DDDavid Didierlaurent

David Didierlaurent

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David Didierlaurent has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A new respiratory gating device to improve 4D PET/CT

    by David Didierlaurent, Sophie Ribes, Olivier Caselles, Cyril Jaudet, Jean‐Marc Cazalet, Hadj Batatia, Frédéric Courbon

    Purpose:: Respiratory motion creates artifacts in positon emission tomography with computed tomography (PET/CT) images especially for lung tumors, and can alter diagnosis. To account for motion effects, respiratory gating techniques have been developed. However, the lack of measures strongly correlated with tumor motion limits their accuracy. The authors developed a real‐time pneumotachograph device (SPI) allowing to sort PET and CT images depending on lung volumes.Methods:: The performance of this innovative respiratory tracking system was characterized and compared to a standard system. Our experimental setup consisted in a movable platform and a thorax phantom with six fillable spheres simulating lung tumors. The accuracy of SPI to detect inhalation peaks was also determined on volunteers. A comparison with the real‐time position management (RPM) device, that relies on abdominal height measurement, was then investigated.Results:: Experiments showed a high accuracy of the measured signal compared to the input signal (R = 0.88 to 0.99), and of the detection of the inhalation peaks (error of 0.1 +/− 5.8 ms) necessary for prospective binning mode. Activity recovery coefficient was improved (until +39%) and the smearing effect was reduced (until 2.74 times lower) with SPI compared to ungated PET/CT acquisition. The spatial distribution of activity in spheres was similar for 4D PET gated with SPI and RPM. Significant improvement of the binning stability and matching between PET and CT were highlighted for irregular breathing patterns with SPI.Conclusions:: SPI is an innovative device that provides better binning performance than the current gating device on phantom experiments. Future works will focus on patients where the authors expect a significant improvement of specificity and sensitivity of PET/CT examinations.


  • The retrospective binning method improves the consistency of phase binning in respiratory-gated PET/CT

    by D Didierlaurent, S Ribes, H Batatia, C Jaudet, L O Dierickx, S Zerdoud, S Brillouet, O Caselles, F Courbon

    This study assesses the accuracy of prospective phase-gated PET/CT data binning and presents a retrospective data binning method that improves image quality and consistency. Respiratory signals from 17 patients who underwent 4D PET/CT were analysed to evaluate the reproducibility of temporal triggers used for the standard phase-based gating method. Breathing signals were reprocessed to implement retrospective PET data binning. The mean and standard deviation of time lags between automatic triggers provided by the Real-time Position Management (RPM, Varian) gating device and inhalation peaks derived from respiratory curves were computed for each patient. The total number of respiratory cycles available for 4D PET/CT according to the binning mode (prospective versus retrospective) was compared. The maximum standardized uptake value (SUV(max)), biological tumour volume (BTV) and tumour trajectory measures were determined from the PET/CT images of five patients. Compared to retrospective binning (RB), prospective gating approach led to (i) a significant loss in breathing cycles (15%) and (ii) the inconsistency of data binning due to temporal dispersion of triggers (average 396 ms). Consequently, tumour characterization could be impacted. In retrospective mode, SUV(max) was up to 27% higher, where no significant difference appeared in BTV. In addition, prospective mode gave an inconsistent spatial location of the tumour throughout the bins. Improved consistency with breathing patterns and greater motion amplitude of the tumour centroid were observed with retrospective mode. The detection of the tumour motion and trajectory was improved also for small temporal dispersion of triggers. This study shows that the binning mode could have a significant impact on 4D PET images. The consistency of triggers with breathing signals should be checked before clinical use of gated PET/CT images, and our RB method improves 4D PET/CT image quantification.