Ernest Naesgaard
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ernest Naesgaard has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Ali Amini
Naesgaard Geotechnical Ltd., RR1 Site I-38, Bowen Island, BC, V0N 1G0
1 shared publication - Bengt H. Fellenius
2475 Rothesay Ave, Sidney, BC V8L 2B9, Canada
1 shared publication Dharma Wijewickreme
Ph.D. Candidate, Dept. of Civil Engineering, Univ. of British Columbia, Vancouver BC, Canada V0N 1G0
1 shared publicationPeter M. Byrne
Ph.D. Candidate, Dept. of Civil Engineering, Univ. of British Columbia, Vancouver BC, Canada V0N 1G0
1 shared publication- Uthaya M. Uthayakumar
Naesgaard Geotechnical Ltd., RR1 Site I-38, Bowen Island, BC, V0N 1G0
1 shared publication
Latest Publications
- 29 March 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 404-421
Long Piles in Thick Lacustrine and Deltaic Deposits: Two Bridge Foundation Case Histories
Two recent bridge projects in British Columbia highlight the importance of having well-instrumented pile loading tests as part of pile foundation design. First case is the 1.5 km long, five-lane W.R. Bennett Bridge in the challenging Okanagan Lake soil profile with soft and loose to medium dense silts and silty sands to depths over 100 m. Five 610-mm diameter open- and closed-toe test piles were driven to 45 m depth. Pile dynamics tests were performed for all five test piles and a static loading test was carried out on the center pile, driven closed-toe. The importance of considering residual load in the test interpretation is illustrated. Second case is the 2.6 km long (main bridge and approaches) six-lane, cable-stayed Golden Ears Bridge over the Fraser River delta. Soils consisted of thick, potentially liquefiable sands, overlying near-normally consolidated soft to stiff clayey silts and silty clays to over 120 m depth. The south approach and main span piers are founded on 2.5 m diameter bored piles of up to 85 m length. Four loading tests were carried out for this project. One of the tests, a 74 m deep 2.5 m diameter pile loaded with bi-directional O-cells is described and the test results, their interpretation, and general foundation design methods and considerations are presented.
- 29 March 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 404-421
Long Piles in Thick Lacustrine and Deltaic Deposits: Two Bridge Foundation Case Histories
Two recent bridge projects in British Columbia highlight the importance of having well-instrumented pile loading tests as part of pile foundation design. First case is the 1.5 km long, five-lane W.R. Bennett Bridge in the challenging Okanagan Lake soil profile with soft and loose to medium dense silts and silty sands to depths over 100 m. Five 610-mm diameter open- and closed-toe test piles were driven to 45 m depth. Pile dynamics tests were performed for all five test piles and a static loading test was carried out on the center pile, driven closed-toe. The importance of considering residual load in the test interpretation is illustrated. Second case is the 2.6 km long (main bridge and approaches) six-lane, cable-stayed Golden Ears Bridge over the Fraser River delta. Soils consisted of thick, potentially liquefiable sands, overlying near-normally consolidated soft to stiff clayey silts and silty clays to over 120 m depth. The south approach and main span piers are founded on 2.5 m diameter bored piles of up to 85 m length. Four loading tests were carried out for this project. One of the tests, a 74 m deep 2.5 m diameter pile loaded with bi-directional O-cells is described and the test results, their interpretation, and general foundation design methods and considerations are presented.
- 1 November 2007
- Published by American Society of Civil Engineers (ASCE) in International Journal of Geomechanics
- Vol. 7 (6) , 437-443
Is P-Wave Velocity an Indicator of Saturation in Sand with Viscous Pore Fluid?
It is commonly assumed that within inundated sand the Skempton B value and P-wave velocity decrease with decrease in saturation. In centrifuge tests a common saturation procedure is to inundate the specimen with carbon dioxide while under a vacuum and then slowly introduce the viscous pore fluid. The B value and related saturation is difficult to measure in centrifuge models and P-wave velocity—saturation correlations have been used for this purpose. A laboratory emulation of centrifuge saturation procedures was made using a triaxial cell with top and bottom bender elements and a viscous methyl cellulose–water pore fluid. Contrary to expectations, the laboratory tests showed high P-wave velocities indicative of full saturation when B values were low. Numerical modeling of the laboratory tests indicated that if air bubbles within the pore fluid are numerous and closely spaced then there is a good correlation between saturation, B value, and P-wave velocity. However if the air bubbles are larger and only pr...
- 1 November 2007
- Published by American Society of Civil Engineers (ASCE) in International Journal of Geomechanics
- Vol. 7 (6) , 437-443
Is P-Wave Velocity an Indicator of Saturation in Sand with Viscous Pore Fluid?
It is commonly assumed that within inundated sand the Skempton B value and P-wave velocity decrease with decrease in saturation. In centrifuge tests a common saturation procedure is to inundate the specimen with carbon dioxide while under a vacuum and then slowly introduce the viscous pore fluid. The B value and related saturation is difficult to measure in centrifuge models and P-wave velocity—saturation correlations have been used for this purpose. A laboratory emulation of centrifuge saturation procedures was made using a triaxial cell with top and bottom bender elements and a viscous methyl cellulose–water pore fluid. Contrary to expectations, the laboratory tests showed high P-wave velocities indicative of full saturation when B values were low. Numerical modeling of the laboratory tests indicated that if air bubbles within the pore fluid are numerous and closely spaced then there is a good correlation between saturation, B value, and P-wave velocity. However if the air bubbles are larger and only pr...