Jing Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jing Chen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Yiping Zhao
The University of Georgia
5 shared publications Yao-Wen Huang
Department of Food Science and Technology
3 shared publications- Caiqin Han
Jiangsu Key Laboratory of Advanced Laser Materials and Devices School of Physics and Electronic Engineering Jiangsu Normal University Xuzhou China
1 shared publication - Justin L. Abell
Nanoscale Science and Engineering Center, Department of Biological and Agricultural Engineering, University of Georgia, Athens, GA, USA
1 shared publication - Susu M. Zughaier
College of Medicine, QU Health, Qatar University, Doha P.O. Box 2731, Qatar
1 shared publication Xiaomeng Wu
Nanoscale Science and Engineering Center, University of Georgia, USA; Department of Food Science and Technology, University of Georgia, USA
1 shared publication
Latest Publications
- 2 January 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 3 (9) , 1898-1906
Detection of polycyclic aromatic hydrocarbons from cooking oil using ultra-thin layer chromatography and surface enhanced Raman spectroscopy
The combinatory use of on-chip ultra-thin layer chromatography (UTLC) and surface enhanced Raman spectroscopy (SERS) has been demonstrated to detect mixtures of hazardous food contaminants, polycyclic aromatic hydrocarbons (PAHs), from cooking oil samples. After a simple acetonitrile extraction step, the organic phase was directly applied to the chemically modified SERS-active silver nanorod (AgNR) substrate without further cleanup, and subjected to UTLC separation. The spectral interference from co-extracted oil residues was mitigated by UTLC, and the SERS detection limits were found to be equivalent to or lower than those found in standard PAH solutions. The interference from the oil matrix was also quantitatively assessed, and the PAH extraction procedure was optimized for UTLC-SERS. This UTLC-SERS strategy provides a simple but effective method for on-chip sample cleanup and sensing from complex sample matrices.
- 2 January 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 3 (9) , 1898-1906
Detection of polycyclic aromatic hydrocarbons from cooking oil using ultra-thin layer chromatography and surface enhanced Raman spectroscopy
The combinatory use of on-chip ultra-thin layer chromatography (UTLC) and surface enhanced Raman spectroscopy (SERS) has been demonstrated to detect mixtures of hazardous food contaminants, polycyclic aromatic hydrocarbons (PAHs), from cooking oil samples. After a simple acetonitrile extraction step, the organic phase was directly applied to the chemically modified SERS-active silver nanorod (AgNR) substrate without further cleanup, and subjected to UTLC separation. The spectral interference from co-extracted oil residues was mitigated by UTLC, and the SERS detection limits were found to be equivalent to or lower than those found in standard PAH solutions. The interference from the oil matrix was also quantitatively assessed, and the PAH extraction procedure was optimized for UTLC-SERS. This UTLC-SERS strategy provides a simple but effective method for on-chip sample cleanup and sensing from complex sample matrices.
- 14 November 2014
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 46 (1) , 64-69
Characterization of polycyclic aromatic hydrocarbons using Raman and surface-enhanced Raman spectroscopy
Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous atmospheric pollutants and food contaminants, which exhibit potent carcinogenicity, mutagenicity, and teratogenicity. Vibrational spectroscopy techniques, especially Raman spectroscopy and surface-enhanced Raman spectroscopy (SERS), can be potentially used as an alternative technique to liquid and gas chromatography in PAH analysis. However, there is limited information on the intrinsic Raman and SERS fingerprints of PAHs. In this study, we have acquired the Raman and SERS spectra of seven PAH compounds and compared their experimental spectra with theoretical Raman spectra calculated by density function theory (DFT). The vibrational modes corresponding to the Raman peaks have also been assigned using DFT. Characteristic Raman and SERS peaks have been identified for five PAH compounds, and the limits of detection were estimated. Such information could be useful for developing SERS assays for simple and rapid PAH identification. Copyright © 2014 John Wiley & Sons, Ltd.
- 14 November 2014
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 46 (1) , 64-69
Characterization of polycyclic aromatic hydrocarbons using Raman and surface-enhanced Raman spectroscopy
Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous atmospheric pollutants and food contaminants, which exhibit potent carcinogenicity, mutagenicity, and teratogenicity. Vibrational spectroscopy techniques, especially Raman spectroscopy and surface-enhanced Raman spectroscopy (SERS), can be potentially used as an alternative technique to liquid and gas chromatography in PAH analysis. However, there is limited information on the intrinsic Raman and SERS fingerprints of PAHs. In this study, we have acquired the Raman and SERS spectra of seven PAH compounds and compared their experimental spectra with theoretical Raman spectra calculated by density function theory (DFT). The vibrational modes corresponding to the Raman peaks have also been assigned using DFT. Characteristic Raman and SERS peaks have been identified for five PAH compounds, and the limits of detection were estimated. Such information could be useful for developing SERS assays for simple and rapid PAH identification. Copyright © 2014 John Wiley & Sons, Ltd.
- 1 November 2014
- Published by Elsevier in Nanomedicine: Nanotechnology, Biology and Medicine
- Vol. 10 (8) , 1863-1870
Culture-free diagnostics of Pseudomonas aeruginosa infection by silver nanorod array based SERS from clinical sputum samples
- 1 November 2014
- Published by Elsevier in Nanomedicine: Nanotechnology, Biology and Medicine
- Vol. 10 (8) , 1863-1870
Culture-free diagnostics of Pseudomonas aeruginosa infection by silver nanorod array based SERS from clinical sputum samples
- 24 April 2012
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (17) , 3096-3102
On-Chip Ultra-Thin Layer Chromatography and Surface Enhanced Raman Spectroscopy
We demonstrate that silver nanorod (AgNR) array substrates can be used for on-chip separation and detection of chemical mixtures by combining ultra-thin layer chromatography (UTLC) and surface enhanced Raman spectroscopy (SERS). The UTLC-SERS plate consists of an AgNR array fabricated by oblique angle deposition. The capability of the AgNR substrates to separate the different compounds in a mixture was explored using a mixture of four dyes and a mixture of melamine and Rhodamine 6G at varied concentrations with different mobile phase solvents. After UTLC separation, spatially-resolved SERS spectra were collected along the mobile phase development direction and the intensities of specific SERS peaks from each component were used to generate chromatograms. The AgNR substrates demonstrate the potential for separating the test dyes with plate heights as low as 9.6 μm. The limits of detection are between 10−5–10−6 M. Furthermore, we show that the coupling of UTLC with SERS improves the SERS detection specificity, as small amounts of target analytes can be separated from the interfering background components.
- 24 April 2012
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (17) , 3096-3102
On-Chip Ultra-Thin Layer Chromatography and Surface Enhanced Raman Spectroscopy
We demonstrate that silver nanorod (AgNR) array substrates can be used for on-chip separation and detection of chemical mixtures by combining ultra-thin layer chromatography (UTLC) and surface enhanced Raman spectroscopy (SERS). The UTLC-SERS plate consists of an AgNR array fabricated by oblique angle deposition. The capability of the AgNR substrates to separate the different compounds in a mixture was explored using a mixture of four dyes and a mixture of melamine and Rhodamine 6G at varied concentrations with different mobile phase solvents. After UTLC separation, spatially-resolved SERS spectra were collected along the mobile phase development direction and the intensities of specific SERS peaks from each component were used to generate chromatograms. The AgNR substrates demonstrate the potential for separating the test dyes with plate heights as low as 9.6 μm. The limits of detection are between 10−5–10−6 M. Furthermore, we show that the coupling of UTLC with SERS improves the SERS detection specificity, as small amounts of target analytes can be separated from the interfering background components.