Andrea Perdicchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrea Perdicchi has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
E.M. Medori
Department of Ophthalmology, Sant'Andrea Hospital, La Sapienza II University, Roma
2 shared publications- Gianluca Scuderi
Ophthalmology Unit, Neurosciences, Mental Health, and Sensory Organs (NESMOS) Department, Sapienza University of Rome, Rome, Italy
2 shared publications - Michele Iester
University of Genoa
2 shared publications S.M. Recupero
Department of Ophthalmology, Sant'Andrea Hospital, La Sapienza II University, Roma
2 shared publicationsSanti Maria Recupero
Ophthalmology Unit, St. Andrea Hospital, NESMOS Department, University of Rome “Sapienza”, Via di Grottarossa 1035-1039, 00189 Rome, Italy
2 shared publicationsStefano Amodeo
2 shared publications
Latest Publications
- Open Access
- 16 September 2015
- Published by Wiley in BioMed Research International
- Vol. 2015, 1-11
Rare Diseases Leading to Childhood Glaucoma: Epidemiology, Pathophysiogenesis, and Management
Noteworthy heterogeneity exists in the rare diseases associated with childhood glaucoma. Primary congenital glaucoma is mostly sporadic; however, 10% to 40% of cases are familial. CYP1B1 gene mutations seem to account for 87% of familial cases and 27% of sporadic cases. Childhood glaucoma is classified in primary and secondary congenital glaucoma, further divided as glaucoma arising in dysgenesis associated with neural crest anomalies, phakomatoses, metabolic disorders, mitotic diseases, congenital disorders, and acquired conditions. Neural crest alterations lead to the wide spectrum of iridocorneal trabeculodysgenesis. Systemic diseases associated with childhood glaucoma include the heterogenous group of phakomatoses where glaucoma is frequently encountered in the Sturge-Weber syndrome and its variants, in phakomatosis pigmentovascularis associated with oculodermal melanocytosis, and more rarely in neurofibromatosis type 1. Childhood glaucoma is also described in systemic disorders of mitotic and metabolic activity. Acquired secondary glaucoma has been associated with uveitis, trauma, drugs, and neoplastic diseases. A database research revealed reports of childhood glaucoma in rare diseases, which do not include glaucoma in their manifestation. These are otopalatodigital syndrome, complete androgen insensitivity, pseudotrisomy 13, Brachmann-de Lange syndrome, acrofrontofacionasal dysostosis, caudal regression syndrome, and Wolf-Hirschhorn syndrome.
- 16 September 2015
- Published by Wiley in BioMed Research International
- Vol. 2015, 1-11
Open AccessRare Diseases Leading to Childhood Glaucoma: Epidemiology, Pathophysiogenesis, and Management
Noteworthy heterogeneity exists in the rare diseases associated with childhood glaucoma. Primary congenital glaucoma is mostly sporadic; however, 10% to 40% of cases are familial. CYP1B1 gene mutations seem to account for 87% of familial cases and 27% of sporadic cases. Childhood glaucoma is classified in primary and secondary congenital glaucoma, further divided as glaucoma arising in dysgenesis associated with neural crest anomalies, phakomatoses, metabolic disorders, mitotic diseases, congenital disorders, and acquired conditions. Neural crest alterations lead to the wide spectrum of iridocorneal trabeculodysgenesis. Systemic diseases associated with childhood glaucoma include the heterogenous group of phakomatoses where glaucoma is frequently encountered in the Sturge-Weber syndrome and its variants, in phakomatosis pigmentovascularis associated with oculodermal melanocytosis, and more rarely in neurofibromatosis type 1. Childhood glaucoma is also described in systemic disorders of mitotic and metabolic activity. Acquired secondary glaucoma has been associated with uveitis, trauma, drugs, and neoplastic diseases. A database research revealed reports of childhood glaucoma in rare diseases, which do not include glaucoma in their manifestation. These are otopalatodigital syndrome, complete androgen insensitivity, pseudotrisomy 13, Brachmann-de Lange syndrome, acrofrontofacionasal dysostosis, caudal regression syndrome, and Wolf-Hirschhorn syndrome.
- 1 January 2013
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 22 (5) , 413-415
Effect of Refractive Correction on the Accuracy of Frequency-doubling Technology Matrix
To investigate the effect of refractive correction on the reliability and accuracy of frequency-doubling technology (FDT) Matrix examinations. Forty-eight eyes of healthy people were submitted to the FDT Matrix 30/2 threshold program. They had experience in perimetry, normal eye examination, and negative history for glaucoma and/or neurological diseases. The subjects were randomized into groups A (24 subjects) and B (24 subjects). The FDT Matrix 30/2 examinations were carried out in 3 different sessions. At the first session, groups A and B underwent the examinations with their best refractive correction. In the second session, group A underwent the FDT 30/2 examination with best refractive correction and the group B without it. In the third session, the groups were matched and followed the same protocol. The perimetric and reliability indexes and the time of examination with or without correction were considered. The Student t test was used when the distribution of the data was normal, whereas Mann-Whitney when the distribution of the data was not normal. After a Bonferroni correction, a P value <0.001 was considered as statistically significant. Mean deviation reduced statistically significantly when refractive correction was used (-2.65±3.71 vs. -1.41±3.51 dB; P<0.006). All the other perimetric indexes and data considered did not change significantly when the subjects did the examination with or without the refractive correction. The statistically significant reduction of mean deviation obtained with corrective lens showed that a better general accuracy and reliability of FDT responses was obtained with refractive correction. Pattern standard deviation constancy with or without correction confirmed that a localized defect is the first sign of visual field defect and that the absence of differences of pattern standard deviation between the 2 sessions is related to the absence of pathologic conditions in the eyes studied. Finally, as FDT Matrix is less influenced by other nonconventional perimetric techniques by refractive errors, the use of corrective lens is advisable to improve the accuracy and reliability of the results obtained and to optimize their performance.
- 1 January 2013
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 22 (5) , 413-415
Effect of Refractive Correction on the Accuracy of Frequency-doubling Technology Matrix
To investigate the effect of refractive correction on the reliability and accuracy of frequency-doubling technology (FDT) Matrix examinations. Forty-eight eyes of healthy people were submitted to the FDT Matrix 30/2 threshold program. They had experience in perimetry, normal eye examination, and negative history for glaucoma and/or neurological diseases. The subjects were randomized into groups A (24 subjects) and B (24 subjects). The FDT Matrix 30/2 examinations were carried out in 3 different sessions. At the first session, groups A and B underwent the examinations with their best refractive correction. In the second session, group A underwent the FDT 30/2 examination with best refractive correction and the group B without it. In the third session, the groups were matched and followed the same protocol. The perimetric and reliability indexes and the time of examination with or without correction were considered. The Student t test was used when the distribution of the data was normal, whereas Mann-Whitney when the distribution of the data was not normal. After a Bonferroni correction, a P value <0.001 was considered as statistically significant. Mean deviation reduced statistically significantly when refractive correction was used (-2.65±3.71 vs. -1.41±3.51 dB; P<0.006). All the other perimetric indexes and data considered did not change significantly when the subjects did the examination with or without the refractive correction. The statistically significant reduction of mean deviation obtained with corrective lens showed that a better general accuracy and reliability of FDT responses was obtained with refractive correction. Pattern standard deviation constancy with or without correction confirmed that a localized defect is the first sign of visual field defect and that the absence of differences of pattern standard deviation between the 2 sessions is related to the absence of pathologic conditions in the eyes studied. Finally, as FDT Matrix is less influenced by other nonconventional perimetric techniques by refractive errors, the use of corrective lens is advisable to improve the accuracy and reliability of the results obtained and to optimize their performance.
- Open Access
- 4 October 2012
- Published by Springer Nature in BMC Research Notes
- Vol. 5 (1) , 549
Evaluation of recurrent hyphema after trabeculectomy with ultrabiomicroscopy 50-80 MHz: a case report
Background: Hyphema is a complication that can occur after glaucoma filtering surgery. Biomicroscopic examination of the anterior segment is commonly used to diagnose it and gonioscopy may provide a useful support to find the source of the haemorrhage. Unfortunately, when the blood hides the structure of the anterior segment the gonioscopic examination fails. In this case we performed ultrabiomiscroscopy with 50–80 MHz probes to overcome the limits of gonioscopy. The use of this technique to study the anterior segment of the eye has previously been reported in literature, but we illustrates its importance for performing a correct diagnosis in a specific case of hyphema. Case presentation: We report a case of a sixty-year-old caucasian male with recurrent hyphema in the left eye. The episodes of hyphema were four in two years and the patient came to the hospital for the first time in the last occasion. The past episodes were managed with topical corticosteroids and mydriatic drops. He referred surgical trabeculectomy in both eyes 5 years before the first symptoms and no specific eye trauma before the first episode. The examination of the anterior segment revealed a 2 mm hyphema in the left eye due to blood leakage through the superior iridectomy. Gonioscopy could not identify the source of the haemorrhage. B-scan ultrasound and ultrabiomiscroscopy, with 50–80 MHz probes, were performed. Ultrabiomiscroscopy, mainly with the probe of 80 MHz, provided images of high resolution of the structures of the anterior segment and it allowed the visualization of an abnormal vessel at the inner margin of the trabeculectomy opening, probably responsible of the recurrent hyphema. Conclusion: Ultrabiomicroscopy proved to be a useful diagnostic technique for identifying the cause of the recurrent hyphema when other examination techniques are not applicable.
- 4 October 2012
- Published by Springer Nature in BMC Research Notes
- Vol. 5 (1) , 549
Open AccessEvaluation of recurrent hyphema after trabeculectomy with ultrabiomicroscopy 50-80 MHz: a case report
Background: Hyphema is a complication that can occur after glaucoma filtering surgery. Biomicroscopic examination of the anterior segment is commonly used to diagnose it and gonioscopy may provide a useful support to find the source of the haemorrhage. Unfortunately, when the blood hides the structure of the anterior segment the gonioscopic examination fails. In this case we performed ultrabiomiscroscopy with 50–80 MHz probes to overcome the limits of gonioscopy. The use of this technique to study the anterior segment of the eye has previously been reported in literature, but we illustrates its importance for performing a correct diagnosis in a specific case of hyphema. Case presentation: We report a case of a sixty-year-old caucasian male with recurrent hyphema in the left eye. The episodes of hyphema were four in two years and the patient came to the hospital for the first time in the last occasion. The past episodes were managed with topical corticosteroids and mydriatic drops. He referred surgical trabeculectomy in both eyes 5 years before the first symptoms and no specific eye trauma before the first episode. The examination of the anterior segment revealed a 2 mm hyphema in the left eye due to blood leakage through the superior iridectomy. Gonioscopy could not identify the source of the haemorrhage. B-scan ultrasound and ultrabiomiscroscopy, with 50–80 MHz probes, were performed. Ultrabiomiscroscopy, mainly with the probe of 80 MHz, provided images of high resolution of the structures of the anterior segment and it allowed the visualization of an abnormal vessel at the inner margin of the trabeculectomy opening, probably responsible of the recurrent hyphema. Conclusion: Ultrabiomicroscopy proved to be a useful diagnostic technique for identifying the cause of the recurrent hyphema when other examination techniques are not applicable.
- Open Access
- 1 March 2009
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 19 (2) , 327
Author Reply
- 1 March 2009
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 19 (2) , 327
Open AccessAuthor Reply
- 1 July 2007
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 17 (4) , 534-537
Visual Field Damage and Progression in Glaucomatous Myopic Eyes
Purpose: To make a visual field retrospective analysis on a group of patients with primary open angle glaucoma (POAG) and to evaluate whether different refractive errors could have different progression of the 30° central sensitivity. Methods: A total of 110 patients with POAG (52 men and 58 women) were included in the study. All the patients were divided into four subgroups based on the refractive error. The visual field of all the included patients was assessed by an Octopus 30° central visual field every 6 months, for a total of 837 visual fields examined. The resulting data were analyzed by PERIDATA for Windows 1.7 TREND function. Mean defect (MD) and loss variance (LV) were considered for the analysis. Results: At the first examination, 82% of eyes showed a global decrease of differential light sensitivity (MD >2 dB) and in 67% the distribution of the defect was nonhomogeneous (LV >6 dB). The analysis of variance for subgroups showed a more significant decrease of MD in highly myopic patients. A linear regression analysis highlighted a statistically significant change in time of MD in 36% and of LV in 34% of the eyes studied. Highly myopic patients had the highest (p<0.01) percentage of change of MD and LV (46% and 42%, respectively). Among the four subgroups, there was no difference in progression of MD decrease in time. Conclusions: These results showed that after 5 years of glaucoma, the visual field was altered in most of the eyes examined (82%) and that in 67% of cases, its defect was nonhomogeneous and worsened with the increase of myopia. The regression linear analysis of visual field changes in time showed a progressive increase of MD and LV in approximately one third of all the eyes examined.
- 1 July 2007
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 17 (4) , 534-537
Visual Field Damage and Progression in Glaucomatous Myopic Eyes
Purpose: To make a visual field retrospective analysis on a group of patients with primary open angle glaucoma (POAG) and to evaluate whether different refractive errors could have different progression of the 30° central sensitivity. Methods: A total of 110 patients with POAG (52 men and 58 women) were included in the study. All the patients were divided into four subgroups based on the refractive error. The visual field of all the included patients was assessed by an Octopus 30° central visual field every 6 months, for a total of 837 visual fields examined. The resulting data were analyzed by PERIDATA for Windows 1.7 TREND function. Mean defect (MD) and loss variance (LV) were considered for the analysis. Results: At the first examination, 82% of eyes showed a global decrease of differential light sensitivity (MD >2 dB) and in 67% the distribution of the defect was nonhomogeneous (LV >6 dB). The analysis of variance for subgroups showed a more significant decrease of MD in highly myopic patients. A linear regression analysis highlighted a statistically significant change in time of MD in 36% and of LV in 34% of the eyes studied. Highly myopic patients had the highest (p<0.01) percentage of change of MD and LV (46% and 42%, respectively). Among the four subgroups, there was no difference in progression of MD decrease in time. Conclusions: These results showed that after 5 years of glaucoma, the visual field was altered in most of the eyes examined (82%) and that in 67% of cases, its defect was nonhomogeneous and worsened with the increase of myopia. The regression linear analysis of visual field changes in time showed a progressive increase of MD and LV in approximately one third of all the eyes examined.
- 1 May 2007
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 16 (3) , 297-301
The Influence of Learning Effect on Frequency Doubling Technology Perimetry (Matrix)
Purpose To determine learning effect in healthy patients without perimetric experience, tested with the frequency doubling technology perimetry, with the new model Matrix. Patients and Methods Frequency doubling technology in the 30-2 threshold mode was performed on 37 healthy subjects. Each subject was tested twice in different sessions. The test always began with the right eye (RE) and continued with the left eye (LE). To evaluate learning effect the results of the REs at the first session were compared with those of the LE. The following parameters were evaluated: foveal threshold (FT), reliability indexes, mean defect (MD), pattern standard deviation (PSD), glaucoma hemifield test (GHT), duration of examination. Results At the first session the average values of RE were FT=30.81 db, MD=−1 db, PSD=3.01 db, and duration of the examination=383.27 “and of LE were FT=30.73, MD=−0.79 db, PSD=2.97 db, and duration of examination 382.62.” At the second session the average values of RE were FT=32.22 db, MD=+0.16 db, PSD 2.75 db, and duration of examination=374.97 db. The reliability was different and the GHT between the RE and LE in the first and second session was also different. Conclusions A learning effect was observed between the first and the second sessions and the results of the GHT appeared improved. This above all should be taken into account when considering the clinical use of this test to avoid erroneous diagnostic conclusions.
- 1 May 2007
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 16 (3) , 297-301
The Influence of Learning Effect on Frequency Doubling Technology Perimetry (Matrix)
Purpose To determine learning effect in healthy patients without perimetric experience, tested with the frequency doubling technology perimetry, with the new model Matrix. Patients and Methods Frequency doubling technology in the 30-2 threshold mode was performed on 37 healthy subjects. Each subject was tested twice in different sessions. The test always began with the right eye (RE) and continued with the left eye (LE). To evaluate learning effect the results of the REs at the first session were compared with those of the LE. The following parameters were evaluated: foveal threshold (FT), reliability indexes, mean defect (MD), pattern standard deviation (PSD), glaucoma hemifield test (GHT), duration of examination. Results At the first session the average values of RE were FT=30.81 db, MD=−1 db, PSD=3.01 db, and duration of the examination=383.27 “and of LE were FT=30.73, MD=−0.79 db, PSD=2.97 db, and duration of examination 382.62.” At the second session the average values of RE were FT=32.22 db, MD=+0.16 db, PSD 2.75 db, and duration of examination=374.97 db. The reliability was different and the GHT between the RE and LE in the first and second session was also different. Conclusions A learning effect was observed between the first and the second sessions and the results of the GHT appeared improved. This above all should be taken into account when considering the clinical use of this test to avoid erroneous diagnostic conclusions.
- 1 March 2007
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 17 (2) , 259-261
Ultrabiomicroscopy (Ubm) in Flap Dislocation following Lasik: A Case Report
Purpose: To describe postoperative laser-assisted in situ keratomileusis (LASIK) flap dislocation occurred after trauma Methods: Ultrabiomicroscopy (UBM) is used to obtain a high-resolution imaging of the cornea. Results: The UBM results are presented and compared with histologic and confoscan findings. Conclusions: The technique is useful and easy to perform, offering more opportunities to study the anatomical changes in LASK flap dislocation occurred after trauma. (Eur J Ophthalmol 2007; 17: 259–61)
- 1 March 2007
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 17 (2) , 259-261
Ultrabiomicroscopy (Ubm) in Flap Dislocation following Lasik: A Case Report
Purpose: To describe postoperative laser-assisted in situ keratomileusis (LASIK) flap dislocation occurred after trauma Methods: Ultrabiomicroscopy (UBM) is used to obtain a high-resolution imaging of the cornea. Results: The UBM results are presented and compared with histologic and confoscan findings. Conclusions: The technique is useful and easy to perform, offering more opportunities to study the anatomical changes in LASK flap dislocation occurred after trauma. (Eur J Ophthalmol 2007; 17: 259–61)
- 1 January 2006
- Published by Springer Nature in Annals of Ophthalmology
- Vol. 38 (2) , 107-110
Visual Acuity in Central and Branch Vein Retinal Occlusion in the Presence of Macular Edema: 1 Year of Follow-Up
- 1 January 2006
- Published by Springer Nature in Annals of Ophthalmology
- Vol. 38 (2) , 107-110
Visual Acuity in Central and Branch Vein Retinal Occlusion in the Presence of Macular Edema: 1 Year of Follow-Up