DJDarina Jasikova

Darina Jasikova

*This is an algorithmically generated author record based on publicly available information.

Darina Jasikova has a total of 49 co-authors. Here are the top co-authors by number of shared publications:

  • Michal Kotek

    Department of Physical Measurements, Institute for Nanomaterials, Advanced Technologies and Innovation, 46117 Liberec, Czech Republic

    13 shared publications
  • Vaclav Kopecky

    Department of Physical Measurements, Institute for Nanomaterials, Advanced Technologies and Innovation, 46117 Liberec, Czech Republic

    7 shared publications
  • Václav Kopecký

    Department of Physical Measurement, Technical University of Liberec, Institute for Nanomaterials, Advanced Technology and Innovation, Studentska 1402/2, Liberec 1, 461 17, Czech Republic

    5 shared publications
  • Bohuš Kysela

    Institute of Hydrodynamics, AS CR, v.v.i., Pod Patankou 30/5, 166 12 Prague 6, Czech Republic

    4 shared publications
  • Radek Šulc

    Department of Process Engineering, Faculty of Mechanical Engineering, Czech Technical University in Prague, Technická 4, 160 00 Prague, Czech Republic

    4 shared publications
  • Václav Kopecký

    Technical University of Liberec

    4 shared publications

Latest Publications

  • Open Access

    A microfluidic chip for generation a lipid phase in an aqueous dispersion

    by Darina Jasikova, Michal Kotek, Petr Bratka, Petr Sidlof, Vaclav Kopecky

    The subject of study involves the handling of liquids and gases in the order of micro-litres and in micro scale resolution. Microfluidic structures are very fine in the context of the macro world, and standard dimensions are around 100 µm, but even finer, depending on the manufacturing process. Visualization are used to study events and processes inside microstructures. Events taking place in fine structures are influenced by parameters such as liquid resistance, interfacial forces, diffusion transfer of molecules and mutual interactions both at the chemical and thermodynamic levels. The analysis of the behaviour of liquids in microfluidic systems involves a change of approach in deriving the influence of input conditions on the resulting behaviour and the course of interactions both between the wall of the structure and the liquid, but also in the liquid itself. The methodology and production of a microfluidic device usually uses a number of technologies. The process often combines a lithographic technique with a controlled etching or laser engraving method. This article introduces the initial experiments with droplet microfluidic generators, which took place at TUL - CXI and subsequently led to the construction of your own implementation in the form of a capillary chip that can be used in pharmacy.

  • Open Access

    On the Use of Laser Fragmentation for the Synthesis of Ligand-Free Ultra-Small Iron Nanoparticles in Various Liquid Environments

    by Ondřej Havelka, Martin Cvek, Michal Urbánek, Dariusz Łukowiec, Darina Jašíková, Michal Kotek, Miroslav Černík, Vincenzo Amendola, Rafael Torres-Mendieta

    Traditionally, the synthesis of nanomaterials in the ultra-small size regime (1–3 nm diameter) has been linked with the employment of excessive amounts of hazardous chemicals, inevitably leading to significant environmentally detrimental effects. In the current work, we demonstrate the potential of laser fragmentation in liquids (LFL) to produce highly pure and stable iron ultra-small nanoparticles. This is carried out by reducing the size of carbonyl iron microparticles dispersed in various polar solvents (water, ethanol, ethylene glycol, polyethylene glycol 400) and liquid nitrogen. The explored method enables the fabrication of ligand-free iron oxide ultra-small nanoparticles with diameter in the 1–3 nm range, a tight size distribution, and excellent hydrodynamic stability (zeta potential > 50 mV). The generated particles can be found in different forms, including separated ultra-small NPs, ultra-small NPs forming agglomerates, and ultra-small NPs together with zero-valent iron, iron carbide, or iron oxide NPs embedded in matrices, depending on the employed solvent and their dipolar moment. The LFL technique, aside from avoiding chemical waste generation, does not require any additional chemical agent, other than the precursor microparticles immersed in the corresponding solvent. In contrast to their widely exploited chemically synthesized counterparts, the lack of additives and chemical residuals may be of fundamental interest in sectors requiring colloidal stability and the largest possible number of chemically active sites, making the presented pathway a promising alternative for the clean design of new-generation nanomaterials.


  • Open Access

    Evaluation of the Influence of Anomalies on the Flow of Non-Newtonian Fluid in Carotid Bifurcation by the PIV Method

    by Darina Jasikova, Nikola Pluchova, Michal Kotek, Václav Kopecký

    The blood flow in anomalous carotid bifurcation is associated with stroke. Changed character of the flow, especially the occurrence of vortex structures, has showed a high correlation with thrombus formation and the development of atherosclerotic changes. The purpose of this work is to perform comparative model measurements of the flow inside the internal carotid bifurcation and to evaluate the influence of the geometry - stenosis, aneurysm on changes in the interaction of the fluid with the wall surface, i.e. on the local hemodynamic. The study uses the Global Imaging Methods for visualization and measurement of the phantom blood flow. The evaluation of the measured dataset and their subsequent analysis confirms the impact on the origin and development of pathological changes.


  • Open Access

    Flow field velocity measurement of liquid interaction with rigid and flexible wall

    by Darina Jasikova, Michal Kotek, Frantisek Pochyly, Vaclav Kopecky

    The motivation of this research was to determine the flow interactions on the pulsation and to express the influence on the flow character in the rigid and flexible tube. The character of Newtonian liquid was measured with the Particle Image Velocimetry method (PIV). Here, we used glass tube and Tygon tube for our comparison. We build the circuit equipped with membrane pump for generating pulsatile flow. The results were analysed over the pulse period sampled in 10 time steps. The fluid flow varied from Re 560 to Re 8800. The velocity profiles uncovered backward revers flows closed to the wall. These structures are prevailing close to flexible wall. The effect of interaction between pulsatile liquid flow and flexible wall was experimentally proved.

  • Open Access

    Measurement of drop size distribution time rate for liquid-liquid dispersion using IPI method

    by Darina Jasikova, Michal Kotek, Bohus Kysela, Radek Sulc, Vaclav Kopecky

    The liquid-liquid dispersion properties are studied mainly by image analysis (IA) and Interferometric Particle Imaging (IPI). Drop sizes will be investigated in dilute dispersion since in this case the break up phenomena is the dominating and is not affected by phase fraction. Characteristics of the size distribution and the evolution of two liquid-liquid phase’s disintegration were studied. The IPI method was used for subsequent detailed study of the disintegrated droplets. We compared two liquids: Rhodosil Oil 47V50, and Silicone Oil AP1000 under stirrer rate of 540 rpm, and 760 rpm. The experiment run in the scaled model of agitated tank with Rushton turbine.

  • Open Access

    Mixing of two immiscible phases measured by industrial electrical impedance tomography system

    by Michal Malík, Jiří Primas, Michal Kotek, Darina Jašíková, Václav Kopecký

    The mixing of two immiscible phases is a process commonly seen in many industrial applications. Whether it is desirable (e.g. mixing of ingredients in chemical or food industry) or undesirable (e.g. sediments or contaminants in water purification) process, it has to be taken into consideration and a detailed description would be beneficial to any end product. This paper deals with a method for observing the volume ratio of two immiscible phases from the state of total separation to the state of a homogenous mixture using industrial Electrical Impedance Tomography (EIT) system ITS p2+. This paper also shows a great advantage in combining the EIT measuring method with a theoretically derived formula. It is used to calculate the concentration of a non-conductive phase in the final mixture using the initial and final conductivity values. The authors were also able to show a possibility to successfully use the formula in situations, where the initial conditions for it are not fully met.


  • Influence of an External Air Flow on a System of High-Voltage Asymmetrical Electrodes

    by M. Malík, J. Primas, M. Kotek, D. Jašíková, V. Kopecký

    The paper deals with the problem of ascertaining the value of air flow velocity necessary to prevent electric current through the motion of ionized air between two asymmetrical electrodes. By means...


  • Flow of Newtonian and non-Newtonian fluid through pipe with flexible wall

    by Dominik Šedivý, Simona Fialová, Darina Jašíková

    This paper solves fluid-structure interaction between flexible wall and two types of fluid. Wall was considered as aorta and was described as hyperelastic material by 5-parameters Mooney-Rivlin model. Fluids and structure were set as incompressible. First fluid was Newtonian and has dynamic viscosity of the blood. Second was non-Newtonian and its viscosity was defined with Carreau rheology model. The aim of this paper is to show a comparison between Newtonian and non-Newtonian fluid flow in pliable vessel.


  • Micro-Particle Image Velocimetry for imaging flows in passive microfluidic mixers

    by Dariusz Witkowski, Wojciech Kubicki, Jan A. Dziuban, Darina Jašíková, Anna Karczemska


  • Open Access

    Comparison of cavitation bubbles evolution in viscous media

    by Darina Jasikova, Petr Schovanec, Michal Kotek, Vaclav Kopecky

    There have been tried many types of liquids with different ranges of viscosity values that have been tested to form a single cavitation bubble. The purpose of these experiments was to observe the behaviour of cavitation bubbles in media with different ranges of absorbance. The most of the method was based on spark to induced superheat limit of liquid. Here we used arrangement of the laser-induced breakdown (LIB) method. There were described the set cavitation setting that affects the size bubble in media with different absorbance. We visualized the cavitation bubble with a 60 kHz high speed camera. We used here shadowgraphy setup for the bubble visualization. There were observed time development and bubble extinction in various media, where the size of the bubble in the silicone oil was extremely small, due to the absorbance size of silicon oil.