Loïc J. Blum
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Loïc J. Blum has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Christophe André Marquette
Université Lyon 1, CNRS, ICBMS, 3d.FAB Villeurbanne France
6 shared publications - Béatrice D. Leca-Bouvier
Université de Lyon, Université Lyon 1, CNRS, UMR5246, Institut de Chimie et Biochimie Moléculaires et Supramoléculaires, Laboratoire de Génie Enzymatique et Biomoléculaire, F-69622, Villeurbanne Cedex, France
3 shared publications Christophe A. Marquette
Equipe Génie Enzymatique, Membranes Biomimétiques et Assemblages Supramoléculaires, Institut de Chimie et Biochimie Moléculaires et Supramoléculaires, UMR5246 Université Lyon 1–CNRS, 43 boulevard du 11 novembre 1918, Villeurbanne, 69622, France
2 shared publicationsAgnès Degiuli
Université Lyon 1, 43 bd du 11 novembre 1918
1 shared publicationAgnès M. Verdier
Laboratoire de Génie Enzymatique, UMR CNRS 5013, Université Claude Bernard Lyon 1–43, bd du 11 Novembre 1918, 69622 Villeurbanne Cedex, France
1 shared publicationAlain Laurent
BioMérieux, Parc Polytec. 5 rue des Berges, 38024 Grenoble, France
1 shared publication
Latest Publications
- 12 September 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 241, 115689
User-friendly one-step disposable signal-on bioassay for glyphosate detection in water samples
- 12 September 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 241, 115689
User-friendly one-step disposable signal-on bioassay for glyphosate detection in water samples
- Open Access
- 27 March 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (4) , 102
3D–4D Printed Objects: New Bioactive Material Opportunities
One of the main objectives of 3D printing in health science is to mimic biological functions. To reach this goal, a 4D printing might be added to 3D-printed objects which will be characterized by their abilities to evolve over time and under external stimulus by modifying their shape, properties or composition. Such abilities are the promise of great opportunities for biosensing and biomimetic systems to progress towards more physiological mimicking systems. Herein are presented two 4D printing examples for biosensing and biomimetic applications using 3D-printed enzymes. The first one is based on the printing of the enzymatic couple glucose oxidase/peroxidase for the chemiluminescent detection of glucose, and the second uses printed alkaline phosphatase to generate in situ programmed and localized calcification of the printed object.
- 27 March 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (4) , 102
Open Access3D–4D Printed Objects: New Bioactive Material Opportunities
One of the main objectives of 3D printing in health science is to mimic biological functions. To reach this goal, a 4D printing might be added to 3D-printed objects which will be characterized by their abilities to evolve over time and under external stimulus by modifying their shape, properties or composition. Such abilities are the promise of great opportunities for biosensing and biomimetic systems to progress towards more physiological mimicking systems. Herein are presented two 4D printing examples for biosensing and biomimetic applications using 3D-printed enzymes. The first one is based on the printing of the enzymatic couple glucose oxidase/peroxidase for the chemiluminescent detection of glucose, and the second uses printed alkaline phosphatase to generate in situ programmed and localized calcification of the printed object.
- 20 February 2013
- Published by Wiley in Macromolecular Bioscience
- Vol. 13 (2) , 141
Macromol. Biosci. 2/2013
- 20 February 2013
- Published by Wiley in Macromolecular Bioscience
- Vol. 13 (2) , 141
Macromol. Biosci. 2/2013
- 31 July 2009
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 395 (2) , 241-242
Jeffrey B.-H. Tok (Ed.): Nano and microsensors for chemical and biological terrorism surveillance
- 31 July 2009
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 395 (2) , 241-242
Jeffrey B.-H. Tok (Ed.): Nano and microsensors for chemical and biological terrorism surveillance
- 19 July 2009
- Published by Springer Nature
- p. 871-909
Biosensors. From the Glucose Electrode to the Biochip
- 19 July 2009
- Published by Springer Nature
- p. 871-909
Biosensors. From the Glucose Electrode to the Biochip
- 16 May 2007
- Published by Wiley in Angewandte Chemie
- Vol. 119 (22) , 4186-4188
A Versatile Method for Direct and Covalent Immobilization of DNA and Proteins on Biochips
- 16 May 2007
- Published by Wiley in Angewandte Chemie
- Vol. 119 (22) , 4186-4188
A Versatile Method for Direct and Covalent Immobilization of DNA and Proteins on Biochips
- 6 April 2001
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 74 (1-3) , 190-193
Screen-printed electrodes as disposable or reusable optical devices for luminol electrochemiluminescence
- 6 April 2001
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 74 (1-3) , 190-193
Screen-printed electrodes as disposable or reusable optical devices for luminol electrochemiluminescence
- 1 March 2001
- Published by Wiley in Luminescence
- Vol. 16 (2) , 159-165
Electrogenerated chemiluminescence of luminol for oxidase‐based fibre‐optic biosensors
- 1 March 2001
- Published by Wiley in Luminescence
- Vol. 16 (2) , 159-165
Electrogenerated chemiluminescence of luminol for oxidase‐based fibre‐optic biosensors
- 7 January 2000
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 125 (1) , 151-155
An electrochemiluminescence-based fibre optic biosensor for choline flow injection analysis
A fibre optic biosensor based on luminol electrochemiluminescence (ECL) integrated in a flow injection analysis (FIA) system was developed for the detection of choline. The electrochemiluminescence of luminol was generated by a glassy carbon electrode polarised at +425 mV vs. a platinum pseudo-reference electrode. Choline oxidase (Chx) was immobilised either covalently on polyamide (ABC type) or on UltraBind preactivated membranes, or by physical entrapment in a photo-cross-linkable poly(vinyl alcohol) polymer (PVA-SbQ) alone or after absorption on a weak anion exchanger, DEAE (diethylaminoethyl) Sepharose. The optimisation of the reaction conditions and physicochemical parameters influencing the FIA biosensor response demonstrated that the choline biosensor exhibited the best performances in a 30 mM veronal buffer containing 30 mM KCl and 1.5 mM MgCl2, at pH 9. The use of a 0.5 ml min−1 flow rate enabled the measurement of choline by the membrane-based ECL biosensors in 8 or 5 min, with ABC or UltraBind membranes, respectively, whereas the measurement required only 3 min with the DEAE–PVA system. For comparison, the detection of choline was performed with Chx immobilised using the four different supports. The best performances were obtained with the DEAE–PVA–Chx sensing layer, which allowed a detection limit of 10 pmol, whereas with the ABC, the UltraBind and the PVA systems, the detection limits were 300 pmol, 75 pmol and 220 pmol, respectively. The DEAE-based system also exhibited a good operational stability since 160 repeated measurements of 3 nmol of choline could be performed with an RSD of 4.5% whereas the stability under the best conditions was 45 assays with the other supports.
- 7 January 2000
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 125 (1) , 151-155
An electrochemiluminescence-based fibre optic biosensor for choline flow injection analysis
A fibre optic biosensor based on luminol electrochemiluminescence (ECL) integrated in a flow injection analysis (FIA) system was developed for the detection of choline. The electrochemiluminescence of luminol was generated by a glassy carbon electrode polarised at +425 mV vs. a platinum pseudo-reference electrode. Choline oxidase (Chx) was immobilised either covalently on polyamide (ABC type) or on UltraBind preactivated membranes, or by physical entrapment in a photo-cross-linkable poly(vinyl alcohol) polymer (PVA-SbQ) alone or after absorption on a weak anion exchanger, DEAE (diethylaminoethyl) Sepharose. The optimisation of the reaction conditions and physicochemical parameters influencing the FIA biosensor response demonstrated that the choline biosensor exhibited the best performances in a 30 mM veronal buffer containing 30 mM KCl and 1.5 mM MgCl2, at pH 9. The use of a 0.5 ml min−1 flow rate enabled the measurement of choline by the membrane-based ECL biosensors in 8 or 5 min, with ABC or UltraBind membranes, respectively, whereas the measurement required only 3 min with the DEAE–PVA system. For comparison, the detection of choline was performed with Chx immobilised using the four different supports. The best performances were obtained with the DEAE–PVA–Chx sensing layer, which allowed a detection limit of 10 pmol, whereas with the ABC, the UltraBind and the PVA systems, the detection limits were 300 pmol, 75 pmol and 220 pmol, respectively. The DEAE-based system also exhibited a good operational stability since 160 repeated measurements of 3 nmol of choline could be performed with an RSD of 4.5% whereas the stability under the best conditions was 45 assays with the other supports.
- 1 January 2000
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 89 (2-3) , 107-116
Fiberoptic Biosensors Based on Chemiluminescent Reactions
The chemiluminescence of luminol in the presence of H2O2has been exploited to develop fiberoptic biosensors associated with flow injection analysis systems. A chlorophenol sensor was developed based...
- 1 January 2000
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 89 (2-3) , 107-116
Fiberoptic Biosensors Based on Chemiluminescent Reactions
The chemiluminescence of luminol in the presence of H2O2has been exploited to develop fiberoptic biosensors associated with flow injection analysis systems. A chlorophenol sensor was developed based...