DSDevin M. Stoker

Devin M. Stoker

*This is an algorithmically generated author record based on publicly available information.

Devin M. Stoker has a total of 2 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ultrasonic Flow Measurement for Pipe Installations with Nonideal Conditions

    by Devin M. Stoker, Steven L. Barfuss, Michael C. Johnson

    In the arid Western United States, water is among the most valuable resources. Typically, to successfully and accurately measure a flow rate using most types of flow meters, it is recommended that a straight section of pipe be installed immediately upstream from the flow meter to avoid distorted flow patterns and extreme turbulence at the metering location. In many field piping situations, however, such flow conditions are impossible to achieve. The portable ultrasonic flow meter (USFM) is a commonly used flow meter for field flow measurements in closed conduits and emits two ultrasonic signals across the cross section of pipe. One signal travels with the direction of the flow, and the other travels against the flow. The difference in signal travel time is then used along with the known geometry of the pipe to calculate the average flow velocity of the fluid. The performance of an USFM in nonideal piping scenarios was studied using laboratory experiments and numerical computational fluid dynamics ...