ATAditya Tyagi

Aditya Tyagi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Aditya Tyagi has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Probable Role of Anthropogenic Activities in 2013 Flood Disaster in Uttarakhand, India

    by Mitthan Lal Kansal, Sandeep Shukla, Aditya Tyagi

    Uttarakhand is a somewhat new Himalayan state of Northern India established in the year 2000. It is inherently vulnerable to various natural and human-induced disasters. During June 16-17, 2013, a devastating flood followed by large-scale landslides occurred in this state, which is termed as the country's worst disaster since the 2004 tsunami. The maximum damage was in the Kedarnath Valley, which is one of the four abodes/seats of Hindu pilgrimage circuit (Chota Char Dham)—Yamunotri-Gangotri-Kedarnath-Badrinath—in the Indian Himalayas. Every year, millions of people from various parts of the country/world visit this spiritual shrine. All these spiritual shrines are up in the Himalayas located at an elevation of more than 3,000 m above the mean sea level and have tough terrain with a single land route. A multiday cloudburst followed by heavy rainfall events, landslides, glacier movements, and breaching of a glacial lake aggravated the impact of this disaster in the region. The present study briefly describes this disaster and tries to identify the possible causes of such a huge loss of human life and property and its occurrence. It is felt that increase in anthropogenic activities such as construction of hydropower projects, ever-increasing tourism, urbanization, and increased emission of green house gases (GHGs) during the last few years have directly and indirectly contributed to the occurrence of this disaster. These anthropogenic activities have resulted in frequent and extreme magnitude of rainfall, cloud bursting, rapid melting of snow and ice, sudden release of water stored in glaciers, landslides, and failure of water storage structures such as dams and levees.


  • Challenges of Sustainable Development and Management of Water Resources in Ethiopia

    by Mitthan Lal Kansal, Dereje Adeba, Aditya Tyagi

    The occurrence of water in Ethiopia is highly variable. Its accessibility and suitability varies from region to region. The average annual precipitation in the country is about 850 mm, which is unevenly distributed, making some regions water-deficit and others water-surplus regions. Ethiopia has 12 river basins. About 123 BCM runoff is generated annually from its 10 river basins while the remaining two basins are dry. The ground water potential is estimated to be 36 BCM. The dome-shaped topographic nature of Ethiopia favors the flow of rivers to neighboring countries. Water shortage is deeply rooted in the country, but it does not stem from the absolute lack of water resources, instead, from the lack of water sector development due to inadequacy and incompetency of institutional arrangements, poor management, underutilization of available water resources, and legal frameworks in the management and governance of water. Stakeholder participation is poor in the implementation and management of the projects, and project costs are not recovered in most cases. The country has the lowest reservoir storage facility, and at a national level coverage of access to safe drinking water is low. There are few or no water-saving practices. Water management policy of Ethiopia states that water allocation between different sectors should not be made on a permanent basis, which creates a loophole for drought-affected areas to be at risk during the dry period. This paper discusses the possible ways to avert the risk of drought or decreasing vulnerability and maximizing sustainable economic growth through successful implementation of water management policies, strategies, and project management by the beneficiaries. It identifies the surplus and deficit river basins and highlights the possibilities of interbasin water transfer as an option for equitable distribution of water resources.


  • Augmentation Strategies for Sustainable Water Supply to Shimla - A Hill Station in India

    by S. K. Sharma, M. L. Kansal, Aditya Tyagi

    Water supply for Shimla, a popular hill station in the northern part of India, was initially planned and executed by the Britishers in the year 1875 for a meager population of 16,000. Over the years, the city has grown both geographically and demographically, and water demand increased manyfold. From 1875 to date, the Shimla water supply system has expanded into seven independent water supply schemes originating from Dhalli Catchment, Cherot Nallah, Chair Nallah, Nauti Khad-I, Ashwani Khad, Nauti khad-II, and Giri River. Total water demand (2012) is 64.66 million liters per day (MLD) against source supply of 54.54 MLD. The gap between demand and supply further increases with system inefficiencies, as a result there are consumers who are getting water supply only for about 45 minutes in a day. The present deficit of 10.12 MLD (2012) will further amplify to 21.27 MLD in 2021and 42.61 MLD in 2031. Domestic water demand (2012) is 35.17 MLD (12.84 billion liters per annum) whereas if 30% of the rainfall is harvested in built-up areas (1475.76 hectares), 19.12 MLD (6.98 billion liters) of rainfall can be harvested annually, equivalent to 54% of domestic water demand. The capacity of six existing sewage treatment plants is 35.63 MLD, and effluent can partly be reused after treatment for nonpotable consumption. To fulfill the growing water demand of Shimla, the available options are (i) gravitating water from upper reach of River Pabbar, (ii) lifting water from River Satluj, and (iii) rainwater harvesting and reuse of waste water coupled with balance additional water from River Satluj or Pabbar. In this study issues and challenges of water supply in Shimla, reasons for water deficit, and in-depth analysis of future demand and supply are discussed. Further, feasible augmentation strategies, role of rainwater harvesting, and reuse of waste water for mitigating the water scarcity have been critically examined for the sustainable water supply to Shimla city.


  • Identification of Optimal Monitoring Locations to Detect Accidental Contaminations

    by M. L. Kansal, Tandin Dorji, Surendra Kumar Chandniha, Aditya Tyagi

    Water quality may get deteriorated in the distribution network due to natural, man-made, and/or accidental reasons. In order to ensure safe water delivery to the consumers, water quality monitoring in a distribution system is essential. In order to obtain reliable water quality information, monitoring would be required at all nodes of a given distribution system, which is practically may not be infeasible due to economic and time constraints. Thus, it is desired to design a monitoring network for specific levels of service and reliability. The level of service can be defined in terms of the contaminated water consumed or the time lapse between the entry and detection of external contaminants. These service levels are termed as the "volume consumption level of service" and "T hour level of service" respectively. The monitoring network can be identified such that the required level of service can be achieved with minimum number of monitoring locations. In this study, a methodology for identifying the optimal monitoring locations has been suggested using a desired level of service. The developed methodology has been applied to an urban water distribution network to identify the source of accidental contamination. This methodology can be useful to give an alarm signal within a level of service for a potential contamination in a water distribution system.


  • Threat Perceptions and Risk Management in Urban Water Supply Schemes

    by Mitthan Lal Kansal, Aditya Tyagi

    The objective of an urban water supply scheme (UWSS) is to provide safe and adequate drinking water to the public on sustainable basis. Most of these WSSs are vulnerable to natural hazards like earthquake, cyclone, landslides, and excessive rainfall etc., and the willful physical, chemical, biological, and cyber attacks. While the risk due to natural catastrophes remains high, the risk due to man-made disasters has also been increasing during the last few decades. Almost every nation is facing the problem of terrorism, as it is impossible to satisfy all sections of society within a state, a country, or a group of countries at global level. In order to express their dis-satisfaction and anguish, the disillusioned individuals or group of individuals indulge in the terrorist activities targeting the infrastructures so as to create panic among larger section. The events like September 11, 2001, attack on Indian Parliament, religious places, and recent attack of November 26, 2008 in Mumbai (India), and consistent threats of use of chemical & biological weapons in various parts of the world has compelled the researchers and managers to plan the operation and management of water supply schemes from a different perspective as it is one of the most important infrastructure for the sustenance of society. Precautions are required against the physical, chemical, biological, and cyber attacks on water supply systems.


  • Improved Method for Aggregation of Water Quality Subindices

    by Prabhata K. Swamee, Aditya Tyagi

    Alternative methods to describe water quality using an aggregate index consisting of subindices for individual water quality variables are examined. Most aggregation methods suffer from three shortcomings: Ambiguity, eclipsing, and rigidity. Ambiguity problems exist when all the subindices indicate acceptable water quality for a given use, but the aggregated index does not. Eclipsing problems exist when the aggregated index fails to reflect poor water quality of one or more water quality variables. Rigidity problems exist when additional variables are included in the index to address specific water quality concerns, but the faulty aggregation function might artificially reduce the value of the water quality index such that it does not accurately reflect the true water quality. As the number of water quality variables increases, the magnitude of the aggregated index decreases raising the issue of ambiguity again. The writers developed a mathematical formulation for aggregate indices that avoids the problem...


  • Design of Class-I Sedimentation Tanks

    by Prabhata K. Swamee, Aditya Tyagi

    The present practice for the design of primary settling tanks is based on the overflow rate corresponding to the percentage removal using isoremoval plots. The design procedure would be more rational if it were based on the removal efficiency and the scour criterion of the deposited particles. This technical note presents closed-form equations for the removal efficiency and scour velocity of particles. The removal efficiency equation considers the size distribution of particles, and the scour velocity equation is based on the Rouse equation. The removal efficiency equation yields the minimum particle size completely removed by the sedimentation tank. Using these equations the design equations have been obtained for the length and width of the settling tank. Besides other parameters, the design equations involve the completely removed minimum particle size, the specific gravity of the sediment particles, and the kinematic viscosity of water. These equations will be useful for the design of grit chambers and settling basins undergoing class-I settling.