Satoshi Oki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Satoshi Oki has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Noboru Matsumura
Department of Orthopaedic Surgery, Keio University School of Medicine, Tokyo, Japan
12 shared publications Takeo Nagura
Department of Orthopedic Surgery, Keio University School of Medicine, Tokyo, Japan
8 shared publications- Ryogo Furuhata
Department of Orthopaedic Surgery, Ashikaga Red Cross Hospital, Ashikaga-shi, Tochigi, Japan
6 shared publications - Takeo Nagura
Department of Clinical Biomechanics, Keio University School of Medicine, Tokyo, Japan
6 shared publications Masahiro Jinzaki
Department of Diagnostic Radiology, Keio University School of Medicine, Tokyo, Japan
5 shared publications- Masaya Nakamura
Department of Orthopaedic Surgery Keio University School of Medicine Tokyo Japan
5 shared publications
Latest Publications
- Open Access
- 5 February 2026
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 138  (3) , 305-309
Plate fixation combined with suture bridge technique for proximal humeral fracture-dislocation with displaced greater tuberosity: a case series
Introduction: Plate fixation is an established procedure for proximal humeral fractures involving the greater tuberosity; however, concomitant glenohumeral dislocation increases the risk of secondary displacement of the greater tuberosity fragments. The suture bridge technique has produced satisfactory outcomes for greater tuberosity fractures; however, little is known about the outcomes of combining plate fixation with the suture bridge technique. We report the surgical technique and outcomes of plate fixation combined with the suture bridge technique for proximal humeral fracture-dislocations with displaced greater tuberosity. Highlights Presentation of case: We retrospectively identified six patients who underwent plate fixation combined with a suture bridge technique. Using the deltopectoral approach, we reduced the fractured fragments. We inserted medial anchors into the proximal margin of the humeral fracture surface and distal anchors into the shaft, and fixed the greater tuberosity fragments using the suture bridge technique. The fractured fragments were fixed using a locking plate. We evaluated postoperative shoulder functional scores and complications. The mean Constant score was 86, and the American Shoulder and Elbow Surgeons score was 85 at 1 year postoperatively. No major postoperative complications were observed. Discussion: The procedure yielded satisfactory functional and radiological outcomes. Plate fixation combined with the suture bridge technique allows for more secure fixation of greater tuberosity fragments than conventional procedures, potentially preventing greater tuberosity displacement postoperatively. Conclusion: This case series presents a new fixation procedure for proximal humeral fractures, which can be advantageous in patients with a high risk of postoperative greater tuberosity displacement.
- 5 February 2026
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 138  (3) , 305-309
Open AccessPlate fixation combined with suture bridge technique for proximal humeral fracture-dislocation with displaced greater tuberosity: a case series
Introduction: Plate fixation is an established procedure for proximal humeral fractures involving the greater tuberosity; however, concomitant glenohumeral dislocation increases the risk of secondary displacement of the greater tuberosity fragments. The suture bridge technique has produced satisfactory outcomes for greater tuberosity fractures; however, little is known about the outcomes of combining plate fixation with the suture bridge technique. We report the surgical technique and outcomes of plate fixation combined with the suture bridge technique for proximal humeral fracture-dislocations with displaced greater tuberosity. Highlights Presentation of case: We retrospectively identified six patients who underwent plate fixation combined with a suture bridge technique. Using the deltopectoral approach, we reduced the fractured fragments. We inserted medial anchors into the proximal margin of the humeral fracture surface and distal anchors into the shaft, and fixed the greater tuberosity fragments using the suture bridge technique. The fractured fragments were fixed using a locking plate. We evaluated postoperative shoulder functional scores and complications. The mean Constant score was 86, and the American Shoulder and Elbow Surgeons score was 85 at 1 year postoperatively. No major postoperative complications were observed. Discussion: The procedure yielded satisfactory functional and radiological outcomes. Plate fixation combined with the suture bridge technique allows for more secure fixation of greater tuberosity fragments than conventional procedures, potentially preventing greater tuberosity displacement postoperatively. Conclusion: This case series presents a new fixation procedure for proximal humeral fractures, which can be advantageous in patients with a high risk of postoperative greater tuberosity displacement.
- Open Access
- 8 July 2025
- Published by Elsevier in JSES International
- Vol. 9  (6) , 1922-1928
Anatomical ligament reconstruction for Neer type IIB distal clavicular fractures using suture buttons without acromioclavicular joint fixation
- 8 July 2025
- Published by Elsevier in JSES International
- Vol. 9  (6) , 1922-1928
Open AccessAnatomical ligament reconstruction for Neer type IIB distal clavicular fractures using suture buttons without acromioclavicular joint fixation
- Open Access
- 22 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13  (23) , 7043
Prospective Study on Splinting for First Carpometacarpal Joint: A Comparison of Conventional and Three-Dimensional Printed Splint
Background: Patient compliance is a major concern of hand orthosis in first carpometacarpal osteoarthritis. To address this issue, we established a method for creating a custom-made three-dimensional printed splint based on computed tomography. This prospective study evaluates the usefulness of the three-dimensional printed splint compared with the conventional splint. Methods: A total of 12 hands in nine patients were included. The mean age of the patients was 69 years (range: 58â84). Conventional orthoses were made by prosthetists using molds. Three-dimensional printed orthoses (long and short types) were digitally designed from computed tomography data and created using Fused Deposition Modeling. Subjects were instructed to use three types of orthoses for 2 weeks each. They completed questionnaires that indicated pain, function, percentage of daytime spent using the orthosis, satisfaction score, and discomfort caused by wearing orthoses. Results: The pain on motion showed an improvement of approximately 20% for all orthoses. There was no significant difference in pain scale, function, percentages of daytime spent using each orthosis, and satisfaction score among the three types of orthoses. Discomfort caused by wearing orthosis was more frequent in conventional orthosis than in 3D-printed orthosis, and there was a significant difference between the conventional type and the long-type 3D-printed orthosis. Conclusions: This study suggests that 3D-printed splints provide comparable pain relief to conventional splints with reduced discomfort. However, limitations such as small sample size, short follow-up, and reliance on CT imaging highlight the need for further research.
- 22 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13  (23) , 7043
Open AccessProspective Study on Splinting for First Carpometacarpal Joint: A Comparison of Conventional and Three-Dimensional Printed Splint
Background: Patient compliance is a major concern of hand orthosis in first carpometacarpal osteoarthritis. To address this issue, we established a method for creating a custom-made three-dimensional printed splint based on computed tomography. This prospective study evaluates the usefulness of the three-dimensional printed splint compared with the conventional splint. Methods: A total of 12 hands in nine patients were included. The mean age of the patients was 69 years (range: 58â84). Conventional orthoses were made by prosthetists using molds. Three-dimensional printed orthoses (long and short types) were digitally designed from computed tomography data and created using Fused Deposition Modeling. Subjects were instructed to use three types of orthoses for 2 weeks each. They completed questionnaires that indicated pain, function, percentage of daytime spent using the orthosis, satisfaction score, and discomfort caused by wearing orthoses. Results: The pain on motion showed an improvement of approximately 20% for all orthoses. There was no significant difference in pain scale, function, percentages of daytime spent using each orthosis, and satisfaction score among the three types of orthoses. Discomfort caused by wearing orthosis was more frequent in conventional orthosis than in 3D-printed orthosis, and there was a significant difference between the conventional type and the long-type 3D-printed orthosis. Conclusions: This study suggests that 3D-printed splints provide comparable pain relief to conventional splints with reduced discomfort. However, limitations such as small sample size, short follow-up, and reliance on CT imaging highlight the need for further research.
- 12 June 2023
- Published by Springer Nature in Skeletal Radiology
- Vol. 53  (1) , 129-140
In-vivo kinematics of the trapeziometacarpal joint in dynamic pinch motion using four-dimensional computed tomography imaging
Objective CT imaging precisely and quantitatively analyzes the kinematics of the carpal bones to evaluate the etiology of related osteoarthritis. Previous studies have investigated the kinematics of the trapeziometacarpal joint using static CT scans of various postures including the pinch position. This study analyzed the in-vivo kinematics of the trapeziometacarpal joint during dynamic pinch motion in young healthy volunteers using four-dimensional CT. Materials and methods Twelve healthy young volunteers participated in this study. Each participant held the pinch meter between their thumb and index finger and pinched it with maximum force for a period of 6 s. This series of movement was recorded using a four-dimensional CT. The surface data of the trapezium and first metacarpal of all frames were reconstructed, and bone movement at the trapeziometacarpal joint was calculated using sequential three-dimensional registration. The instantaneous pinch force of each frame was measured using a pointer on a pinch meter that was reconstructed from the CT data. Results The first metacarpal was abducted (15.9 ¹ 8.3°) and flexed (12.2 ¹ 7.1°) relative to the trapezium, and significantly translated to the volar (0.8 ¹ 0.6 mm) and ulnar directions (0.9 ¹ 0.8 mm) with maximum pinch force. This movement consistently increased with the pinch force. Conclusion This study successfully employed 4D-CT to precisely demonstrate changes in rotation and translation at the trapeziometacarpal joint during pinch motion for various instantaneous forces.
- 12 June 2023
- Published by Springer Nature in Skeletal Radiology
- Vol. 53  (1) , 129-140
In-vivo kinematics of the trapeziometacarpal joint in dynamic pinch motion using four-dimensional computed tomography imaging
Objective CT imaging precisely and quantitatively analyzes the kinematics of the carpal bones to evaluate the etiology of related osteoarthritis. Previous studies have investigated the kinematics of the trapeziometacarpal joint using static CT scans of various postures including the pinch position. This study analyzed the in-vivo kinematics of the trapeziometacarpal joint during dynamic pinch motion in young healthy volunteers using four-dimensional CT. Materials and methods Twelve healthy young volunteers participated in this study. Each participant held the pinch meter between their thumb and index finger and pinched it with maximum force for a period of 6 s. This series of movement was recorded using a four-dimensional CT. The surface data of the trapezium and first metacarpal of all frames were reconstructed, and bone movement at the trapeziometacarpal joint was calculated using sequential three-dimensional registration. The instantaneous pinch force of each frame was measured using a pointer on a pinch meter that was reconstructed from the CT data. Results The first metacarpal was abducted (15.9 ¹ 8.3°) and flexed (12.2 ¹ 7.1°) relative to the trapezium, and significantly translated to the volar (0.8 ¹ 0.6 mm) and ulnar directions (0.9 ¹ 0.8 mm) with maximum pinch force. This movement consistently increased with the pinch force. Conclusion This study successfully employed 4D-CT to precisely demonstrate changes in rotation and translation at the trapeziometacarpal joint during pinch motion for various instantaneous forces.
- Open Access
- 3 November 2022
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 17  (1) , 1-7
Inferior subluxation of humeral head after osteosynthesis for greater tuberosity fracture
Background: Inferior subluxation of the humeral head is frequently observed immediately after surgery for proximal humerus fractures; however, the incidence and risk factors of inferior subluxation after osteosynthesis for isolated greater tuberosity fractures remain unsolved. Additionally, the postoperative course of inferior subluxation has not been elucidated. The purpose of the present study is to identify the predictors for the occurrence of postoperative inferior subluxation by multivariate analysis and investigate the postoperative shift of inferior subluxation and its effect on surgical outcomes. Methods: We retrospectively identified 68 patients who underwent surgery for isolated greater tuberosity fractures. The dependent variable was the inferior subluxation at 1 week postoperatively. The explanatory variables were age, sex, affected side of the shoulder, body mass index, history of smoking, local osteoporosis, time period to surgery, axillary nerve injury, inferior subluxation before surgery, fracture dislocation, surgical approach, surgical method, operative time, amount of blood loss, and postoperative drainage. Baseline variables that were statistically significant in the univariate analyses were included in the logistic regression analysis. The patients were further categorized into two groups according to the presence of inferior shoulder subluxation exhibited 1 week postoperatively: patients with inferior subluxation (+ IS group) and patients without inferior subluxation (â IS group). We compared the incidence of postoperative complications between the two groups. Results: Of 68 patients, 17 (25.0%) had inferior shoulder subluxation observed 1 week postoperatively. Multivariate analysis showed that long operative time was a risk factor for postoperative subluxation (odds ratio = 1.03; P = 0.030). In all cases, inferior subluxation disappeared within 3 months of surgery. No significant difference in complication rate was observed between the + IS and â IS groups. Conclusions: The present study provides novel information regarding postoperative inferior subluxation of fractures of the greater tuberosity. Inferior subluxation occurred in 25% of patients immediately after surgery. Long operative time contributes to the onset of postoperative inferior subluxation; however, this was temporary in all cases and had no significant effect on the surgical outcomes. Level of Evidence: Level III.
- 3 November 2022
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 17  (1) , 1-7
Open AccessInferior subluxation of humeral head after osteosynthesis for greater tuberosity fracture
Background: Inferior subluxation of the humeral head is frequently observed immediately after surgery for proximal humerus fractures; however, the incidence and risk factors of inferior subluxation after osteosynthesis for isolated greater tuberosity fractures remain unsolved. Additionally, the postoperative course of inferior subluxation has not been elucidated. The purpose of the present study is to identify the predictors for the occurrence of postoperative inferior subluxation by multivariate analysis and investigate the postoperative shift of inferior subluxation and its effect on surgical outcomes. Methods: We retrospectively identified 68 patients who underwent surgery for isolated greater tuberosity fractures. The dependent variable was the inferior subluxation at 1 week postoperatively. The explanatory variables were age, sex, affected side of the shoulder, body mass index, history of smoking, local osteoporosis, time period to surgery, axillary nerve injury, inferior subluxation before surgery, fracture dislocation, surgical approach, surgical method, operative time, amount of blood loss, and postoperative drainage. Baseline variables that were statistically significant in the univariate analyses were included in the logistic regression analysis. The patients were further categorized into two groups according to the presence of inferior shoulder subluxation exhibited 1 week postoperatively: patients with inferior subluxation (+ IS group) and patients without inferior subluxation (â IS group). We compared the incidence of postoperative complications between the two groups. Results: Of 68 patients, 17 (25.0%) had inferior shoulder subluxation observed 1 week postoperatively. Multivariate analysis showed that long operative time was a risk factor for postoperative subluxation (odds ratio = 1.03; P = 0.030). In all cases, inferior subluxation disappeared within 3 months of surgery. No significant difference in complication rate was observed between the + IS and â IS groups. Conclusions: The present study provides novel information regarding postoperative inferior subluxation of fractures of the greater tuberosity. Inferior subluxation occurred in 25% of patients immediately after surgery. Long operative time contributes to the onset of postoperative inferior subluxation; however, this was temporary in all cases and had no significant effect on the surgical outcomes. Level of Evidence: Level III.
- Open Access
- 15 April 2022
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 17  (1) , 1-9
Three-dimensional alignment of the upper extremity in the standing neutral position in healthy subjects
Background: Though alignment of the spine and lower extremities in the standing neutral position has been evaluated, a few studies evaluating the alignment of the upper extremities have also been made. This study assessed the normal alignment of the upper extremities in the standing neutral position and clarified the three-dimensional angular rotations of the upper extremity joints. Methods: Computed tomography (CT) images of 158 upper extremities from 79 healthy volunteers were prospectively acquired in the standing neutral position using an upright CT scanner. Three-dimensional coordinate systems of the thorax, scapula, humerus, and forearm were designated, and three-dimensional angular rotations of the scapulothoracic, glenohumeral, and elbow joints were calculated. Results: The median angle of the scapulothoracic joint was 9.2° (interquartile range [IQR], 5.2°â12.5°) of upward rotation, 29.0° (IQR, 24.9°â33.3°) of internal rotation, and 7.9° (IQR, 4.3°â11.8°) of anterior tilt. The median angle of the glenohumeral joint was 4.5° (IQR, 0.9°â7.8°) of abduction, 9.0° (IQR, 2.2°â19.0°) of internal rotation, and 0.3° (IQR, â 2.6°â3.1°) of extension. The median angle of the elbow joint was 9.8° (IQR, 6.9°â12.4°) of valgus, 90.2° (IQR, 79.6°â99.4°) of pronation, and 15.5° (IQR, 13.2°â18.1°) of flexion. Correlations in angular rotation values were found between the right and left upper extremities and between joints. Conclusions: This study clarified the three-dimensional angular rotation of upper extremity joints in the standing neutral position using an upright CT scanner. Our results may provide important insights for the functional evaluation of upper extremity alignment.
- 15 April 2022
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 17  (1) , 1-9
Open AccessThree-dimensional alignment of the upper extremity in the standing neutral position in healthy subjects
Background: Though alignment of the spine and lower extremities in the standing neutral position has been evaluated, a few studies evaluating the alignment of the upper extremities have also been made. This study assessed the normal alignment of the upper extremities in the standing neutral position and clarified the three-dimensional angular rotations of the upper extremity joints. Methods: Computed tomography (CT) images of 158 upper extremities from 79 healthy volunteers were prospectively acquired in the standing neutral position using an upright CT scanner. Three-dimensional coordinate systems of the thorax, scapula, humerus, and forearm were designated, and three-dimensional angular rotations of the scapulothoracic, glenohumeral, and elbow joints were calculated. Results: The median angle of the scapulothoracic joint was 9.2° (interquartile range [IQR], 5.2°â12.5°) of upward rotation, 29.0° (IQR, 24.9°â33.3°) of internal rotation, and 7.9° (IQR, 4.3°â11.8°) of anterior tilt. The median angle of the glenohumeral joint was 4.5° (IQR, 0.9°â7.8°) of abduction, 9.0° (IQR, 2.2°â19.0°) of internal rotation, and 0.3° (IQR, â 2.6°â3.1°) of extension. The median angle of the elbow joint was 9.8° (IQR, 6.9°â12.4°) of valgus, 90.2° (IQR, 79.6°â99.4°) of pronation, and 15.5° (IQR, 13.2°â18.1°) of flexion. Correlations in angular rotation values were found between the right and left upper extremities and between joints. Conclusions: This study clarified the three-dimensional angular rotation of upper extremity joints in the standing neutral position using an upright CT scanner. Our results may provide important insights for the functional evaluation of upper extremity alignment.
- Open Access
- 1 February 2022
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 2  (1) , 68-74
Reconstruction surgery of intra-articular scapular fracture nonunion: a case report and literature review
- 1 February 2022
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 2  (1) , 68-74
Open AccessReconstruction surgery of intra-articular scapular fracture nonunion: a case report and literature review
- Open Access
- 1 July 2021
- Published by Elsevier in JSES International
- Vol. 5  (4) , 739-744
Risk factors and prognosis of humeral head inferior subluxation in proximal humeral fractures after osteosynthesis
- 1 July 2021
- Published by Elsevier in JSES International
- Vol. 5  (4) , 739-744
Open AccessRisk factors and prognosis of humeral head inferior subluxation in proximal humeral fractures after osteosynthesis
- Open Access
- 26 May 2021
- Published by Elsevier in JSES International
- Vol. 5  (5) , 840-845
Residual coracoclavicular separation after plate fixation for distal clavicle fractures: comparison between fracture patterns
- 26 May 2021
- Published by Elsevier in JSES International
- Vol. 5  (5) , 840-845
Open AccessResidual coracoclavicular separation after plate fixation for distal clavicle fractures: comparison between fracture patterns
- Open Access
- 13 April 2021
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 16  (1) , 1-10
Factors related to large bone defects of bipolar lesions and a high number of instability episodes with anterior glenohumeral instability
Background: Significant bone defects are associated with poor clinical results after surgical stabilization in cases of glenohumeral instability. Although multiple factors are thought to adversely affect enlargement of bipolar bone loss and increased shoulder instability, these factors have not been sufficiently evaluated. The purpose of this study was to identify the factors related to greater bone defects and a higher number of instability episodes in patients with glenohumeral instability.Methods: A total of 120 consecutive patients with symptomatic unilateral instability of the glenohumeral joint were retrospectively reviewed. Three-dimensional surface-rendered/registered models of bilateral glenoids and proximal humeri from computed tomography data were matched by software, and the volumes of bone defects identified in the glenoid and humeral head were assessed. After relationships between objective variables and explanatory variables were evaluated using bivariate analyses, factors related to large bone defects in the glenoid and humeral head and a high number of total instability episodes and self-irreducible dislocations greater than the respective 75th percentiles were evaluated using logistic regression analyses with significant variables on bivariate analyses.Results: Larger humeral head defects (P< .001) and a higher number of total instability episodes (P= .032) were found to be factors related to large glenoid defects. On the other hand, male sex (P= .014), larger glenoid defects (P= .015), and larger number of self-irreducible dislocations (P= .027) were related to large humeral head bone defects. An increased number of total instability episodes was related to longer symptom duration (P= .001) and larger glenoid defects (P= .002), and an increased number of self-irreducible dislocations was related to larger humeral head defects (P= .007).Conclusions: Whereas this study showed that bipolar lesions affect the amount of bone defects reciprocally, factors related to greater bone defects differed between the glenoid and the humeral head. Glenoid defects were related to the number of total instability episodes, whereas humeral head defects were related to the number of self-irreducible dislocations.
- 13 April 2021
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 16  (1) , 1-10
Open AccessFactors related to large bone defects of bipolar lesions and a high number of instability episodes with anterior glenohumeral instability
Background: Significant bone defects are associated with poor clinical results after surgical stabilization in cases of glenohumeral instability. Although multiple factors are thought to adversely affect enlargement of bipolar bone loss and increased shoulder instability, these factors have not been sufficiently evaluated. The purpose of this study was to identify the factors related to greater bone defects and a higher number of instability episodes in patients with glenohumeral instability.Methods: A total of 120 consecutive patients with symptomatic unilateral instability of the glenohumeral joint were retrospectively reviewed. Three-dimensional surface-rendered/registered models of bilateral glenoids and proximal humeri from computed tomography data were matched by software, and the volumes of bone defects identified in the glenoid and humeral head were assessed. After relationships between objective variables and explanatory variables were evaluated using bivariate analyses, factors related to large bone defects in the glenoid and humeral head and a high number of total instability episodes and self-irreducible dislocations greater than the respective 75th percentiles were evaluated using logistic regression analyses with significant variables on bivariate analyses.Results: Larger humeral head defects (P< .001) and a higher number of total instability episodes (P= .032) were found to be factors related to large glenoid defects. On the other hand, male sex (P= .014), larger glenoid defects (P= .015), and larger number of self-irreducible dislocations (P= .027) were related to large humeral head bone defects. An increased number of total instability episodes was related to longer symptom duration (P= .001) and larger glenoid defects (P= .002), and an increased number of self-irreducible dislocations was related to larger humeral head defects (P= .007).Conclusions: Whereas this study showed that bipolar lesions affect the amount of bone defects reciprocally, factors related to greater bone defects differed between the glenoid and the humeral head. Glenoid defects were related to the number of total instability episodes, whereas humeral head defects were related to the number of self-irreducible dislocations.