SJSteven Amos Jones

Steven Amos Jones

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Steven Amos Jones has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Flexible Nano-Platinum Microelectrode Arrays for Sensitive and Spatially Resolved Nitric Oxide Monitoring

    by Umisha Siwakoti, Oshima Shah, Manoj Pandit, Kyle Rugg, Mark A. DeCoster, Steven Amos Jones, Elisa Castagnola

    Nitric oxide (NO) regulates neuronal signaling and neurovascular function, but its rapid diffusion, short lifetime, and reactivity complicate real-time detection in tissue. We developed flexible platinum microelectrode arrays (MEAs) modified with nanostructured platinum (nano-Pt) and a permselective poly(m-phenylenediamine) (mPD) coating for sensitive, selective NO monitoring. Nano-Pt electrodeposition reduced impedance approximately eightfold at 10 Hz and increased charge-storage capacity approximately 7.4-fold without increasing electrode dimensions. Simultaneous amperometric recordings from multiple electrode channels demonstrated the multisite sensing proof of concept of the flexible MEA platform. Amperometric calibration showed linear responses from 50 to 250 nM (R2 > 0.999), with a sensitivity of 243.16 ± 6.12 pA/µM and an operational detection limit of 50 nM. The mPD coating attenuated responses to ascorbic acid, uric acid, and dopamine. Sensors retained NO sensitivity (180 ± 8.6 pA/µM) in endothelial cell culture medium and detected transients following exposure of primary brain microvascular endothelial cells to copper-containing high-aspect-ratio structures (CuHARS), corresponding to peak NO-equivalent concentrations of 320 ± 50 nM. In mouse hippocampus, local NMDA/glycine administration evoked responses corresponding to estimated NO concentrations of 154 ± 31 nM. Finite-element simulations predicted detectable NO concentration gradients across neighboring electrode sites. These results support flexible nano-Pt/mPD MEAs for NO monitoring in complex biological environments and motivate experimental validation of spatially resolved measurements.

  • Open Access

    Recent Progress in Flexible Microelectrode Arrays for Combined Electrophysiological and Electrochemical Sensing

    by Umisha Siwakoti, Steven A. Jones, Deepak Kumbhare, Xinyan Tracy Cui, Elisa Castagnola

    Understanding brain function requires advanced neural probes to monitor electrical and chemical signaling across multiple timescales and brain regions. Microelectrode arrays (MEAs) are widely used to record neurophysiological activity across various depths and brain regions, providing single-unit resolution for extended periods. Recent advancements in flexible MEAs, built on micrometer-thick polymer substrates, have improved integration with brain tissue by mimicking the brain’s soft nature, reducing mechanical trauma and inflammation. These flexible, subcellular-scale MEAs can record stable neural signals for months, making them ideal for long-term studies. In addition to electrical recording, MEAs have been functionalized for electrochemical neurotransmitter detection. Electroactive neurotransmitters, such as dopamine, serotonin, and adenosine, can be directly measured via electrochemical methods, particularly on carbon-based surfaces. For non-electroactive neurotransmitters like acetylcholine, glutamate, and γ-aminobutyric acid, alternative strategies, such as enzyme immobilization and aptamer-based recognition, are employed to generate electrochemical signals. This review highlights recent developments in flexible MEA fabrication and functionalization to achieve both electrochemical and electrophysiological recordings, minimizing sensor fowling and brain damage when implanted long-term. It covers multi-time scale neurotransmitter detection, development of conducting polymer and nanomaterial composite coatings to enhance sensitivity, incorporation of enzyme and aptamer-based recognition methods, and the integration of carbon electrodes on flexible MEAs. Finally, it summarizes strategies to acquire electrochemical and electrophysiological measurements from the same device.


  • Open Access

    Recent Progress in Flexible Microelectrode Arrays for Combined Electrophysiological and Electrochemical Sensing

    by Umisha Siwakoti, Steven A. Jones, Deepak Kumbhare, Xinyan Tracy Cui, Elisa Castagnola

    Understanding brain function requires advanced neural probes to monitor electrical and chemical signaling across multiple timescales and brain regions. Microelectrode arrays (MEAs) are widely used to record neurophysiological activity across various depths and brain regions, providing single-unit resolution for extended periods. Recent advancements in flexible MEAs, built on micrometer-thick polymer substrates, have improved integration with brain tissue by mimicking the brain's soft nature, reducing mechanical trauma and inflammation. These flexible, subcellular-scale MEAs can record stable neural signals for months, making them ideal for long-term studies. In addition to electrical recording, MEAs have been functionalized for electrochemical neurotransmitter detection. Electroactive neurotransmitters, such as dopamine, serotonin, and adenosine, can be directly measured via electrochemical methods, particularly on carbon-based surfaces. For non-electroactive neurotransmitters like acetylcholine, glutamate, and γ-aminobutyric acid, alternative strategies, such as enzyme immobilization and aptamer-based recognition, are employed to generate electrochemical signals. This review highlights recent developments in flexible MEA fabrication and functionalization to achieve both electrochemical and electrophysiological recordings, minimizing sensor fowling and brain damage when implanted long-term. It covers multi-time scale neurotransmitter detection, development of conducting polymer and nanomaterial composite coatings to enhance sensitivity, incorporation of enzyme and aptamer-based recognition methods, and the integration of carbon electrodes on flexible MEAs. Finally, it summarizes strategies to acquire electrochemical and electrophysiological measurements from the same device.


  • Applicability of an entry flow model of the brachial artery for flow models of the hemodialysis fistula

    by Sulav Bastola, William D Paulson, Steven A Jones

    The native arteriovenous fistula creates a shunt that provides the high blood flow that is needed for dialysis. Lumped parameter hemodynamic models of the arteriovenous fistula can be used to predict shear stresses and pressure losses and can be applied to help understand unsolved problems such as the high rate of arteriovenous fistula maturation failure. These models combine together flow components, such as arteries, stenosis, anastomoses, arterial compliance, and blood inertia, and each component must be modeled with an appropriate pressure–flow relationship. Poiseuille flow is generally assumed for straight vessels, but the unique high flow rates within the brachial artery of an arteriovenous fistula are expected to induce entry flow effects that are neglected in this model. To estimate the importance of these effects, brachial artery flow was modeled in a low-resistance network, such as the one that occurs when an arteriovenous fistula is constructed, through the lumped parameter model, and the predicted flow rates and pressures were compared to those predicted by computational fluid dynamics. When Poiseuille flow was assumed, the flow rate from the lumped parameter model was consistently larger than that from computational fluid dynamics, with a cycle-averaged error of 36.8%. When an entry flow model (Shah) was assumed, the lumped parameter–based flow was 6% lower than the computational fluid dynamics model at the peak of the flow waveform, and the cycle-averaged error was reduced to 7.8%. Thus, in a low-resistance (high flow) arteriovenous fistula circuit, an entry flow model can account for steeper near-wall velocity gradients. This result can provide a useful guide for designing engineering models of the arteriovenous fistula.


  • Mathematical Model for Pressure Losses in the Hemodialysis Graft Vascular Circuit

    by Steven A. Jones, Song Jin, Ameya Kantak, David A. Bell, William D. Paulson

    Stenosis-induced thrombosis and abandonment of the hemodialysis synthetic graft is an important cause of morbidity and mortality. The graft vascular circuit is a unique low-resistance shunt that has not yet been systematically evaluated. In this study, we developed a mathematical model of this circuit. Pressure losses ΔPs were measured in an in vitro experimental apparatus and compared with losses predicted by equations from the engineering literature. We considered the inflow artery, arterial and venous anastomoses, graft, stenosis, and outflow vein. We found significant differences between equations and experimental results, and attributed these differences to the transitional nature of the flow. Adjustment of the equations led to good agreement with experimental data. The resulting mathematical model predicts relations between stenosis, blood flow, intragraft pressure, and important clinical variables such as mean arterial blood pressure and hematocrit. Application of the model should improve understanding of the hemodynamics of the stenotic graft vascular circuit.


  • Coating and Selective Deposition of Nanofilm on Silicone Rubber for Cell Adhesion and Growth

    by Hua Ai, Yuri M. Lvov, David K. Mills, Merilyn Jennings, Jonathan S. Alexander, Steven A. Jones

    A recently developed method for surface modification, layer-by-layer (LbL) assembly, has been applied to silicone, and its ability to encourage endothelial cell growth and control cell growth patterns has been examined. The surfaces studied consisted of a precursor, with alternating cationic polyethyleneimine (PEI) and anionic sodium polystyrene sulfonate (PSS) layers followed by alternating gelatin and poly-d-lysine (PDL) layers. Film growth increased linearly with the number of layers. Each PSS/PEI bilayer was 3 nm thick, and each gelatin/PDL bilayer was 5 nm thick. All layers were more hydrophilic than the unmodified silicone rubber surface, as determined from contact angle measurements. The contact angle was primarily dictated by the outermost layer. Of the coatings studied, gelatin was the most hydrophilic. A film of (PSS/PEI)4/(gelatin/PDL)4/ gelatin was highly favorable for cell adhesion and growth, in contrast to films of (PSS/PEI)8 or (PSS/PEI)8/PSS. Cell growth patterns were successfully controlled by selective deposition of microspheres on silicone rubber, using microcontact printing with a silicone stamp. Cell adhesion was confined to the region of microsphere deposition. These results demonstrate that the LbL self-assembly technique provides a general approach to coat and selectively deposit films with nanometer thickness on silicone rubber. Furthermore, they show that this method is a viable technique for controlling cellular adhesion and growth.


  • Platelet Function Assessment in a Microfabricated Device

    by Ameya Kantak, Yuri Lvov, David K. Mills, James G. Spaulding, Steven A. Jones

    Although platelets are small and simple in shape, they are complicated in their physiologhy. Their alpha granules and dense bodies secrete a large number of agents that are involved in haemostasis, and the glycoproteins on their surfaces form the linkages with proteins like fibrinogen, fibronectin, collagen and von Willebrand factor that are necessary for adhesion and aggregation (Frojmovic, 1998). Diseases such as heart attack (Meade, 1992), stroke (Harker, 1998) and eclampsia (Schindler et al., 1990), can be the result of pathologies in platelets. Although devices have been recently developed to diagnose platelet function (Nicholson et al., 1998), there is still a need for devices that can examine the multiple factors of platelet physiology that affect thrombus formation. Because fluid shear is a key factor in platelet adhesion and aggregation (Colantuoni et al., 1977), it is necessary to test platelet function under conditions of flow. Also, because of the large number of adhesion receptors and secreted agents that make up a platelet’s physiology, a complete diagnosis of platelet function should be performed on a variety of substrates.