Martin Kaipel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Martin Kaipel has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Sebastian Schützenberger
Department of Orthopaedic Surgery and Traumatology, AUVA Traumacenter Meidling, Vienna, Austria
3 shared publications Günter Sinz
Barmherzige Brüder Hospital
2 shared publicationsHeinz Redl
Ludwig Boltzmann Institute of Experimental and Clinical Traumatology
2 shared publicationsJames Ferguson
Ludwig Boltzmann Institute of Experimental and Clinical Traumatology
2 shared publicationsSebastian Farr
Orthopaedic Hospital Speising
2 shared publicationsAlexander Vlcek
Medical University Vienna
1 shared publication
Latest Publications
- 5 March 2015
- Published by Springer Nature in Wiener klinische Wochenschrift
- Vol. 127 (9-10) , 375-378
Migration characteristics and early clinical results of the NANOS® short-stem hip arthroplasty
Femoral short stems promise essential advantages in total hip arthroplasty. Up to now, only short- and midterm clinical studies exist. Data on early stem migration that could predict later aseptic loosening at an early stage are rare. The purpose of this study was to assess migration patterns and clinical outcome 2 years after hip replacement by a metaphyseal anchored cementless short stem. Migration data and clinical results were prospectively assessed in 49 patients. Clinical outcome was measured using the Harris Hip Score (HHS). Migration analyses were performed using the computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) system. At 2 years after surgery, none of the implants needed revision, and HHS increased from 47.9 up to 98.1. Of 49 patients, 5 (10 %) showed increased vertical stem migration (1.5 mm/2a) that might predict late aseptic loosening. Of 49 stems, 44 (90 %) showed stable migration patterns indicating a beneficial long-term outcome. Results of this study confirm the excellent clinical data of previous works. Migration patterns strongly suggest that short-stem arthroplasty is not only an innovative but also a reliable strategy in total hip replacement.
- 5 March 2015
- Published by Springer Nature in Wiener klinische Wochenschrift
- Vol. 127 (9-10) , 375-378
Migration characteristics and early clinical results of the NANOS® short-stem hip arthroplasty
Femoral short stems promise essential advantages in total hip arthroplasty. Up to now, only short- and midterm clinical studies exist. Data on early stem migration that could predict later aseptic loosening at an early stage are rare. The purpose of this study was to assess migration patterns and clinical outcome 2 years after hip replacement by a metaphyseal anchored cementless short stem. Migration data and clinical results were prospectively assessed in 49 patients. Clinical outcome was measured using the Harris Hip Score (HHS). Migration analyses were performed using the computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) system. At 2 years after surgery, none of the implants needed revision, and HHS increased from 47.9 up to 98.1. Of 49 patients, 5 (10 %) showed increased vertical stem migration (1.5 mm/2a) that might predict late aseptic loosening. Of 49 stems, 44 (90 %) showed stable migration patterns indicating a beneficial long-term outcome. Results of this study confirm the excellent clinical data of previous works. Migration patterns strongly suggest that short-stem arthroplasty is not only an innovative but also a reliable strategy in total hip replacement.
- 24 September 2014
- Published by Springer Nature in International Orthopaedics
- Vol. 39 (3) , 423-428
Reliability of radiographic landmarks in medial patello-femoral ligament reconstruction in relation to the anatomical femoral torsion
Anatomically correct graft positioning at the femoral insertion site is a key factor in surgical reconstruction of the medial patello-femoral ligament (MPFL). Basically there are two techniques to define this point in fluoroscopy during surgery. The role of the anatomical femoral torsion on the accuracy and reproducibility of both procedures has not been clarified. Twenty human anatomical leg specimens were dissected. The femoral insertion of the MPFL was marked by two K-wires. The position of the ligament insertion was determined fluoroscopically in the true lateral view as used in routine clinical practice. The anatomical MPFL insertion was compared to the radiographic landmarks which were recommended by two previous studies. The anatomical femoral torsion of the specimens was assessed by computed tomography scans. In true lateral view fluoroscopy, the mean distance of the femoral MPFL insertion was −0.2 mm distal to the vertical reference line intersecting the posterior point of Blumensaat’s line. In the anteroposterior direction, the mean distance was −2.0 mm posterior to the femoral cortex reference line. There was no correlation between anatomical femoral torsion and the distance of the femoral MPFL insertion to the posterior cortex. The results of this study strongly recommend use of a vertical line intersecting the most posterior point of Blumensaat’s line as a reference to identify the MPFL insertion in the craniocaudal direction. In the anteroposterior direction, the femoral MPFL insertion showed distinctive variation and was found −2.0 mm posterior to the femoral cortex reference line without being influenced by the anatomical femoral torsion.
- 24 September 2014
- Published by Springer Nature in International Orthopaedics
- Vol. 39 (3) , 423-428
Reliability of radiographic landmarks in medial patello-femoral ligament reconstruction in relation to the anatomical femoral torsion
Anatomically correct graft positioning at the femoral insertion site is a key factor in surgical reconstruction of the medial patello-femoral ligament (MPFL). Basically there are two techniques to define this point in fluoroscopy during surgery. The role of the anatomical femoral torsion on the accuracy and reproducibility of both procedures has not been clarified. Twenty human anatomical leg specimens were dissected. The femoral insertion of the MPFL was marked by two K-wires. The position of the ligament insertion was determined fluoroscopically in the true lateral view as used in routine clinical practice. The anatomical MPFL insertion was compared to the radiographic landmarks which were recommended by two previous studies. The anatomical femoral torsion of the specimens was assessed by computed tomography scans. In true lateral view fluoroscopy, the mean distance of the femoral MPFL insertion was −0.2 mm distal to the vertical reference line intersecting the posterior point of Blumensaat’s line. In the anteroposterior direction, the mean distance was −2.0 mm posterior to the femoral cortex reference line. There was no correlation between anatomical femoral torsion and the distance of the femoral MPFL insertion to the posterior cortex. The results of this study strongly recommend use of a vertical line intersecting the most posterior point of Blumensaat’s line as a reference to identify the MPFL insertion in the craniocaudal direction. In the anteroposterior direction, the femoral MPFL insertion showed distinctive variation and was found −2.0 mm posterior to the femoral cortex reference line without being influenced by the anatomical femoral torsion.
- 6 September 2014
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (12) , 2607-2613
Evaluation of fibrin-based gene-activated matrices for BMP2/7 plasmid codelivery in a rat nonunion model
Treatment of large-segmental bone defects still is a challenge in clinical routine. Application of gene-activated matrices (GAMs) based on fibrin, bone morphogenic protein (BMP) 2/7 plasmids and nonviral transfection reagents (cationic polymers) could be an innovative treatment strategy to overcome this problem. The aim of this study was to determine the therapeutic efficacy of fibrin GAMs with or without additional transfection reagents for BMP2 and 7 plasmid codelivery in a femur nonunion rat model. In this experimental study, a critical-sized femoral defect was created in 27 rats. At four weeks after the surgery, animals were separated into four groups and underwent a second operation. Fibrin clots containing BMP2/7 plasmids with and without cationic polymer were implanted into the femoral defect. Fibrin clots containing recombinant human (rh) BMP2 served as positive and clots without supplement as negative controls. At eight weeks, animals that received GAMs containing the cationic polymer and BMP2/7 plasmids showed decreased bone volume compared with animals treated with GAMs and BMP2/7 only. Application of BMP2/7 plasmids in fibrin GAMs without cationic polymer led to variable results. Animals that received rhBMP2 protein showed increased bone volume, and osseous unions were achieved in two of six animals. Cationic polymers decrease therapeutic efficiency of fibrin GAM-based BMP2/7 plasmid codelivery in bone regeneration. Nonviral gene transfer of BMP2/7 plasmids needs alternative promoters (e.g. by sonoporation, electroporation) to produce beneficial clinical effects.
- 6 September 2014
- Published by Springer Nature in International Orthopaedics
- Vol. 38 (12) , 2607-2613
Evaluation of fibrin-based gene-activated matrices for BMP2/7 plasmid codelivery in a rat nonunion model
Treatment of large-segmental bone defects still is a challenge in clinical routine. Application of gene-activated matrices (GAMs) based on fibrin, bone morphogenic protein (BMP) 2/7 plasmids and nonviral transfection reagents (cationic polymers) could be an innovative treatment strategy to overcome this problem. The aim of this study was to determine the therapeutic efficacy of fibrin GAMs with or without additional transfection reagents for BMP2 and 7 plasmid codelivery in a femur nonunion rat model. In this experimental study, a critical-sized femoral defect was created in 27 rats. At four weeks after the surgery, animals were separated into four groups and underwent a second operation. Fibrin clots containing BMP2/7 plasmids with and without cationic polymer were implanted into the femoral defect. Fibrin clots containing recombinant human (rh) BMP2 served as positive and clots without supplement as negative controls. At eight weeks, animals that received GAMs containing the cationic polymer and BMP2/7 plasmids showed decreased bone volume compared with animals treated with GAMs and BMP2/7 only. Application of BMP2/7 plasmids in fibrin GAMs without cationic polymer led to variable results. Animals that received rhBMP2 protein showed increased bone volume, and osseous unions were achieved in two of six animals. Cationic polymers decrease therapeutic efficiency of fibrin GAM-based BMP2/7 plasmid codelivery in bone regeneration. Nonviral gene transfer of BMP2/7 plasmids needs alternative promoters (e.g. by sonoporation, electroporation) to produce beneficial clinical effects.
- 18 January 2014
- Published by Springer Nature in Wiener klinische Wochenschrift
- Vol. 126 (7) , 208-211
Migration characteristics and early clinical results of a novel-finned press-fit acetabular cup
Ana Nova® is a novel-finned press-fit acetabular cup which showed superior biomechanical characteristics in an experimental set-up. Using Einzel Bild Röntgen Analyse (EBRA) measurements should offer the opportunity to predict implant survival at an early stage. The purpose of this study was to assess migration and clinical outcome 2 years after total hip replacement by a novel-finned press-fit acetabular cup. In this study, migration and clinical results of the implant were prospectively assessed in 67 patients. Clinical outcome was assessed using the Harris hip score (HHS). Migration analyses were performed using the computer assisted EBRA system. Data were analyzed for normal distribution using the Kolmogorov–Smirnov test. Group comparisons were performed using the analysis of variance (ANOVA) test. P-values less than 0.05 were considered statistically significant. At 2 years after surgery, none of the implants needed revision and HHS increased from 39.7 up to 92.2. In contrast to the beneficial clinical outcome, 17 of 44 patients showed increased total migration ( 1 mm/2a). Adverse migration data in this study might predict aseptic loosening and decreased survival of the implant. According to previous studies, it is possible that this effect occurred because of limited accuracy of the EBRA system. In our opinion, migration analyses may not be recommended as a screening tool in a 2 year follow-up. Ana Nova® ist eine neue Pressfit-Flügelpfanne, die überragende biomechanische Eigenschaften in Experimenten aufweist. Bis jetzt gibt es keinerlei Daten über die klinische Zuverlässigkeit. Mit Hilfe von Einzel Bild Röntgen Analyse (EBRA) Messungen sollte ein Vorhersagen der Lebensdauer eines Implantats zum frühen Zeitpunkt ermöglichen. Der Zweck dieser Studie war das Migrationsverhalten und die klinischen Ergebnisse 2 Jahre nach Implantation einer neuen Pressfit-Flügelpfanne zu erheben. In dieser Studie wurden das Migrationsverhalten und klinische Ergebnisse prospektiv an 67 Patienten erhoben. Klinische Ergebnisse wurden mit Hilfe des Harris Hip Scores erfasst. Das Migrationsverhalten wurde mit Hilfe von EBRA analysiert. 2 Jahre nach Implantation musste keine einzige Hüftpfanne revidiert werden. Der Harris Hip Score verbesserte sich von 39,7 auf 92,2. Im Gegensatz zu den erfreulichen klinischen Ergebnissen wurde in 17 von 44 Patienten erhöhte Totalmigration der Pfanne gemessen (> 1 mm/2a). Die erhöhten Migrationswerte in dieser Studie könnten auf aseptische Lockerung und reduzierte Lebensdauer des Implantats hinweisen. Gemäß bisherigen Studien ist es jedoch möglich, dass dieser Effekt aufgrund der limitierten Genauigkeit von EBRA auftrat. Unserer Meinung nach sollte EBRA nicht als Screening Methode in 2 Jahres Kontrollen eingesetzt werden.
- 18 January 2014
- Published by Springer Nature in Wiener klinische Wochenschrift
- Vol. 126 (7) , 208-211
Migration characteristics and early clinical results of a novel-finned press-fit acetabular cup
Ana Nova® is a novel-finned press-fit acetabular cup which showed superior biomechanical characteristics in an experimental set-up. Using Einzel Bild Röntgen Analyse (EBRA) measurements should offer the opportunity to predict implant survival at an early stage. The purpose of this study was to assess migration and clinical outcome 2 years after total hip replacement by a novel-finned press-fit acetabular cup. In this study, migration and clinical results of the implant were prospectively assessed in 67 patients. Clinical outcome was assessed using the Harris hip score (HHS). Migration analyses were performed using the computer assisted EBRA system. Data were analyzed for normal distribution using the Kolmogorov–Smirnov test. Group comparisons were performed using the analysis of variance (ANOVA) test. P-values less than 0.05 were considered statistically significant. At 2 years after surgery, none of the implants needed revision and HHS increased from 39.7 up to 92.2. In contrast to the beneficial clinical outcome, 17 of 44 patients showed increased total migration ( 1 mm/2a). Adverse migration data in this study might predict aseptic loosening and decreased survival of the implant. According to previous studies, it is possible that this effect occurred because of limited accuracy of the EBRA system. In our opinion, migration analyses may not be recommended as a screening tool in a 2 year follow-up. Ana Nova® ist eine neue Pressfit-Flügelpfanne, die überragende biomechanische Eigenschaften in Experimenten aufweist. Bis jetzt gibt es keinerlei Daten über die klinische Zuverlässigkeit. Mit Hilfe von Einzel Bild Röntgen Analyse (EBRA) Messungen sollte ein Vorhersagen der Lebensdauer eines Implantats zum frühen Zeitpunkt ermöglichen. Der Zweck dieser Studie war das Migrationsverhalten und die klinischen Ergebnisse 2 Jahre nach Implantation einer neuen Pressfit-Flügelpfanne zu erheben. In dieser Studie wurden das Migrationsverhalten und klinische Ergebnisse prospektiv an 67 Patienten erhoben. Klinische Ergebnisse wurden mit Hilfe des Harris Hip Scores erfasst. Das Migrationsverhalten wurde mit Hilfe von EBRA analysiert. 2 Jahre nach Implantation musste keine einzige Hüftpfanne revidiert werden. Der Harris Hip Score verbesserte sich von 39,7 auf 92,2. Im Gegensatz zu den erfreulichen klinischen Ergebnissen wurde in 17 von 44 Patienten erhöhte Totalmigration der Pfanne gemessen (> 1 mm/2a). Die erhöhten Migrationswerte in dieser Studie könnten auf aseptische Lockerung und reduzierte Lebensdauer des Implantats hinweisen. Gemäß bisherigen Studien ist es jedoch möglich, dass dieser Effekt aufgrund der limitierten Genauigkeit von EBRA auftrat. Unserer Meinung nach sollte EBRA nicht als Screening Methode in 2 Jahres Kontrollen eingesetzt werden.
- Open Access
- 16 April 2012
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 30 (10) , 1563-1569
BMP‐2 but not VEGF or PDGF in fibrin matrix supports bone healing in a delayed‐union rat model
Treatment of delayed bone healing and non‐unions after fractures, osteotomies or arthrodesis still is a relevant clinical challenge. Artificially applied growth factors can increase bone healing and progressively gain importance in clinical routine. The aim of this study was to determine the effects of rhPDGF‐BB, rhVEGF‐165, and rhBMP‐2 in fibrin matrix on bone healing in a delayed‐union rat model. Thirty‐seven rats underwent a first operation where a standardized femoral critical size defect was created. A silicone spacer was implanted to impair vascularization within the defect. At 4 weeks the spacer was removed in a second operation and rhPDGF‐BB, rhVEGF‐165, or rhBMP‐2 were applied in a fibrin clot. Animals in a fourth group received a fibrin clot without growth factors. At 8 weeks fibrin bound rhBMP‐2 treated animals showed a significantly increased union rate and bone volume within the defect compared to the other groups. Single application of fibrin bound rhPDGF‐BB and rhVEGF‐165 failed to increase bone healing in our atrophic non‐union model. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 30:1563–1569, 2012
- 16 April 2012
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 30 (10) , 1563-1569
Open AccessBMP‐2 but not VEGF or PDGF in fibrin matrix supports bone healing in a delayed‐union rat model
Treatment of delayed bone healing and non‐unions after fractures, osteotomies or arthrodesis still is a relevant clinical challenge. Artificially applied growth factors can increase bone healing and progressively gain importance in clinical routine. The aim of this study was to determine the effects of rhPDGF‐BB, rhVEGF‐165, and rhBMP‐2 in fibrin matrix on bone healing in a delayed‐union rat model. Thirty‐seven rats underwent a first operation where a standardized femoral critical size defect was created. A silicone spacer was implanted to impair vascularization within the defect. At 4 weeks the spacer was removed in a second operation and rhPDGF‐BB, rhVEGF‐165, or rhBMP‐2 were applied in a fibrin clot. Animals in a fourth group received a fibrin clot without growth factors. At 8 weeks fibrin bound rhBMP‐2 treated animals showed a significantly increased union rate and bone volume within the defect compared to the other groups. Single application of fibrin bound rhPDGF‐BB and rhVEGF‐165 failed to increase bone healing in our atrophic non‐union model. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 30:1563–1569, 2012