Franck Brachelet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Franck Brachelet has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Didier Defer
Univ. Artois, Univ. Lille, Laboratoire de Génie Civil et géo-Environnement (LGCgE, France
11 shared publications - Sam Ang Keo
Cerema, Research Team ENDSUM, 23 Amiral Chauvin Avenue, 49130 Les Ponts-de-Cé, France
7 shared publications - Barbara Szymanik
Center for Electromagnetic Fields Engineering and High-Frequency Techniques, Faculty of Electrical Engineering, West Pomeranian University of Technology, 70-310 Szczecin, Poland
5 shared publications - Emmanuel Antczak
Univ. Artois, IMT Nord Europe, Junia, Univ. Lille, ULR 4515, Laboratoire de Génie Civil et Géo-Environnement (LGCgE), F-62400 Béthune, France
3 shared publications Université Bourgogne Europe
2 shared publications- Alexis Chauchois
« Textes et Cultures » (UR4028), Université d’Artois
1 shared publication
Latest Publications
- 1 November 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (11)
Applications of Active Infrared Thermography Methods in Civil Engineering : Reinforced Concrete and CFRP
The accessibility of active infrared thermography methods depends on the heating sources. The paper presents the application of three active infrared thermography methods in civil engineering. The first method with a Laser system was applied to detecting the absence of adhesive in CFRP which is commonly used for strengthening different structures (such as columns, beams, slabs). The second method with halogen lamps was also applied to detect the defect in CFRP. The last method with microwave heating source (frequency of 2.45 GHz) was applied to detect reinforcement bars in a reinforced concrete wall, and to detect the defect in CFRP. The results showed the efficiency of the active thermography methods for civil engineering structures. More particularly, the microwave thermography was also used to study the durablity (defects with aging) of the CFRP.
- 1 November 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (11)
Applications of Active Infrared Thermography Methods in Civil Engineering : Reinforced Concrete and CFRP
The accessibility of active infrared thermography methods depends on the heating sources. The paper presents the application of three active infrared thermography methods in civil engineering. The first method with a Laser system was applied to detecting the absence of adhesive in CFRP which is commonly used for strengthening different structures (such as columns, beams, slabs). The second method with halogen lamps was also applied to detect the defect in CFRP. The last method with microwave heating source (frequency of 2.45 GHz) was applied to detect reinforcement bars in a reinforced concrete wall, and to detect the defect in CFRP. The results showed the efficiency of the active thermography methods for civil engineering structures. More particularly, the microwave thermography was also used to study the durablity (defects with aging) of the CFRP.
- 1 November 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (11)
Enhancement of Detecting Reinforcement Cover by Microwave Thermography with Reflection Approach and radar method
The present study proposes the combinaison of radar method and microwave thermography method with reflection approach in order to enhance the detection of concrete cover. A methodology based experimental campaigns with microwave thermography allowed to determine the cover thickness of reinforcement bars (12 mm in diameter and regularly placed at 100 mm) in mortar wall (700 mm x 700 mm x 65 mm). The reflection approach with different angles of microwave antenna, and the Snell- Descartes law (which gives the relation between the incident waves, refracted waves, and the dielectric constant of the detected material), also led to deduce the approximate dielectric constant of the mortar. A GPR system was used to monitor the dielectric constant of the mortar during the infrared thermography tests. The combinaison of both electromagnetic methods clarified how the diffraction and interference affected the thermograms, led to validate a new outcome of detecting reinforcement cover by infrared thermography with reflection approach. It also opens perspectives to other studies on the state of the reinforcement cover which is sensitive to its dielectric constant.
- 1 November 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (11)
Enhancement of Detecting Reinforcement Cover by Microwave Thermography with Reflection Approach and radar method
The present study proposes the combinaison of radar method and microwave thermography method with reflection approach in order to enhance the detection of concrete cover. A methodology based experimental campaigns with microwave thermography allowed to determine the cover thickness of reinforcement bars (12 mm in diameter and regularly placed at 100 mm) in mortar wall (700 mm x 700 mm x 65 mm). The reflection approach with different angles of microwave antenna, and the Snell- Descartes law (which gives the relation between the incident waves, refracted waves, and the dielectric constant of the detected material), also led to deduce the approximate dielectric constant of the mortar. A GPR system was used to monitor the dielectric constant of the mortar during the infrared thermography tests. The combinaison of both electromagnetic methods clarified how the diffraction and interference affected the thermograms, led to validate a new outcome of detecting reinforcement cover by infrared thermography with reflection approach. It also opens perspectives to other studies on the state of the reinforcement cover which is sensitive to its dielectric constant.
- 13 September 2026
- Published by Springer Nature
- p. 450-460
Moisture Buffering Value of Multilayer Specimens with Composite Earthen Plasters Applied on Bio-Based and Conventional Materials
- 13 September 2026
- Published by Springer Nature
- p. 450-460
Moisture Buffering Value of Multilayer Specimens with Composite Earthen Plasters Applied on Bio-Based and Conventional Materials
- Open Access
- 29 November 2025
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 222
Experimental validation of an approach to reduce uncertainties in the in-situ estimation of straw bales' thermal conductivity
- 29 November 2025
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 222
Open AccessExperimental validation of an approach to reduce uncertainties in the in-situ estimation of straw bales' thermal conductivity
- Open Access
- 29 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (15) , 8419
Detection of Steel Reinforcement in Concrete Using Active Microwave Thermography and Neural Network-Based Analysis
Non-destructive evaluation of reinforced concrete structures is essential for effective maintenance and safety assessments. This study explores the combined use of active microwave thermography and deep learning to detect and localize steel reinforcement within concrete elements. Numerical simulations were developed to model the thermal response of reinforced concrete subjected to microwave excitation, generating synthetic thermal images representing the surface temperature patterns of reinforced concrete, influenced by subsurface steel reinforcement. These images served as training data for a deep neural network designed to identify and localize rebar positions based on thermal patterns. The model was trained exclusively on simulation data and subsequently validated using experimental measurements obtained from large-format concrete slabs incorporating a structured layout of embedded steel reinforcement bars. Surface temperature distributions obtained through infrared imaging were compared with model predictions to evaluate detection accuracy. The results demonstrate that the proposed method can successfully identify the presence and approximate location of internal reinforcement without damaging the concrete surface. This approach introduces a new pathway for contactless, automated inspection using a combination of physical modeling and data-driven analysis. While the current work focuses on rebar detection and localization, the methodology lays the foundation for broader applications in non-destructive testing of concrete infrastructure.
- 29 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (15) , 8419
Open AccessDetection of Steel Reinforcement in Concrete Using Active Microwave Thermography and Neural Network-Based Analysis
Non-destructive evaluation of reinforced concrete structures is essential for effective maintenance and safety assessments. This study explores the combined use of active microwave thermography and deep learning to detect and localize steel reinforcement within concrete elements. Numerical simulations were developed to model the thermal response of reinforced concrete subjected to microwave excitation, generating synthetic thermal images representing the surface temperature patterns of reinforced concrete, influenced by subsurface steel reinforcement. These images served as training data for a deep neural network designed to identify and localize rebar positions based on thermal patterns. The model was trained exclusively on simulation data and subsequently validated using experimental measurements obtained from large-format concrete slabs incorporating a structured layout of embedded steel reinforcement bars. Surface temperature distributions obtained through infrared imaging were compared with model predictions to evaluate detection accuracy. The results demonstrate that the proposed method can successfully identify the presence and approximate location of internal reinforcement without damaging the concrete surface. This approach introduces a new pathway for contactless, automated inspection using a combination of physical modeling and data-driven analysis. While the current work focuses on rebar detection and localization, the methodology lays the foundation for broader applications in non-destructive testing of concrete infrastructure.
- Open Access
- 20 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 4331
Investigation of Carbon Fiber Reinforced Polymer Concrete Reinforcement Ageing Using Microwave Infrared Thermography Method
This study presents the utilization of the microwave infrared thermography (MIRT) technique to identify and analyze the defects in the carbon-fiber-reinforced polymer (CFRP) composite reinforcement of concrete specimens. At first, a set of numerical models was created, comprising the broadband pyramidal horn antenna and the analyzed specimen. The utilization of the system operating at a power of 1000 W in a continuous mode, operating at frequency of 2.45 GHz, was analyzed. The specimen under examination comprised a compact concrete slab that was covered with an adhesive layer and, thereafter, topped with a layer of CFRP. An air gap represented a defect at the interface between the concrete and the CFRP within the adhesive layer. In the modeling stage, the study investigated three separate scenarios—a sample with no defects, a sample with a defect located at the center, and a sample with a numerous additional random defects located at the rim of the CFRP matte—to analyze the effect of the natural reinforcement degradation in this area. The next phase of the study involved conducting experiments to confirm the results obtained from numerical modeling. In the experiments, the concrete sample aged for 10 years with the defect in the center and naturally developed defects at the CFRP rim was used. The study employed numerical modeling to explore the phenomenon of microwave heating in complex structures. The aim was to assess the chosen antenna design and identify the most effective experimental setup. These conclusions were subsequently confirmed through experimentation. The observations made during the heating process were particularly remarkable since they deviated from earlier studies that solely conducted measurements of the sample post-heating phase. The findings demonstrate that MIRT has the capacity to be employed as a technique for detecting flaws in concrete structures reinforced with CFRP.
- 20 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 4331
Open AccessInvestigation of Carbon Fiber Reinforced Polymer Concrete Reinforcement Ageing Using Microwave Infrared Thermography Method
This study presents the utilization of the microwave infrared thermography (MIRT) technique to identify and analyze the defects in the carbon-fiber-reinforced polymer (CFRP) composite reinforcement of concrete specimens. At first, a set of numerical models was created, comprising the broadband pyramidal horn antenna and the analyzed specimen. The utilization of the system operating at a power of 1000 W in a continuous mode, operating at frequency of 2.45 GHz, was analyzed. The specimen under examination comprised a compact concrete slab that was covered with an adhesive layer and, thereafter, topped with a layer of CFRP. An air gap represented a defect at the interface between the concrete and the CFRP within the adhesive layer. In the modeling stage, the study investigated three separate scenarios—a sample with no defects, a sample with a defect located at the center, and a sample with a numerous additional random defects located at the rim of the CFRP matte—to analyze the effect of the natural reinforcement degradation in this area. The next phase of the study involved conducting experiments to confirm the results obtained from numerical modeling. In the experiments, the concrete sample aged for 10 years with the defect in the center and naturally developed defects at the CFRP rim was used. The study employed numerical modeling to explore the phenomenon of microwave heating in complex structures. The aim was to assess the chosen antenna design and identify the most effective experimental setup. These conclusions were subsequently confirmed through experimentation. The observations made during the heating process were particularly remarkable since they deviated from earlier studies that solely conducted measurements of the sample post-heating phase. The findings demonstrate that MIRT has the capacity to be employed as a technique for detecting flaws in concrete structures reinforced with CFRP.
- Open Access
- 16 April 2024
- Published by MDPI AG in Preprints.org
Investigation of CFRP Concrete Reinforcement Ageing Using Microwave Infrared Thermography Method (MIRT)
This study presents the utilization of the Microwave InfraRed Thermography (MIRT) technique to identify and analyze the defects in the carbon-fiber-reinforced polymer (CFRP) composite rein-forcement of concrete specimens. At first, a set of the numerical models was created, comprising of the broadband pyramidal horn antenna and the analyzed specimen. The utilization the system operating at a power of 1000W in a continuous mode, operating at frequency of 2.45 GHz was analyzed. The specimen under examination comprised a compact concrete slab that was covered with an adhesive layer, thereafter, topped with a layer of CFRP. An air gap represented a defect at the interface between the concrete and CFRP within the adhesive layer. In the modelling stage the study investigated three separate scenarios: a sample with no defects, a sample with a defect located at the center, and a sample with a numerous additional random defects located at the rim of the CFRP matte, to analyze the effect of the natural reinforcement degradation in this area. The next phase of the study involved conducting experiments to confirm the results obtained from nu-merical modeling. In the experiments the concrete sample aged for 10 years with the defect in the center and naturally developed defects at the CFRP rim was used. The study employed numerical modeling to explore the phenomenon of microwave heating in complex structures. The aim was to assess the chosen antenna design and identify the most effective experimental setup. These con-clusions were subsequently confirmed through experimentation. The observations made during the heating process were particularly remarkable, since they deviated from earlier studies that solely conducted measurements of the sample post-heating phase. The findings demonstrate that MIRT has the capacity to be employed as a technique for detecting flaws in concrete structures reinforced with CFRP.
- 16 April 2024
- Published by MDPI AG in Preprints.org
Open AccessInvestigation of CFRP Concrete Reinforcement Ageing Using Microwave Infrared Thermography Method (MIRT)
This study presents the utilization of the Microwave InfraRed Thermography (MIRT) technique to identify and analyze the defects in the carbon-fiber-reinforced polymer (CFRP) composite rein-forcement of concrete specimens. At first, a set of the numerical models was created, comprising of the broadband pyramidal horn antenna and the analyzed specimen. The utilization the system operating at a power of 1000W in a continuous mode, operating at frequency of 2.45 GHz was analyzed. The specimen under examination comprised a compact concrete slab that was covered with an adhesive layer, thereafter, topped with a layer of CFRP. An air gap represented a defect at the interface between the concrete and CFRP within the adhesive layer. In the modelling stage the study investigated three separate scenarios: a sample with no defects, a sample with a defect located at the center, and a sample with a numerous additional random defects located at the rim of the CFRP matte, to analyze the effect of the natural reinforcement degradation in this area. The next phase of the study involved conducting experiments to confirm the results obtained from nu-merical modeling. In the experiments the concrete sample aged for 10 years with the defect in the center and naturally developed defects at the CFRP rim was used. The study employed numerical modeling to explore the phenomenon of microwave heating in complex structures. The aim was to assess the chosen antenna design and identify the most effective experimental setup. These con-clusions were subsequently confirmed through experimentation. The observations made during the heating process were particularly remarkable, since they deviated from earlier studies that solely conducted measurements of the sample post-heating phase. The findings demonstrate that MIRT has the capacity to be employed as a technique for detecting flaws in concrete structures reinforced with CFRP.
- Open Access
- 20 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (14) , 8393
Defect Detection in CFRP Concrete Reinforcement Using the Microwave Infrared Thermography (MIRT) Method—A Numerical Modeling and Experimental Approach
This research paper presents the application of the microwave infrared thermography (MIRT) technique for the purpose of detecting and characterizing defects in the carbon-fiber-reinforced polymer (CFRP) composite reinforcement of concrete specimens. Initially, a numerical model was constructed, which consisted of a broadband pyramidal horn antenna and the specimen. The present study investigated the application of a 360 W power system that operated at a frequency of 2.4 GHz, specifically focusing on two different operational modes: continuous and modulated. The specimen being examined consisted of a solid concrete slab that was coated with an adhesive layer, which was then overlaid with a layer of CFRP. Within the adhesive layer, at the interface between the concrete and CFRP, there was a defect in the form of an air gap. The study examined three distinct scenarios: a sample without any defects, a sample with a defect positioned at the center, and a sample with a defect positioned outside the center. The subsequent stage of the investigation incorporated experimental verification of the numerical modeling results. The experiment involved the utilization of two concrete specimens reinforced using CFRP, one without any defects and the other with a defect. Numerical modeling was used in this study to analyze the phenomenon of microwave heating in complex structures. The objective was to evaluate the selected antenna geometry and determine the optimal experimental configuration. Subsequently, these findings were experimentally validated. The observations conducted during the heating phase were particularly noteworthy, as they differed from previous studies that only performed observation of the sample after the heating phase. The results show that MIRT has the potential to be utilized as a method for identifying defects in concrete structures that are reinforced with CFRP.
- 20 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (14) , 8393
Open AccessDefect Detection in CFRP Concrete Reinforcement Using the Microwave Infrared Thermography (MIRT) Method—A Numerical Modeling and Experimental Approach
This research paper presents the application of the microwave infrared thermography (MIRT) technique for the purpose of detecting and characterizing defects in the carbon-fiber-reinforced polymer (CFRP) composite reinforcement of concrete specimens. Initially, a numerical model was constructed, which consisted of a broadband pyramidal horn antenna and the specimen. The present study investigated the application of a 360 W power system that operated at a frequency of 2.4 GHz, specifically focusing on two different operational modes: continuous and modulated. The specimen being examined consisted of a solid concrete slab that was coated with an adhesive layer, which was then overlaid with a layer of CFRP. Within the adhesive layer, at the interface between the concrete and CFRP, there was a defect in the form of an air gap. The study examined three distinct scenarios: a sample without any defects, a sample with a defect positioned at the center, and a sample with a defect positioned outside the center. The subsequent stage of the investigation incorporated experimental verification of the numerical modeling results. The experiment involved the utilization of two concrete specimens reinforced using CFRP, one without any defects and the other with a defect. Numerical modeling was used in this study to analyze the phenomenon of microwave heating in complex structures. The objective was to evaluate the selected antenna geometry and determine the optimal experimental configuration. Subsequently, these findings were experimentally validated. The observations conducted during the heating phase were particularly noteworthy, as they differed from previous studies that only performed observation of the sample after the heating phase. The results show that MIRT has the potential to be utilized as a method for identifying defects in concrete structures that are reinforced with CFRP.
- Open Access
- 30 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (19) , 9865
Detection of Concrete Cover of Reinforcements in Reinforced Concrete Wall by Microwave Thermography with Transmission Approach
Concrete cover has an important role in reinforced concrete (RC) structures because it protects reinforcement bars from the bad effects of weather, fire, and bad environmental conditions that cause the corrosion of the reinforcements. Although it is an essential parameter to be considered for structural health monitoring (SHM), its detection by infrared thermography, especially in the heating phase, has not been accessed yet. The detailed analysis and discussions of physical phenomena, known as diffraction and interference, affecting the thermograms during the detection of the steel bars by microwave thermography have given an essential key for resolving this issue. The present paper proposes an innovative methodology with microwave thermography for determining the concrete cover thickness of one-layer reinforcements (12 mm in diameter and regularly placed at 10 cm) in an RC wall (1 m × 1 m × 6.5 cm). By using the transmission approach with five angles of microwave antenna direction (0°, 15°, 30°, 45°, and 60°) and the Snell–Descartes law and linear law, the proposed methodology leads us to deduce the approximate value of the concrete cover thickness (37.74 mm), which is close to the real value (38 mm), as well as the spacing of the steel bars and dielectric constant of the concrete. The detection of the concrete cover thickness is another new remarkable achievement of infrared thermography methods.
- 30 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (19) , 9865
Open AccessDetection of Concrete Cover of Reinforcements in Reinforced Concrete Wall by Microwave Thermography with Transmission Approach
Concrete cover has an important role in reinforced concrete (RC) structures because it protects reinforcement bars from the bad effects of weather, fire, and bad environmental conditions that cause the corrosion of the reinforcements. Although it is an essential parameter to be considered for structural health monitoring (SHM), its detection by infrared thermography, especially in the heating phase, has not been accessed yet. The detailed analysis and discussions of physical phenomena, known as diffraction and interference, affecting the thermograms during the detection of the steel bars by microwave thermography have given an essential key for resolving this issue. The present paper proposes an innovative methodology with microwave thermography for determining the concrete cover thickness of one-layer reinforcements (12 mm in diameter and regularly placed at 10 cm) in an RC wall (1 m × 1 m × 6.5 cm). By using the transmission approach with five angles of microwave antenna direction (0°, 15°, 30°, 45°, and 60°) and the Snell–Descartes law and linear law, the proposed methodology leads us to deduce the approximate value of the concrete cover thickness (37.74 mm), which is close to the real value (38 mm), as well as the spacing of the steel bars and dielectric constant of the concrete. The detection of the concrete cover thickness is another new remarkable achievement of infrared thermography methods.
- Open Access
Active Thermal Method Applied to the In Situ Characterization of Insulating Materials in a Wall
An in situ estimation of the thermal properties of bio-sourced building wall insulation components is of critical importance in improving both the energy efficiency of buildings and the development of construction materials with a smaller environmental footprint. Depending on weather conditions, passive methods are not always feasible; they require time to conduct lengthy testing and may lead to significant uncertainties. This article presents an active method based on power dissipation via flat electrical resistance. The method can be implemented regardless of outdoor weather conditions and is suitable for walls with high overall thermal resistance for which the small average component of the through flow is difficult to estimate. Measurements are conducted of both wall input flows and temperatures. An inverse method, derived from a finite difference model of 1D transfers along with a multi-objective approach, enables the characteristics of a two-material assembly to be identified. A multi-objective method was chosen to solve the problems of high correlation between the thermal parameters of the model. However, the method requires the use of two temperature sensors integrated inside the wall. Following a laboratory validation phase on a PVC/plasterboard assembly, the method is implemented on an actual wall. A coating/hemp concrete assembly is also characterized as part of this work program. The thermal conductivity of the hemp concrete block was estimated at 0.12 W m−1 K−1 and is consistent with values found in the literature.
Open AccessActive Thermal Method Applied to the In Situ Characterization of Insulating Materials in a Wall
An in situ estimation of the thermal properties of bio-sourced building wall insulation components is of critical importance in improving both the energy efficiency of buildings and the development of construction materials with a smaller environmental footprint. Depending on weather conditions, passive methods are not always feasible; they require time to conduct lengthy testing and may lead to significant uncertainties. This article presents an active method based on power dissipation via flat electrical resistance. The method can be implemented regardless of outdoor weather conditions and is suitable for walls with high overall thermal resistance for which the small average component of the through flow is difficult to estimate. Measurements are conducted of both wall input flows and temperatures. An inverse method, derived from a finite difference model of 1D transfers along with a multi-objective approach, enables the characteristics of a two-material assembly to be identified. A multi-objective method was chosen to solve the problems of high correlation between the thermal parameters of the model. However, the method requires the use of two temperature sensors integrated inside the wall. Following a laboratory validation phase on a PVC/plasterboard assembly, the method is implemented on an actual wall. A coating/hemp concrete assembly is also characterized as part of this work program. The thermal conductivity of the hemp concrete block was estimated at 0.12 W m−1 K−1 and is consistent with values found in the literature.