Christian Sodeikat
Research Interests
Christian Sodeikat has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Franz Knab
Ingenieurbüro Schiessl Gehlen Sodeikat GmbH Landsbergerstraße 370 80687 München
4 shared publications - Christoph Dauberschmidt
Munich University of Applied Sciences
2 shared publications - Philipp Obermeier
Ingenieurbüro Schiessl Gehlen Sodeikat GmbH Landsbergerstraße 370 80687 München
2 shared publications - Robin Groschup
Ingenieurbüro Schiessl Gehlen Sodeikat GmbH Landsbergerstraße 370 80687 München
2 shared publications Alexander Schoßmann
1 shared publication- Andreas Müller
Konstruktionsgruppe Bauen AG Ingenieurbüro für Bauwesen Bahnhofplatz 1 87435 Kempten / Allgäu
1 shared publication
Latest Publications
- 12 December 2019
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 115 (3) , 164-178
Die Gänstorbrücke in Ulm – Untersuchung, Probebelastung und Brückenmonitoring
Bei der 1950 in Ulm über die Donau errichteten Gänstorbrücke handelt es sich um eine der ältesten Spannbetonbrücken in Deutschland. Bereits bei Untersuchungen in den 1980er Jahren zeigte sich, dass Spanngliedhüllrohre unvollständig verpresst wurden, der Spannstahl Korrosionserscheinungen aufweist und lokal Chlorideintragungen in den Beton stattgefunden haben. Im Jahr 2018 wurden bei umfangreichen Bauwerksuntersuchungen erhebliche standsicherheitsrelevante Korrosionsschäden an Spanngliedern vorgefunden. Da eine vollumfängliche Zustandsprüfung aufgrund der großen Anzahl an Spanngliedern nicht mit vertretbarem Aufwand möglich ist und nicht ausgeschlossen werden kann, dass sich der Bauwerkszustand bis zur Realisierung eines Ersatzneubaus weiter verschlechtert, wurde ein Monitoringsystem installiert. Zur Kalibrierung des Messsystems und zur Festlegung von Warn‐ und Alarmwerten wurde eine Probebelastung mit definierten Verkehrslasten durchgeführt. Die Vorgehensweise bei den Untersuchungen, die Konzeptionierung der Probebelastung und des Monitoringsystems sowie wesentliche Ergebnisse werden im Rahmen des vorliegenden Beitrags vorgestellt.
- 12 December 2019
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 115 (3) , 164-178
Die Gänstorbrücke in Ulm – Untersuchung, Probebelastung und Brückenmonitoring
Bei der 1950 in Ulm über die Donau errichteten Gänstorbrücke handelt es sich um eine der ältesten Spannbetonbrücken in Deutschland. Bereits bei Untersuchungen in den 1980er Jahren zeigte sich, dass Spanngliedhüllrohre unvollständig verpresst wurden, der Spannstahl Korrosionserscheinungen aufweist und lokal Chlorideintragungen in den Beton stattgefunden haben. Im Jahr 2018 wurden bei umfangreichen Bauwerksuntersuchungen erhebliche standsicherheitsrelevante Korrosionsschäden an Spanngliedern vorgefunden. Da eine vollumfängliche Zustandsprüfung aufgrund der großen Anzahl an Spanngliedern nicht mit vertretbarem Aufwand möglich ist und nicht ausgeschlossen werden kann, dass sich der Bauwerkszustand bis zur Realisierung eines Ersatzneubaus weiter verschlechtert, wurde ein Monitoringsystem installiert. Zur Kalibrierung des Messsystems und zur Festlegung von Warn‐ und Alarmwerten wurde eine Probebelastung mit definierten Verkehrslasten durchgeführt. Die Vorgehensweise bei den Untersuchungen, die Konzeptionierung der Probebelastung und des Monitoringsystems sowie wesentliche Ergebnisse werden im Rahmen des vorliegenden Beitrags vorgestellt.
- 3 September 2019
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 114 (10) , 707-723
Acoustic Emission in der Bauwerksüberwachung zur Feststellung von Spannstahlbrüchen
Die Schallemissionsmessung Acoustic Emission (AE) ist ein Messverfahren, welches in der Materialforschung, in der Materialprüfung im Labor und in der Dauerüberwachung im Anlagen‐ und Maschinenbau seit Jahrzehnten erfolgreich eingesetzt wird. Im Bauwesen stellt die AE noch kein etabliertes bzw. übliches Messverfahren dar, auch wenn die Tauglichkeit des Verfahrens zur Detektion von Schadensereignissen in der Praxis mehrfach bewiesen wurde. In Deutschland unterliegen derzeit mehrere Brücken einer Dauerüberwachung, bei der AE einen wichtigen Baustein darstellt, um Veränderungen des Tragverhaltens bzw. eine zunehmende Schädigung in Form von Spannstahlbrüchen oder Schweißnahtrissen zu erfassen, z. B. [1]. AE zur Detektion von Spannstahlbrüchen empfiehlt sich bei Bauwerken mit spannungsrisskorrosionsempfindlichen Spannstählen, anderweitig korrosions‐ bzw. rissgefährdeten Spannstählen oder auch bei Neubauten, bei denen die Anforderungen an Bauwerksprüfungen nach DIN 1076 oder RIL 804 nicht eingehalten werden können. In diesem Beitrag werden Beispiele für AE‐Monitoring zur Spannstahlbruchdetektion an verschiedenen Bauwerken vorgestellt. Ferner werden Ergebnisse zu gezielt herbeigeführten Spannstahlbrüchen und Schlagbeanspruchung an Bauwerken und an Testkörpern dargestellt, ergänzt um zwei numerische Simulationen der Wellenausbreitung.
- 3 September 2019
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 114 (10) , 707-723
Acoustic Emission in der Bauwerksüberwachung zur Feststellung von Spannstahlbrüchen
Die Schallemissionsmessung Acoustic Emission (AE) ist ein Messverfahren, welches in der Materialforschung, in der Materialprüfung im Labor und in der Dauerüberwachung im Anlagen‐ und Maschinenbau seit Jahrzehnten erfolgreich eingesetzt wird. Im Bauwesen stellt die AE noch kein etabliertes bzw. übliches Messverfahren dar, auch wenn die Tauglichkeit des Verfahrens zur Detektion von Schadensereignissen in der Praxis mehrfach bewiesen wurde. In Deutschland unterliegen derzeit mehrere Brücken einer Dauerüberwachung, bei der AE einen wichtigen Baustein darstellt, um Veränderungen des Tragverhaltens bzw. eine zunehmende Schädigung in Form von Spannstahlbrüchen oder Schweißnahtrissen zu erfassen, z. B. [1]. AE zur Detektion von Spannstahlbrüchen empfiehlt sich bei Bauwerken mit spannungsrisskorrosionsempfindlichen Spannstählen, anderweitig korrosions‐ bzw. rissgefährdeten Spannstählen oder auch bei Neubauten, bei denen die Anforderungen an Bauwerksprüfungen nach DIN 1076 oder RIL 804 nicht eingehalten werden können. In diesem Beitrag werden Beispiele für AE‐Monitoring zur Spannstahlbruchdetektion an verschiedenen Bauwerken vorgestellt. Ferner werden Ergebnisse zu gezielt herbeigeführten Spannstahlbrüchen und Schlagbeanspruchung an Bauwerken und an Testkörpern dargestellt, ergänzt um zwei numerische Simulationen der Wellenausbreitung.
- Open Access
- 31 October 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 199, 06008
Corrosion on prestressing wires due to segregation of the injection mortar – Detection of injection defects with Ultrasonic-Echo Technique
Unsuitable granulometry of injection mortar can promote segregation if high hydrostatic pressure impacts on the mortar for longer time during hardening. Endangered for segregation are long perpendicular prestressing tendons e.g. used in high towers due to the high hydrostatic pressure inside. The segregation causes an accumulation of water and solved ions on top of the tendons. In this area an extremely high pH-value and a very low electrochemical potential occurs. This environment is extremely corrosive and can cause wire breaks within only few months. With the Ultrasonic-Echo Technique (Flaw Detectors) it is possible to detect injection defects by using the phase shift technique.
- 31 October 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 199, 06008
Open AccessCorrosion on prestressing wires due to segregation of the injection mortar – Detection of injection defects with Ultrasonic-Echo Technique
Unsuitable granulometry of injection mortar can promote segregation if high hydrostatic pressure impacts on the mortar for longer time during hardening. Endangered for segregation are long perpendicular prestressing tendons e.g. used in high towers due to the high hydrostatic pressure inside. The segregation causes an accumulation of water and solved ions on top of the tendons. In this area an extremely high pH-value and a very low electrochemical potential occurs. This environment is extremely corrosive and can cause wire breaks within only few months. With the Ultrasonic-Echo Technique (Flaw Detectors) it is possible to detect injection defects by using the phase shift technique.
- 3 August 2015
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 110 (8) , 539-553
Die Ermittlung der charakteristischen Betondruckfestigkeit von Bauwerken im Bestand
- 3 August 2015
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 110 (8) , 539-553
Die Ermittlung der charakteristischen Betondruckfestigkeit von Bauwerken im Bestand
- 1 July 2014
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 109 (7) , 453-462
Aufnahme von historischen Deckensystemen mit verschiedenen Methoden der zerstörungsfreien Prüfung ZfP
- 1 July 2014
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 109 (7) , 453-462
Aufnahme von historischen Deckensystemen mit verschiedenen Methoden der zerstörungsfreien Prüfung ZfP
- 2 May 2011
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 106 (5) , 325-331
Kathodischer Korrosionsschutz an Bauwerksfugen
- 2 May 2011
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 106 (5) , 325-331
Kathodischer Korrosionsschutz an Bauwerksfugen
- 5 November 2010
- Published by Wiley in Bautechnik
- Vol. 87 (11) , 724-735
Zur Instandsetzung aufgeschwommener Spannglieder an der Illerbrücke Thanners
- 5 November 2010
- Published by Wiley in Bautechnik
- Vol. 87 (11) , 724-735
Zur Instandsetzung aufgeschwommener Spannglieder an der Illerbrücke Thanners
- 26 July 2010
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 105 (8) , 529-538
Merkblatt B3 – Elektrochemische Potentialmessungen zur Detektion von Bewehrungsstahlkorrosion
Elektrochemische Potentialmessungen (auch Potentialfeldmessungen) haben sich seit Jahren bewährt, Bereiche mit aktiver chloridinduzierter Korrosion an tausalzexponierten Bauwerken, wie z. B. Brückentafeln sowie Zwischendecks und Bodenplatten von Parkhäusern und Tiefgaragen nachzuweisen.Bereits 1990 erschien die erste Fassung des Merkblatts B3 der DGZfP. Das DAfStb Heft 422 (1991) – Prüfung von Beton Empfehlungen und Hinweise zu DIN 1048 – enthielt die Potentialfeldmessung bzw. das Merkblatt B3 im Anhang. In Deutschland liegen somit zwei Jahrzehnte Erfahrungen mit den entsprechenden Regelwerken und natürlich auch in der praktischen Anwendung vor. In der Praxis zeigte sich jedoch auch, dass die Anwendung verbessert werden muss. Die Potentialmessung wurde vielfach sogar falsch durchgeführt, wichtige Messungen fehlten und auch die Interpretation bzw. Bewertung der Messergebnisse erfolgte nicht mit dem erforderlichen ingenieurmäßigen Sachverstand. Häufig erfolgte die Bewertung nur auf Grundlage des amerikanischen Regelwerks ASTM Standard C 876–91, welches sich auch aufgrund der unterschiedlichen Bauweisen in Deutschland jedoch nur sehr bedingt eignet. Dies und auch das Vorliegen neuer technischer und wissenschaftlicher Erkenntnisse veranlassten den DGZfP‐Fachausschuss für Zerstörungsfreie Prüfung im Bauwesen den Unterausschuss Korrosionsnachweis bei Stahlbeton zu beauftragen, das Merkblatt B3 zu überarbeiten und neu heraus zu geben. Das neue Merkblatt wurde schließlich im April 2008 veröffentlicht.Ziel des nachfolgenden Beitrags ist es, das Potentialmessverfahren in kurzer Form darzustellen, insbesondere jedoch das Merkblatt B3 der Fachöffentlichkeit vorzustellen, da sich immer wieder gezeigt hat, dass dieses Merkblatt bei Anwendern und Auftraggebern nur sehr wenig bekannt ist.Der Inhalt des Merkblatts B3 wird nachfolgend in Auszügen dargestellt, erläutert und Hinweise zur praktischen Ausführung und Bewertung der Potentialmessung gegeben. Ferner werden an einigen Stellen Hintergrundinformationen gegeben, die im Merkblatt B3 nicht enthalten sind. Auf neuere wissenschaftliche Erkenntnisse wird verwiesen. Die Kapiteleinteilung des Merkblatts B3 wird übernommen. Manche besonders wichtige Passagen des Merkblatts werden weitgehend wörtlich übernommen, wobei diese Passagen der besseren Lesbarkeit halber nicht extra gekennzeichnet werden.
- 26 July 2010
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 105 (8) , 529-538
Merkblatt B3 – Elektrochemische Potentialmessungen zur Detektion von Bewehrungsstahlkorrosion
Elektrochemische Potentialmessungen (auch Potentialfeldmessungen) haben sich seit Jahren bewährt, Bereiche mit aktiver chloridinduzierter Korrosion an tausalzexponierten Bauwerken, wie z. B. Brückentafeln sowie Zwischendecks und Bodenplatten von Parkhäusern und Tiefgaragen nachzuweisen.Bereits 1990 erschien die erste Fassung des Merkblatts B3 der DGZfP. Das DAfStb Heft 422 (1991) – Prüfung von Beton Empfehlungen und Hinweise zu DIN 1048 – enthielt die Potentialfeldmessung bzw. das Merkblatt B3 im Anhang. In Deutschland liegen somit zwei Jahrzehnte Erfahrungen mit den entsprechenden Regelwerken und natürlich auch in der praktischen Anwendung vor. In der Praxis zeigte sich jedoch auch, dass die Anwendung verbessert werden muss. Die Potentialmessung wurde vielfach sogar falsch durchgeführt, wichtige Messungen fehlten und auch die Interpretation bzw. Bewertung der Messergebnisse erfolgte nicht mit dem erforderlichen ingenieurmäßigen Sachverstand. Häufig erfolgte die Bewertung nur auf Grundlage des amerikanischen Regelwerks ASTM Standard C 876–91, welches sich auch aufgrund der unterschiedlichen Bauweisen in Deutschland jedoch nur sehr bedingt eignet. Dies und auch das Vorliegen neuer technischer und wissenschaftlicher Erkenntnisse veranlassten den DGZfP‐Fachausschuss für Zerstörungsfreie Prüfung im Bauwesen den Unterausschuss Korrosionsnachweis bei Stahlbeton zu beauftragen, das Merkblatt B3 zu überarbeiten und neu heraus zu geben. Das neue Merkblatt wurde schließlich im April 2008 veröffentlicht.Ziel des nachfolgenden Beitrags ist es, das Potentialmessverfahren in kurzer Form darzustellen, insbesondere jedoch das Merkblatt B3 der Fachöffentlichkeit vorzustellen, da sich immer wieder gezeigt hat, dass dieses Merkblatt bei Anwendern und Auftraggebern nur sehr wenig bekannt ist.Der Inhalt des Merkblatts B3 wird nachfolgend in Auszügen dargestellt, erläutert und Hinweise zur praktischen Ausführung und Bewertung der Potentialmessung gegeben. Ferner werden an einigen Stellen Hintergrundinformationen gegeben, die im Merkblatt B3 nicht enthalten sind. Auf neuere wissenschaftliche Erkenntnisse wird verwiesen. Die Kapiteleinteilung des Merkblatts B3 wird übernommen. Manche besonders wichtige Passagen des Merkblatts werden weitgehend wörtlich übernommen, wobei diese Passagen der besseren Lesbarkeit halber nicht extra gekennzeichnet werden.
- 4 December 2008
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 103 (12) , 819-827
Ultraschall‐Echo‐Verfahren und Impulsradar in der Praxisanwendung eines Ingenieurbüros
- 4 December 2008
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 103 (12) , 819-827
Ultraschall‐Echo‐Verfahren und Impulsradar in der Praxisanwendung eines Ingenieurbüros
- 30 November 2006
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 101 (12) , 932-942
Korrosionsmonitoring von Stahlbetonbauwerken für Public Private Partnership Projekte: Dauerhaftigkeit sichtbar gemacht
- 30 November 2006
- Published by Wiley in Beton- und Stahlbetonbau
- Vol. 101 (12) , 932-942
Korrosionsmonitoring von Stahlbetonbauwerken für Public Private Partnership Projekte: Dauerhaftigkeit sichtbar gemacht