Shashank D. Chitgopkar
Research Subjects
Research Interests
Latest Publications
- 1 September 2008
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics B
- Vol. 17 (5) , 251-255
Flexible nailing of fractures in children using stainless steel Kirschner wires
Elastic titanium nails are widely used for the established procedure of Elastic Stable Intramedullary Nailing (ESIN), but are costly. Thirty-five diaphyseal fractures in various long bones in children were treated by flexible nailing using stainless steel Kirschner (K) wires. The results were comparable with reports by other authors using titanium nails and stainless steel K wires. Cost-effective K wires and instrumentation are easily available. A stainless steel K wire is 92% cheaper than a Nancy nail and 84% cheaper than a Synthes titanium elastic nail. K wires can be used for flexible nailing of fractures in children with results comparable with those after using titanium nails.
- 1 September 2008
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics B
- Vol. 17 (5) , 251-255
Flexible nailing of fractures in children using stainless steel Kirschner wires
Elastic titanium nails are widely used for the established procedure of Elastic Stable Intramedullary Nailing (ESIN), but are costly. Thirty-five diaphyseal fractures in various long bones in children were treated by flexible nailing using stainless steel Kirschner (K) wires. The results were comparable with reports by other authors using titanium nails and stainless steel K wires. Cost-effective K wires and instrumentation are easily available. A stainless steel K wire is 92% cheaper than a Nancy nail and 84% cheaper than a Synthes titanium elastic nail. K wires can be used for flexible nailing of fractures in children with results comparable with those after using titanium nails.
- Open Access
- 29 March 2005
- Published by Springer Nature in BMC Surgery
- Vol. 5 (1) , 6
Internal fixation of femoral shaft fractures in children by intramedullary Kirschner wires (a prospective study): its significance for developing countries
Background: To evaluate internal fixation by intramedullary Kirschner wires as a surgical technique in the treatment of femoral shaft fractures in children by a prospective study. Methods: 17 femoral shaft fractures at various levels in 16 children aged 2–15 years were treated by closed intramedullary Kirschner wiring under image intensifier control between May 2000 and October 2003. No external splint was used. Results: Fracture union was achieved in 6–14 weeks. Non-weight bearing crutch walking was started 2–3 days after surgery. Full weight bearing started 6–14 weeks. Average operative time was 40 min (range 20–72 min). Wires were removed after 8–22 weeks. There were no infections, no limb length disparity. One child had pin track ulceration. A big child of 14 years had angulation of the fracture. Conclusion: Intramedullary nailing of femoral shaft fractures in children by stainless steel Kirschner wires is an effective method, which compares well with other studies. It is a simple procedure, which can be easily reproduced. Blood loss is minimal, and the operative time short. There is no need pre-bend the wires in a C or S curve. Stainless steel Kirschner wires are cheap, universally available, and can be manufactured locally. The cost of Image intensifiers is affordable in most of the cities of the developing countries. The hospital does not have to maintain a costly inventory. Provides early mobility, return to home and, school. Gives a predictable clinical pathway and reduces occupancy of hospital beds. The technique was successfully applied for internal fixation of other diaphyseal fractures in children and some selected diaphyseal fractures in adults. Based on my experience and a review of the literature, I recommend this technique as a modality for treatment of femoral shaft fractures in children aged 2 to 14 years.
- 29 March 2005
- Published by Springer Nature in BMC Surgery
- Vol. 5 (1) , 6
Open AccessInternal fixation of femoral shaft fractures in children by intramedullary Kirschner wires (a prospective study): its significance for developing countries
Background: To evaluate internal fixation by intramedullary Kirschner wires as a surgical technique in the treatment of femoral shaft fractures in children by a prospective study. Methods: 17 femoral shaft fractures at various levels in 16 children aged 2–15 years were treated by closed intramedullary Kirschner wiring under image intensifier control between May 2000 and October 2003. No external splint was used. Results: Fracture union was achieved in 6–14 weeks. Non-weight bearing crutch walking was started 2–3 days after surgery. Full weight bearing started 6–14 weeks. Average operative time was 40 min (range 20–72 min). Wires were removed after 8–22 weeks. There were no infections, no limb length disparity. One child had pin track ulceration. A big child of 14 years had angulation of the fracture. Conclusion: Intramedullary nailing of femoral shaft fractures in children by stainless steel Kirschner wires is an effective method, which compares well with other studies. It is a simple procedure, which can be easily reproduced. Blood loss is minimal, and the operative time short. There is no need pre-bend the wires in a C or S curve. Stainless steel Kirschner wires are cheap, universally available, and can be manufactured locally. The cost of Image intensifiers is affordable in most of the cities of the developing countries. The hospital does not have to maintain a costly inventory. Provides early mobility, return to home and, school. Gives a predictable clinical pathway and reduces occupancy of hospital beds. The technique was successfully applied for internal fixation of other diaphyseal fractures in children and some selected diaphyseal fractures in adults. Based on my experience and a review of the literature, I recommend this technique as a modality for treatment of femoral shaft fractures in children aged 2 to 14 years.