Per Wretenberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Per Wretenberg has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- André Stark
B Department of Clinical Sciences , Danderyd Hospital, Karolinska Institutet , Stockholm
1 shared publication Anne Ericson
Department of Orthopaedics, Karolinska University Hospital, 76 Stockholm, Sweden
1 shared publicationArne Lundberg
1 shared publication- Carl-Olav Stiller
Department of Medicine, Karolinska Institutet, Clinical Pharmacology Unit, Karolinska University Hospital, Solna, Stockholm, Sweden
1 shared publication Christina Olofsson
1 shared publicationErs Hugo
Department of Molecular Medicine and Surgery, Section of Orthopedics and Sports Medicine, Karolinska Institute, Stockholm, Sweden
1 shared publication
Latest Publications
- Open Access
- 19 November 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 384
Validation of reoperations due to infection in the Swedish Hip Arthroplasty Register
Complete or almost complete recording of reoperations is essential to enable a correct interpretation of data in arthroplasty registers. The completeness of recordings due to infection is unknown in the Swedish Hip Arthroplasty Register (SHAR). We therefore used a combination of data from the Swedish Prescribed Drug Register (SPDR) and studies of medical records to validate the data of reoperations due to infection in the SHAR. All patients registered for a primary Total Hip Replacement (THR) in the SHAR between July 1, 2005 and December 31, 2008 were selected for the study (45,531 patients with 49,219 THRs) and were matched with the SPDR. All patients with a minimum of 4 weeks of continuous outpatient antibiotic treatment within 2 years after their primary THR (1,989 patients, with 2,219 THRs) were selected for a medical records review to find the THRs reoperated due to infection. 599 (1.3%) of the THRs had been reoperated within 2 years after the index operation and in 47.4% of these the prosthesis had been revised or extracted. 400 of the THRs were registered for a reoperation in the SHAR resulting in a completeness of 67%. The completeness of registration due to early infection after THR questions whether the SHAR reoperation data can be used in order to evaluate changes in postoperative infection rates.
- 19 November 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 384
Open AccessValidation of reoperations due to infection in the Swedish Hip Arthroplasty Register
Complete or almost complete recording of reoperations is essential to enable a correct interpretation of data in arthroplasty registers. The completeness of recordings due to infection is unknown in the Swedish Hip Arthroplasty Register (SHAR). We therefore used a combination of data from the Swedish Prescribed Drug Register (SPDR) and studies of medical records to validate the data of reoperations due to infection in the SHAR. All patients registered for a primary Total Hip Replacement (THR) in the SHAR between July 1, 2005 and December 31, 2008 were selected for the study (45,531 patients with 49,219 THRs) and were matched with the SPDR. All patients with a minimum of 4 weeks of continuous outpatient antibiotic treatment within 2 years after their primary THR (1,989 patients, with 2,219 THRs) were selected for a medical records review to find the THRs reoperated due to infection. 599 (1.3%) of the THRs had been reoperated within 2 years after the index operation and in 47.4% of these the prosthesis had been revised or extracted. 400 of the THRs were registered for a reoperation in the SHAR resulting in a completeness of 67%. The completeness of registration due to early infection after THR questions whether the SHAR reoperation data can be used in order to evaluate changes in postoperative infection rates.
- Open Access
- 11 May 2011
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 82 (4) , 441-447
Pain control after total knee arthroplasty: a randomized trial comparing local infiltration anesthesia and continuous femoral block
Pain after total knee arthroplasty (TKA) is usually severe, and epidural analgesia or femoral nerve block has been considered to be an effective pain treatment. Recently, local infiltration analgesia (LIA) has become increasingly popular but the outcome of this method regarding the analgesic effect has not been fully evaluated. We compared local infiltration analgesia and femoral block with regard to analgesia and morphine demand during the first 24 h after TKA. 40 patients undergoing TKA under spinal anesthesia were randomized to receive femoral nerve block (group F) or peri- and intraarticular infiltration analgesia (group LIA) with a mixture containing ropivacaine, ketorolac, and epinephrine. All patients had access to intravenous patient-controlled analgesia (PCA) with morphine postoperatively. Pain intensity at rest and upon movement was assessed on a numeric rating scale (0-10) on an hourly basis over 24 h if the patients were awake. The average pain at rest was marginally lower with LIA (1.6) than with femoral block (2.2). Total morphine consumption per kg was similar between the 2 groups. Ancillary analysis revealed that 1 of 20 patients in the LIA group reported a pain intensity of > 7 upon movement, as compared to 7 out of 19 in the femoral block group (p = 0.04). Both LIA and femoral block provide good analgesia after TKA. LIA may be considered to be superior to femoral block since it is cheaper and easier to perform.
- 11 May 2011
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 82 (4) , 441-447
Open AccessPain control after total knee arthroplasty: a randomized trial comparing local infiltration anesthesia and continuous femoral block
Pain after total knee arthroplasty (TKA) is usually severe, and epidural analgesia or femoral nerve block has been considered to be an effective pain treatment. Recently, local infiltration analgesia (LIA) has become increasingly popular but the outcome of this method regarding the analgesic effect has not been fully evaluated. We compared local infiltration analgesia and femoral block with regard to analgesia and morphine demand during the first 24 h after TKA. 40 patients undergoing TKA under spinal anesthesia were randomized to receive femoral nerve block (group F) or peri- and intraarticular infiltration analgesia (group LIA) with a mixture containing ropivacaine, ketorolac, and epinephrine. All patients had access to intravenous patient-controlled analgesia (PCA) with morphine postoperatively. Pain intensity at rest and upon movement was assessed on a numeric rating scale (0-10) on an hourly basis over 24 h if the patients were awake. The average pain at rest was marginally lower with LIA (1.6) than with femoral block (2.2). Total morphine consumption per kg was similar between the 2 groups. Ancillary analysis revealed that 1 of 20 patients in the LIA group reported a pain intensity of > 7 upon movement, as compared to 7 out of 19 in the femoral block group (p = 0.04). Both LIA and femoral block provide good analgesia after TKA. LIA may be considered to be superior to femoral block since it is cheaper and easier to perform.
- 4 November 2010
- Vol. 107 (35) , 2011-3
[Revision surgery in aseptic loosening of hip prosthesis. Mostly good clinical results also in extensive revisions].
- 4 November 2010
- Vol. 107 (35) , 2011-3
[Revision surgery in aseptic loosening of hip prosthesis. Mostly good clinical results also in extensive revisions].
- 13 October 2009
- Vol. 106 (37) , 2282-4
[Hip resurfacing. An alternative for selected and informed patients].
- 13 October 2009
- Vol. 106 (37) , 2282-4
[Hip resurfacing. An alternative for selected and informed patients].
- Open Access
- 1 October 2008
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. 1, 31-32
Good function but very high concentrations of cobalt and chromium ions in blood 37 years after metal-on-metal total hip arthroplasy
Dove Press is a member of the Open Access Initiative, specializing in peer reviewed Medical Journals. View articlesor submit your research for publishing
- 1 October 2008
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. 1, 31-32
Open AccessGood function but very high concentrations of cobalt and chromium ions in blood 37 years after metal-on-metal total hip arthroplasy
Dove Press is a member of the Open Access Initiative, specializing in peer reviewed Medical Journals. View articlesor submit your research for publishing
- Open Access
- 1 August 2008
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. 1, 13-8
Hip joint load in relation to leg length discrepancy
Peer reviewed article authored by (Per Wretenberg, Anders Hugo, Eva Broström). Read article or submit your manuscript for publishing.
- 1 August 2008
- Published by Taylor & Francis in Medical Devices: Evidence and Research
- Vol. 1, 13-8
Open AccessHip joint load in relation to leg length discrepancy
Peer reviewed article authored by (Per Wretenberg, Anders Hugo, Eva Broström). Read article or submit your manuscript for publishing.
- 22 April 2008
- Vol. 105 (10) , 737-40
[Discussed--but mini-incision hip arthroplasty here to stay].
- 9 February 2006
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 126 (3) , 145-149
Radial head prosthesis after fracture of radial head with associated elbow instability
Introduction: Fractures of the radial head and associated elbow instability can be treated with operation with radial head prosthesis. In this study, we evaluate function 1–7 years after implantation and also function after removal of five prostheses. Material and methods: Eighteen patients with radial head fracture and associated elbow instability were evaluated 3.7 years (1–7) after implantation of a radial head prosthesis. Pain at rest and during activity was measured with a visual analogue scale (VAS). Test of stability and neurological examination was done manually as well as measurement of the range of motion, using a goniometer. Activity of daily living (ADL) was estimated using five questions where the answers were graded between 1 and 3. The patients were asked to grade their general satisfaction according to the following scale; very satisfied, satisfied, not satisfied, disappointed. Plain X-rays were taken and 14 patients agreed to have their elbow strength evaluated using the validated BTE work simulator. Results: Five prostheses had been extracted due to poor range of motion. All these patients improved after extraction. All elbows were stable. No patient with extracted prosthesis had VAS score >2. The mean extension defect for this group was 15° (5–25) compared to the mean extension defect for the 13 patients with the prosthesis still in place 15° (0–40). The highest VAS score for the patients with prosthesis was five but the mean as low as 0.8. In the whole group, 13 patients were pain free. ADL function was good in general. The X-rays of the prostheses, still in place, showed radiolucent lines in 7 of the 13 patients. In the whole group, there was a significant decrease in supination, flexion and extension strength (PPPDiscussion: Radial head prosthesis works as a spacer after fracture of the radial head and associated instability. If range of motion is much restricted post-operatively, the prosthesis can be removed with improved function as result.
- 9 February 2006
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 126 (3) , 145-149
Radial head prosthesis after fracture of radial head with associated elbow instability
Introduction: Fractures of the radial head and associated elbow instability can be treated with operation with radial head prosthesis. In this study, we evaluate function 1–7 years after implantation and also function after removal of five prostheses. Material and methods: Eighteen patients with radial head fracture and associated elbow instability were evaluated 3.7 years (1–7) after implantation of a radial head prosthesis. Pain at rest and during activity was measured with a visual analogue scale (VAS). Test of stability and neurological examination was done manually as well as measurement of the range of motion, using a goniometer. Activity of daily living (ADL) was estimated using five questions where the answers were graded between 1 and 3. The patients were asked to grade their general satisfaction according to the following scale; very satisfied, satisfied, not satisfied, disappointed. Plain X-rays were taken and 14 patients agreed to have their elbow strength evaluated using the validated BTE work simulator. Results: Five prostheses had been extracted due to poor range of motion. All these patients improved after extraction. All elbows were stable. No patient with extracted prosthesis had VAS score >2. The mean extension defect for this group was 15° (5–25) compared to the mean extension defect for the 13 patients with the prosthesis still in place 15° (0–40). The highest VAS score for the patients with prosthesis was five but the mean as low as 0.8. In the whole group, 13 patients were pain free. ADL function was good in general. The X-rays of the prostheses, still in place, showed radiolucent lines in 7 of the 13 patients. In the whole group, there was a significant decrease in supination, flexion and extension strength (PPPDiscussion: Radial head prosthesis works as a spacer after fracture of the radial head and associated instability. If range of motion is much restricted post-operatively, the prosthesis can be removed with improved function as result.