Jonas Högberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jonas Högberg has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Magnus Rizell
Department of Surgery, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
4 shared publications - Ragnar Hultborn
Department of Oncology, Sahlgrenska University Hospital, SE-41346, Gothenburg, Sweden
4 shared publications - Johan Mölne
University of Gothenburg
3 shared publications - Johanna Svensson
Department of Oncology, Sahlgrenska University Hospital, SE-41346, Gothenburg, Sweden
3 shared publications Olof Henrikson
Department of Radiology, Sahlgrenska University Hospital, SE-41346, Gothenburg, Sweden
2 shared publications- Olof Henrikson
Department of Radiology, Sahlgrenska University Hospital, SE-41346, Gothenburg, Sweden
2 shared publications
Latest Publications
- Open Access
- 13 May 2016
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 96 (2) , 414-421
Simulation Model of Microsphere Distribution for Selective Internal Radiation Therapy Agrees With Observations
- 13 May 2016
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 96 (2) , 414-421
Open AccessSimulation Model of Microsphere Distribution for Selective Internal Radiation Therapy Agrees With Observations
- Open Access
- 26 April 2015
- Published by Springer Nature in EJNMMI Physics
- Vol. 2 (1) , 1-17
Increased absorbed liver dose in Selective Internal Radiation Therapy (SIRT) correlates with increased sphere-cluster frequency and absorbed dose inhomogeneity
The higher tolerated mean absorbed dose for selective internal radiation therapy (SIRT) with intra-arterially infused 90Y microspheres compared to external beam therapy is speculated to be caused by absorbed dose inhomogeneity, which allows for liver regeneration. However, the complex liver microanatomy and rheology makes modelling less valuable if the tolerance doses are not based on the actual microsphere distribution. The present study demonstrates the sphere distribution and small-scale absorbed dose inhomogeneity and its correlation with the mean absorbed dose in liver tissue resected after SIRT. A patient with marginally resectable cholangiocarcinoma underwent SIRT 9 days prior to resection including adjacent normal liver tissue. The resected specimen was formalin-fixed and sliced into 1 to 2-mm sections. Forty-one normal liver biopsies 6-8 mm in diameter were punched from these sections and the radioactivity measured. Sixteen biopsies were further processed for detailed analyses by consecutive serial sectioning of 15 30-μm sections per biopsy, mounted and stained with haematoxylin-eosin. All sections were scrutinised for isolated or conglomerate spheres. Small-scale dose distributions were obtained by applying a 90Y-dose point kernel to the microsphere distributions. A total of 3888 spheres were found in the 240 sections. Clusters were frequently found as strings in the arterioles and as conglomerates in small arteries, with the largest cluster comprising 453 spheres. An increased mean absorbed dose in the punch biopsies correlated with large clusters and a greater coefficient of variation. In simulations the absorbed dose was 5–1240 Gy; 90% were 10-97 Gy and 45% were <30 Gy, the assumed tolerance in external beam therapy. Sphere clusters were located in both arterioles and small arteries and increased in size with increasing sphere concentration, resulting in increased absorbed dose inhomogeneity, which contradicts earlier modelling studies.
- 26 April 2015
- Published by Springer Nature in EJNMMI Physics
- Vol. 2 (1) , 1-17
Open AccessIncreased absorbed liver dose in Selective Internal Radiation Therapy (SIRT) correlates with increased sphere-cluster frequency and absorbed dose inhomogeneity
The higher tolerated mean absorbed dose for selective internal radiation therapy (SIRT) with intra-arterially infused 90Y microspheres compared to external beam therapy is speculated to be caused by absorbed dose inhomogeneity, which allows for liver regeneration. However, the complex liver microanatomy and rheology makes modelling less valuable if the tolerance doses are not based on the actual microsphere distribution. The present study demonstrates the sphere distribution and small-scale absorbed dose inhomogeneity and its correlation with the mean absorbed dose in liver tissue resected after SIRT. A patient with marginally resectable cholangiocarcinoma underwent SIRT 9 days prior to resection including adjacent normal liver tissue. The resected specimen was formalin-fixed and sliced into 1 to 2-mm sections. Forty-one normal liver biopsies 6-8 mm in diameter were punched from these sections and the radioactivity measured. Sixteen biopsies were further processed for detailed analyses by consecutive serial sectioning of 15 30-μm sections per biopsy, mounted and stained with haematoxylin-eosin. All sections were scrutinised for isolated or conglomerate spheres. Small-scale dose distributions were obtained by applying a 90Y-dose point kernel to the microsphere distributions. A total of 3888 spheres were found in the 240 sections. Clusters were frequently found as strings in the arterioles and as conglomerates in small arteries, with the largest cluster comprising 453 spheres. An increased mean absorbed dose in the punch biopsies correlated with large clusters and a greater coefficient of variation. In simulations the absorbed dose was 5–1240 Gy; 90% were 10-97 Gy and 45% were <30 Gy, the assumed tolerance in external beam therapy. Sphere clusters were located in both arterioles and small arteries and increased in size with increasing sphere concentration, resulting in increased absorbed dose inhomogeneity, which contradicts earlier modelling studies.
- Open Access
- 16 September 2014
- Published by Springer Nature in EJNMMI Research
- Vol. 4 (1) , 48
Heterogeneity of microsphere distribution in resected liver and tumour tissue following selective intrahepatic radiotherapy
Selective arterial radioembolisation of liver tumours has increased, because of encouraging efficacy reports; however, therapeutic parameters used in external beam therapy are not applicable for understanding and predicting potential toxicity and efficacy, necessitating further studies of the physical and biological characteristics of radioembolisation. The aim was to characterise heterogeneity in the distribution of microspheres on a therapeutically relevant geometric scale considering the range of yttrium-90 (90Y) β-particles. Two patients with intrahepatic cholangiocarcinoma, marginally resectable, were treated by selective arterial embolisation with 90Y resin microspheres (SIRTEX®), followed 9 days post-infusion by resection, including macroscopic tumour tissue and surrounding normal liver parenchyma. Formalin-fixed, sectioned resected tissues were exposed to autoradiographic films, or tissue biopsies of various dimensions were punched out for activity measurements and microscopy. Autoradiography and activity measurements revealed a higher activity in tumour tissue compared to normal liver parenchyma. Heterogeneity in activity distribution was evident in both normal liver and tumour tissue. Activity measurements were analysed in relation to the sample mass (5 to 422 mg), and heterogeneities were detected by statistical means; the larger the tissue biopsies, the smaller was the coefficient of variation. The skewness of the activity distributions increased with decreasing biopsy mass. The tissue activity distributions in normal tissue were heterogeneous on a relevant geometric scale considering the range of the ionising electrons. Given the similar and repetitive structure of the liver parenchyma, this finding could partly explain the tolerance of a relatively high mean absorbed dose to the liver parenchyma from β-particles.
- 16 September 2014
- Published by Springer Nature in EJNMMI Research
- Vol. 4 (1) , 48
Open AccessHeterogeneity of microsphere distribution in resected liver and tumour tissue following selective intrahepatic radiotherapy
Selective arterial radioembolisation of liver tumours has increased, because of encouraging efficacy reports; however, therapeutic parameters used in external beam therapy are not applicable for understanding and predicting potential toxicity and efficacy, necessitating further studies of the physical and biological characteristics of radioembolisation. The aim was to characterise heterogeneity in the distribution of microspheres on a therapeutically relevant geometric scale considering the range of yttrium-90 (90Y) β-particles. Two patients with intrahepatic cholangiocarcinoma, marginally resectable, were treated by selective arterial embolisation with 90Y resin microspheres (SIRTEX®), followed 9 days post-infusion by resection, including macroscopic tumour tissue and surrounding normal liver parenchyma. Formalin-fixed, sectioned resected tissues were exposed to autoradiographic films, or tissue biopsies of various dimensions were punched out for activity measurements and microscopy. Autoradiography and activity measurements revealed a higher activity in tumour tissue compared to normal liver parenchyma. Heterogeneity in activity distribution was evident in both normal liver and tumour tissue. Activity measurements were analysed in relation to the sample mass (5 to 422 mg), and heterogeneities were detected by statistical means; the larger the tissue biopsies, the smaller was the coefficient of variation. The skewness of the activity distributions increased with decreasing biopsy mass. The tissue activity distributions in normal tissue were heterogeneous on a relevant geometric scale considering the range of the ionising electrons. Given the similar and repetitive structure of the liver parenchyma, this finding could partly explain the tolerance of a relatively high mean absorbed dose to the liver parenchyma from β-particles.
- 18 October 2012
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 32 (4) , 439-446
Radiation exposure during liver surgery after treatment with90Y microspheres, evaluated with computer simulations and dosimeter measurements
Purpose. Two patients with liver tumours were planned for a combined treatment, including surgery with preceding injections of beta(-) radiation emitting Y-90 microspheres (SIRTEX (R)).The aim of this paper is to present a method of pre-surgical computer simulations of the absorbed dose rate on the surface of tumour tissue, combined with measurements of the actual absorbed dose rate on resected tissue, in order to estimate the absorbed dose to a surgeon's fingers during such surgery procedures. Methods and Materials. The dose rates from beta(-) radiation on the surface of tumour tissue were simulated with the software VARSKIN (R) Mod 2. The activity concentrations in tumours were estimated, based on SPECT/CT distribution studies of Tc-99m-MAA and confirmed by SPECT/CT bremsstrahlung studies of Y-90 microspheres. The activity distributions were considered as homogeneous within the tumour regions. The absorbed dose rates at different tumour tissue spots were calculated based on measurements with thermo-luminescent dosimeters (TLD) fastened on resected tissue. Results. The simulations showed a good agreement with the averaged absorbed dose rates based on TLD measurements performed on resected tissue, differing by 13% and 4% respectively. The absorbed dose rates at the measured maximum hotspots were twice as high as the average dose rates for both patients. Conclusion. The data is not sufficient in order to draw any general conclusions about dose rates on tumour tissue during similar surgeries, neither about the influence of dose rate heterogeneities nor about average dose rates. However, the agreement between simulations and measurements on these limited data indicate that this approach is a promising method for estimations of the radiation exposure to the surgeons' fingers during this kind of surgery procedure. More data from similar surgeries are necessary in order to validate the method.
- 18 October 2012
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 32 (4) , 439-446
Radiation exposure during liver surgery after treatment with90Y microspheres, evaluated with computer simulations and dosimeter measurements
Purpose. Two patients with liver tumours were planned for a combined treatment, including surgery with preceding injections of beta(-) radiation emitting Y-90 microspheres (SIRTEX (R)).The aim of this paper is to present a method of pre-surgical computer simulations of the absorbed dose rate on the surface of tumour tissue, combined with measurements of the actual absorbed dose rate on resected tissue, in order to estimate the absorbed dose to a surgeon's fingers during such surgery procedures. Methods and Materials. The dose rates from beta(-) radiation on the surface of tumour tissue were simulated with the software VARSKIN (R) Mod 2. The activity concentrations in tumours were estimated, based on SPECT/CT distribution studies of Tc-99m-MAA and confirmed by SPECT/CT bremsstrahlung studies of Y-90 microspheres. The activity distributions were considered as homogeneous within the tumour regions. The absorbed dose rates at different tumour tissue spots were calculated based on measurements with thermo-luminescent dosimeters (TLD) fastened on resected tissue. Results. The simulations showed a good agreement with the averaged absorbed dose rates based on TLD measurements performed on resected tissue, differing by 13% and 4% respectively. The absorbed dose rates at the measured maximum hotspots were twice as high as the average dose rates for both patients. Conclusion. The data is not sufficient in order to draw any general conclusions about dose rates on tumour tissue during similar surgeries, neither about the influence of dose rate heterogeneities nor about average dose rates. However, the agreement between simulations and measurements on these limited data indicate that this approach is a promising method for estimations of the radiation exposure to the surgeons' fingers during this kind of surgery procedure. More data from similar surgeries are necessary in order to validate the method.