MKMasaru Kubokawa

Masaru Kubokawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Masaru Kubokawa has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Prognostic factors associated with mortality in patients with gastric fundal variceal bleeding

    by Keishi Komori, Masaru Kubokawa, Eikichi Ihara, Kazuya Akahoshi, Kazuhiko Nakamura, Kenta Motomura, Akihide Masumoto

    Prognostic factors associated with mortality in patients with gastric fundal variceal bleeding


  • Endoscopic submucosal dissection of early duodenal tumor using the Clutch Cutter: a preliminary clinical study

    by Yosuke Minoda, Kazuya Akahoshi, Yoshihiro Otsuka, Masaru Kubokawa, Yasuaki Motomura, Masafumi Oya, Kazuhiko Nakamura

    Endoscopic submucosal dissection (ESD) is a minimally invasive method of treating early-stage tumors of the digestive tract. However, duodenal ESD is technically difficult, with high complication rates resulting from poor control of the endoscope, the thin duodenal wall, and the potential for exposure to pancreatic juices [1] [2]. This study evaluated the safety of ESD using the short-type Clutch Cutter for the removal of early duodenal tumors. The short-type Clutch Cutter (DP2618DT; Fujifilm Corporation, Tokyo, Japan) ([Fig. 1]) has previously been described in detail [3]. When the Clutch Cutter is being used for ESD of duodenal tumors, electrical damage to the thin muscle layer can be prevented by grasping the tissue and lifting it from the underlying proper muscle layer, before cutting or coagulating it. The steps of the ESD technique using the Clutch Cutter are illustrated in [Fig. 2]. Between September 2009 and December 2014, seven patients endoscopically diagnosed with early duodenal tumors underwent ESD using the Clutch Cutter ([Table 1]; [Fig. 3]). Preliminary esophagogastroduodenoscopy (EGD), endoscopic ultrasound (EUS), and endoscopic biopsy showed no evidence of lymph node metastasis in any of the patients. Almost all post-ESD ulcers were closed with clips to prevent delayed perforation. After ESD, all patients were treated with intravenous fluids and antibiotics for at least 2 days, and with an acid-suppression agent (rabeprazole 10 mg/day) for a minimum of 6 weeks. Clinical outcomes are summarized in [Table 1]. All lesions were resected easily and safely in one piece. There were no complications. Follow-up EGD at a mean of 8.7 months showed no incidence of tumor recurrence. Although endoscopically normal tissue had been excised in all patients, the margins could not be assessed pathologically in some of the patients, most likely as a result of heat denaturation. Although we assessed only a few patients, this study showed that ESD using the Clutch Cutter was safe for duodenal tumors. Endoscopy_UCTN_Code_TTT_1AO_2AG


  • Endoscopic submucosal dissection for rectal carcinoid tumour using the Clutch Cutter

    by Keishi Komori, Kazuya Akahoshi, Masaru Kubokawa, Yasuaki Motomura, Masafumi Oya, Eikichi Ihara, Kazuhiko Nakamura

    To reduce the risk of complications related to endoscopic submucosal dissection (ESD) using knives, we developed the Clutch Cutter (CC), which can grasp and incise the target tissue similarly to biopsy techniques using an electrosurgical current. The aim of this study was to evaluate the efficacy and safety of ESD using the CC for removal of rectal carcinoid tumours.


    • 1 April 2014
      • Vol. 105  (4) , 105-9

    Gastric glomus tumor diagnosed by endoscopic ultrasound-guided fine-needle aspiration biopsy: report of a case.

    by Yosuke Minoda, Kazuya Akahoshi, Masafumi Oya, Masaru Kubokawa, Yasuaki Motomura, Kazuhiko Nakamura

    A glomus tumor of the stomach is rare. It is difficult to diagnose the tumor before surgery by only endoscopic biopsy and radiography, and there is no established method of diagnosis before surgical treatment. Esophagogastroduodenoscopy (EGD) on a 50-year-old Japanese woman revealed a 10 mm submucosal tumor in the anterior wall of the gastric angle. Follow-up EGD revealed an increase in the size of the tumor to 15mm. Endoscopic ultrasonography (EUS) demonstrated a 15mm subepithelial hypoechoic solid tumor with continuity to the proper muscle layer. Histologic diagnosis by endoscopic ultrasonography guided fine needle aspiration (EUS-FNA) was glomus tumor. The tumor was treated by laparoscopic local resection. The histologic diagnosis of the resected tumor was similar to the preoperative EUS-FNA results. EUS-FNA would appear to be an effective histologic test for early diagnosis of gastric glomus tumor.


  • Endoscopic ultrasound diagnosis of a small splenic vein aneurysm

    by Keishi Komori, Kazuya Akahoshi, Yasuaki Motomura, Masaru Kubokawa, Junya Gibo, Kenji Kanayama, Shinichiro Fukuda, Shohei Hamada, Yoshiaki Otuka, Kazuhiko Nakamura

    Splenic vein aneurysm (SVA) is an extremely rare vascular abnormality. Although endoscopic ultrasound (EUS) can detect vascular structures, the characteristic findings of an SVA have not been reported. We describe a patient with an SVA found incidentally on an EUS that was performed for gastric antral ectopic pancreas. The diagnosis was based on the findings during EUS using an electronic radial scanning echoendoscope (EG-530UR; Fujifilm Corp., Saitama, Japan) with color Doppler flow-mapping capabilities. We identified a focally dilated distal splenic vein at the level of the pancreatic tail ([Fig. 1 a, b]), and a venous flow signal was detected by pulsed-wave Doppler ultrasound ([Fig. 1c]). Based on these findings, we diagnosed an SVA. Subsequent venous-phase three-dimensional computed tomography angiography (CTA) revealed a venous aneurysm on the splenic vein, confirming the final diagnosis of SVA ([Fig. 2]). Fig. 1 Endoscopic ultrasound (EUS) images of a splenic vein aneurysm using: a B-mode, which shows a localized dilatation of the splenic vein (large arrow) and the intact part of the splenic vein (small arrow); b color Doppler, which shows the blood flow in the lesion; c pulsed-wave Doppler, which shows continuous venous flow. A splenic artery aneurysm (SAA) is similar to an SVA in form and shape, and must be distinguished from an SVA. We previously reported the characteristic EUS findings of SAAs [1]. EUS using pulsed-wave Doppler mode shows a pulsating arterial wave in an SAA. In contrast, it shows continuous flow in an SVA. Therefore, we believe that the typical EUS findings of an SVA are focal dilatation of the splenic vein in B-mode images with continuous flow in the pulsed-wave Doppler mode. The best treatment strategy for incidentally detected asymptomatic SVAs remains controversial [2] [3]. We elected to monitor this lesion rather than perform surgery, and there was no change on either abdominal ultrasound or EUS at the 48-month follow-up. To our knowledge, this is the first reported case of an SVA diagnosed by EUS. Endoscopy_UCTN_Code_CCL_1AF_2AG_3AD


  • Ultrasound Catheter Probe (UCP)

    by Kazuya Akahoshi, Masaru Kubokawa

    • 1 December 2011
      • Vol. 108  (12) , 2030-5

    [A case of rectal implantation cyst diagnosed by EUS and EUS-guided FNA].

    by Soichi Itaba, Kazuya Akahoshi, Yasuaki Motomura, Risa Iwao, Yoshimasa Tanaka, Keishi Komori, Takashi Osoegawa, Masaru Kubokawa, Terumasa Hisano, Hiroshi Matono, et al.

    A 73-year-old woman was referred to our hospital complaining of bloody stool. She had undergone high anterior resection with the double stapling technique for a sigmoid colon cancer 2 years prior to this admission. Colonoscopy revealed a soft submucosal tumor, 4cm in size, on the anal side of the previous anastomosis in the rectum. EUS revealed a cystic lesion located in the third and fourth layers of the rectal wall. EUS-FNA was performed, and the content of the cystic lesion was transparent mucinous liquid. Histologically, the specimen revealed PAS and Alcian blue-positive mucinous material and a small number of inflammatory cells such as foamy macrophages. Therefore, this cystic lesion was diagnosed as a rectal implantation cyst.

    • 1 December 2011
      • Vol. 102  (12) , 333-40

    Is double-balloon colonoscopy a better aid to unskilled colonoscopists than conventional colonoscopy?

    by Risa Okamoto, Yasuaki Motomura, Kazuya Akahoshi, Yumi Kashiwabara, Shingo Endo, Naomi Higucchi, Manami Oda, Masaru Kubokawa, Noriaki Matsui, Kazuhiko Nakamura, et al.

    To compare the clinical outcome of double-balloon colonoscopy (DBC) with conventional colonoscopy (CC) for colon evaluation performed by an unskilled colonoscopist. Between June 2008 and November 2008, 1544 colonoscopies were performed in our hospital. Fifty-eight patients, (29 male and 29 female ; 19-86 years; mean age, 63 years) involving 60 intubations, were enrolled in this study and were assigned randomly to the DBC or CC group. One first-year GI fellow was enrolled and performed these 60 consecutive colonoscopies (30 DBCs, 30 CCs). Completion rate of colonoscopy, cecal intubation time, and rate of analgesic agent usage were analyzed. Completion of DBC was 100% (30/30), while completion of CC was 73% (22/30). There was a statistically significant difference (p < 0.05). The mean cecal intubation time was 36.2 +/- 14.4 minutes (DBC) and 36.5 +/- 15.2 minutes (CC). There was no statistically significant difference. Analgesic agent was used with 19 intubations (63%) (DBC) and with 27 intubations (90%) (CC) (p < 0.05). For inexpert endoscopists, using DBC has a higher rate of effectiveness than using CC and can decrease the discomfort of patients during colonoscopic procedures.

  • W1250 Effect of Nutritional Supplementation with Zinc and Vitamin C in Acute Hemorrhagic Rectal Ulcer Patients: A Randomized Clinical Trial

    by Yasuaki Motomura, Kazuya Akahoshi, Mihoko Yahiro, Masaru Kubokawa, Shingo Endo, Naomi Higuchi, Yumi Kashiwabara, Risa Okamoto, Manami Oda, Yuichiro Ishihara, et al.


    • 26 March 2009
      • Vol. 71  (4) , 418-22

    Eosinophilic gastroenteritis observed by double balloon enteroscopy and endoscopic ultrasonography in the whole gastrointestinal tract.

    by Atsuhiko Murata, Kazuya Akahoshi, Shinichi Kouzaki, Dai Ogata, Yasuaki Motomura, Noriaki Matsui, Masaru Kubokawa, Kuniomi Honda, Shingo Endo, Kazuhiko Nakamura

    Eosinophilic gastroenteritis is a chronic inflammatory disorder of the gastrointestinal tract characterized by the infiltration of eosinophils. It is a rare disease. There are no reports in the history of eosinophilic gastroenteritis being consecutively observed in the whole gastrointestinal tract by esophagogastroduodenoscopy (EGD), double-balloon enteroscopy (DBE), and endoscopic ultrasonography (EUS). A 66-year-old woman was admitted to our hospital because of abdominal pain and diarrhea. Laboratory findings included peripheral eosinophilia and a high serum immunoglobulin E level. We observed the whole gastrointestinal tract by EGD, DBE (antegrade and retrograde approaches), and EUS. DBE showed slightly edematous and reddish mucosa in the jejunum, ileum, and ascending colon, respectively. EUS in all portion of the gastrointestinal tract demonstrated almost normal five-layered structure without ascites. Histologic examination of the biopsy specimens from the stomach, duodenum, jejunum, ileum, colon and rectum revealed eosinophilic infiltration. No evidence of parasites, granulomas, malignancy, vasculitis or embolism was founded in any of the biopsy specimens. The patient was diagnosed with eosinophilic gastroenteritis with predominant mucosal layer form. She was treated with oral corticosteroid, and her symptoms subsided. To the best of our knowledge, this is the first case of eosinophilic gastroenteritis in which the whole gastrointestinal tract was consecutively observed by EGD, DBE, and EUS.