ACAshleigh Cousins

Ashleigh Cousins

*This is an algorithmically generated author record based on publicly available information.

Ashleigh Cousins has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Understanding the Application Envelope for Metal Hydride Compressors (Techno-Economic Considerations)

    by Ashleigh Cousins, Nikolai Kinaev, Sandy Edwards, Matt Langley, Evan MacA. Gray

    Currently, H2 compression is one of the highest-cost items, both in terms of capital and operating costs, at H2 refuelling stations. Metal hydride (MH) compressors are an alternative H2 compression technology, which uses heat rather than electricity to provide the driving force for compression. Where waste heat is available, these compressors have the potential to be lower in cost than current mechanical alternatives. While the development of metal hydride compressors has been underway for the last 40–50 years, only a few have made it through to demonstration at industrial sites. To better understand where these compressors see best potential, we have completed a high-level assessment of the levelised costs associated with MH compression. We explore the impact of cost assumptions (capital and operating cost items) on the overall cost of MH compression over an assumed 10-year life. Results indicate that MH compressors have similar capital costs to currently available mechanical compressors but have a significant advantage in operating costs where waste or solar heat is available. This analysis highlights that it is the cost of energy that has the greatest impact on the cost competitiveness of the metal hydride compressor.


  • Open Access

    Metal Hydride Composite Structures for Improved Heat Transfer and Stability for Hydrogen Storage and Compression Applications

    by Liang Liu, Alexander Ilyushechkin, Daniel Liang, Ashleigh Cousins, Wendy Tian, Cherry Chen, Jon Yin, Liezl Schoeman

    Metal alloys and intermetallic compounds offer an attractive method for safely storing hydrogen (H2). The metal alloys absorb H2 into their structure, often swelling and fracturing as a result of phase transformation during hydride formation/decomposition cycles. The absorption of H2 is an exothermic process, requiring the effective and efficient removal of heat. This can be challenging as heat transfer to/from powdered beds is notoriously difficult, and often limited by poor thermal conductivity. Hence, the observed reaction kinetics for absorption and desorption of H2 is dominated by heat flow. The most common method for improving the thermal conductivity of the alloy powders is to prepare them into composite structures with other high thermal conductivity materials, such as carbons and expanded natural graphite. Such composite structures, some also combined with polymers/resins, can also mitigate safety issues related to swelling and improve cyclic durability. This paper reviews the methods that have been used to prepare such composite structures and evaluates the observed impact on thermal conductivity.


  • Achieving Zero/Negative-Emissions Coal-Fired Power Plants Using Amine-Based Postcombustion CO2 Capture Technology and Biomass Cocombustion

    by Kaiqi Jiang, Paul H. M. Feron, Ashleigh Cousins, Rongrong Zhai, Kangkang Li

    The strengthening carbon mitigation efforts to meet the 1.5 °C target, requires the development of zero/negative CO2 emission technologies to eliminate large direct CO2 emissions from fossil-fuel fired power stations. Amine scrubbing is a dominant technology to capture CO2 from fossil-fuel power stations, but its application in achieving zero/negative emission in power stations is rarely reported. The present study investigates the MEA-based technologies to achieve zero and negative CO2 emission in coal-fired power stations, and their techno-economic performance was evaluated in detail. These zero/negative-emission technologies include 99.7% CO2 capture from flue gas (zero emission), biomass co-combustion with coal integrated with CO2 capture at ratios of 10% biomass/90% CO2 capture and 5% biomass/95% CO2 capture (zero-emission), and 10% biomass/95% CO2 capture for negative-emission power station. Our investigation revealed that these zero/negative-emission technologies are technically and economically viable, and their CO2 avoided costs did not significantly increase compared to the standard 90% CO2 capture. The CO2 avoided cost for 99.7%-capture is estimated at $66.5/tonne CO2, which is $2.6/tonne CO2¬ higher than tht of 90%-capture. The biomass co-combustion zero/negative-emission technologies show better economic performance with CO2 avoided cost of $64.1-64.8/tonne CO2, which is only $0.2-0.7/tonne CO2 higher than the standard 90%-capture. These results indicate that the amine-based CO2 capture integrated with biomass co-combustion technology would be economically competitive to achieve zero or even negative CO2 emissions in coal-fired power stations.


  • Simulating combined SO2 and CO2 capture from combustion flue gas

    by Ashleigh Cousins, Pauline Pearson, Graeme Puxty, Kaiqi Jiang, Bharti Garg, Rongrong Zhai, Pedro Ott, Vince Verheyen, Paul H. M. Feron

    The requirement to pre‐treat flue gas prior to the CO2 capture step is an economic challenge when using aqueous amine absorbents for capturing CO2 from coal‐fired power station flue gases. A potentially lower cost alternative is to combine the capture of both CO2 and SO2 from the flue gas into a single process, removing the requirement for the desulfurization pre‐treatment step. The CSIRO's CS‐Cap process uses a single aqueous amine absorbent to capture both of these acid gases from flue gas streams. This paper covers the initial simulation of this process applied to both brown and black coal flue gases. Removal of absorbed SO2 is achieved via reactive crystallization. This is simulated here using a ‘black box’ process, resulting in a K2SO4 product. Different operating conditions have been evaluated that increase the sulfate concentration of the absorbent in the SO2 capture section of the process, which is expected to increase the efficiency of the reactive crystallization step. This paper provides information on the absorption of SO2 into the amine solution, and heat and mass balances for the wider process. This information will be required for further detailed simulation of the reactive crystallization step, and economic evaluation of the CS‐Cap process. © 2019 Society of Chemical Industry and John Wiley & Sons, Ltd.


  • Open Access

    Long Term Evaluation of Advanced PCC System for Coal-fired Power Plant

    by Jun Arakawa, Shinya Okuno, Kenji Takano, Yasuro Yamanaka, Toshiya Matsuyama, Paul Feron, Aaron Cottrell, Ashleigh Cousins, Sanger Huang, Roland Davies, et al.


  • Open Access

    Understanding and Modelling the Effect of Dissolved Metals on Solvent Degradation in Post Combustion CO2 Capture Based on Pilot Plant Experience

    by Sanjana Dhingra, Purvil Khakharia, Alexander Rieder, Ashleigh Cousins, Alicia Reynolds, Jacob Knudsen, Jimmy Andersen, Robin Irons, Jan Mertens, Mohammad Abu Zahra, et al.

    Oxidative degradation is a serious concern for upscaling of amine-based carbon capture technology. Different kinetic models have been proposed based on laboratory experiments, however the kinetic parameters included are limited to those relevant for a lab-scale system and not a capture plant. Besides, most of the models fail to recognize the catalytic effect of metals. The objective of this work is to develop a representative kinetic model based on an apparent auto-catalytic reaction mechanism between solvent degradation, corrosion and ammonia emissions. Measurements from four different pilot plants: (i) EnBW’s plant at Heilbronn, Germany (ii) TNO’s plant at Maasvlakte, The Netherlands; (iii) CSIRO’s plants at Loy Yang and Tarong, Australia and (iv) DONG Energy’s plant at Esbjerg, Denmark are utilized to propose a degradation kinetic model for 30 wt % ethanolamine (MEA) as the capture solvent. The kinetic parameters of the model were regressed based on the pilot plant campaign at EnBW. The kinetic model was validated by comparing it with the measurements at the remaining pilot campaigns. The model predicted the trends of ammonia emissions and metal concentration within the same order of magnitude. This study provides a methodology to establish a quantitative approach for predicting the onset of unacceptable degradation levels which can be further used to devise counter-measure strategies such as reclaiming and metal removal.


  • Pilot‐scale evaluation of concentrated piperazine for CO2 capture at an Australian coal‐fired power station: duration experiments

    by Ashleigh Cousins, Paul Nielsen, Sanger Huang, Aaron Cottrell, Eric Chen, Gary T Rochelle, Paul H M Feron

    Duration operation was completed as the final stage of evaluating concentrated piperazine as a CO2 capture solvent at the Tarong pilot plant. For the duration tests, a single operating set‐point was maintained for an extended period of time. The purpose of the duration tests was to monitor the formation of degradation products and the robustness of the solvent. Two duration tests were conducted that differed only in the regeneration temperature used (125 or 155 °C). Four hundred twenty‐five hours of operation were achieved on the solvent with a regeneration temperature of 125 °C. This was followed by a further 421 h of operation with a regeneration temperature of 155 °C, giving a total operating time on the solvent of 1700 h by the end of the project. For the duration experiments, roughly 500 tonnes of flue gas was treated, and approximately 70 tonnes of CO2 captured. The heat stable salt (HSS) measured in highest concentration was formate, with the rate of formation increasing with regeneration temperature. The effect of pre‐treatment could be seen with sulfate concentration in the solvent increasing sharply when caustic supply to the pre‐treatment column was interrupted. Despite the formation of degradation products in the solvent regeneration energy requirements were not notably effected. For operation up to 1700 h on a real coal flue gas, no loss of plant performance was observed. © 2015 Society of Chemical Industry and John Wiley & Sons, Ltd


  • Pilot‐scale parametric evaluation of concentrated piperazine for CO2 capture at an Australian coal‐fired power station

    by Ashleigh Cousins, Sanger Huang, Aaron Cottrell, Paul H.M. Feron, Eric Chen, Gary T. Rochelle

    Concentrated piperazine (PZ) is a promising new solvent under consideration for post‐combustion capture (PCC) of CO2. A solution of 8 molal PZ was recently evaluated at the Tarong CO2 capture pilot plant in Australia. Initial operation involved evaluation of different operating conditions at the plant to determine the minimum energy conditions for this solvent. Comparison was made to results achieved previously at the same pilot plant with 30 wt% monoethanolamine (MEA). Regeneration energy requirements achieved with concentrated PZ were consistently lower than those achieved with MEA. The lowest regeneration energy for PZ at the pilot plant (2.9 MJ/kgCO2) was roughly 15% lower than the best result predicted for MEA. Inter‐cooling located at the center of the absorber column was also evaluated for the concentrated PZ solvent. The benefit of inter‐cooling was found to depend on the operating conditions of the plant, with operation at higher liquid‐to‐gas (L/G) ratios showing a more pronounced effect. For an L/G ratio of 3.3 kg/kg, inter‐cooling was found to lower the regeneration energy required for PZ by approximately 10%.


  • Corrosion coupon evaluation under pilot‐scale CO2 capture conditions at an Australian coal‐fired power station

    by Ashleigh Cousins, Alexander Ilyushechkin, Pauline Pearson, Aaron Cottrell, Sanger Huang, Paul H.M. Feron

    Corrosion is a major operational issue in amine treating plants. With the likely application of CO2 capture technologies to coal combustion flue gases, corrosion rates in gas streams containing oxygen are of interest and evaluation of potential construction materials under realistic conditions is essential. A total of 128 corrosion coupons were installed at the Tarong Post Combustion Capture (PCC) pilot plant in 8 locations during operation with 30 wt% monoethanolamine (MEA). Each corrosion test location contained 4 coupons of each type of metal (316L, 316L welded, C1018, C1018 galvanized). Coupons were installed in the pilot plant for 4296 or 5448 h; however plant operation was intermittent with actual operating times of 593 or 745 h. The highest corrosion rates were observed for carbon steel (C1018) and galvanized carbon steel (C1018 GLV) coupons located in both the absorber and stripper solvent storage tanks. C1018 GLV coupons typically showed higher rates of corrosion than C1018 coupons. C1018 coupons located in the absorber wash section also exhibited high corrosion rates, while C1018 GLV coupons in the same location did not. XRD analysis showed that the galvanized coupons in the absorber wash section retained some Zn in the corrosion scale. This could have aided their resistance to corrosion in this location. All other galvanized samples lost their zinc coating, indicating galvanizing might not be appropriate for use in CO2 capture applications. C1018 coupons in the absorber column experienced pitting. This was not seen for the galvanized coupons. In the stripping column, both the C1018 and C1018 GLV coupons showed areas of general corrosion attack. Stainless steel and welded stainless steel coupons showed no appreciable corrosion weight loss under the conditions tested. The corrosion resistance of the 316L stainless steel coupons to all environments considered here suggests it is suitable for use in all areas of amine based PCC plants. The corrosion rates measured on C1018 and C1018 GLV coupons suggest these materials would not be recommended for use in solvent storage tanks or wash sections of PCC plants. Due to intermittent use of the plant, it is unclear from these results whether C1018 or C1018 GLV would be suitable for use in the absorption/desorption columns. © 2013 Society of Chemical Industry and John Wiley & Sons, Ltd.