J. W. Goodfellow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
J. W. Goodfellow has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
D. W. Murray
Botnar Research Centre, Nuffield Orthopaedic Centre, Headington, Oxford OX3 7LD, UK
1 shared publication- David W. Murray
Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom
1 shared publication - J. J. O'Connor
Department of Engineering Science and Oxford Orthopaedic Engineering Centre, University of Oxford, Oxford, UK
1 shared publication J. J. O’cOnnor
Botnar Research Centre, Nuffield Orthopaedic Centre, Headington, Oxford OX3 7LD, UK
1 shared publication- Peter R. Aldinger
Orthopädische Universitätsklinik Heidelberg
1 shared publication S H White
Nuffield Orthopaedic Centre, Headington, Oxford England
1 shared publication
Latest Publications
- 1 December 2010
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 92-B (12) , 1628-1631
A critique of revision rate as an outcome measure
National registers compare implants by their revision rates, but the validity of the method has never been assessed. The New Zealand Joint Registry publishes clinical outcomes (Oxford knee scores, OKS) alongside revision rates, allowing comparison of the two measurements. In the two types of knee replacement, unicompartmental (UKR) had a better knee score than total replacement (TKR), but the revision rate of the former was nearly three times higher than that of the latter. This was because the sensitivity of the revision rate to clinical failure was different for the two implants. For example, of knees with a very poor outcome (OKS < 20 points), only about 12% of TKRs were revised compared with about 63% of UKRs with similar scores. Revision therefore is not an objective measurement and should not be used to compare these two types of implant. Furthermore, revision is much less sensitive than the OKS to clinical failure in both types and therefore exaggerates the success of knee replacements, particularly of TKR.
- 1 December 2010
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 92-B (12) , 1628-1631
A critique of revision rate as an outcome measure
National registers compare implants by their revision rates, but the validity of the method has never been assessed. The New Zealand Joint Registry publishes clinical outcomes (Oxford knee scores, OKS) alongside revision rates, allowing comparison of the two measurements. In the two types of knee replacement, unicompartmental (UKR) had a better knee score than total replacement (TKR), but the revision rate of the former was nearly three times higher than that of the latter. This was because the sensitivity of the revision rate to clinical failure was different for the two implants. For example, of knees with a very poor outcome (OKS < 20 points), only about 12% of TKRs were revised compared with about 63% of UKRs with similar scores. Revision therefore is not an objective measurement and should not be used to compare these two types of implant. Furthermore, revision is much less sensitive than the OKS to clinical failure in both types and therefore exaggerates the success of knee replacements, particularly of TKR.
- 24 October 2003
- Published by Georg Thieme Verlag KG in Aktuelle Traumatologie
- Vol. 33 (5) , 254-258
Medial Unicompartmental Knee Replacement Using the “Oxford Uni” Meniscal Bearing Knee
Die mediale Schlittenprothese hat gegenüber der totalen Knieprothese viele Vorteile, unter anderem eine bessere Funktion und eine geringere Morbidität. Im Langzeitverlauf sind die Revisionsraten von Schlittenprothesen mit fixiertem Polyethyleneinsatz aufgrund des hohen Polyethylenverschleißes, einer simplen Instrumentierung und einer ungenauen Indikationsstellung jedoch hoch. Der kongruente mobile Polyethyleneinsatz des Oxford-Schlittens zeigt dagegen lediglich einen minimalen Polyethylenabrieb und Versager aus diesem Grund treten nicht auf. Die Instrumentierung ermöglicht eine präzise Implantation mit Wiederherstellung der isometrischen Funktion des Bandapparates. Während der über 20-jährigen Entwicklungszeit wurden die Grenzen dieses Implantates ausgelotet und etwa ein Viertel der Knie, die wegen Osteoarthrose mit einer Knieprothese versorgt werden sollen, sind für dieses Verfahren geeignet. Eine unabhängige Serie, in der die Selektionskriterien eingehalten wurden, zeigte eine 15-Jahres-Überlebensrate von 94 % (95 %-Konfidenzintervall 86 - 100 %). Seit 1998 wurde die Phase-3-Instrumentierung mit modifizierten Instrumenten durch eine minimalinvasive Inzision verwendet, die eine Beschädigung des Extensionsapparates weitgehend vermeidet. Die Patienten erholen sich nun etwa 3-mal schneller als nach einer totalen Knieendoprothese und die Flexionsfähigkeit ist deutlich größer (Mittelwert 135°). Aufgrund der derzeitigen Datenlage kann der minimalinvasive Oxford-Schlitten bei einer korrekten Indikationsstellung und der entsprechenden operativen Erfahrung als primäre Therapieoption bei medialer Gonarthrose ernsthaft in Betracht gezogen werden. Medial unicompartmental knee replacement (UKR) has many advantages over total replacement (TKR) including better function and less morbidity. However, the long-term failure rates of fixed-bearing UKR are high because of polyethylene wear, lack of sophisticated instrumentation and imprecise patient selection. The fully congruent mobile bearing of the Oxford UKR exhibits minimal polyethylene wear and failure from this cause does not occur. The instrumentation allows precise implantation to restore isometric function to the ligaments. During its 20 years development, the limits of usefulness of the implant have been established and found to include about one in four knees requiring replacement for osteoarthritis. In an independent series, using these criteria, the 15 year survival was 94 % (CI 86 % to 100 %). Since 1998, the Phase 3 implant has been used with modified instruments through a small incision, avoiding damage to the extensor mechanism. Patients now recover about three times faster than after TKR, and regain much better flexion (mean 135°). The current evidence supports that the minimally invasive Oxford UKR should be seriously considered as primary treatment and discussed with the patient presenting with anteromedial compartment osteoarthritis provided the correct indication and the appropriate surgical expertise is available.
- 24 October 2003
- Published by Georg Thieme Verlag KG in Aktuelle Traumatologie
- Vol. 33 (5) , 254-258
Medial Unicompartmental Knee Replacement Using the “Oxford Uni” Meniscal Bearing Knee
Die mediale Schlittenprothese hat gegenüber der totalen Knieprothese viele Vorteile, unter anderem eine bessere Funktion und eine geringere Morbidität. Im Langzeitverlauf sind die Revisionsraten von Schlittenprothesen mit fixiertem Polyethyleneinsatz aufgrund des hohen Polyethylenverschleißes, einer simplen Instrumentierung und einer ungenauen Indikationsstellung jedoch hoch. Der kongruente mobile Polyethyleneinsatz des Oxford-Schlittens zeigt dagegen lediglich einen minimalen Polyethylenabrieb und Versager aus diesem Grund treten nicht auf. Die Instrumentierung ermöglicht eine präzise Implantation mit Wiederherstellung der isometrischen Funktion des Bandapparates. Während der über 20-jährigen Entwicklungszeit wurden die Grenzen dieses Implantates ausgelotet und etwa ein Viertel der Knie, die wegen Osteoarthrose mit einer Knieprothese versorgt werden sollen, sind für dieses Verfahren geeignet. Eine unabhängige Serie, in der die Selektionskriterien eingehalten wurden, zeigte eine 15-Jahres-Überlebensrate von 94 % (95 %-Konfidenzintervall 86 - 100 %). Seit 1998 wurde die Phase-3-Instrumentierung mit modifizierten Instrumenten durch eine minimalinvasive Inzision verwendet, die eine Beschädigung des Extensionsapparates weitgehend vermeidet. Die Patienten erholen sich nun etwa 3-mal schneller als nach einer totalen Knieendoprothese und die Flexionsfähigkeit ist deutlich größer (Mittelwert 135°). Aufgrund der derzeitigen Datenlage kann der minimalinvasive Oxford-Schlitten bei einer korrekten Indikationsstellung und der entsprechenden operativen Erfahrung als primäre Therapieoption bei medialer Gonarthrose ernsthaft in Betracht gezogen werden. Medial unicompartmental knee replacement (UKR) has many advantages over total replacement (TKR) including better function and less morbidity. However, the long-term failure rates of fixed-bearing UKR are high because of polyethylene wear, lack of sophisticated instrumentation and imprecise patient selection. The fully congruent mobile bearing of the Oxford UKR exhibits minimal polyethylene wear and failure from this cause does not occur. The instrumentation allows precise implantation to restore isometric function to the ligaments. During its 20 years development, the limits of usefulness of the implant have been established and found to include about one in four knees requiring replacement for osteoarthritis. In an independent series, using these criteria, the 15 year survival was 94 % (CI 86 % to 100 %). Since 1998, the Phase 3 implant has been used with modified instruments through a small incision, avoiding damage to the extensor mechanism. Patients now recover about three times faster than after TKR, and regain much better flexion (mean 135°). The current evidence supports that the minimally invasive Oxford UKR should be seriously considered as primary treatment and discussed with the patient presenting with anteromedial compartment osteoarthritis provided the correct indication and the appropriate surgical expertise is available.
- 1 March 1991
- Vol. 73 (2) , 268-70
Sagittal plane laxity following knee arthroplasty.
We measured the sagittal laxity in 70 knee replacements at least six months after surgery, using a KT 1000 arthrometer. With an unconstrained prosthesis (the Oxford meniscal knee) anteroposterior stability was normal in joints known to have intact cruciate ligaments. There was increased laxity in those which lacked an anterior cruciate ligament. In knees with an intact anterior cruciate ligament, sagittal laxity did not increase with time.
- 1 March 1991
- Vol. 73 (2) , 268-70
Sagittal plane laxity following knee arthroplasty.
We measured the sagittal laxity in 70 knee replacements at least six months after surgery, using a KT 1000 arthrometer. With an unconstrained prosthesis (the Oxford meniscal knee) anteroposterior stability was normal in joints known to have intact cruciate ligaments. There was increased laxity in those which lacked an anterior cruciate ligament. In knees with an intact anterior cruciate ligament, sagittal laxity did not increase with time.