Daniel Pajek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Daniel Pajek has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Kullervo Hynynen
Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada
3 shared publications- Kullervo Hynynen
Sunnybrook Research Institute
2 shared publications - Alec Hughes
Dept. of Medical Biophys., Univ. of Toronto, 101 College St., Rm. 15-701, Toronto, ON M5G 1L7, Canada
1 shared publication Alison Burgess
Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Canada
1 shared publication- Alison Burgess
Physical Sciences, Sunnybrook Research Institute, 2075 Bayview Ave, S665, Toronto, ON M4N 3M5, Canada
1 shared publication Meaghan M. O’reilly
Physical Sci. Platform, Sunnybrook Res. Inst., Toronto, ON, Canada
1 shared publication
Latest Publications
- 1 September 2014
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 40 (9) , 2151-2161
High-Intensity Focused Ultrasound Sonothrombolysis: The Use of Perfluorocarbon Droplets to Achieve Clot Lysis at Reduced Acoustic Power
- 1 September 2014
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 40 (9) , 2151-2161
High-Intensity Focused Ultrasound Sonothrombolysis: The Use of Perfluorocarbon Droplets to Achieve Clot Lysis at Reduced Acoustic Power
- Open Access
- 19 November 2013
- Published by Wiley in Medical Physics
- Vol. 40 (12) , 122901
The application of sparse arrays in high frequency transcranial focused ultrasound therapy: A simulation study
Purpose:: Transcranial focused ultrasound is an emerging therapeutic modality that can be used to perform noninvasive neurosurgical procedures. The current clinical transcranial phased array operates at 650 kHz, however the development of a higher frequency array would enable more precision, while reducing the risk of standing waves. However, the smaller wavelength and the skullˈs increased distortion at this frequency are problematic. It would require an order of magnitude more elements to create such an array. Random sparse arrays enable steering of a therapeutic array with fewer elements. However, the tradeoffs inherent in the use of sparsity in a transcranial phased array have not been systematically investigated and so the objective of this simulation study is to investigate the effect of sparsity on transcranial arrays at a frequency of 1.5 MHz that provides small focal spots for precise exposure control.Methods:: Transcranial sonication simulations were conducted using a multilayer Rayleigh‐Sommerfeld propagation model. Element size and element population were varied and the phased arrayˈs ability to steer was assessed.Results:: The focal pressures decreased proportionally as elements were removed. However, off‐focus hotspots were generated if a high degree of steering was attempted with very sparse arrays. A phased array consisting of 1588 elements 3 mm in size, a 10% population, was appropriate for steering up to 4 cm in all directions. However, a higher element population would be required if near‐skull sonication is desired.Conclusions:: This study demonstrated that the development of a sparse, hemispherical array at 1.5 MHz could enable more precision in therapies that utilize lower intensity sonications.
- 19 November 2013
- Published by Wiley in Medical Physics
- Vol. 40 (12) , 122901
Open AccessThe application of sparse arrays in high frequency transcranial focused ultrasound therapy: A simulation study
Purpose:: Transcranial focused ultrasound is an emerging therapeutic modality that can be used to perform noninvasive neurosurgical procedures. The current clinical transcranial phased array operates at 650 kHz, however the development of a higher frequency array would enable more precision, while reducing the risk of standing waves. However, the smaller wavelength and the skullˈs increased distortion at this frequency are problematic. It would require an order of magnitude more elements to create such an array. Random sparse arrays enable steering of a therapeutic array with fewer elements. However, the tradeoffs inherent in the use of sparsity in a transcranial phased array have not been systematically investigated and so the objective of this simulation study is to investigate the effect of sparsity on transcranial arrays at a frequency of 1.5 MHz that provides small focal spots for precise exposure control.Methods:: Transcranial sonication simulations were conducted using a multilayer Rayleigh‐Sommerfeld propagation model. Element size and element population were varied and the phased arrayˈs ability to steer was assessed.Results:: The focal pressures decreased proportionally as elements were removed. However, off‐focus hotspots were generated if a high degree of steering was attempted with very sparse arrays. A phased array consisting of 1588 elements 3 mm in size, a 10% population, was appropriate for steering up to 4 cm in all directions. However, a higher element population would be required if near‐skull sonication is desired.Conclusions:: This study demonstrated that the development of a sparse, hemispherical array at 1.5 MHz could enable more precision in therapies that utilize lower intensity sonications.
- 1 November 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (5_Suppleme) , 4088
Advances in ultrasound methods for therapy
- 1 November 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (5_Suppleme) , 4088
Advances in ultrasound methods for therapy
- 17 July 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (15) , 4951-4968
The design of a focused ultrasound transducer array for the treatment of stroke: a simulation study
High intensity focused ultrasound (HIFU) is capable of mechanically disintegrating blood clots at high pressures. Safe thrombolysis may require frequencies higher than those currently utilized by transcranial HIFU. Since the attenuation and focal distortion of ultrasound in bone increases at higher frequencies, resulting focal pressures are diminished. This study investigated the feasibility of using transcranial HIFU for the non-invasive treatment of ischemic stroke. The use of large aperture, 1.1-1.5 MHz phased arrays in targeting four clinically relevant vessel locations was simulated. Resulting focal sizes decreased with frequency, producing a maximum -3 dB depth of field and lateral width of 2.0 and 1.2 mm, respectively. Mean focal gains above an order of magnitude were observed in three of four targets and transducer intensities required to achieve thrombolysis were determined. Required transducer element counts are about an order of magnitude higher than what currently exists and so, although technically feasible, new arrays would need to be developed to realize this as a treatment modality for stroke.
- 17 July 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (15) , 4951-4968
The design of a focused ultrasound transducer array for the treatment of stroke: a simulation study
High intensity focused ultrasound (HIFU) is capable of mechanically disintegrating blood clots at high pressures. Safe thrombolysis may require frequencies higher than those currently utilized by transcranial HIFU. Since the attenuation and focal distortion of ultrasound in bone increases at higher frequencies, resulting focal pressures are diminished. This study investigated the feasibility of using transcranial HIFU for the non-invasive treatment of ischemic stroke. The use of large aperture, 1.1-1.5 MHz phased arrays in targeting four clinically relevant vessel locations was simulated. Resulting focal sizes decreased with frequency, producing a maximum -3 dB depth of field and lateral width of 2.0 and 1.2 mm, respectively. Mean focal gains above an order of magnitude were observed in three of four targets and transducer intensities required to achieve thrombolysis were determined. Required transducer element counts are about an order of magnitude higher than what currently exists and so, although technically feasible, new arrays would need to be developed to realize this as a treatment modality for stroke.
- 1 January 2012
- Published by Acoustical Society of America (ASA) in Acoustics Today
- Vol. 8 (4)
Applications of Transcranial Focused Ultrasound Surgery
- 1 January 2012
- Published by Acoustical Society of America (ASA) in Acoustics Today
- Vol. 8 (4)
Applications of Transcranial Focused Ultrasound Surgery