Rachael L. Myers-Ward
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rachael L. Myers-Ward has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Charles R. Eddy
Electronics Science and Technology Division, US Naval Research Laboratory
3 shared publications - Scott A. Trammell
Center for Bio/Molecular Science and Engineering Code 6900
3 shared publications - D. Kurt Gaskill
U.S. Naval Research Laboratory
2 shared publications - Dan Zabetakis
Naval Research Laboratory, Center for Biomolecular Science and Engineering, Washington, DC 20375, USA
2 shared publications - David A. Stenger
U.S. Naval Research Laboratory, Center for Bio/Molecular Science & Engineering (Code 6900), 4555 Overlook Avenue SW, Washington, DC 20375, USA
2 shared publications - David Kurt Gaskill
U.S. Naval Research Laboratory, Washington, DC 20375, USA
2 shared publications
Latest Publications
- Open Access
Modifications of Epitaxial Graphene on SiC for the Electrochemical Detection and Identification of Heavy Metal Salts in Seawater
The electrochemical detection of heavy metal ions is reported using an inexpensive portable in-house built potentiostat and epitaxial graphene. Monolayer, hydrogen-intercalated quasi-freestanding bilayer, and multilayer epitaxial graphene were each tested as working electrodes before and after modification with an oxygen plasma etch to introduce oxygen chemical groups to the surface. The graphene samples were characterized using X-ray photoelectron spectroscopy, atomic force microscopy, Raman spectroscopy, and van der Pauw Hall measurements. Dose–response curves in seawater were evaluated with added trace levels of four heavy metal salts (CdCl2, CuSO4, HgCl2, and PbCl2), along with detection algorithms based on machine learning and library development for each form of graphene and its oxygen plasma modification. Oxygen plasma-modified, hydrogen-intercalated quasi-freestanding bilayer epitaxial graphene was found to perform best for correctly identifying heavy metals in seawater.
Open AccessModifications of Epitaxial Graphene on SiC for the Electrochemical Detection and Identification of Heavy Metal Salts in Seawater
The electrochemical detection of heavy metal ions is reported using an inexpensive portable in-house built potentiostat and epitaxial graphene. Monolayer, hydrogen-intercalated quasi-freestanding bilayer, and multilayer epitaxial graphene were each tested as working electrodes before and after modification with an oxygen plasma etch to introduce oxygen chemical groups to the surface. The graphene samples were characterized using X-ray photoelectron spectroscopy, atomic force microscopy, Raman spectroscopy, and van der Pauw Hall measurements. Dose–response curves in seawater were evaluated with added trace levels of four heavy metal salts (CdCl2, CuSO4, HgCl2, and PbCl2), along with detection algorithms based on machine learning and library development for each form of graphene and its oxygen plasma modification. Oxygen plasma-modified, hydrogen-intercalated quasi-freestanding bilayer epitaxial graphene was found to perform best for correctly identifying heavy metals in seawater.
- Open Access
Electrical and Low Frequency Noise Characterization of Graphene Chemical Sensor Devices Having Different Geometries
Chemiresistive graphene sensors are promising for chemical sensing applications due to their simple device structure, high sensitivity, potential for miniaturization, low-cost, and fast response. In this work, we investigate the effect of (1) ZnO nanoparticle functionalization and (2) engineered defects onto graphene sensing channel on device resistance and low frequency electrical noise. The engineered defects of interest include 2D patterns of squares, stars, and circles and 1D patterns of slots parallel and transverse to the applied electric potential. The goal of this work is to determine which devices are best suited for chemical sensing applications. We find that, relative to pristine graphene devices, nanoparticle functionalization leads to reduced contact resistance but increased sheet resistance. In addition, functionalization lowers 1/f current noise on all but the uniform mesa device and the two devices with graphene strips parallel to carrier transport. The strongest correlations between noise and engineering defects, where normalized noise amplitude as a function of frequency f is described by a model of AN/fγ, are that γ increases with graphene area and contact area but decreases with device total perimeter, including internal features. We did not find evidence of a correlation between the scalar amplitude, AN, and the device channel geometries. In general, for a given device area, the least noise was observed on the least-etched device. These results will lead to an understanding of what features are needed to obtain the optimal device resistance and how to reduce the 1/f noise which will lead to improved sensor performance.
Open AccessElectrical and Low Frequency Noise Characterization of Graphene Chemical Sensor Devices Having Different Geometries
Chemiresistive graphene sensors are promising for chemical sensing applications due to their simple device structure, high sensitivity, potential for miniaturization, low-cost, and fast response. In this work, we investigate the effect of (1) ZnO nanoparticle functionalization and (2) engineered defects onto graphene sensing channel on device resistance and low frequency electrical noise. The engineered defects of interest include 2D patterns of squares, stars, and circles and 1D patterns of slots parallel and transverse to the applied electric potential. The goal of this work is to determine which devices are best suited for chemical sensing applications. We find that, relative to pristine graphene devices, nanoparticle functionalization leads to reduced contact resistance but increased sheet resistance. In addition, functionalization lowers 1/f current noise on all but the uniform mesa device and the two devices with graphene strips parallel to carrier transport. The strongest correlations between noise and engineering defects, where normalized noise amplitude as a function of frequency f is described by a model of AN/fγ, are that γ increases with graphene area and contact area but decreases with device total perimeter, including internal features. We did not find evidence of a correlation between the scalar amplitude, AN, and the device channel geometries. In general, for a given device area, the least noise was observed on the least-etched device. These results will lead to an understanding of what features are needed to obtain the optimal device resistance and how to reduce the 1/f noise which will lead to improved sensor performance.
- Open Access
Multilayer Epitaxial Graphene on Silicon Carbide: A Stable Working Electrode for Seawater Samples Spiked with Environmental Contaminants
The electrochemical response of multilayer epitaxial graphene electrodes on silicon carbide substrates was studied for use as an electrochemical sensor for seawater samples spiked with environmental contaminants using cyclic square wave voltammetry. Results indicate that these graphene working electrodes are more robust and have lower background current than either screen-printed carbon or edge-plane graphite in seawater. Identification algorithms developed using machine learning techniques are described for several heavy metals, herbicides, pesticides, and industrial compounds. Dose-response curves provide a basis for quantitative analysis.
Open AccessMultilayer Epitaxial Graphene on Silicon Carbide: A Stable Working Electrode for Seawater Samples Spiked with Environmental Contaminants
The electrochemical response of multilayer epitaxial graphene electrodes on silicon carbide substrates was studied for use as an electrochemical sensor for seawater samples spiked with environmental contaminants using cyclic square wave voltammetry. Results indicate that these graphene working electrodes are more robust and have lower background current than either screen-printed carbon or edge-plane graphite in seawater. Identification algorithms developed using machine learning techniques are described for several heavy metals, herbicides, pesticides, and industrial compounds. Dose-response curves provide a basis for quantitative analysis.
- Open Access
Plasma-Modified, Epitaxial Fabricated Graphene on SiC for the Electrochemical Detection of TNT
Using square wave voltammetry, we show an increase in the electrochemical detection of trinitrotoluene (TNT) with a working electrode constructed from plasma modified graphene on a SiC surface vs. unmodified graphene. The graphene surface was chemically modified using electron beam generated plasmas produced in oxygen or nitrogen containing backgrounds to introduce oxygen or nitrogen moieties. The use of this chemical modification route enabled enhancement of the electrochemical signal for TNT, with the oxygen treatment showing a more pronounced detection than the nitrogen treatment. For graphene modified with oxygen, the electrochemical response to TNT can be fit to a two-site Langmuir isotherm suggesting different sites on the graphene surface with different affinities for TNT. We estimate a limit of detection for TNT equal to 20 ppb based on the analytical standard S/N ratio of 3. In addition, this approach to sensor fabrication is inherently a high-throughput, high-volume process amenable to industrial applications. High quality epitaxial graphene is easily grown over large area SiC substrates, while plasma processing is a rapid approach to large area substrate processing. This combination facilitates low cost, mass production of sensors.
Open AccessPlasma-Modified, Epitaxial Fabricated Graphene on SiC for the Electrochemical Detection of TNT
Using square wave voltammetry, we show an increase in the electrochemical detection of trinitrotoluene (TNT) with a working electrode constructed from plasma modified graphene on a SiC surface vs. unmodified graphene. The graphene surface was chemically modified using electron beam generated plasmas produced in oxygen or nitrogen containing backgrounds to introduce oxygen or nitrogen moieties. The use of this chemical modification route enabled enhancement of the electrochemical signal for TNT, with the oxygen treatment showing a more pronounced detection than the nitrogen treatment. For graphene modified with oxygen, the electrochemical response to TNT can be fit to a two-site Langmuir isotherm suggesting different sites on the graphene surface with different affinities for TNT. We estimate a limit of detection for TNT equal to 20 ppb based on the analytical standard S/N ratio of 3. In addition, this approach to sensor fabrication is inherently a high-throughput, high-volume process amenable to industrial applications. High quality epitaxial graphene is easily grown over large area SiC substrates, while plasma processing is a rapid approach to large area substrate processing. This combination facilitates low cost, mass production of sensors.
- 20 October 2014
- Published by American Chemical Society (ACS) in Crystal Growth & Design
- Vol. 14 (11) , 5331-5338
Spontaneous Conversion of Basal Plane Dislocations in 4° Off-Axis 4H–SiC Epitaxial Layers
- 20 October 2014
- Published by American Chemical Society (ACS) in Crystal Growth & Design
- Vol. 14 (11) , 5331-5338
Spontaneous Conversion of Basal Plane Dislocations in 4° Off-Axis 4H–SiC Epitaxial Layers
- 23 November 2012
- Published by Springer Nature in MRS Bulletin
- Vol. 37 (12) , 1149-1157
Enabling graphene-based technologies: Toward wafer-scale production of epitaxial graphene
- 23 November 2012
- Published by Springer Nature in MRS Bulletin
- Vol. 37 (12) , 1149-1157
Enabling graphene-based technologies: Toward wafer-scale production of epitaxial graphene
- 30 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (6) , 3343-3347
Proton Irradiation of Ultraviolet 4H-SiC Single Photon Avalanche Diodes
The effects of proton irradiation on ultraviolet 4H-SiC single photon avalanche photodiodes (SPADs) are investigated for the first time. The SPADs, grown by chemical vapor deposition, were designed for operation in the ultraviolet having dark count rates (DCR) of about 30 kHz and single photon detection efficiency (SPDE) of 4.89%. The SPADs were irradiated with 2 MeV protons to a fluence of 1012 cm-2. After irradiation, the avalanche breakdown voltage shifted downward 0.6 V from 113 V and the I-V characteristics show forward voltage (<; 1.9 V) generation-recombination currents 2 to 3 times higher than before irradiation. Single photon counting measurements at -114.2 V show lower voltage pulse height and a higher DCR at low threshold voltage, probably due to generation-recombination centers created in the band gap after irradiation. Yet, with the threshold voltage ranging from 23 to 26 mV, the 4H-SiC SPAD still showed low DCR (<; 54 kHz) and a reasonably high SPDE (>; 1%) after irradiation. The devices were demonstrated to show proton radiation tolerance for geosynchronous space applications.
- 30 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (6) , 3343-3347
Proton Irradiation of Ultraviolet 4H-SiC Single Photon Avalanche Diodes
The effects of proton irradiation on ultraviolet 4H-SiC single photon avalanche photodiodes (SPADs) are investigated for the first time. The SPADs, grown by chemical vapor deposition, were designed for operation in the ultraviolet having dark count rates (DCR) of about 30 kHz and single photon detection efficiency (SPDE) of 4.89%. The SPADs were irradiated with 2 MeV protons to a fluence of 1012 cm-2. After irradiation, the avalanche breakdown voltage shifted downward 0.6 V from 113 V and the I-V characteristics show forward voltage (<; 1.9 V) generation-recombination currents 2 to 3 times higher than before irradiation. Single photon counting measurements at -114.2 V show lower voltage pulse height and a higher DCR at low threshold voltage, probably due to generation-recombination centers created in the band gap after irradiation. Yet, with the threshold voltage ranging from 23 to 26 mV, the 4H-SiC SPAD still showed low DCR (<; 54 kHz) and a reasonably high SPDE (>; 1%) after irradiation. The devices were demonstrated to show proton radiation tolerance for geosynchronous space applications.
- 1 January 2010
- Published by Springer Nature in MRS Proceedings
- Vol. 1259
Dry Techniques for Epitaxial Graphene Transfer
- 1 January 2010
- Published by Springer Nature in MRS Proceedings
- Vol. 1259
Dry Techniques for Epitaxial Graphene Transfer
- 1 January 2008
- Published by Springer Nature in MRS Proceedings
- Vol. 1068
Nondestructive defect measurement and surface analysis of 3C-SiC on Si (001) by electron channeling contrast imaging
- 1 January 2008
- Published by Springer Nature in MRS Proceedings
- Vol. 1068
Nondestructive defect measurement and surface analysis of 3C-SiC on Si (001) by electron channeling contrast imaging