Ahmed Sabry Farghaly
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ahmed Sabry Farghaly has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Brahim Benmokrane
University of Sherbrooke
9 shared publications - Nayera Mohamed
Department of Civil Engineering, University of Sherbrooke, Sherbrooke, QC J1K 2R1, Canada
3 shared publications - Ahmed Arafa
Civil Engineering Department, Faculty of Engineering, Sohag University, Sohag, 82524, Egypt
2 shared publications Brahim Benmokrane
Department of Civil Engineering, University of Sherbrooke, Sherbrooke, QC J1K 2R1, Canada
2 shared publicationsKenneth W. Neale
Department of Civil Engineering, University of Sherbrooke, Sherbrooke, QC J1K 2R1, Canada
2 shared publications- Ahmed Arafa
Ph.D. Candidate, Dept. of Civil Engineering, Univ. of Sherbrooke, Sherbrooke, QC, Canada J1K 2R1
1 shared publication
Latest Publications
- 27 September 2022
- Published by Springer Nature
- p. 171-178
Effect of Lateral Reinforcement Spacing on Cyclic Loaded GFRP-Reinforced Concrete Columns
- 27 September 2022
- Published by Springer Nature
- p. 171-178
Effect of Lateral Reinforcement Spacing on Cyclic Loaded GFRP-Reinforced Concrete Columns
- 27 September 2022
- Published by Springer Nature
- p. 163-170
Effect of the Axial Load Ratio on the Lateral Load Performance of GFRP-Reinforced Squat Walls
- 27 September 2022
- Published by Springer Nature
- p. 163-170
Effect of the Axial Load Ratio on the Lateral Load Performance of GFRP-Reinforced Squat Walls
- 1 August 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 22 (4)
Prediction of Flexural and Shear Strength of Concrete Squat Walls Reinforced with GFRP Bars
This paper presents an original study aimed at predicting the ultimate flexural and shear strengths of glass fiber–reinforced polymer (GFRP) RC squat walls subjected to quasi-static reversed cyclic lateral loading. Predicting the strength of GFRP-reinforced squat walls is critical for their safe design and acceptance of GFRP bar as reinforcement in such lateral-resisting structural elements. The test results of squat walls reinforced solely with GFRP bars have demonstrated their feasibility in resisting lateral loads and pointed to the necessity of adequate prediction of ultimate strength and failure modes. The predictions based on fiber-reinforced polymer (FRP) design codes and guidelines were investigated and compared with the test results of five large-scale GFRP-RC squat walls with different failure modes. The results demonstrated that in the one code, the concrete contribution to the shear resistance should be considered, and in other design guidelines, the 45° shear crack–angle assumption should be modified for squat walls with different properties and should consider the increase in concrete shear contribution after initiation of the first shear crack. The confinement at boundary elements has been shown to improve significantly the ultimate flexural strength that should be integrated in the design.
- 1 August 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 22 (4)
Prediction of Flexural and Shear Strength of Concrete Squat Walls Reinforced with GFRP Bars
This paper presents an original study aimed at predicting the ultimate flexural and shear strengths of glass fiber–reinforced polymer (GFRP) RC squat walls subjected to quasi-static reversed cyclic lateral loading. Predicting the strength of GFRP-reinforced squat walls is critical for their safe design and acceptance of GFRP bar as reinforcement in such lateral-resisting structural elements. The test results of squat walls reinforced solely with GFRP bars have demonstrated their feasibility in resisting lateral loads and pointed to the necessity of adequate prediction of ultimate strength and failure modes. The predictions based on fiber-reinforced polymer (FRP) design codes and guidelines were investigated and compared with the test results of five large-scale GFRP-RC squat walls with different failure modes. The results demonstrated that in the one code, the concrete contribution to the shear resistance should be considered, and in other design guidelines, the 45° shear crack–angle assumption should be modified for squat walls with different properties and should consider the increase in concrete shear contribution after initiation of the first shear crack. The confinement at boundary elements has been shown to improve significantly the ultimate flexural strength that should be integrated in the design.
- 1 April 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 22 (2)
Experimental Behavior of GFRP-Reinforced Concrete Squat Walls Subjected to Simulated Earthquake Load
This study addressed the feasibility of reinforced-concrete squat walls totally reinforced with glass fiber-reinforced polymer (GFRP) bars achieving the strength and drift requirements specified in various codes. Using noncorrodible GFRP bars represents an effective method for overcoming deterioration due to corrosion problems. The previous experimental studies on GFRP-reinforced midrise shear walls showed that GFRP reinforcement can control shear deformation, which is a major problem in steel-reinforced squat walls. Five full-scale concrete squat walls with an aspect ratio (height to length ratio) of 1.3, one reinforced with steel bars (as a reference specimen) and four totally reinforced with GFRP bars, were constructed and tested to failure under quasi-static reversed cyclic lateral loading. The reported test results clearly show that properly designed and detailed GFRP-reinforced concrete squat walls can reach high deformation levels with no strength degradation. The results also show that the achieved drift satisfies the limitation in most building codes. Acceptable levels of energy dissipation, compared to the steel-reinforced squat wall, were observed. The promising results can provide impetus for constructing concrete walls reinforced with GFRP and constitute a step toward using GFRP reinforcement in such lateral-resisting systems.
- 1 April 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 22 (2)
Experimental Behavior of GFRP-Reinforced Concrete Squat Walls Subjected to Simulated Earthquake Load
This study addressed the feasibility of reinforced-concrete squat walls totally reinforced with glass fiber-reinforced polymer (GFRP) bars achieving the strength and drift requirements specified in various codes. Using noncorrodible GFRP bars represents an effective method for overcoming deterioration due to corrosion problems. The previous experimental studies on GFRP-reinforced midrise shear walls showed that GFRP reinforcement can control shear deformation, which is a major problem in steel-reinforced squat walls. Five full-scale concrete squat walls with an aspect ratio (height to length ratio) of 1.3, one reinforced with steel bars (as a reference specimen) and four totally reinforced with GFRP bars, were constructed and tested to failure under quasi-static reversed cyclic lateral loading. The reported test results clearly show that properly designed and detailed GFRP-reinforced concrete squat walls can reach high deformation levels with no strength degradation. The results also show that the achieved drift satisfies the limitation in most building codes. Acceptable levels of energy dissipation, compared to the steel-reinforced squat wall, were observed. The promising results can provide impetus for constructing concrete walls reinforced with GFRP and constitute a step toward using GFRP reinforcement in such lateral-resisting systems.
- 1 August 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 143 (8)
Effect of Vertical and Horizontal Web Reinforcement on the Strength and Deformation of Concrete Deep Beams Reinforced with GFRP Bars
Ten full-scale concrete deep beams reinforced with glass fiber-reinforced polymer (GFRP) with a cross section of were tested to failure under two-point loading. The test variables were the configuration of web reinforcement (horizontal and/or vertical) and shear span-to-depth ratio ( , 1.13, and 0.83). All specimens exhibited sufficient deformation required to develop arch action, which was confirmed by crack propagation and an almost linear strain profile in the main longitudinal reinforcement, in addition to the typical failure mode of crushing in the concrete diagonal strut. The results show that the vertical web reinforcement had no clear impact on ultimate capacity, while the configuration with horizontal-only web reinforcement unexpectedly resulted in a lower ultimate capacity compared to the specimens without web reinforcement. The web reinforcement’s main contribution was significant crack-width control.- 1 August 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 143 (8)
Effect of Vertical and Horizontal Web Reinforcement on the Strength and Deformation of Concrete Deep Beams Reinforced with GFRP Bars
Ten full-scale concrete deep beams reinforced with glass fiber-reinforced polymer (GFRP) with a cross section of were tested to failure under two-point loading. The test variables were the configuration of web reinforcement (horizontal and/or vertical) and shear span-to-depth ratio ( , 1.13, and 0.83). All specimens exhibited sufficient deformation required to develop arch action, which was confirmed by crack propagation and an almost linear strain profile in the main longitudinal reinforcement, in addition to the typical failure mode of crushing in the concrete diagonal strut. The results show that the vertical web reinforcement had no clear impact on ultimate capacity, while the configuration with horizontal-only web reinforcement unexpectedly resulted in a lower ultimate capacity compared to the specimens without web reinforcement. The web reinforcement’s main contribution was significant crack-width control.- 1 February 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 21 (1)
Beam-Testing Method for Assessment of Bond Performance of FRP Bars in Concrete under Tension–Compression Reversed Cyclic Loading
This paper presents a novel beam-testing method to assess the bond performance of fiber-reinforced polymer (FRP) bars in reinforced-concrete resisting systems subjected to tension–compression reversed cyclic loading. Special attention was paid to ensuring the stability of the proposed test setup, limiting all unwanted forces generated in the system and allowing for the application of tension and compression forces to the FRP bar without premature bar buckling. Preliminary test results are presented specifically for the cyclic bond stress-slip relationship under different loading conditions—tension–tension and tension–compression cyclic loading—in addition to the monotonic-tension loading to assess the suitability of the novel testing method.
- 1 February 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 21 (1)
Beam-Testing Method for Assessment of Bond Performance of FRP Bars in Concrete under Tension–Compression Reversed Cyclic Loading
This paper presents a novel beam-testing method to assess the bond performance of fiber-reinforced polymer (FRP) bars in reinforced-concrete resisting systems subjected to tension–compression reversed cyclic loading. Special attention was paid to ensuring the stability of the proposed test setup, limiting all unwanted forces generated in the system and allowing for the application of tension and compression forces to the FRP bar without premature bar buckling. Preliminary test results are presented specifically for the cyclic bond stress-slip relationship under different loading conditions—tension–tension and tension–compression cyclic loading—in addition to the monotonic-tension loading to assess the suitability of the novel testing method.
- 1 November 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 21 (11)
Laboratory Testing of GFRP-RC Panels with UHPFRC Joints of the Nipigon River Cable-Stayed Bridge in Northwest Ontario, Canada
This study investigates the behavior of ultrahigh-performance fiber-reinforced concrete (UHPFRC) joints between precast concrete panels reinforced with glass-fiber-reinforced polymer (GFRP) bars that are being used in the first cable-stayed bridge in northwest Ontario, Canada (Nipigon, Nipigon River Bridge). The test panels, which simulated the deck panels of the Nipigon River Bridge, were fabricated at the same precast facility in Ontario and delivered to the University of Sherbrooke for flexural testing until failure. The test matrix included eight panels measuring 3,000 mm long × 1,000 mm wide × 220 mm thick. The tests included three reference specimens without structural joints (one reinforced with steel bars and two reinforced with GFRP bars) and five jointed specimens (one reinforced with steel bars and four reinforced with GFRP bars). The structural joint width was a constant 220 mm for all jointed specimens. The specimens were tested in a cantilever-panel setup with the UHPFRC joint subjec...
- 1 November 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 21 (11)
Laboratory Testing of GFRP-RC Panels with UHPFRC Joints of the Nipigon River Cable-Stayed Bridge in Northwest Ontario, Canada
This study investigates the behavior of ultrahigh-performance fiber-reinforced concrete (UHPFRC) joints between precast concrete panels reinforced with glass-fiber-reinforced polymer (GFRP) bars that are being used in the first cable-stayed bridge in northwest Ontario, Canada (Nipigon, Nipigon River Bridge). The test panels, which simulated the deck panels of the Nipigon River Bridge, were fabricated at the same precast facility in Ontario and delivered to the University of Sherbrooke for flexural testing until failure. The test matrix included eight panels measuring 3,000 mm long × 1,000 mm wide × 220 mm thick. The tests included three reference specimens without structural joints (one reinforced with steel bars and two reinforced with GFRP bars) and five jointed specimens (one reinforced with steel bars and four reinforced with GFRP bars). The structural joint width was a constant 220 mm for all jointed specimens. The specimens were tested in a cantilever-panel setup with the UHPFRC joint subjec...
- 1 December 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 17 (6)
Shear Behavior of FRP-Reinforced Concrete Deep Beams without Web Reinforcement
The shear behavior of four full-scale deep beams reinforced with carbon and glass fiber reinforced polymer (FRP) bars were investigated. The beams were supported over a 3,000-mm span with a projection of 1,000 mm on each side, with a cross section of 300 mm in width and 1,200 mm in depth, and tested to failure under four-point loading. The primary test variables included the longitudinal reinforcement ratio and the reinforcement type. The reinforcement ratio and concrete compressive strength had a clear effect on the ultimate capacity and deflection characteristics while reinforcement type no clear effect of the behavior of the tested beams. The crack patterns, mode of failure, and strains in concrete and reinforcement were also reported. The formation of the tie action was confirmed by the nearly uniform strain distribution in the longitudinal reinforcement. The results are compared to the strut-and-tie model, demonstrating the necessity of including the effect of web reinforcement and the import...
- 1 December 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 17 (6)
Shear Behavior of FRP-Reinforced Concrete Deep Beams without Web Reinforcement
The shear behavior of four full-scale deep beams reinforced with carbon and glass fiber reinforced polymer (FRP) bars were investigated. The beams were supported over a 3,000-mm span with a projection of 1,000 mm on each side, with a cross section of 300 mm in width and 1,200 mm in depth, and tested to failure under four-point loading. The primary test variables included the longitudinal reinforcement ratio and the reinforcement type. The reinforcement ratio and concrete compressive strength had a clear effect on the ultimate capacity and deflection characteristics while reinforcement type no clear effect of the behavior of the tested beams. The crack patterns, mode of failure, and strains in concrete and reinforcement were also reported. The formation of the tie action was confirmed by the nearly uniform strain distribution in the longitudinal reinforcement. The results are compared to the strut-and-tie model, demonstrating the necessity of including the effect of web reinforcement and the import...
- Retraction
- 1 November 2013
- Published by Canadian Science Publishing in Canadian Journal of Civil Engineering
- Vol. 40 (11) , 1150
Retraction: Cyclic-load behavior of GFRP-reinforced concrete shear walls
- 1 November 2013
- Published by Canadian Science Publishing in Canadian Journal of Civil Engineering
- Vol. 40 (11) , 1150
RetractionRetraction: Cyclic-load behavior of GFRP-reinforced concrete shear walls
- Retracted
- 1 November 2013
- Published by Canadian Science Publishing in Canadian Journal of Civil Engineering
- Vol. 40 (11)
Cyclic Load Behavior of GFRP-Reinforced Concrete Shear Walls
- 1 November 2013
- Published by Canadian Science Publishing in Canadian Journal of Civil Engineering
- Vol. 40 (11)
RetractedCyclic Load Behavior of GFRP-Reinforced Concrete Shear Walls