MWMarcus Wiemer

Marcus Wiemer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marcus Wiemer has a total of 209 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Sirolimus-Eluting Balloon With Provisional Stenting Versus Systematic Drug-Eluting Stent Implantation to Treat De Novo Coronary Lesions: A Randomized, Open-Label, Noninferiority Trial

    by Christian Spaulding, Florian Krackhardt, Kris Bogaerts, Eltigani Abdelaal, Fernando Alfonso, Carlo Briguori, Leonhard Bruch, Nicholas Cruden, Alexander W. Den Hartog, Philippe Garot, et al.

    BACKGROUND: Implantation of drug eluting stents (DESs) is currently the default approach for percutaneous coronary interventions, but long-term adverse events still exist. An approach with minimal stenting deserves to be assessed in a randomized trial. We studied a novel sirolimus-eluting balloon (SEB) that elutes sirolimus over a 90-day period using a biodegradable polymer microreservoir technology. METHODS: In a multicenter, open-label, randomized trial, we compared an SEB-based strategy with provisional DES with one of systematic DES for de novo lesions in coronary arteries between 2 and 5 mm in diameter. Subjects were randomized 1:1 before percutaneous coronary intervention. The primary end point was target vessel failure, a composite of cardiac death, target vessel–related myocardial infarction, and clinically driven target vessel revascularization. It was tested for noninferiority at 1 year with the use of an absolute margin equal to 50% of the combined event rate at a significance level of 0.025. The primary analysis population included all randomized subjects with completed or attempted percutaneous revascularization, analyzed according to the intention-to-treat principle. A sensitivity analysis was performed on the per-protocol population. RESULTS: Between August 27, 2021, and July 29, 2024, 3323 participants were randomized and treated in 62 sites. Among 1661 participants in the SEB strategy group, bailout stenting was performed in 343 (20.7%). Target vessel failure occurred over 365 days in 88 (5.3%) and 73 (4.4%) participants in the SEB and the systematic DES strategy groups, respectively (risk difference, 0.91% [95% CI –0.55% to 2.38%]; 1-sided P =0.02 for noninferiority with a 2.44% noninferiority margin). Clinically driven target vessel revascularization occurred more frequently in the SEB strategy group (3.3% versus 2.1%; risk difference, 1.22% [95% CI, 0.11%–2.33%). Safety events, including lesion thrombosis, were low and similar in both groups. Although the results of the per-protocol population (3194 participants, 96%) did not confirm noninferiority (upper boundary of the 95% CI, 2.63; P =0.04), they were similar to the intention-to-treat results in both magnitude and direction. CONCLUSIONS: At 1 year, in the primary intention-to-treat analysis population, a strategy of percutaneous coronary intervention with SEB and provisional DES was noninferior to the systematic use of DES for the primary end point of target vessel failure. The per-protocol population sensitivity analysis did not confirm noninferiority. Clinically driven target vessel revascularization occurred more frequently in the SEB strategy group. At 5 years, target vessel failure will be tested again for noninferiority and for superiority if noninferiority is achieved. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04859985.


  • Open Access

    WATCH-PR: Comparison of the Pulse Rate of a WATCH-Type Blood Pressure Monitor with the Pulse Rate of a Conventional Ambulatory Blood Pressure Monitor

    by Mathini Vaseekaran, Marcus Wiemer, Sven Kaese, Dennis Görlich, Jochen Hinkelbein, Gerrit Jansen, Alexander Samol

    Background: Monitoring pulse rate is fundamental to cardiovascular health management and early detection of rhythm disturbances. While oscillometric blood pressure measurement is well established and validated in clinical practice, its use for pulse rate monitoring, particularly via wrist-worn devices, remains largely unexplored. Objective: This study investigates whether a smartwatch that performs oscillometric blood pressure measurements at the wrist can also deliver reliable pulse rate readings using the same method. Methods: This study compared pulse rates recorded by the Omron HeartGuide smartwatch and conventional ambulatory blood pressure monitors in 50 patients over 24 h. Measurements were taken consecutively, and data were analyzed using intraclass correlation coefficients (ICCs) and Bland–Altman plots. Results: The study showed a high ICC of 0.971, indicating excellent agreement between devices. The average pulse rate difference was 1.5 bpm, with the Omron HeartGuide reporting slightly lower rates, especially in patients with atrial fibrillation. Conclusions: This study demonstrates that oscillometric pulse-rate monitoring at the wrist can achieve a high degree of accuracy, comparable to conventional upper-arm devices. Given that oscillometric smartwatches like the Omron HeartGuide are already used for blood pressure monitoring, the findings suggest that they may also be suitable for pulse rate measurement, potentially enhancing their role in telemetric healthcare, but further research is needed, particularly in patients with arrhythmias.

  • Open Access

    WATCH-BPM—Comparison of a WATCH-Type Blood Pressure Monitor with a Conventional Ambulatory Blood Pressure Monitor and Auscultatory Sphygmomanometry

    by Mathini Vaseekaran, Sven Kaese, Dennis Görlich, Marcus Wiemer, Alexander Samol

    Background: Smart devices that are able to measure blood pressure (BP) are valuable for hypertension or heart failure management using digital technology. Data regarding their diagnostic accuracy in comparison to standard noninvasive measurement in accordance to Riva-Rocci are sparse. This study compared a wearable watch-type oscillometric BP monitor (Omron HeartGuide), a wearable watch-type infrared BP monitor (Smart Wear), a conventional ambulatory BP monitor, and auscultatory sphygmomanometry. Methods: Therefore, 159 consecutive patients (84 male, 75 female, mean age 64.33 ± 16.14 years) performed observed single measurements with the smart device compared to auscultatory sphygmomanometry (n = 109) or multiple measurements during 24 h compared to a conventional ambulatory BP monitor on the upper arm (n = 50). The two BP monitoring devices were simultaneously worn on the same arm throughout the monitoring period. In a subgroup of 50 patients, single measurements were also performed with an additional infrared smart device. Results: The intraclass correlation coefficient (ICC) between the difference and the mean of the oscillometric Omron HeartGuide and the conventional method for the single measurement was calculated for both systole (0.765) and diastole (0.732). This is exactly how the ICC was calculated for the individual mean values calculated over the 24 h long-term measurement of the individual patients for both systole (0.880) and diastole (0.829). The ICC between the infrared device and the conventional method was “bad” for SBP (0.329) and DBP (0.025). Therefore, no further long-term measurements were performed with the infrared device. Conclusion: The Omron HeartGuide device provided comparable BP values to the standard devices for single and long-term measurements. The infrared smart device failed to acquire valid measurement data.


  • Open Access

    Safety and performance of the third-generation drug-eluting resorbable coronary magnesium scaffold system in the treatment of subjects with de novo coronary artery lesions: 6-month results of the prospective, multicenter BIOMAG-I first-in-human study

    by Michael Haude, Adrian Wlodarczak, René J. van der Schaaf, Jan Torzewski, Bert Ferdinande, Javier Escaned, Juan F. Iglesias, Johan Bennett, Gabor Toth, Michael Joner, et al.


  • Six-Month Outcomes after Extracorporeal Membrane Oxygenation Therapy for Severe COVID-19-Related Pulmonary Failure

    by S. Guenther, R. Cheaban, L. Höpner, N. Weinrautner, T. Kirschning, R. Al-Khalil, F. Brünger, R. Serrano, I. Barndt, M. Wiemer, et al.

    Background: Little is known on the impact of COVID-19-associated intensive care medical therapy including extracorporeal life support/membrane oxygenation (ECMO) on the long-term well-being of survivors. The aim of this study is to comprehensively characterize recovery six months after ECMO treatment for COVID-19-associated pulmonary failure. Method: All patients requiring veno-venous or veno-arterial ECMO for COVID-19-associated respiratory and/or circulatory failure between April 2020 and September 2021 were included in this retrospective analysis. Parameters included age, gender, time of ECMO treatment, and survival at hospital discharge and 6 months post-ECMO initiation. Comprehensive follow-up covering cardiopulmonary, neurocognitive, psychological, and functional status, as well as the health-related quality of life was assessed in discharged survivors. Results: Sixty patients (median age: 60.5 [51.0–65.0] years, range: 20–72 years, 23.3% female) were treated with veno-venous or veno-arterial ECMO for severe COVID-19-related pulmonary failure with or without associated circulatory failure. 41.7% (n = 25) were successfully weaned off ECMO after 24.0 (17.5–32.5, range: 10–65) days, and 40.0% (n = 24) survived to hospital discharge. At 6 months post ECMO initiation, 20 patients were alive (33.3% of all patients, 83.3% survival conditioned on survival to discharge). Of these, 19 underwent comprehensive follow-up after 6.0 (5.0–9.0) months (133 months of cumulative follow-up time). 57.9% showed no relevant or only mild deficits, while 26.3% showed moderate, and 15.8% severe deficits. Cardiopulmonary status (mMRC level: 2.0 [1.0–2.0], 84.2% ≤ 2, NYHA level 2.0 [2.0–3.0], no patient in need of home oxygen) and level of independence (73.7% with no or mild disability and independent in daily life) were satisfactory. The rate of cognitive impairments was substantial (52.6%). In 21.1%, minimal or slight depression was observed, in 26.3% moderate depression, and 15.8% showed signs of post-traumatic stress disorder. Altogether, marked impacts on social and work life were observed. Conclusion: ECMO can serve as a salvage therapy for patients with severest COVID-19-related pulmonary failure, but the total burden of deficits six months after ECMO initiation is substantial with effects on social life and work status. The focus of our efforts thus needs to shift from solely acute survival to meaningful long-term recovery. Article published online: 28 January 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

  • Open Access

    Single-Lead ECG Recordings Including Einthoven and Wilson Leads by a Smartwatch: A New Era of Patient Directed Early ECG Differential Diagnosis of Cardiac Diseases?

    by Alexander Samol, Kristina Bischof, Blerim Luani, Dan Pascut, Marcus Wiemer, Sven Kaese

    Background: Smartwatches that are able to record a bipolar ECG and Einthoven leads were recently described. Nevertheless, for detection of ischemia or other cardiac diseases more leads are required, especially Wilson’s chest leads. Objectives: Feasibility study of six single-lead smartwatch (Apple Watch Series 4) ECG recordings including Einthoven (I, II, III) and Wilson-like pseudo-unipolar chest leads (Wr, Wm, Wl). Methods: In 50 healthy subjects (16 males; age: 36 ± 11 years, mean ± SD) without known cardiac disorders, a standard 12-lead ECG and a six single-lead ECG using an Apple Watch Series 4 were performed under resting conditions. Recording of Einthoven I was performed with the watch on the left wrist and the right index finger on the crown, Einthoven II was recorded with the watch on the left lower abdomen and the right index finger on the crown, Einthoven III was recorded with the watch on the left lower abdomen and the left index finger on the crown. Wilson-like chest leads were recorded corresponding to the locations of V1 (Wr), V4 (Wm) and V6 (Wl) in the standard 12-lead ECG. Wr was recorded in the fourth intercostal space right parasternal, Wm was recorded in the fifth intercostal space on the midclavicular line, and Wl was recorded in the fifth intercostal space in left midaxillary line. For all Wilson-like chest lead recordings, the smartwatch was placed on the described three locations on the chest, the right index finger was placed on the crown and the left hand encompassed the right wrist. Both hands and forearms also had contact to the chest. Three experienced cardiologists were independently asked to allocate three bipolar limb smartwatch ECGs to Einthoven I–III leads, and three smartwatch Wilson-like chest ECGs (Wr, Wm, Wl) to V1, V4 and V6 in the standard 12-lead ECG for each subject. Results: All 300 smartwatch ECGs showed a signal quality useable for diagnostics with 281 ECGs of good signal quality (143 limb lead ECGs (95%), 138 chest lead ECGs (92%). Nineteen ECGs had a moderate signal quality (7 limb lead ECGs (5%), 12 chest lead ECGs (8%)). One-hundred percent of all Einthoven and 92% of all Wilson-like smartwatch ECGs were allocated correctly to corresponding leads from 12-lead ECG. Forty-six subjects (92%) were assigned correctly by all cardiologists. Allocation errors were due to similar morphologies and amplitudes in at least two of the three recorded Wilson-like leads. Despite recording with a bipolar smartwatch device, morphology of all six leads was identical to standard 12-lead ECG. In two patients with acute anterior myocardial infarction, all three cardiologists recognized the ST-elevations in Wilson-like leads and assumed an occluded left anterior descending coronary artery correctly. Conclusion: Consecutive recording of six single-lead ECGs including Einthoven and Wilson-like leads by a smartwatch is feasible with good ECG signal quality. Thus, this simulated six-lead smartwatch ECG may be useable for the detection of cardiac diseases necessitating more than one ECG lead like myocardial ischemia or more complex cardia arrhythmias.


  • Open Access

    Recording of Bipolar Multichannel ECGs by a Smartwatch: Modern ECG Diagnostic 100 Years after Einthoven

    by Alexander Samol, Kristina Bischof, Blerim Luani, Dan Pascut, Marcus Wiemer, Sven Kaese

    Aims: Feasibility study of accurate three lead ECG recording (Einthoven I, II and III) using an Apple Watch Series 4. Methods: In 50 healthy subjects (18 male; age: 40 ± 12 years) without known cardiac disorders, a 12-lead ECG and three bipolar ECGs, corresponding to Einthoven leads I, II and III were recorded using an Apple Watch Series 4. Einthoven I was recorded with the watch on the left wrist and the right index finger on the crown, Einthoven II with the watch on the left lower abdomen and the right index finger on the crown, Einthoven III with the watch on the left lower abdomen and the left index finger on the crown. Four experienced cardiologists were independently asked to assign the watch ECGs to Einthoven leads from 12-lead ECG for each subject. Results: All watch ECGs showed an adequate signal quality with 134 ECGs of good (89%) and 16 of moderate signal quality (11%). Ninety-one percent of all watch ECGs were assigned correctly to corresponding leads from 12-lead ECG. Thirty-nine subjects (78%) were assigned correctly by all cardiologists. All assignment errors occurred in patients with similar morphologies and amplitudes in at least two of the three recorded leads. Erroneous assignment of all watch ECGs to leads from standard ECG occurred in no patient. Conclusion: Recording of Einthoven leads I-III by a smartwatch is accurate and highly comparable to standard ECG. This might contribute to an earlier detection of cardiac disorders, which are associated with repolarization abnormalities or arrhythmias.


  • Open Access

    Intracardiac echocardiography versus fluoroscopy for endovascular and endocardial catheter navigation during cryo-ablation of the slow pathway in AVNRT patients

    by Blerim Luani, Thomas Rauwolf, Conrad Genz, Alexander Schmeißer, Marcus Wiemer, Rüdiger C. Braun-Dullaeus

    A new zero-fluoroscopy technique for electrophysiology catheter navigation relying on intracardiac echocardiography (ICE) has been recently reported (Ice&ICE trial). We investigated potential differences in efficacy, safety or procedural performance between conventional fluoroscopy- and ICE-guided cryothermal ablation (CA) in symptomatic AVNRT patients. Clinical and electrophysiological data of AVNRT patients included in the Ice&ICE trial (22 patients, 16 females; =zero-fluoroscopy group) were compared to those of consecutive AVNRT patients, who underwent fluoroscopy-guided CA (25 patients, 17 females; = fluoroscopy group) during the last 2 years in our institution. Slow pathway ablation or modulation was successful in all patients. Fluoroscopy time and radiation dose in the fluoroscopy group were 11.2 ± 9.0 min and 20.3 ± 16.2Gycm2, whereas no fluoroscopy was used in the opposite group (p < 0.001, respectively). EPS duration was not different between the groups (zero-fluoroscopy:101.6 ± 40.2 min, fluoroscopy:99.4 ± 37.2 min, p = n.s.). Catheter placement time was significantly shorter in the fluoroscopy group (2.2 ± 1.6 min vs. 12.0 ± 7.5 min, p < 0.05), whereas cryo-application duration (from the first cryo-mapping to the last CA) was significantly shorter in the zero-fluoroscopy group (27.5 ± 37.0 min vs. 38.1 ± 33.9 min, p < 0.05). Mean cryo-mapping and CA applications were numerically lower in the zero-fluoroscopy group (CM:7.5 ± 5.7 vs. 8.8 ± 6.2; CA:3.1 ± 1.7 vs. 3.2 ± 2.0, p = n.s.). No major adverse events occurred in both groups. After 15.0 ± 4.2 months, arrhythmia recurrence was not different between the groups (4.5% vs. 8.0%, p = n.s.). Zero-fluoroscopy ICE-guided EP catheter navigation shows comparable efficacy and safety to fluoroscopic guidance during CA in AVNRT patients. ICE visualization of catheters and endocardial structures within the triangle of Koch shortens the cryo-application duration, though time needed for catheter placement is longer, when compared with conventional fluoroscopic guidance, which results in similar mean EPS duration with both navigation techniques. (German Clinical Trials Register ID: DRKS00011360 ; Registration Date 14.12.2016)


  • Open Access

    Cerebrovascular events, bleeding complications and device related thrombi in atrial fibrillation patients with chronic kidney disease and left atrial appendage closure with the WATCHMAN™ device

    by Blerim Luani, Conrad Genz, Joerg Herold, Andreas Mitrasch, Julius Mitusch, Marcus Wiemer, Alexander Schmeißer, Rüdiger C. Braun-Dullaeus, Thomas Rauwolf

    Impaired renal function increases the bleeding risk, leading to a conservative prescription and frequent discontinuation of oral anticoagulation in atrial fibrillation patients with chronic kidney disease (CKD). Interventional left atrial appendage closure (LAAC) might be an alternative therapeutic strategy for these patients. We aimed to prospectively assess cerebrovascular (CE) and bleeding events, as well as peri-procedural and long-term complications in a cohort of consecutive patients undergoing interventional LAAC using the WATCHMAN™ device, with focus on CKD patients. One hundred and eighty-nine consecutive patients undergoing interventional LAAC were included in this analysis; 171 (90.5%) patients had a reduced estimated glomerular filtration rate (eGFR; patients for each CKD stage: II = 66; IIIa = 32; IIIb = 43; IV = 18; V = 12). During a follow-up of 310 patient years three (1.0%) patients suffered a CE (two strokes, one transitory ischemic attack) and five (1.6%) other ones a bleeding complication. The observed stroke rate was more than two-thirds and the bleeding risk more than half lower than expected. Device related thrombi (DRT) were detected in twelve (6.5%) patients; women had significantly more DRT than men (12.5% vs. 2.6%; p = 0.009). Patients with an eGFR< 30 ml/min/1.73m2 showed a trend to a higher DRT rate as compared to the opposite group (13.3% vs. 5.1%; p = 0.10). Thrombus resolved with temporary oral anticoagulation therapy in ten patients without sequelae; thrombus consolidation was confirmed by serial TEE controls in the remaining two patients. Atrial fibrillation patients with CKD have low CE and bleeding rates after LAAC with the WATCHMAN™ device. DRT risk is higher in female and patients with severe CKD. More frequent post-interventional TEE controls might be justified for early DRT detection and safe management of patients at high DRT risk. (German Clinical Trials Register ID: DRKS00 010768 ; Registration Date 07.07.2016).


  • Open Access

    Herzkatheter: Diagnostik und Intervention über die Arteria radialis

    by M. Wiemer, T. Schäufele, T. Schmitz, S. Hoffmann, T. Comberg, H. Eggebrecht, C. Langer