel stormwater control measures (SCMs) are being emphasized and implemented widely to mitigate some of the impacts of impervious surface. Bioretention is a soil/media-based SCM that is often used for this purpose, but current design practices are highly empirical. This study compiles work from three research sites in three states to provide some fundamental underpinnings to bioretention design. Although all sites demonstrate different levels of performance, water volumetric performance trends are common to all. These trends are based on the available storage in the bioretention cell, termed herein as the Bioretention Abstraction Volume (BAV). The BAV is directly related to available media porosity and storage in the surface bowl. A finite capacity to completely store all runoff from smaller events is defined by the BAV. Normalization for this storage provides prediction for volumetric performance. Recommendations for bioretention design are provided.


  • Evaluating Media Depth, Surface Storage Volume, and Presence of an Internal Water Storage Zone on Four Sets of Bioretention Cells in North Carolina

    by Robert A. Brown, William F. Hunt

    Bioretention is becoming a widely used stormwater control measure (SCM) to achieve stringent stormwater regulations. This field study describes research performed on two sites in eastern North Carolina, where monitoring occurred for just over two years. At each site, there were two hydrologically separate bioretention cells. After the first year of research, a design specification was altered for both cells at each study site. Analysis for all cells included: (1) an annual runoff balance and (2) a calculation of concentration and pollutant load reductions for nitrogen species, phosphorus species, and total suspended solids. The bioretention cells in Rocky Mount, NC, were designed with an internal water storage (IWS) zone. The underdrain outlet was 0.3 and 0.6 m from the surface of the media in the first and second year, respectively. This feature had a major impact on runoff volume reduction. Each cell had a different underlying soil type; one was sand and the other sandy clay loam. Out of 151 monitored rainfall events over two years, outflow only occurred in 6 and 21 events, respectively. More drainage occurred in the cell with the tighter underlying soil and when the IWS zone was shallower due to less storage volume availability. The bioretention cells in Nashville, NC, were conventionally drained. They had varying media depths (0.6-m versus 0.9-m). During construction, they were severely undersized and clogged with fine sediment. After one year, the clogging layer was removed, which nearly doubled the surface storage volume and increased the infiltration rate by almost a factor of ten. The bioretention cells pre-repair were treating nearly 65 percent of annual runoff. After the repair, an additional 25 percent of annual runoff was treated. This improved the water quality treatment, reduced peak outflow rates, and reduced the duration of high outflow rates. Both sites demonstrated the impact that changing one of the design parameters has on the overall performance. For incorporating an IWS zone, the hydrologic and water quality performance appear dependent upon underlying soils and IWS zone depth. Results from the other site highlighted the importance of properly constructing and maintaining bioretention cells.


  • Impacts of Media Depth on Effluent Water Quality and Hydrologic Performance of Undersized Bioretention Cells

    by Robert A. Brown, William F. Hunt

    Fill media and excavation volume are the main costs in constructing bioretention cells, but the importance and impact of media depth in these systems is relatively unknown. Two sets of loamy-sand-filled bioretention cells of two media depths (0.6 m and 0.9 m), located in Nashville, North Carolina, were monitored from March 2008 to March 2009 to examine the impact of media depth on their performance with respect to hydrology and water quality. Construction and design errors resulted in the surface storage volume being undersized for the design event (2.5 cm). The actual surface storage volume was only 28% and 35% of the design volume for the 0.6-m and 0.9-m media depth cells, respectively. Overflow (bypass) occurred at least three times more frequently than intended. The exfiltration volume was much higher in the deeper media cells, presumably because of greater storage volume in the media and more exposure to side walls. Evapotranspiration (ET) plus exfiltration accounted for 42% of the inflow runoff in t...


  • Impacts of Construction Activity on Bioretention Performance

    by Robert A. Brown, William F. Hunt

    Bioretention cells are incorporated as part of low impact development (LID) because of their ability to release influent runoff as exfiltration to the soil or evapotranspiration to the atmosphere. However, little care is taken as to the techniques used to excavate bioretention cells, and there is little concern as to the soil-moisture condition during excavation. Certain excavation techniques and soil-moisture conditions create higher levels of compaction which consequently reduce infiltration capacity. Two excavation techniques, the conventional “scoop” method which purposefully smears the underlying soil surface and the “rake” method which uses the teeth of an excavator’s bucket to scarify the underlying soil surface, were tested. Field tests were conducted on three soil types (sand, loamy sand, and clay) under a variety of antecedent soil-moisture conditions. Multiple hydraulic conductivity, surface infiltration, and soil compaction measurements were taken for each excavated condition. In all cases, th...


  • Impact of Maintenance and (Im)Properly Sizing Bioretention on Hydrologic and Water Quality Performance

    by Robert A. Brown, William F. Hunt

    Routine maintenance and proper construction oversight both need to occur during and after bioretention cell construction, in order to ensure proper functionality. Two sets of bioretention cells of varying media depths (0.6-m and 0.9-m) will have been monitored for two, 12-month periods, in Nashville, NC. They treat runoff from an impervious asphalt parking lot. These bioretention cells are unique in that during the first monitoring period, the bioretention cells were (1) clogged with sediment from construction and (2) were severely undersized. Complete drawdown of the surface storage took 48 hours or more, as compared to the recommended 12 hours. Initially, the surface storage volumes for the 0.6-m and 0.9-m media depth cells were only 28 percent and 35 percent of the design storage volume, respectively. The design event for the bioretention cells at this site was 2.5-cm, but the system was overwhelmed frequently and overflow occurred for events as small as 0.9 cm. Overflow was occurring three times more frequently than intended. After one year of monitoring, a contractor removed the fines layer that was present in the top 7.6-cm. Through removal of this layer and expanding the surface area, the surface storage volume was increased by 89 percent for both cells. With the increase in surface storage volume, more runoff was treated, and fewer events had overflow. The smallest event with overflow was 1.9 cm, and some events up to 2.8 cm were fully captured in the bowl. Overflow volume was reduced to approximately one-third of the volume during the first monitoring period. Moreover, removal of the fines layer increased the surface drawdown rate by a factor exceeding 10. Pollutant load reductions increased for nitrogen species and total suspended solids because more runoff was treated. The results of this study highlight the reduced performance associated with improperly constructed and maintained bioretention cells. Even a small construction error in setting the base elevation for the bottom of the bowl or the emergency overflow structure can drastically reduce the bowl storage volume.


  • Impact of Maintenance and (Im)Properly Sizing Bioretention on Hydrologic and Water Quality Performance

    by Robert A. Brown, William F. Hunt

    Bioretention is one of the most common low impact development (LID) stormwater practices. Two sets of bioretention cells of varying media depths (0.6-m and 0.9-m) will have been monitored for two, 12-month periods, in Nashville, NC. They treat runoff from an impervious asphalt parking lot. During the first monitoring period, the bioretention cells were clogged with sediment from construction and were severely undersized. Complete drawdown of the surface storage took approximately 48 hours or more, as compared to the recommended 12 hours. Initially, the surface storage volumes for the 0.6-m and 0.9-m media depth cells were 36 percent and 46 percent of the design storage volume, respectively. The bioretention cells were designed to treat the 2.5-cm event, but the system became overwhelmed and overflow occurred for events as small as 0.8 cm. Overflow was occurring three times more frequently than intended. In March 2009, a contractor removed the fines layer that was present in the top 7.6-cm. Through removal of this layer and expanding the surface area, the surface storage volume was increased by 89 percent for both cells. With the increase in surface storage volume, more runoff has been treated, and the system was overwhelmed less frequently. The volume of overflow has been reduced to approximately one-third of the volume, as compared to the first monitoring period. Moreover, removing the fines layer has increased surface drawdown rate by at least 10 times. This site was also monitored for water quality. Nitrogen and phosphorus species and total suspended solids were measured. The results of this study show the importance of properly constructing and maintaining bioretention cells. Undersizing a bioretention cell as a result of a small construction error in setting the base elevation for the bottom of the bowl or the emergency overflow structure will result in a reduction in performance.


  • Comparison of Low Impact Development Treatment, Traditional Stormwater Treatment, and No Stormwater Treatment for Commercial Shopping Centers in North Carolina

    by Robert A. Brown, Daniel E. Line, William F. Hunt, William G. Lord

    Low impact development (LID) stormwater practices are becoming more popular because of their ability to improve water quality and recharge groundwater. New regulations require water quality treatment of stormwater runoff in addition to reducing peak flows, especially in nutrient sensitive watersheds. Previously, the main focus of traditional stormwater practices had been on mitigating flooding and reducing peak flows; whereas, newer LID practices improve water quality and attempt to restore a site's natural or pre-developed hydrology. This is accomplished by promoting more evapotranspiration and infiltration. Three commercial shopping centers have been monitored from April 2008 to September 2009 to measure the performance of using LID stormwater treatment, traditional stormwater treatment, or no stormwater treatment. All three sites were monitored for water quality and hydrology, and they were located within 70-km of each other. The site with no stormwater treatment and the site with traditional stormwater treatment were located in Raleigh, NC, and the site with LID treatment was located in Nashville, NC. Since the sites did not receive the same precipitation depths for each storm, the hydrology data were normalized per area treated. The LID practices were designed to treat the first flush of runoff or water quality event. The LID site incorporated the use of bioretention, permeable concrete, and constructed wetlands. Seven bioretention cells of varying media depths (0.6-m and 0.9-m) treated the front asphalt parking lot, and permeable concrete treated the rear parking lot. Storage was added beneath the permeable concrete to completely capture a 2.5-cm event. The constructed wetlands treated rooftop runoff, miscellaneous paved areas, and outparcel lots. Each LID practice was monitored as a separate unit and the site was monitored as a whole system. Effluent was monitored from the retention basin at the site with traditional stormwater treatment. A mixture of parking lot and rooftop runoff was monitored at the site with no stormwater controls. In addition to the water quality and hydrology results, much was learned about the construction and implementation of multiple and large scale LID practices at one site. LID practices are typically more sensitive practices, so proper construction oversight, installation, and maintenance are vital to adequate functioning of these stormwater treatment devices. Errors at this site included: undersized bioretention cells, clogged bioretention cells, a continuously flowing bioretention cell due to interception of the water table, and constructed wetlands that remained flooded, resulting in vegetation die off.

  • Modeling Bioretention Hydrology with DRAINMOD

    by Robert A. Brown, William F. Hunt, R. Wayne Skaggs

    It has been documented that bioretention cells are an effective low impact development (LID) stormwater practice to remove nitrogen, phosphorus, and other pollutants at high rates, as well as to restore a site's pre-developed hydrology. However, hydrologic performance has varied greatly in past field studies because of the impact of underlying soils, physiographic regions, drainage configuration, and media depth. Development of a long-term hydrologic model that generates an annual water balance is needed to more accurately describe hydrologic performance to predict pollutant loads and to determine whether a site meets LID hydrology criteria. The only models available are either unable to run continuous simulations or do not accurately model underdrain flow for typical designs of bioretention cells. DRAINMOD, a widely accepted long-term agricultural drainage model, is being used to predict bioretention hydrology. The concepts of water movement in bioretention cells are very similar to agricultural fields with drainage pipes, so many bioretention design specifications correspond directly to DRAINMOD inputs. As a result, calibration of DRAINMOD to model bioretention hydrology is currently underway. Detailed hydrologic data have been specifically collected from two field sites over the past 24 months to calibrate the model. Additional hydrology data are available from at least 10 other bioretention cells across NC to validate the model. DRAINMOD is also unique from other bioretention models in that it accounts for evapotranspiration (ET), and the controlling factor in DRAINMOD is the drainage configuration which employs the Richards Equation. The model can be used on an hour-by-hour basis for long periods of climatological records (e.g. 50 years). Hydrologic outputs from the model include: volume of runoff, overflow, drainage, exfiltration, and ET. These outputs will allow users to examine the water balance to discern a most suitable design based on varying design configurations.


  • Field Study of the Ability of Two Grassed Bioretention Cells to Reduce Storm-Water Runoff Pollution

    by Elodie Passeport, William F. Hunt, Daniel E. Line, Ryan A. Smith, Robert A. Brown

    Two grassed bioretention cells including internal storage zones (ISZs) were monitored for 16 months in central North Carolina. Each cell had a surface area of 106 m2 and fill media depths were 0.75 and 1.05 m for the north (North) and the south (South) cells, respectively. Asphalt parking lot inflow and outflows were analyzed for nitrogen and phosphorus forms and fecal coliform (FC). Outflow volumes and peak flows for individual storms were generally less than those of inflow. Overall, except for N O2,3 –N , effluent nitrogen species event mean concentrations (EMCs) and loads were significantly (α=0.05) lower than those of the inflow, and nitrogen species load reductions ranged from 47 to 88%. Apart from fall and winter, during which a longer hydraulic contact time seemed to be needed, the ISZs appeared to improve denitrification. Total phosphorus (TP) and OP O4 -P EMCs were significantly lower than those of the inlet. Reductions were 58% (South) and 63% (North) for TP and 78% (North) and 74% (South) for ...


  • Bioretention/Bioinfiltration Performance in the Mid-Atlantic

    by R. A. Brown, W. F. Hunt, A. P. Davis, R. G. Traver, J. M. Olszewski

    Researchers in Maryland, North Carolina, and Pennsylvania have been conducting parallel bioretention/bioinfiltration research since fall 2007. Various designs have been tested including those that rely on underdrains, have internal water storage (IWS) layers, or are underdrain-free. The cells provide a range of watershed practice size ratios and employ a variety of land covers. Researchers are pooling water quantity and quality data to help create new design standards. Initial results from the shared data will be presented, with specific attention to bioretention design parameters that control flow modification and water quality improvement. Two bioretention cells of varying vegetative cover are being monitored in Rocky Mount, NC. This site is located in the upper coastal plain with sandy in-situ soils. These cells were designed with a 0.9 m media depth and a 0.6 m deep internal water storage (IWS) layer. Another bioretention cell is being monitored in Silver Spring, MD. It was constructed with a 0.9 m media depth and a 0.3 m pooling depth. Finally, there are two bioinfiltration cells being monitored in Villanova, PA. The first is the "Traffic Island" bioinfiltration cell, which has been monitored since 2003. The bowl is only designed for 1.2 cm over the impervious surface, yet overflow rarely occurs for events less than 5.1 cm. The site had groundwater wells installed in 2007 and is the subject of an ongoing study on the groundwater effects. The second site has only been monitored for approximately six months. Cumulatively, the four bioretention cells extensively examined have dramatically reduced outflow volumes, completely assimilating all events less than 1.2 cm — and in some designs much greater events. By aggregating the data, runoff reduction by bioretention can be profound.