PBPaul J. Barr

Paul J. Barr

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Paul J. Barr has a total of 33 co-authors. Here are the top co-authors by number of shared publications:

  • Marvin W. Halling

    Professor, Dept. of Civil and Environmental Engineering, Utah State Univ., 4110 Old Main Hill, Logan, UT 84332-4110

    17 shared publications
  • Steven M. Petroff

    PhD Student, Department of Civil and Environmental Engineering, Utah State University

    3 shared publications
  • Travis R. Brackus

    Graduate Research Assistant, Dept. of Civil and Environmental Engineering, Utah State Univ., Logan, UT 84332-4110

    3 shared publications
  • David A. Petty

    Graduate Research Assistant, Dept. of Civil and Environmental Engineering, Utah State Univ., 4110 Old Main Hill, Logan, UT 84332-4110

    2 shared publications
  • Dereck J. Hodson

    Graduate Student, Dept. of Civil and Environmental Engineering, Utah State Univ., Logan, UT 84322

    2 shared publications
  • G. Parry Osborn

    Graduate Research Assistant, Dept. of Civil and Environmental Engineering, Utah State Univ., 4110 Old Main Hill, Logan, UT 84332-4110

    2 shared publications

Latest Publications

  • Experimental and Analytical Investigation of Live-Load Distribution Factors for Double Tee Bridges

    by Victor Torres, Navid Zolghadri, Marc Maguire, Paul Barr, Marvin Halling

    In this study, the Icy Springs Bridge, located in Coalville, Utah, was load-tested to quantify the effects of significant deterioration on its live-load behavior. Visual inspection and load testing of this double tee structure indicated a severely deteriorated deck, undamaged girder stems, and partially effective transverse connections at the longitudinal joints. At the time of testing, the bridge was load-posted at 35.6 kN (total gross vehicle weight) with a maximum speed of 8  km/h due to conservative rating assumptions. After a detailed analysis, a truck that was 7.5 times the posted weight was used for a load test. A shell-based finite-element model was created that used variable spring elements to model the deteriorated flange-to-flange connections, which accurately replicated the behavior of the bridge from the load test and validated the modeling technique. The model was used to perform a parametric study, using idealized flange-to-flange connections, to compare the calculated girder distribution factors to the finite-element model–estimated girder distribution factors, and poor agreement was found (R2=0.449 and 0.237 for moment and shear, respectively). A multivariable linear regression analysis was used to develop moment and shear girder distribution factor equations for double tee bridges similar to the one investigated in this study, with a much better correlation of R2=0.86 and 0.83 for moment and shear, respectively.


  • Observations and Trends among Collapsed Bridges in New York State

    by Wesley Cook, Paul J. Barr

    A collection of condition and appraisal ratings of bridges prior to collapse is presented and analyzed to show commonalities among collapsed bridges in New York State. General observations of bridge collapses are presented in addition to select consequences. Bridge inspection data are collected for the most recent inspection dates prior to the collapse of each collapsed bridge. Trends obtained from statistical analysis of existing data show 45 (46%) of collapsed bridges were structurally deficient prior to collapse, and a collapse rate of structurally deficient bridges is estimated to be 1/1,200 annually. Age and structural deficiency are shown to be related. Structural deficiency and collapse are shown to be related. Age of structure at the time of collapse is contingent on collapse cause. Deterioration-caused and overload-caused bridge collapses are age related, but hydraulic-caused and collision-caused bridge collapses have no age-determined relationship. Fifty-seven percent of hydraulic-caused bridge collapses had a scour vulnerability rating that indicated the foundations were stable for calculated scour and scour conditions. Collision-caused bridge collapses appear to be contingent on the vertical clearance: roughly 90% of bridges analyzed had a vertical clearance less than 4.5 m (14 ft 9 in.). Overload-caused bridge collapses have a relationship with the bridge being load restricted. The overload-caused collapse rate for a bridge that is load restricted is estimated to be 1/3,500 annually. Life loss is associated with 5% of bridge collapses, most of which are collision-caused. The majority of bridge collapses have low consequences related to life loss, average daily traffic, and detour length.


  • Field Verification of Simplified Bridge Weigh-in-Motion Techniques

    by Navid Zolghadri, Marvin W. Halling, Nephi Johnson, Paul J. Barr

    This study addresses the feasibility of using a single-span bridge as a weigh-in-motion (WIM) tool to quantify the gross vehicle weights (GVWs) of trucks inexpensively with a small number of sensors and without using axle detectors. Field testing was performed on an interstate without any lane closures. Four preweighed trucks with different axle configurations traveled over a bridge at three different speeds and in two separate lanes. Measured strain data were used to implement bridge weigh-in-motion (B-WIM) algorithms and calculate the corresponding velocities and GVWs. A comparison was made between calculated and actual measured static weights, and between the calculated and specified speeds of the trucks. In addition to field testing, a finite-element (FE) model of the tested bridge was created and calibrated based on the measured strains at different locations. This calibrated FE model enabled the acquisition of the influence values for the bridge at any location (influence surface). Ten diffe...


  • Behavior of 48-Year-Old Double-Tee Bridge Girders Made with Lightweight Concrete

    by Christopher S. Pettigrew, Paul J. Barr, Marc Maguire, Marv W. Halling

    This paper describes the experimental testing of 48-year-old concrete bridge girders that were fabricated using lightweight concrete. After the bridge was decommissioned, three girders were transported to the Systems, Material, and Structural Health (SMASH) Laboratory at Utah State University (USU). The double-tee girders were tested to quantify the effective prestress, flexural capacity, and deck punching shear strength. The experimental results were compared with calculated values based on recommended procedures in the AASHTO LRFD bridge design specifications. The AASHTO refined method underestimated the loss of prestress of the three girders by an average of 17.6%. The calculated flexural capacities were overestimated by an average of 34.0% when compared with the measured values. This unconservative result is believed to be a result of the deck deterioration. The average calculated punching shear capacity was within 3.0% of the measured values. The experimental results were also compared with a...


  • Effects of Temperature Variations on Structural Vibration Properties

    by Navid Zolghadri, Marvin W. Halling, Paul J. Barr

    Modal parameters are subjected to significant changes not only by damage, but also by environmental conditions. Without quantifying environmental effects, applying vibration-based damage detection techniques may result in false damage identification. Collecting vibration and temperature data continuously have enabled researchers to investigate the correlation between environmental effects and identified modal parameters. Amid different environmental effects, temperature variations have been found to have the biggest impact on vibrational characteristics of bridges. In this paper, the effect of temperature on vibrational characteristics of a continuously monitored bridge, located in Perry, Utah, is presented. This bridge is instrumented with a monitoring system that collects vibration and temperature data at different locations of the bridge every hour. For dimensionality reduction, principle components of temperature measurements were extracted by applying principle component analysis (PCA). Natural frequencies of the structure are identified from ambient vibration data using the natural excitation technique (NExT) along with the Eigen system realization (ERA) algorithm. Variability of identified natural frequencies were investigated based on statistical properties of identified frequencies. A nonlinear ARX model and nonlinear polynomial models were used to find the relationship between the measured temperature and natural frequencies. The nonlinear ARX model showed natural frequencies are dependent to previously measured temperatures. This model was validated by using different sets of available data. These two models were evaluated and compared based on the statistical properties.


  • Open Access

    Live-Load Testing Application Using a Wireless Sensor System and Finite-Element Model Analysis of an Integral Abutment Concrete Girder Bridge

    by Robert W. Fausett, Paul J. Barr, Marvin W. Halling

    As part of an investigation on the performance of integral abutment bridges, a single-span, integral abutment, prestressed concrete girder bridge near Perry, Utah was instrumented for live-load testing. The live-load test included driving trucks at 2.24 m/s (5 mph) along predetermined load paths and measuring the corresponding strain and deflection. The measured data was used to validate a finite-element model (FEM) of the bridge. The model showed that the integral abutments were behaving as 94% of a fixed-fixed support. Live-load distribution factors were obtained using this validated model and compared to those calculated in accordance to recommended procedures provided in the AASHTO LRFD Bridge Design Specifications (2010). The results indicated that if the bridge was considered simply supported, the AASHTO LRFD Specification distribution factors were conservative (in comparison to the FEM results). These conservative distribution factors, along with the initial simply supported design assumption resulted in a very conservative bridge design. In addition, a parametric study was conducted by modifying various bridge properties of the validated bridge model, one at a time, in order to investigate the influence that individual changes in span length, deck thickness, edge distance, skew, and fixity had on live-load distribution. The results showed that the bridge properties with the largest influence on bridge live-load distribution were fixity, skew, and changes in edge distance.


  • Temperature Effects on a Box-Girder Integral-Abutment Bridge

    by Leo E. Rodriguez, Paul J. Barr, Marv W. Halling

    As part of a study to quantify temperature effects on integral-abutment box-girder bridges, field instrumentation was monitored continuously for one year on a bridge near Sacramento, California. Thermocouples were installed throughout the deck as well as over the height of the superstructure. Temperature changes were used to obtain maximum and minimum average temperatures as well as positive and negative thermal gradients. These values were compared with recommended respective temperature ranges. Strain changes at various locations were obtained by driving trucks along five load paths. These data, along with strain changes resulting from daily temperature variations, were used to validate a finite-element model using solid elements for the superstructure and springs at the abutments, in order to replicate the partial fixity of the bridge. The validated finite-element model was used to evaluate the effects that the partial fixity and temperature gradients have on the temperature stress for a typical integral-abutment bridge.


  • Statistical Models of a Concrete Bridge: Changes in Modal Parameters Due to Temperature

    by Nickolas R. Foust, Marvin W. Halling, Paul J. Barr

    Vibration-based structural health monitoring (SHM) has become a tool in evaluating the condition of civil structures. For bridge structures, vibration-based SHM systems may use the dynamic response of a bridge to measure modal parameters. A change in a structure's modal parameters may indicate damage or other changes to the structural system. These same modal parameters are also sensitive to environmental conditions, primarily temperature. Statistical models have been utilized to differentiate the modal parameter changes caused by temperature and those caused by physical changes. Statistical models also help describe the relationship between modal parameters and environmental conditions. The Lambert Road Bridge is a concrete integral abutment bridge located in California on Interstate 5 (I-5), south of Sacramento. In this study, a SHM system installed on the Lambert Road Bridge was utilized to monitor the bridge's modal parameters and temperatures. The measurements from the SHM system were used to create multiple linear regression models that helped describe the relationship between the structure's modal parameters and temperatures.


  • Comparison of Wireless and Wired Structural System Identification

    by Navid Zolghadri, Marvin W. Halling, Paul J. Barr

    Various research studies have been carried out to improve wireless structural monitoring. The improvements can be categorized into two general categories: data processing (software) and sensors technology (hardware). Advances in data processing offer new strategies for analyzing the data while novel sensor technologies mostly solve the challenges in power consumption and data transmission. These hardware challenges may also be affected by improvements in the data analyzing process which can help in reducing the quantity of data that needs to be transferred and significantly decreases the power consumption. In this study, the random decrement (RD) technique along with the Ibrahim Time Domain (ITD) method were evaluated for modal identification of structures through both wired and wireless sensors. This paper shows how smaller segments of data can be used for extracting the modal properties with similar accuracy. A simple laboratory beam test was performed to compare the data from co-located wireless and wired sensors in the time-domain. Then, the modal identification of the beam through RD and ITD method shows the comparison between wired and wireless structural identification. Additionally, this study investigates the capability of the wireless sensors in providing accurate modal parameters through different data analyzing processes and system identification techniques under actual field conditions. These techniques were used for structural identification of a bridge located in Perry, Utah. The performance and capability of these methods were evaluated and show that detecting the modal parameters of a bridge can be achieved by not transmitting the entire collected package of data.


  • Live-Load Test Comparison and Load Ratings of a Posttensioned Box Girder Bridge

    by Dereck J. Hodson, Paul J. Barr, Leonardo Pockels

    This paper presents a comparison of two live-load tests performed on a posttensioned, box-girder bridge. The initial live-load test was performed more than 20 years before the most recent test. Strain gauges were placed at the same location for both tests. In each case, the bridge was subjected to nearly identical loads so that changes in strain could be correlated as a heavy truck drove across the instrumented bridge. A comparison of the bridge behavior based on the two load tests is presented. The changes in recorded strain were also used to validate a detailed finite-element (FE) model using primarily shell elements. From this calibrated FE model, the live-load distribution factors for moment were obtained. These factors were used to calculate both the inventory and operating rating factors of the bridge. These values were compared with those calculated in accordance to the AASHTO LRFD specifications for distribution factors. It was found that the rating factors could be increased by 26% becaus...