L. Sebastian Bryson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
L. Sebastian Bryson has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- David Guillermo Zapata-Medina
Universidad Nacional de Colombia
3 shared publications Ali Salehian
ENGEO
2 shared publicationsI. C. Gomez-Gutierrez
Assistant Professor, Department of Civil Engineering, 161 Raymond Bldg., University of Kentucky, Lexington, KY 40506, USA
2 shared publicationsRyan Ortiz
Associate Professor, Department of Civil Engineering, 161 Raymond Bldg., University of Kentucky, Lexington, KY 40506 USA
2 shared publicationsT. C. Hopkins
Assistant Professor, Department of Civil Engineering, 161 Raymond Bldg., University of Kentucky, Lexington, KY 40506, USA
2 shared publicationsC. L. Yohe
Associate Professor, Department of Civil Engineering, 161 Raymond Bldg., University of Kentucky, Lexington, KY 40506, USA
1 shared publication
Latest Publications
- 13 May 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 288-297
Influence of Mineralogy on the Index Properties and Durability of Crushed Shales
Weak shale formations in oil shale production are the primary cause of instability in drill holes due to sloughing and swelling. During and after the drilling, shales continuously absorb water and consequently deteriorate with time. The effect of the deterioration results in the transformation of a hard rock with high cohesion and frictional resistance to a soft, fine-grained mass without cohesion, lower shear strength, and high swelling susceptibility. As a result, the shales swell and slough into the hole. Shales are primarily composed of varying amounts of clay minerals (i.e. chlorite, mixed layer illite-smectite, illite, and kaolinte), quartz, and other minerals such as carbonates, pyrite or iron oxides. In particular, understanding the influence of clay minerals on the shale is crucial to understanding the mechanical behavior of shales. This is because clays are highly reactive minerals in the presence of water. Due to this reactivity, shales tend to be highly susceptible to deterioration. This paper investigates the association between shale mineralogy and mechanical characteristics. For this study, shale samples were collected from a variety of locations in Kentucky. The specimens were assumed to be representative of hard and soft shales with high, medium, and low durability. These samples were crushed and laboratory testing was performed. The lab tests included index tests, mineralogical tests, and durability tests. It was observed from the results of this study that the mineralogy explained the activity and variations in several index properties, as well as the durability of the samples.
- 13 May 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 288-297
Influence of Mineralogy on the Index Properties and Durability of Crushed Shales
Weak shale formations in oil shale production are the primary cause of instability in drill holes due to sloughing and swelling. During and after the drilling, shales continuously absorb water and consequently deteriorate with time. The effect of the deterioration results in the transformation of a hard rock with high cohesion and frictional resistance to a soft, fine-grained mass without cohesion, lower shear strength, and high swelling susceptibility. As a result, the shales swell and slough into the hole. Shales are primarily composed of varying amounts of clay minerals (i.e. chlorite, mixed layer illite-smectite, illite, and kaolinte), quartz, and other minerals such as carbonates, pyrite or iron oxides. In particular, understanding the influence of clay minerals on the shale is crucial to understanding the mechanical behavior of shales. This is because clays are highly reactive minerals in the presence of water. Due to this reactivity, shales tend to be highly susceptible to deterioration. This paper investigates the association between shale mineralogy and mechanical characteristics. For this study, shale samples were collected from a variety of locations in Kentucky. The specimens were assumed to be representative of hard and soft shales with high, medium, and low durability. These samples were crushed and laboratory testing was performed. The lab tests included index tests, mineralogical tests, and durability tests. It was observed from the results of this study that the mineralogy explained the activity and variations in several index properties, as well as the durability of the samples.
- 24 February 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 3252-3261
Lab-Scale Study of Ultrafine Cement Grout Curtains Using a Physical Model
Curtain grouting is a construction technique by which a continuous grout wall is formed from a series of cylindrical columns placed adjacent to one another. Grout curtains are typically used in permeable soil or rock masses to decrease seepage. Grout curtains are vital to dam and other earthen impoundment restoration projects. In particular cement grouts, such as ultrafine grout, have proven to be very effective in reducing seepage through these impoundments. While the primary purpose of curtain grouting is for seepage control, mechanical behavior of the grouted mass such as excessive settlement and lateral movement is also of concern. In this study, an apparatus and methodology for a lab-scale physical model of curtain grouting was developed. Various measures of mechanical behavior related to grout curtain field practices were investigated. These measures included cure time and interface strength between the soil and grout. In addition, the grout-soil interface strength was a minimum of 66% more than the sand-sand interface strength. This study showed that a lab-scale grout curtain can be adequately implemented to evaluate grout curtain behavior. Finally, this research showed that utilizing a lab-scale physical model of a grout curtain is a valid approach for investigating field-scale grout curtain effectiveness.
- 24 February 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 3252-3261
Lab-Scale Study of Ultrafine Cement Grout Curtains Using a Physical Model
Curtain grouting is a construction technique by which a continuous grout wall is formed from a series of cylindrical columns placed adjacent to one another. Grout curtains are typically used in permeable soil or rock masses to decrease seepage. Grout curtains are vital to dam and other earthen impoundment restoration projects. In particular cement grouts, such as ultrafine grout, have proven to be very effective in reducing seepage through these impoundments. While the primary purpose of curtain grouting is for seepage control, mechanical behavior of the grouted mass such as excessive settlement and lateral movement is also of concern. In this study, an apparatus and methodology for a lab-scale physical model of curtain grouting was developed. Various measures of mechanical behavior related to grout curtain field practices were investigated. These measures included cure time and interface strength between the soil and grout. In addition, the grout-soil interface strength was a minimum of 66% more than the sand-sand interface strength. This study showed that a lab-scale grout curtain can be adequately implemented to evaluate grout curtain behavior. Finally, this research showed that utilizing a lab-scale physical model of a grout curtain is a valid approach for investigating field-scale grout curtain effectiveness.
- 24 February 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 2450-2459
Performance of Nonnuclear Devices for In Situ Moisture and Density Determination
The largest portion of highway construction cost is in the earthwork phase. Inadequate soil subgrade compaction can cause structural failure of the roadway and infrastructure. Quality control of compacted soil subgrade is commonly performed using the nuclear density gauge. However, growing concerns over the safety of using the device with a radioactive source and training and calibration costs have warranted an effort to replace the nuclear density gauge. Several nonnuclear devices have been developed for the determination of in situ soil moisture density. These devices all utilize electromagnetic wave propagation theory to obtain frequency-dependent electrical measurements in a soil mass. These electrical measurements are subsequently related to soil properties such as moisture and density. Three of these devices were selected for this study to evaluate their performance and applicability for use in the field. The soil density gauge, electrical density gauge, and moisture and density indicator were examined at four construction sites to evaluate their reliability, repeatability, and usability under field conditions. In these tests, the density measurements of the devices were compared with densities obtained from a sand cone density apparatus and from a nuclear density gauge. Measurements of moisture content were compared with oven-derived moisture contents. Difficulties in device operation were also noted. This study found that the device based on electromagnetic impedance spectroscopy provided the most repeatable results and was easiest to use. Despite the criticism that its main algorithms are not accessible for user modification and site-specific calibration, this device appears to the most feasible device for replacement of the nuclear density gauge.
- 24 February 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 2450-2459
Performance of Nonnuclear Devices for In Situ Moisture and Density Determination
The largest portion of highway construction cost is in the earthwork phase. Inadequate soil subgrade compaction can cause structural failure of the roadway and infrastructure. Quality control of compacted soil subgrade is commonly performed using the nuclear density gauge. However, growing concerns over the safety of using the device with a radioactive source and training and calibration costs have warranted an effort to replace the nuclear density gauge. Several nonnuclear devices have been developed for the determination of in situ soil moisture density. These devices all utilize electromagnetic wave propagation theory to obtain frequency-dependent electrical measurements in a soil mass. These electrical measurements are subsequently related to soil properties such as moisture and density. Three of these devices were selected for this study to evaluate their performance and applicability for use in the field. The soil density gauge, electrical density gauge, and moisture and density indicator were examined at four construction sites to evaluate their reliability, repeatability, and usability under field conditions. In these tests, the density measurements of the devices were compared with densities obtained from a sand cone density apparatus and from a nuclear density gauge. Measurements of moisture content were compared with oven-derived moisture contents. Difficulties in device operation were also noted. This study found that the device based on electromagnetic impedance spectroscopy provided the most repeatable results and was easiest to use. Despite the criticism that its main algorithms are not accessible for user modification and site-specific calibration, this device appears to the most feasible device for replacement of the nuclear density gauge.
- 24 February 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 3233-3242
Effects of a Grout Curtain on Hydraulic and Electrical Conductivity in a Laboratory-Scale Seepage Model
Electrical conductivity measurements have been proven effective in the estimation of soil properties, such as degree of saturation, moisture content, and porosity. These properties have been shown to relate to hydraulic conductivity. A relationship between electrical conductivity and hydraulic conductivity would enhance the monitoring of seepage behavior of geotechnical processes, such as evaluating the effectiveness of grout curtains. Grout curtains involve the installation of cylindrical grout columns to form a continuous wall of grout. This technique has been used successfully to minimize seepage through dams and other earthen impoundments. A relationship between electrical conductivity and hydraulic conductivity is assumed to be beneficial for assessing the effectiveness of a grout curtain. In this study, a lab-scale model was developed to investigate the viability of using electrical conductivity measurements to assess seepage behavior. A laboratory-scale physical model was used to develop a relationship between hydraulic behavior and electrical conductivity measurements. For this research, a simulated grout curtain was installed in a seepage model. The effect of the grout curtain installation sequence on the seepage measurements was investigated. This study described the grout curtain installation sequence in terms of a linear replacement ratio. This ratio is the linear width of the acrylic material to width of the seepage model. This study found an empirical relationship exists between hydraulic conductivity and the linear replacement ratio. A trend was also found between electrical and hydraulic conductivity.
- 24 February 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 3233-3242
Effects of a Grout Curtain on Hydraulic and Electrical Conductivity in a Laboratory-Scale Seepage Model
Electrical conductivity measurements have been proven effective in the estimation of soil properties, such as degree of saturation, moisture content, and porosity. These properties have been shown to relate to hydraulic conductivity. A relationship between electrical conductivity and hydraulic conductivity would enhance the monitoring of seepage behavior of geotechnical processes, such as evaluating the effectiveness of grout curtains. Grout curtains involve the installation of cylindrical grout columns to form a continuous wall of grout. This technique has been used successfully to minimize seepage through dams and other earthen impoundments. A relationship between electrical conductivity and hydraulic conductivity is assumed to be beneficial for assessing the effectiveness of a grout curtain. In this study, a lab-scale model was developed to investigate the viability of using electrical conductivity measurements to assess seepage behavior. A laboratory-scale physical model was used to develop a relationship between hydraulic behavior and electrical conductivity measurements. For this research, a simulated grout curtain was installed in a seepage model. The effect of the grout curtain installation sequence on the seepage measurements was investigated. This study described the grout curtain installation sequence in terms of a linear replacement ratio. This ratio is the linear width of the acrylic material to width of the seepage model. This study found an empirical relationship exists between hydraulic conductivity and the linear replacement ratio. A trend was also found between electrical and hydraulic conductivity.
- 24 February 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 4115-4124
Soil Water Characteristic Curves from Measures of Electrical Permittivity
As the need for infrastructure increases, so must the understanding of soils under in situ or natural conditions. Soils in in situ conditions typically exist in an unsaturated state. Unsaturated soils exhibit different engineering behavior and responses than saturated soils. Therefore, methods must be developed to predict the behavior of unsaturated soils under in situ conditions. The soil water characteristic curve relates moisture content to matric suction of a soil for a given soil structure and is the primary means used to describe behavior and characteristics of unsaturated soils. Electrical parameters such as electrical permittivity have been used successfully to predict moisture content in soils. However, further research is required to assess if electrical parameters relate to soil suction and thus can become an alternative means to establish the soil water characteristic curve. In this study, correlations were investigated between soil water characteristic curve parameters and measures of electrical permittivity. The permittivity values were analyzed with respect to their variations with matric suction, volumetric water content, and dry unit weight. This study found that both volumetric water content and matric suction can be expressed as a function of the electrical permittivity; thus providing a possible means of determining an insitu soil water characteristic curve.
- 24 February 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 4115-4124
Soil Water Characteristic Curves from Measures of Electrical Permittivity
As the need for infrastructure increases, so must the understanding of soils under in situ or natural conditions. Soils in in situ conditions typically exist in an unsaturated state. Unsaturated soils exhibit different engineering behavior and responses than saturated soils. Therefore, methods must be developed to predict the behavior of unsaturated soils under in situ conditions. The soil water characteristic curve relates moisture content to matric suction of a soil for a given soil structure and is the primary means used to describe behavior and characteristics of unsaturated soils. Electrical parameters such as electrical permittivity have been used successfully to predict moisture content in soils. However, further research is required to assess if electrical parameters relate to soil suction and thus can become an alternative means to establish the soil water characteristic curve. In this study, correlations were investigated between soil water characteristic curve parameters and measures of electrical permittivity. The permittivity values were analyzed with respect to their variations with matric suction, volumetric water content, and dry unit weight. This study found that both volumetric water content and matric suction can be expressed as a function of the electrical permittivity; thus providing a possible means of determining an insitu soil water characteristic curve.
- 7 November 2013
- Published by Springer Nature in Geotechnical and Geological Engineering
- Vol. 32 (2) , 247-258
Sensitivity Analysis of Selected Input Parameters for an Advanced Constitutive Model
- 7 November 2013
- Published by Springer Nature in Geotechnical and Geological Engineering
- Vol. 32 (2) , 247-258
Sensitivity Analysis of Selected Input Parameters for an Advanced Constitutive Model
- 25 February 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 1002-1012
Stability Analysis of the L-575 Levee Failure on the Missouri River
The breach of a levee can be a devastating event, with each occurrence possibly resulting in millions of dollars in damages. Despite the destructive potential associated with a breach, there is a great deal of uncertainty associated with the current conditions of levees in the United States. Not only do soil parameters often vary a great deal throughout an earthen structure, but there is also very little information available on the soil parameters and design techniques used in the design and construction of these levees. This is particularly the case for levees that are 50 years old or more. This study focused on one such levee failure: the June 13, 2011 breach of levee L-575 near River Mile 552 on the Missouri River. A two-dimensional model of the levee was constructed using the SLOPE/W and SEEP/W software. Geometry of the levee and the site characteristics at failure were established through investigation of public domain information. The likely mean strength parameters of the soil were established through sensitivity analysis. A probabilistic analysis was then performed to evaluate the probability of the levee's unsatisfactory performance, as defined by incipient instability and as defined by the U.S. Army Corps of Engineers' minimum criteria. The probabilistic analysis revealed that there was less than a 20 percent probability of instability in levee L-575. However, there was more than a 90 percent probability that L-575 would perform unsatisfactorily with respect to the U.S. Army Corps of Engineers' minimum criteria.
- 25 February 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 1002-1012
Stability Analysis of the L-575 Levee Failure on the Missouri River
The breach of a levee can be a devastating event, with each occurrence possibly resulting in millions of dollars in damages. Despite the destructive potential associated with a breach, there is a great deal of uncertainty associated with the current conditions of levees in the United States. Not only do soil parameters often vary a great deal throughout an earthen structure, but there is also very little information available on the soil parameters and design techniques used in the design and construction of these levees. This is particularly the case for levees that are 50 years old or more. This study focused on one such levee failure: the June 13, 2011 breach of levee L-575 near River Mile 552 on the Missouri River. A two-dimensional model of the levee was constructed using the SLOPE/W and SEEP/W software. Geometry of the levee and the site characteristics at failure were established through investigation of public domain information. The likely mean strength parameters of the soil were established through sensitivity analysis. A probabilistic analysis was then performed to evaluate the probability of the levee's unsatisfactory performance, as defined by incipient instability and as defined by the U.S. Army Corps of Engineers' minimum criteria. The probabilistic analysis revealed that there was less than a 20 percent probability of instability in levee L-575. However, there was more than a 90 percent probability that L-575 would perform unsatisfactorily with respect to the U.S. Army Corps of Engineers' minimum criteria.
- 13 November 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 286-295
A Case Study of a Ground Slip during the Installation of an HDPE Pipe
This paper presents a case study of a slide that occurred during the construction of the initial starter dam for a planned four-stage coal refuse impoundment located in Eastern Kentucky. During the installation of 1700 linear feet of 36-inch HDPE decant pipe, loading from coarse refuse placement on a side hill adjacent to the pipe alignment and future embankment initiated a slide in natural ground prior to the construction of the dam embankment. This slide caused a 300-foot section of pipe to displace laterally and vertically. This paper presents the lessons learned from the remediation of this slide and the repairs made to the decant pipe. It also presents the challenges that developed as construction progressed and operation commenced as well as challenges that developed as later stages were proposed and constructed. This paper also examines the economic, regulatory, and maintenance and inspection challenges created in later stages of the permitting and design process as a result of the initial remedial efforts and the course of action taken.
- 13 November 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 286-295
A Case Study of a Ground Slip during the Installation of an HDPE Pipe
This paper presents a case study of a slide that occurred during the construction of the initial starter dam for a planned four-stage coal refuse impoundment located in Eastern Kentucky. During the installation of 1700 linear feet of 36-inch HDPE decant pipe, loading from coarse refuse placement on a side hill adjacent to the pipe alignment and future embankment initiated a slide in natural ground prior to the construction of the dam embankment. This slide caused a 300-foot section of pipe to displace laterally and vertically. This paper presents the lessons learned from the remediation of this slide and the repairs made to the decant pipe. It also presents the challenges that developed as construction progressed and operation commenced as well as challenges that developed as later stages were proposed and constructed. This paper also examines the economic, regulatory, and maintenance and inspection challenges created in later stages of the permitting and design process as a result of the initial remedial efforts and the course of action taken.
- 1 September 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 138 (9) , 1104-1115
Method for Estimating System Stiffness for Excavation Support Walls
Excessive excavation-induced movements are major concerns for most underground construction projects in urban areas. These movements can lead to significant damage in adjacent structures. When average to good workmanship is employed during the installation process of the excavation support systems, the consequent ground movements are most influenced by the support system stiffness. Therefore, choosing the most appropriate stiffness for an excavation support system is crucial to minimizing excavation-related damage to adjacent buildings and utilities. This paper presents a semiempirical design methodology that facilitates the selecting of the excavation support system stiffness in such a way that limits excavation-related ground movement. As part of the proposed design methodology, a new parameter was developed called the relative stiffness ratio. This new parameter relates the strength and stiffness of the soil with the stiffness of the excavation support system and was developed from a comprehens...
- 1 September 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 138 (9) , 1104-1115
Method for Estimating System Stiffness for Excavation Support Walls
Excessive excavation-induced movements are major concerns for most underground construction projects in urban areas. These movements can lead to significant damage in adjacent structures. When average to good workmanship is employed during the installation process of the excavation support systems, the consequent ground movements are most influenced by the support system stiffness. Therefore, choosing the most appropriate stiffness for an excavation support system is crucial to minimizing excavation-related damage to adjacent buildings and utilities. This paper presents a semiempirical design methodology that facilitates the selecting of the excavation support system stiffness in such a way that limits excavation-related ground movement. As part of the proposed design methodology, a new parameter was developed called the relative stiffness ratio. This new parameter relates the strength and stiffness of the soil with the stiffness of the excavation support system and was developed from a comprehens...
- 1 December 2011
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 25 (6) , 491-503
Cracking in Walls of a Building Adjacent to a Deep Excavation
A major concern for projects involving deep excavations in urban areas is the response of adjacent buildings and utilities to excavation-related ground movements. Unfortunately, a purely theoretical approach to estimating building response to excavation-related deformations is not possible due to the variability of the many factors that contribute to the response. Consequently, building response must be estimated and evaluated primarily based on empirical observations and various structural approximations. The goal of estimating and evaluating building response is to provide limiting criteria that will safeguard the structure against unacceptable damage. Thus, estimating the extent of the building response and consequently the severity of excavation-related building damage is critical to establishing rational limiting criteria for excavation support system designs. The most common measure of damage severity is the onset and growth of cracks in interior walls of adjacent structures. Although several proced...
- 1 December 2011
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 25 (6) , 491-503
Cracking in Walls of a Building Adjacent to a Deep Excavation
A major concern for projects involving deep excavations in urban areas is the response of adjacent buildings and utilities to excavation-related ground movements. Unfortunately, a purely theoretical approach to estimating building response to excavation-related deformations is not possible due to the variability of the many factors that contribute to the response. Consequently, building response must be estimated and evaluated primarily based on empirical observations and various structural approximations. The goal of estimating and evaluating building response is to provide limiting criteria that will safeguard the structure against unacceptable damage. Thus, estimating the extent of the building response and consequently the severity of excavation-related building damage is critical to establishing rational limiting criteria for excavation support system designs. The most common measure of damage severity is the onset and growth of cracks in interior walls of adjacent structures. Although several proced...