Daniel Yeung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Daniel Yeung has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Jatinder Palta
University of Florida Health Science Center
8 shared publicationsCraig McKenzie
University of Florida Proton Therapy Institute Jacksonville Florida
2 shared publications- Jatinder R. Palta
Department of Radiation Oncology, University of Florida, Gainesville, FL, USA
2 shared publications - Nancy Price Mendenhall
Department of Radiation Oncology, University of Florida College of Medicine, Jacksonville, FL
2 shared publications - Zuofeng Li
University of Florida Proton Therapy Institute, Jacksonville, FL
2 shared publications - Brian F. Hasson
Abington Memorial Hospital
1 shared publication
Latest Publications
- 2 September 2013
- Published by Wiley in Pediatric Blood & Cancer
- Vol. 61 (1) , 89-94
A dosimetric comparison of intensity‐modulated proton therapy optimization techniques for pediatric craniopharyngiomas: A clinical case study
Background To evaluate the dosimetric characteristics of intensity‐modulated proton therapy (IMPT) optimization techniques and pencil‐beam scanning (PBS) nozzle designs on pediatric craniopharyngiomas. Procedure We compared a double‐scatter (DS) plan with IMPT plans using single‐field uniform dose (SFUD) optimization or multi‐field optimization (MFO) and different PBS nozzles. The clinical impacts of SFUD versus MFO, range shifters, and two different PBS nozzles were compared. For target coverage assessment, the conformity index and inhomogeneity coefficient were evaluated. Results Although both proton therapy techniques achieved adequate target coverage, IMPT achieved a better conformity index of 0.78 versus 0.60 for DS. For the inhomogeneity coefficient, IMPT with MFO performed better than using SFUD or DS. MFO with the dedicated nozzle (MFO‐DN) achieved the best result of 0.023, as compared to values of 0.03 or higher for the other plans. IMPT achieved lower doses to the normal tissues, as compared to DS; MFO‐DN had the best results. The DN provided the best beam‐spot characteristics and the sharpest lateral penumbra. MFO reduced the need for range shifters. Conclusions As compared to DS proton therapy for pediatric craniopharyngiomas, IMPT achieved significantly better target coverage and dose sparing of normal tissue. Nozzle designs that provided small beam spots and sharp lateral penumbra allowed for better target coverage and reduced dose to normal tissue. In the case of shallow targets, MFO, in contrast to SFUD, required minimal use of range shifters, which preserved the penumbra and the dosimetric advantage. MFO‐DN proved to be the optimal technique for IMPT. Pediatr Blood Cancer 2014;61:89–94.
- 2 September 2013
- Published by Wiley in Pediatric Blood & Cancer
- Vol. 61 (1) , 89-94
A dosimetric comparison of intensity‐modulated proton therapy optimization techniques for pediatric craniopharyngiomas: A clinical case study
Background To evaluate the dosimetric characteristics of intensity‐modulated proton therapy (IMPT) optimization techniques and pencil‐beam scanning (PBS) nozzle designs on pediatric craniopharyngiomas. Procedure We compared a double‐scatter (DS) plan with IMPT plans using single‐field uniform dose (SFUD) optimization or multi‐field optimization (MFO) and different PBS nozzles. The clinical impacts of SFUD versus MFO, range shifters, and two different PBS nozzles were compared. For target coverage assessment, the conformity index and inhomogeneity coefficient were evaluated. Results Although both proton therapy techniques achieved adequate target coverage, IMPT achieved a better conformity index of 0.78 versus 0.60 for DS. For the inhomogeneity coefficient, IMPT with MFO performed better than using SFUD or DS. MFO with the dedicated nozzle (MFO‐DN) achieved the best result of 0.023, as compared to values of 0.03 or higher for the other plans. IMPT achieved lower doses to the normal tissues, as compared to DS; MFO‐DN had the best results. The DN provided the best beam‐spot characteristics and the sharpest lateral penumbra. MFO reduced the need for range shifters. Conclusions As compared to DS proton therapy for pediatric craniopharyngiomas, IMPT achieved significantly better target coverage and dose sparing of normal tissue. Nozzle designs that provided small beam spots and sharp lateral penumbra allowed for better target coverage and reduced dose to normal tissue. In the case of shallow targets, MFO, in contrast to SFUD, required minimal use of range shifters, which preserved the penumbra and the dosimetric advantage. MFO‐DN proved to be the optimal technique for IMPT. Pediatr Blood Cancer 2014;61:89–94.
- 1 January 2013
- Published by Springer Nature
- p. 612
Pencil-Beam Scanning (PBS)
- 1 January 2013
- Published by Springer Nature
- p. 611-612
Passive Scattering
- 1 January 2013
- Published by Springer Nature
- p. 384
Intensity-Modulated Proton Therapy (IMPT)
- 1 January 2013
- Published by Springer Nature
- p. 63-64
Bragg Peak
- 1 January 2013
- Published by Springer Nature
- p. 125
Cobalt Gray Equivalent (CGE)
- 1 January 2013
- Published by Springer Nature
- p. 675-690
Proton Therapy
- 1 January 2013
- Published by Springer Nature
- p. 931
Uniform Scanning (US)
- 1 January 2013
- Published by Springer Nature
- p. 732
Range Straggling