CRChristopher C. Rupp

Christopher C. Rupp

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christopher C. Rupp has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effectiveness of a Radiofrequency Detection System as an Adjunct to Manual Counting Protocols for Tracking Surgical Sponges: A Prospective Trial of 2,285 Patients

    by Christopher C. Rupp, Mary J. Kagarise, Stella M. Nelson, Allison M. Deal, Susan Phillips, Janet Chadwick, Tamara Petty, Anthony A. Meyer, Hong Jin Kim

    Despite rigorous manual counting protocols and the classification of retained surgical items (RSIs) as potential "never events," RSIs continue to occur in approximately 1 per 1,000 to 18,000 operations. This study's goals were to evaluate the incorporation of a radiofrequency detection system (RFDS) into existing laparotomy sponge- and Raytec-counting protocols for the detection of RSIs and define associated risk factors. All patients undergoing surgery at the University of North Carolina Hospitals from September 2009 to August 2010 were enrolled consecutively. The performance of an RFDS-incorporated accounting protocol for detecting RSIs was prospectively evaluated. Several operative metrics were recorded to identify risk factors for miscounts. A total of 2,285 patients were enrolled. One near miss was detected by the RFDS. Thirty-five miscounts occurred, for a rate of 1.53%. The ultimate locations of miscounted items were surgical site (n = 11), within operative suite (n = 10), surgical drapes (n = 2), and emergency protocol deviations (n = 12). Perioperative variables associated with miscounts were higher estimated volume of blood lost, longer operations, higher number of laparotomy sponges used, open surgical approach, "after hours" operations, change of surgical team during operation, weekend or holiday operations, unanticipated changes in operative plan during surgery, and emergency operations. Body mass index was not associated with miscounts. Surveys completed by participating surgical staff suggested high confidence in the RFDS for prevention of RSIs. The incorporation of the RFDS assisted in the resolution of a near-miss event (1 of 2,285) not detected by manual counting protocols and assisted in the resolution of 35 surgical-sponge miscounts. No known RSIs occurred during the study period. Risk factors for miscounts were identified and can help identify at-risk surgical populations.


  • Can Residents Safely and Efficiently be Taught Single Incision Laparoscopic Cholecystectomy?

    by Mark Joseph, Michael Phillips, Timothy M. Farrell, Christopher C. Rupp


  • Single Incision Laparoscopic Cholecystectomy Using a “Two-Port” Technique Is Safe and Feasible: Experience in 101 Consecutive Patients

    by Christopher C. Rupp, Timothy M. Farrell, Anthony A. Meyer

    Single incision laparoscopic cholecystectomy (SILC) is a new minimally-invasive technique that has recently been developed to address several disease processes of the gallbladder. However, the safety and feasibility of this technique are still being evaluated. Utilizing a “two-port” technique with transabdominal suture retraction and a rigorous adherence to the critical view of safety, we evaluated our experience in a prospectively maintained database and compared this with standard laparoscopic cholecystectomy (SLC) over the same period. SILC was completed successfully in 87 per cent of patients. Operative times were found to be similar between SLC and SILC (75 and 76 minutes, respectively; P = 0.12). Operative blood loss, hospital stay, and short-term complications were not statistically different between SILC and SLC. Cholangiograms, obtained on a selective basis, were performed in 19 per cent of SILCs. No bile duct injuries occurred during SILC or SLC. Although our aggregate number is not enough to accurately assess the rate or safety of bile duct injuries, SILC seems to be safe and feasible when evaluating other metrics and does not seem to interfere with operative efficiency compared with SLC.