Volkher Scharnhorst
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Volkher Scharnhorst has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Eveline Besselaar
MD, Internal Medicine, Catharina Hospital , Eindhoven , The Netherlands
1 shared publicationKrisztina Krasznai
Cardiology Department, Catharina Hospital, Eindhoven, the Netherlands
1 shared publicationMarcel van 'T Veer
Cardiology Department, Catharina Hospital, Eindhoven, the Netherlands
1 shared publicationMiranda van Berkel
Clinical Laboratory, Catharina Hospital Eindhoven, Eindhoven, The Netherlands
1 shared publication- Miranda van Berkel
PhD, Clinical Laboratory, Catharina Hospital , Eindhoven , The Netherlands
1 shared publication Philip Kuijper
PhD, Clinical Laboratory, Máxima Medical Center , Veldhoven , The Netherlands
1 shared publication
Latest Publications
- 8 January 2013
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 51 (6) , e137-e139
Instrument-dependent interference of Howell-Jolly bodies in reticulocyte enumeration
- 8 January 2013
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 51 (6) , e137-e139
Instrument-dependent interference of Howell-Jolly bodies in reticulocyte enumeration
- 1 August 2012
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 58 (8) , 1208-1214
Variation of Cardiac Troponin I and T Measured with Sensitive Assays in Emergency Department Patients with Noncardiac Chest Pain
BACKGROUND: New-generation high-sensitivity assays for cardiac troponin have lower detection limits and less imprecision than earlier assays. Reference 99th-percentile cutoff values for these new assays are also lower, leading to higher frequencies of positive test results. When cardiac troponin concentrations are minimally increased, serial testing allows discrimination of myocardial infarction from other causes of increased cardiac troponin. We assessed various measures of short-term variation, including absolute concentration changes, reference change values (RCVs), and indices of individuality (II) for 2 cardiac troponin assays in emergency department (ED) patients. METHODS: We collected blood from patients presenting with cardiac chest pain upon arrival in the ED and 2, 6, and 12 h later. Cardiac troponin was measured with the high-sensitivity cardiac troponin T (hs-cTnT) assay (Roche Diagnostics) and a sensitive cTnI assay (Siemens Diagnostics). Cardiac troponin results from 67 patients without acute coronary syndrome or stable angina were used in calculating absolute changes in cardiac troponin, RCVs, and II. RESULTS: The 95th percentiles for absolute change in cardiac troponin were 8.3 ng/L for hs-cTnT and 28 ng/L for cTnI. Within-individual and total CVs were 11% and 14% for hs-cTnT and 18% and 21% for cTnI, respectively. RCVs were 38% (hs-cTnT) and 57% (cTnI). The corresponding log-normal RCVs were +46%/−32% for hs-cTnT and +76%/−43% for cTnI. II values were 0.31 (cTnI) and 0.12 (hs-cTnT). CONCLUSIONS: The short-term variations and IIs of cardiac troponin were low in ED patients free of ischemic myocardial necrosis. The detection of cardiac troponin variation exceeding reference thresholds can help to identify ED patients with acute myocardial necrosis whereas variation within these limits renders acute coronary syndrome unlikely.
- 1 August 2012
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 58 (8) , 1208-1214
Variation of Cardiac Troponin I and T Measured with Sensitive Assays in Emergency Department Patients with Noncardiac Chest Pain
BACKGROUND: New-generation high-sensitivity assays for cardiac troponin have lower detection limits and less imprecision than earlier assays. Reference 99th-percentile cutoff values for these new assays are also lower, leading to higher frequencies of positive test results. When cardiac troponin concentrations are minimally increased, serial testing allows discrimination of myocardial infarction from other causes of increased cardiac troponin. We assessed various measures of short-term variation, including absolute concentration changes, reference change values (RCVs), and indices of individuality (II) for 2 cardiac troponin assays in emergency department (ED) patients. METHODS: We collected blood from patients presenting with cardiac chest pain upon arrival in the ED and 2, 6, and 12 h later. Cardiac troponin was measured with the high-sensitivity cardiac troponin T (hs-cTnT) assay (Roche Diagnostics) and a sensitive cTnI assay (Siemens Diagnostics). Cardiac troponin results from 67 patients without acute coronary syndrome or stable angina were used in calculating absolute changes in cardiac troponin, RCVs, and II. RESULTS: The 95th percentiles for absolute change in cardiac troponin were 8.3 ng/L for hs-cTnT and 28 ng/L for cTnI. Within-individual and total CVs were 11% and 14% for hs-cTnT and 18% and 21% for cTnI, respectively. RCVs were 38% (hs-cTnT) and 57% (cTnI). The corresponding log-normal RCVs were +46%/−32% for hs-cTnT and +76%/−43% for cTnI. II values were 0.31 (cTnI) and 0.12 (hs-cTnT). CONCLUSIONS: The short-term variations and IIs of cardiac troponin were low in ED patients free of ischemic myocardial necrosis. The detection of cardiac troponin variation exceeding reference thresholds can help to identify ED patients with acute myocardial necrosis whereas variation within these limits renders acute coronary syndrome unlikely.
- 23 November 2010
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 49 (2) , 249-252
Electrolyte-balanced heparin in blood gas syringes can introduce a significant bias in the measurement of positively charged electrolytes
Background: Heparin binds positively charged electrolytes. In blood gas syringes, electrolyte-balanced heparin is used to prevent a negative bias in electrolyte concentrations. The potential pre-analytical errors introduced by blood gas syringes are largely unknown. Here, we evaluate electrolyte concentrations in non-anticoagulated blood compared with concentrations measured in electrolyte-balanced blood gas syringes. Methods: Venous blood was collected into plain tubes. Ioni-zed calcium, potassium, sodium and hydrogen ions were analyzed directly using a blood gas analyzer and the remaining blood was collected into different blood gas syringes in random order: Preset (Becton Dickinson), Monovette (Sar-stedt) and Pico 50-2 (Radiometer). Results: Ionized calcium and sodium concentrations were significantly lower in blood collected in Becton Dickinson and Sarstedt syringes compared to non-heparinized (NH) blood. The mean bias exceeded biological variation-based total allowable error, which in most cases leads to clinically misleading individual results. In contrast, ionized calcium concentrations in blood collected in Pico 50-2 syringes were identical to values obtained from NH blood. Sodium showed a minor, yet statistically significant, bias. Conclusions: Despite the fact that blood gas syringes now contain electrolyte-balanced heparin, one should be aware of the fact that these syringes can introduce pre-analytical bias in electrolyte concentrations. The extent of the bias differs between syringes.
- 23 November 2010
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 49 (2) , 249-252
Electrolyte-balanced heparin in blood gas syringes can introduce a significant bias in the measurement of positively charged electrolytes
Background: Heparin binds positively charged electrolytes. In blood gas syringes, electrolyte-balanced heparin is used to prevent a negative bias in electrolyte concentrations. The potential pre-analytical errors introduced by blood gas syringes are largely unknown. Here, we evaluate electrolyte concentrations in non-anticoagulated blood compared with concentrations measured in electrolyte-balanced blood gas syringes. Methods: Venous blood was collected into plain tubes. Ioni-zed calcium, potassium, sodium and hydrogen ions were analyzed directly using a blood gas analyzer and the remaining blood was collected into different blood gas syringes in random order: Preset (Becton Dickinson), Monovette (Sar-stedt) and Pico 50-2 (Radiometer). Results: Ionized calcium and sodium concentrations were significantly lower in blood collected in Becton Dickinson and Sarstedt syringes compared to non-heparinized (NH) blood. The mean bias exceeded biological variation-based total allowable error, which in most cases leads to clinically misleading individual results. In contrast, ionized calcium concentrations in blood collected in Pico 50-2 syringes were identical to values obtained from NH blood. Sodium showed a minor, yet statistically significant, bias. Conclusions: Despite the fact that blood gas syringes now contain electrolyte-balanced heparin, one should be aware of the fact that these syringes can introduce pre-analytical bias in electrolyte concentrations. The extent of the bias differs between syringes.