VCVincent Cottenceau

Vincent Cottenceau

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vincent Cottenceau has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Higher than standard dosing regimen are needed to achieve optimal antibiotic exposure in critically ill patients with augmented renal clearance receiving piperacillin-tazobactam administered by continuous infusion

    by Cédric Carrié, Rachel Legeron, Laurent Petit, Julien Ollivier, Vincent Cottenceau, Nicolas D'HOudain, Philippe Boyer, Mélanie Lafitte, Fabien Xuereb, François Sztark, et al.


  • Assessment of White Matter Injury and Outcome in Severe Brain Trauma. A Prospective Multicenter Cohort

    by Damien Galanaud, Vincent Perlbarg, Rajiv Gupta, Robert D. Stevens, Paola Sanchez, Eléonore Tollard, Nicolas Menjot De Champfleur, Julien Dinkel, Sébastien Faivre, Gustavo Stot-Ares, et al.


  • Open Access

    Subclavian central venous catheter-related thrombosis in trauma patients: incidence, risk factors and influence of polyurethane type

    by Ariane Gentile, Laurent Petit, Françoise Masson, Vincent Cottenceau, Josseline Bertrand-Barat, Geneviève Freyburger, Catherine Pinaquy, Alain Léger, Jean-François Cochard, François Sztark

    Introduction: The incidence of deep venous thrombosis (DVT) related to a central venous catheter varies considerably in ICUs depending on the population included. The aim of this study was to determine subclavian central venous catheter (SCVC)-related DVT risk factors in severely traumatized patients with regard to two kinds of polyurethane catheters. Methods: Critically ill trauma patients needing a SCVC for their usual care were prospectively included in an observational study. Depending on the month of inclusion, patients received one of the two available products in the emergency unit: either an aromatic polyurethane SCVC or an aliphatic polyurethane SCVC. Patients were screened weekly by ultrasound for SCVC-related DVT. Potential risk factors were collected, including history-related, trauma-related and SCVC-related characteristics. Results: A total of 186 patients were included with a median Injury Severity Sore of 30 and a high rate of severe brain injuries (21% of high intracranial pressure). Incidence of SCVC-related DVT was 37% (95% confidence interval: 26 to 40) in patients or 20/1,000 catheter-days. SCVC-related DVT occurred within 8 days in 65% of cases. There was no significant difference in DVT rates between the aromatic polyurethane and aliphatic polyurethane SCVC groups (38% vs. 36%). SCVC-related DVT independent risk factors were age >30 years, intracranial hypertension, massive transfusion (>10 packed red blood cell units), SCVC tip position in the internal jugular or in the innominate vein, and ipsilateral jugular catheter. Conclusion: SCVC-related DVT concerned one-third of these severely traumatized patients and was mostly clinically silent. Incidence did not depend on the type of polyurethane but was related to age >30 years, intracranial hypertension or misplacement of the SCVC. Further studies are needed to assess the cost-effectiveness of routine screening in these patients in whom thromboprophylaxis may be hazardous.


  • Asymmetry of Bispectral Index (BIS) in severe brain-injured patients treated by barbiturates with unilateral or diffuse brain injury

    by V. Cottenceau, F. Masson, A. Soulard, L. Petit, D. Guehl, J.-F. Cochard, C. Pinaquy, A. Leger, F. Sztark


  • Open Access

    Impact of norepinephrine on the relationship between pleth variability index and pulse pressure variations in ICU adult patients

    by Matthieu Biais, Vincent Cottenceau, Laurent Petit, Françoise Masson, Jean-François Cochard, François Sztark

    Introduction: Pleth Variability Index (PVI) is an automated and continuous calculation of respiratory variations in the perfusion index. PVI correlates well with respiratory variations in pulse pressure (ΔPP) and is able to predict fluid responsiveness in the operating room. ICU patients may receive vasopressive drugs, which modify vascular tone and could affect PVI assessment. We hypothesized that the correlation between PVI and ΔPP and the ability of PVI to identify patients with ΔPP > 13% is dependent on norepinephrine (NE) use. Methods: 67 consecutive mechanically ventilated patients in the ICU were prospectively included. Three were excluded. The administration and dosage of NE, heart rate, mean arterial pressure, PVI and ΔPP were measured simultaneously. Results: In all patients, the correlation between PVI and ΔPP was weak (r2 = 0.21; p = 0.001). 23 patients exhibited a ΔPP > 13%. A PVI > 11% was able to identify patients with a ΔPP > 13% with a sensitivity of 70% (95% confidence interval: 47%-87%) and a specificity of 71% (95% confidence interval: 54%-84%). The area under the curve was 0.80 ± 0.06. 35 patients (53%) received norepinephrine (NE(+)). In NE(+) patients, PVI and ΔPP were not correlated (r2 = 0.04, p > 0.05) and a PVI > 10% was able to identify patients with a ΔPP > 13% with a sensitivity of 58% (95% confidence interval: 28%-85%) and a specificity of 61% (95% confidence interval:39%-80%). The area under the ROC (receiver operating characteristics) curve was 0.69 ± 0.01. In contrast, NE(-) patients exhibited a correlation between PVI and ΔPP (r2 = 0.52; p < 0.001) and a PVI > 10% was able to identify patients with a ΔPP > 13% with a sensitivity of 100% (95% confidence interval: 71%-100%) and a specificity of 72% (95% confidence interval: 49%-90%). The area under the ROC curve was 0.93 ± 0.06 for NE(-) patients and was significantly higher than the area under the ROC curve for NE(+) patients (p = 0.02). Conclusions: Our results suggest that in mechanically ventilated adult patients, NE alters the correlation between PVI and ΔPP and the ability of PVI to predict ΔPP > 13% in ICU patients.


  • Open Access

    Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo™/FloTrac™ device

    by Matthieu Biais, Lionel Vidil, Philippe Sarrabay, Vincent Cottenceau, Philippe Revel, François Sztark

    Introduction: Passive leg raising (PLR) is a simple reversible maneuver that mimics rapid fluid loading and increases cardiac preload. The effects of this endogenous volume expansion on stroke volume enable the testing of fluid responsiveness with accuracy in spontaneously breathing patients. However, this maneuver requires the determination of stroke volume with a fast-response device, because the hemodynamic changes may be transient. The Vigileo™ monitor (Vigileo™; Flotrac™; Edwards Lifesciences, Irvine, CA, USA) analyzes systemic arterial pressure wave and allows continuous stroke volume monitoring. The aims of this study were (i) to compare changes in stroke volume induced by passive leg raising measured with the Vigileo™ device and with transthoracic echocardiography and (ii) to compare their ability to predict fluid responsiveness. Methods: Thirty-four patients with spontaneous breathing activity and considered for volume expansion were included. Measurements of stroke volume were obtained with transthoracic echocardiography (SV-TTE) and with the Vigileo™ (SV-Flotrac) in a semi-recumbent position, during PLR and after volume expansion (500 ml saline). Patients were responders to volume expansion if SV-TTE increased ≥ 15%. Results: Four patients were excluded. No patients received vasoactive drugs. Seven patients presented septic hypovolemia. PLR-induced changes in SV-TTE and in SV-Flotrac were correlated (r2 = 0.56, P < 0.0001). An increase in SV-TTE ≥ 13% during PLR was predictive of response to volume expansion with a sensitivity of 100% and a specificity of 80%. An increase in SV-Flotrac ≥16% during PLR was predictive of response to volume expansion with a sensitivity of 85% and a specificity of 90%. There was no difference between the area under the ROC curve for PLR-induced changes in SV-TTE (AUC = 0.96 ± 0.03) or SV-Flotrac (AUC = 0.92 ± 0.05). Volume expansion-induced changes in SV-TTE correlated with volume expansion-induced changes in SV-Flotrac (r2 = 0.77, P < 0.0001). In all patients, the highest plateau value of SV-TTE recorded during PLR was obtained within the first 90 s following leg elevation, whereas it was 120 s for SV-Flotrac. Conclusions: PLR-induced changes in SV-Flotrac are able to predict the response to volume expansion in spontaneously breathing patients without vasoactive support.