Arijeet Das
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Arijeet Das has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
R. J. Choudhari
UGC-DAE Consortium for Scientific Research, Indore, Madhya Pradesh 452017, India
2 shared publicationsS. K. Rai
Raja Ramanna Centre for Advanced Technology RRCAT 452013 Indore Pradesh Madhya India
2 shared publicationsTapas Ganguli
Raja Ramanna Centre for Advanced Technology RRCAT 452013 Indore Pradesh Madhya India
2 shared publicationsA. Srivastava
Indus Synchrotron Utilization Division, Raja Ramanna Centre for Advanced Technology, Indore, India 452013
1 shared publicationAlka B. Garg
1 shared publication- Aniruddha Bose
SCRF Cavity Characterization and Cryogenics Section, Raja Ramanna Centre for Advanced Technology 5 , Indore 452013, India
1 shared publication
Latest Publications
- 24 August 2018
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 51 (5) , 1295-1303
Data-reduction procedure for correction of geometric factors in the analysis of specular X-ray reflectivity of small samples
For small samples, the modification of the X-ray reflectivity (XRR) profile by the geometric factors due to the profile and size of the beam and the size of the sample is significant. These geometric factors extend the spill-over angle, which is often greater than the critical angle for small samples. To separate the geometric factors, it is necessary to know the spill-over angle. Since the geometric factors are smoothly varying functions and extend beyond the critical angle, it is impossible to determine the spill-over angle from the XRR profile of small samples. It is shown that the spill-over angle can be determined by comparing the normal XRR profile of a small sample with the XRR profile taken with a surface-contact knife edge on the same sample. Thus, a procedure has been developed for data reduction for small samples and validated with suitable experiments. Unlike the methods used hitherto, which have drawbacks, this is a self-consistent method for data reduction.
- 24 August 2018
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 51 (5) , 1295-1303
Data-reduction procedure for correction of geometric factors in the analysis of specular X-ray reflectivity of small samples
For small samples, the modification of the X-ray reflectivity (XRR) profile by the geometric factors due to the profile and size of the beam and the size of the sample is significant. These geometric factors extend the spill-over angle, which is often greater than the critical angle for small samples. To separate the geometric factors, it is necessary to know the spill-over angle. Since the geometric factors are smoothly varying functions and extend beyond the critical angle, it is impossible to determine the spill-over angle from the XRR profile of small samples. It is shown that the spill-over angle can be determined by comparing the normal XRR profile of a small sample with the XRR profile taken with a surface-contact knife edge on the same sample. Thus, a procedure has been developed for data reduction for small samples and validated with suitable experiments. Unlike the methods used hitherto, which have drawbacks, this is a self-consistent method for data reduction.
- Open Access
Data reduction procedure for correction of geometrical factors in the analysis of specular x-ray reflectivity of small samples
For small samples, the modification of the XRR profile by the geometrical factors manifesting due to profile and size of the beam and the size of the sample is significant. Geometrical factors extend till spill over angle which is often greater than critical angle for small samples. To separate the geometrical factor, it is necessary to know the spill over angle. Since geometrical factor is a smoothly varying function and extends beyond critical angle, it is impossible to determine the spill over angle from XRR profile of small samples. We have shown by comparing the normal XRR profile of a small sample with the XRR profile taken with a surface contact knife edge on the same sample, that the spill over angle can be determined. Thus we have developed a procedure for data reduction for small samples and validated it with suitable experiments. Unlike hitherto used methods which have drawbacks, this is a self consistent method for data reduction
Open AccessData reduction procedure for correction of geometrical factors in the analysis of specular x-ray reflectivity of small samples
For small samples, the modification of the XRR profile by the geometrical factors manifesting due to profile and size of the beam and the size of the sample is significant. Geometrical factors extend till spill over angle which is often greater than critical angle for small samples. To separate the geometrical factor, it is necessary to know the spill over angle. Since geometrical factor is a smoothly varying function and extends beyond critical angle, it is impossible to determine the spill over angle from XRR profile of small samples. We have shown by comparing the normal XRR profile of a small sample with the XRR profile taken with a surface contact knife edge on the same sample, that the spill over angle can be determined. Thus we have developed a procedure for data reduction for small samples and validated it with suitable experiments. Unlike hitherto used methods which have drawbacks, this is a self consistent method for data reduction
- 19 October 2012
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (30) , 7402-7410
Fine structures in refractive index of sapphire at the LII,III absorption edge of aluminum determined by soft x-ray resonant reflectivity
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 19 October 2012
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (30) , 7402-7410
Fine structures in refractive index of sapphire at the LII,III absorption edge of aluminum determined by soft x-ray resonant reflectivity
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 11 July 2011
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1349 (1) , 783
Investigation of the Influence of Buffer Layer on the Interface Roughness of NbC∕Si Multilayer
The influence of buffer layer on interface roughness has been investigated. With Si buffer layer, NbC/Si multilayer mirrors show 28% increase of reflectivity at Bragg peak for Reduction in physical and chemical roughness in the multilayer with buffer layer was calculated by fitting both specular and diffused scattering data.- 11 July 2011
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1349 (1) , 783
Investigation of the Influence of Buffer Layer on the Interface Roughness of NbC∕Si Multilayer
The influence of buffer layer on interface roughness has been investigated. With Si buffer layer, NbC/Si multilayer mirrors show 28% increase of reflectivity at Bragg peak for Reduction in physical and chemical roughness in the multilayer with buffer layer was calculated by fitting both specular and diffused scattering data.