GGGary Grove

Gary Grove

*This is an algorithmically generated author record based on publicly available information.

Gary Grove has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An objective comparison of two pulse oximetry sensors with different adhesive systems on healthy human volunteers based on biophysical assessments

    by Gary Grove, Timothy Houser, Jacob Dove, Derek Moody

    Background: Medical Adhesive Related Skin Injuries can arise from topically applied medical devices, especially in those with fragile skin, including the elderly and premature infants. The purpose of this study was to compare gentleness and reapplication of two pulse oximetry sensors (OxySoftN and MaxN, Medtronic, Boulder, CO).Materials and methods: Eighteen healthy subjects aged 65 years and older were enrolled in the gentleness trial, and 20 healthy subjects (18–69 years) were enrolled in the reapplication trial. For the gentleness trial, trans‐epidermal water loss (TEWL) measurements were made at five sites on each forearm at three time points (baseline [T0], 4‐h postinitial wear [T1], 4‐h postsecond wear [T2]). Total amount of protein adhered to each device was also determined. For the reapplication trial, a series of 180° peel tests were performed to observe the forces required to detach the sensor from the skin.Results: TEWL rates in the tail region were significantly greater with MaxN compared to OxySoftN at T1 (p < 0.05). Both were significantly greater than control (p < 0.05). Further, protein analysis revealed that the amount of protein removed was significantly less with OxySoftN compared to MaxN (p < < 0.0001). Differences in loss of adhesion of the tail region between the two sensors were demonstrated, with OxySoftN depreciating at a much slower rate compared with MaxN.Conclusion: The OxySoftN sensor appears to be gentle, even on fragile skin, based on reduced strain on the skin during removal. Further, it demonstrated the ability to withstand several reapplications without functional loss in adhesion.


  • Open Access

    Measuring epidermal effects of ostomy skin barriers

    by Gary Grove, Tim Houser, Gary Sibbald, Ginger Salvadalena

    Background: Ostomy barriers are adhesive devices designed to hold pouching systems to the abdomen and protect the peristomal skin from stoma effluent. The objective of this study was to determine differences in the extent of skin trauma resulting from serially applying and removing two types of ostomy barriers.Methods: The study was a randomized, prospective, repeated measure trial involving healthy volunteers. The ostomy skin barriers were applied to the abdomen and changed every 3‐4 days over a 17‐day period. Skin observations (erythema, stripping, edge irritation and overall comparisons) were completed by a trained (blinded) observer. Transepidermal water loss (TEWL) measurements were completed by a separate (blinded) technician. TEWL was measured in a designated site and again in the most visually traumatized location at termination.Results: Statistically significant differences were found between the two test devices in all assessments but visual observation of erythema. Highly significant differences in TEWL were found between the test products when measured at termination from the most visually traumatized sites.Conclusions: The ostomy barrier with ceramide was significantly less disruptive to the epidermis than the ostomy barrier without ceramide. TEWL measurements were more sensitive to changes in the barrier function of the skin than visual observation of erythema.


  • A Randomized and Controlled Comparison of Gentleness of 2 Medical Adhesive Tapes in Healthy Human Subjects

    by Gary L. Grove, Charles R. Zerweck, Timothy P. Houser, Graham E. Smith, Nancy I. Koski

    To compare gentleness of a silicone tape to a paper tape and to an untreated control. Controlled, randomized, grader-blinded cohort trial. The sample group comprised 28 healthy volunteers aged 55 years and older (median age = 63 years) with a Fitzpatrick Skin Type of I, II, or III. All volunteers were recruited from the greater Philadelphia area and the study was conducted at a dermatological research facility specializing in noninvasive instrumental measurements. Tapes were applied and removed daily (excluding weekends) to 2 of 3 sites on the left and right volar forearms over an 11-day period. The center site on each forearm was left untreated and tapes were randomized to the proximal and distal sites. The primary assessment was transepidermal water loss (TEWL); secondary assessments included erythema/edema, denudation/skin-stripping, and subject self-evaluations. Study personnel conducting the primary and secondary assessments were not involved with treatments to maintain the blinded nature of the study. The identity of the 2 tapes was not revealed to the subjects until after conclusion of the study. On day 11 the mean TEWL value for the paper tape was significantly higher than that for both the untreated control and silicone tape (P < .001). End-of-study mean TEWL values were 2.65 ± 0.68 g/mh for the silicone tape, 6.85 ± 4.97 g/mh for the paper tape, and 3.73 ± 1.19 g/mh for the untreated control. At all assessments, the silicone tape exhibited net changes from baseline that were significantly less than the paper tape (P < .05 day 1, P < .001 days 4, 7, and 11) and similar for the untreated control. Only at days 4 (P < .01) and 11 (P < .001) was the paper tape significantly higher than that for the untreated control. Throughout the study, both tapes exhibited mean TEWL values within the range of normal intact forearm skin, indicating that both tapes were gentle. No differences in erythema/edema scores occurred but the silicone tape resulted in lower denudation/skin-stripping scores than the paper tape at days 4 to 11 (P < .0001). Self-assessment of pain at removal was low for both tapes but significantly lower for the silicone tape (days 1-7, P = .02; day 11, P = .009). Forty-four percent of participants expressed a preference for the silicone tape as compared to the paper tape (19%), with 37% stating no preference. Based on TEWL assessment of disruption of the stratum corneum water barrier, the silicone tape proved gentler to the skin than the paper tape. After 9 applications and removals over 11 days of study, the silicone tape was similar to the untreated control, whereas the paper tape exhibited significantly higher mean TEWL values than both the untreated control and the silicone tape. Expert grader assessments corroborate these findings. These data indicate that the silicone tape may provide additional gentleness when it is clinically needed.


  • Comparison of Two Preoperative Skin Antiseptic Preparations and Resultant Surgical Incise Drape Adhesion to Skin in Healthy Volunteers

    by Gary L. Grove, Chou I. Eyberg

    Background: Adhesion of incise drapes is important at the wound edge, where the skin and drapes are contiguous with the wound. Separation of incise drapes from the skin has been reported to be associated with a sixfold increase in the infection rate compared with surgical procedures in which the drape did not lift off. The present study sought to determine whether the choice of preoperative skin preparation affects the adhesion of various incise drapes. Methods: Following randomization, the backs of twenty-two healthy volunteers were prepared with two skin preparations, 3M DuraPrep Surgical Solution Patient Preoperative Skin Preparation or ChloraPrep with Tint (Scrub Teal) Patient Preoperative Skin Preparation, according to the label directions. Sample strips (12.7 × 76.2 mm) of three different drapes were applied to the prepared areas and were covered with gauze soaked with saline solution for thirty minutes to simulate a fluid challenge. Drape samples were mechanically removed with use of a peel tester based on an international standard for testing peel adhesion of pressure-sensitive tape. Adverse events were monitored and the skin condition was observed. The primary outcome was drape adhesion, measured as the peel strength in units of gram-force. Outcomes were assessed according to drape type and skin preparation with use of mixed-model analysis of variance. Results: Skin prepared with DuraPrep solution had significantly greater drape adhesion (mean peel strength, 181 gf) compared with skin prepared with ChloraPrep (79 gf, p < 0.001). Although maintaining good adhesion is important, an incise drape that has excessive adhesion may cause skin irritation. Regardless of the skin preparation used, the skin reaction at the application site ranged from none to moderate erythema, and in no instance constituted an adverse event that required treatment. Conclusions: The data suggest that the type of skin preparation affects drape adhesion. For surgical procedures in which incise drapes are used, choosing a skin preparation that enhances drape adhesion may minimize drape lifting and the potential for wound contamination. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.


    • 1 February 2004
      • Vol. 73  (2) , 135-9

    An evaluation of the moisturizing and anti-itch effects of a lactic acid and pramoxine hydrochloride cream.

    by Gary Grove, Charles Zerweck

    An open-label, single-center, observer-blinded, controlled trial was conducted during the winter months to evaluate the moisturizing and antipruritic effects of a unique formulation of lactic acid 12% neutralized with ammonium hydroxide and pramoxine hydrochloride (HCl) 1% in 24 women with a history of dry itchy skin. Baseline assessments for appearance of dryness of both lower legs of each patient were conducted by a blinded expert grader; skin surface hydration was measured by the IBS Co, Ltd, Skicon-200 (Hamamatsu, Japan) conductivity meter; and dryness and itch were measured through self-assessment surveys. The women stopped the use of all moisturizing agents 7 days prior to and throughout the study and were allowed to use only a nonmoisturizing soap for bathing and shaving. Patients were randomized as to which leg to apply the test cream; the opposite leg was used as a nontreated control. Patients applied the test product liberally to the assigned leg twice daily for 7 days and had repeat assessments for appearance and hydration on the morning of days 3 and 7; self-assessments of itch and dryness were completed on days 1, 2, 3, 6, and 7. Expert grader assessment of skin dryness showed significant improvement with the test cream compared with no treatment on day 3 (P=.0004) and on day 7 (P<.001). Patients had statistically significant improvement in skin surface hydration by day 3 (P<.0001), with further improvement by day 7 (P<.0001). Patients also reported significant improvements in skin dryness and itch by day 1 (P<.0001 and (P<.0001, respectively), which continued to improve through day 7 (P<.0001 and P<.0001, respectively). In conclusion, the test cream was shown to be an effective moisturizer and antipruritic agent in treating dry itchy skin.