Francine Monchau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Francine Monchau has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
A. Lefevre
2 shared publicationsM. Descamps
Laboratoire des Matériaux Céramiques et Procédés Associés (EA 2443, Université Lille Nord de France), Université de Valenciennes et du Hainaut-Cambrésis, ZI du Champ de l'Abbesse, 59600 Maubeuge, France
2 shared publicationsA Lefevre
1 shared publicationAlain Jouanneaux
Institut des Molécules et des Matériaux du Mans (IMMM), UMR-CNRS no 6283, Le Mans Université, avenue O. Messiaen, 72085, Le Mans, France
1 shared publicationB. Genestie
Laboratoire Génie Civil et géo-Environnement (EA 4515, Université Lille Nord de France), Equipe Biomatériaux Artois (Université d'Artois), IUT/GMP, 1230, rue de l'Université, BP 819, 62408 Béthune cedex, France
1 shared publication- Benoit Genestie
Univ. Artois, LGCgE, EA 4515, IUT Béthune, Béthune, France
1 shared publication
Latest Publications
- 1 October 2020
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 110, 103886
Optimization of the formulation of an original hydrogel-based bone cement using a mixture design
- 1 October 2020
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 110, 103886
Optimization of the formulation of an original hydrogel-based bone cement using a mixture design
- 17 May 2016
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 38 (8) , 733-740
Numerical and ex vivo studies of a bioprobe developed for laser-induced thermotherapy (LITT) in contact with liver tissue
This work is based on the production of a bioprobe that is compatible with magnetic resonance imaging (MRI) for laser-induced thermotherapy (LITT) in liver cancer laser therapy. This probe is made of an alumina tube (3-mm diameter) in which an optical fibre is centred and fixed. A shooting window (20mm) is created using a mechanical rectifier. The device is then consolidated by the injection of a transparent and heat-resistant resin. Through numerical modelling, the thermal power damping of the laser source is evaluated as well as the propagation of the heat in the ex vivo liver tissue according to different heating scenarios. These analyses allow for an estimation of the irradiated volume. Ex vivo tests were performed on bovine liver to confirm the adequacy of the bioprobe for LITT and of the irradiated volumes predicted by the numerical model. There was a difference of 8% between the simulations and ex vivo experiments. The pulsed mode heating scenario was the most effective under the experimental conditions.
- 17 May 2016
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 38 (8) , 733-740
Numerical and ex vivo studies of a bioprobe developed for laser-induced thermotherapy (LITT) in contact with liver tissue
This work is based on the production of a bioprobe that is compatible with magnetic resonance imaging (MRI) for laser-induced thermotherapy (LITT) in liver cancer laser therapy. This probe is made of an alumina tube (3-mm diameter) in which an optical fibre is centred and fixed. A shooting window (20mm) is created using a mechanical rectifier. The device is then consolidated by the injection of a transparent and heat-resistant resin. Through numerical modelling, the thermal power damping of the laser source is evaluated as well as the propagation of the heat in the ex vivo liver tissue according to different heating scenarios. These analyses allow for an estimation of the irradiated volume. Ex vivo tests were performed on bovine liver to confirm the adequacy of the bioprobe for LITT and of the irradiated volumes predicted by the numerical model. There was a difference of 8% between the simulations and ex vivo experiments. The pulsed mode heating scenario was the most effective under the experimental conditions.
- 1 January 2013
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 33 (1) , 490-498
Calcite as a bone substitute. Comparison with hydroxyapatite and tricalcium phosphate with regard to the osteoblastic activity
- 1 January 2013
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 33 (1) , 490-498
Calcite as a bone substitute. Comparison with hydroxyapatite and tricalcium phosphate with regard to the osteoblastic activity
- Open Access
- 1 January 2005
- Published by Walter de Gruyter GmbH in BIOmaterialien
- Vol. 6 (4) , 281-286
Osteoclast behaviour on synthetic bioglasses with different crystallinity in vitro
- 1 January 2005
- Published by Walter de Gruyter GmbH in BIOmaterialien
- Vol. 6 (4) , 281-286
Open AccessOsteoclast behaviour on synthetic bioglasses with different crystallinity in vitro
- 6 June 2003
- Vol. 44 (3) , 73-82
Biological characterization of experimental carbon samples.
The use of carbon is widespread in fields as wide as aeronautics, cars, electricity or electronics. The biomedical applications of carbon are also numerous. The purpose of our work is to test four experimental carbon fibers (A, B, C and D; B being the negative control) to determine the best clinical application. Four tests of cytocompatibility are carried out (cell viability, inflammatory test, cell proliferation and cell morphology). Two different cell lines are used: the L132 cell line (epithelial embryonic pulmonary human cell) and the HaCaT line (human normal spontaneously immortalized skin keratinocytes). The results of the biological tests are compared with those of a carbon fiber sample already marketed as a bandage in the treatment of infected wounds: Actisorb "Plus (J2). The various tests show us that only two experimental samples are slightly cytotoxic (A, D). On the other hand, no sample supports cell adherence. A, B, C and D do not have an inflammatory effect. J2 appears at the same time cytotoxic and inflammatory. Consequently, being given the physical presentation and the biological properties of experimental samples (A, C and D), we intend them for an application in the field of wound healing, as a bandage. Also further experimentation is needed.
- 6 June 2003
- Vol. 44 (3) , 73-82
Biological characterization of experimental carbon samples.
The use of carbon is widespread in fields as wide as aeronautics, cars, electricity or electronics. The biomedical applications of carbon are also numerous. The purpose of our work is to test four experimental carbon fibers (A, B, C and D; B being the negative control) to determine the best clinical application. Four tests of cytocompatibility are carried out (cell viability, inflammatory test, cell proliferation and cell morphology). Two different cell lines are used: the L132 cell line (epithelial embryonic pulmonary human cell) and the HaCaT line (human normal spontaneously immortalized skin keratinocytes). The results of the biological tests are compared with those of a carbon fiber sample already marketed as a bandage in the treatment of infected wounds: Actisorb "Plus (J2). The various tests show us that only two experimental samples are slightly cytotoxic (A, D). On the other hand, no sample supports cell adherence. A, B, C and D do not have an inflammatory effect. J2 appears at the same time cytotoxic and inflammatory. Consequently, being given the physical presentation and the biological properties of experimental samples (A, C and D), we intend them for an application in the field of wound healing, as a bandage. Also further experimentation is needed.
- Open Access
- 1 January 2001
- Published by Walter de Gruyter GmbH in BIOmaterialien
- Vol. 2 (4) , 163-169
In-vitro-Degradation von Biokeramiken
- 1 January 2001
- Published by Walter de Gruyter GmbH in BIOmaterialien
- Vol. 2 (4) , 163-169
Open AccessIn-vitro-Degradation von Biokeramiken